The evaluation of the simultaneous flow rate for sizing the water supply piping in the office building (사무소 건물의 급수배관경 산정을 위한 동시사용유량에 관한 연구)

  • 이용화
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.511-517
    • /
    • 1999
  • Determining the simultaneous flow rate in any particular section of piping is the important step in order to determine the size of water supply piping. Now we are using the diversity curve of common water closet in order to determine the simultaneous flow rate of water supply piping, but there is a difference between a determined flow rate of general water closet and that of water closet for water saving. This study aims to find out the fixture unit of a flush valve type water closet for water saving in office building, and to determine the correlation between the fixture units and peak flow rates on the basis of the probability theory. A flush valve type water closet for water saving that have a 7.5 second duration of flush operation with an average design flow rate 72 $\ell$/fin was considered. Simulation results indicate that the number 5 is shown to be reasonable to the fixture unit of water closet for water saving. And the design can be undersized considerably with the revised diversity curves using modified fixture unit.

  • PDF

The Study on the Effect of Exchanging Water Supply on the Rainwater in Closet of Detached House (주택 대변기용 상수에 대한 우수대체 효과에 따른 연구)

  • Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.4
    • /
    • pp.209-214
    • /
    • 2009
  • The purpose of this study is to investigate the effect exchanging water supply on the' rainwater in detached house. It is difficult to decide water supply amount for a closet in detached house, Therefore, to obtain water supply for closet in detached house, it used regression equation using 1,569 data of frequency of used closet and during 120 days. In detached house, the frequency of used closet is 14.6 times/day and water supply amount is $219 {\ell}/day$. The optimum rainwater tank size which is decided by regression equation and using weather data is $8.5\;m^3$. The effect exchanging water supply on the rainwater in detached house is up 50%.

An Experimental and Simulation Analysis of Condensation in the Walk-in Closet Attached to Apartment Bathroom (욕실과 인접한 아파트 드레스룸의 결로 원인 분석)

  • Choi, Young-Woo;Kim, Sean Hay
    • KIEAE Journal
    • /
    • v.17 no.4
    • /
    • pp.89-94
    • /
    • 2017
  • Purpose: Condensation in walk-in closets attached to apartment bathroom has been known as an emerging issue that may threat occupants' comfort and health. Despite a number of design guidelines and enforcements to prevent condensation, condensation issues may still occur depending on various cases and scenarios. We aim to identify what condensation scenarios may lead to walk-in closet condensation and/or worse the existing condensation issues. Method: First we choose an actual walk-in closet of an apartment that suffers from sporadic condensation and resulting mold and mildew. Then we observe its relative humidity and temperature after the bathroom is used, in which excessive vapor is thought to be transported to the walk-in closet. We analyze Temperature Difference Ratio - a domestic indicator of condensation occurrence, and dew point temperature to compare it with surface temperature using 2D heat transfer simulation upon various condensation scenarios. Result: TDR of the test walk-in closet turns out be OK despite mold and mildew actually occurring. Hot water pipe installed in the floor would greatly reduce condensation. If hot water pipe in the upper floor, however, is not used, or hot water pipe of the closet is turned off during swing seasons, it is expected that condensations may still occur.

A Study on reduction plan of drainage noise for water closet (화장실 배수소음 저감 연구)

  • Lee, J.W.;Jeong, G.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.165-171
    • /
    • 2000
  • The study about a drainpipe of water closet was performed as reduction plan on drainage noise for water closet, which of noise in plumbing systems was being indicated the major point at issue in apartment houses. A drainpipe of water closet is divided into a sleeve, a joint elbow and a traversing pipe, through the result of experiment, for an effective noise reduction in a drainpipe a threefold joint elbow is proposed among parts. And through the experiment of performance with glasswool, the removal of glasswool should be in the economical efficiency aspect.

  • PDF

A study on the water saving device using a variable position straight trap in a water closet system (가변식 직선 트랩 양변기 시스템에 관한 고찰)

  • Suh, Kee-Won;Won, Young-Jae;Lee, Young-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.465-470
    • /
    • 2009
  • This study investigated the water saving technology for the toilet stool system in a water closet. Since in 21st century water would be the prospected factor to measure the wealth of a country instead of the oil, water saving technologies in the toilet stool in a closet system is getting more important than the cleaning stool and the reducing noise performances. According to the statistics in Korea the percentage of using water in toilet is about 27% to the total amount of water used. Therefore, this study theoretically approached the possible amount of water saving and suggested the new variable position straight trap device in the toilet stool system.

  • PDF

A Study on reduction of drainage noise for water closet (공동주택 변기 배수소음 저감 방안에 관한 연구)

  • 김인수;고철수;문재호;한문성;심경석;이준서
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.881-885
    • /
    • 2001
  • The study about a drainpipe of water closet was performed as reduction of drainage noise for water closet. The Drainage noise is composed two characteristics. One is Low frequency noise and the other is high frequency noise. Low frequency noise is dominant in the first stage and high frequency noise is dominant in the last stage. This is due to water splashing and that is caused by formation of chamber pot. In this experiment, for the purpose for reducing the noise, we choose the hollow rubber pipe element. As a result, we reduced drainage noise about 11㏈A.

  • PDF

An Experimental Study on the Noise Characteristics of Water Supply and Drain Installations Varied with Water Suppling Pressure in Apartment Bathroom (급수압 변화에 따른 대변기와 세면기의 급배수 소음 특성에 관한 실험적 연구)

  • Lee, Tai-Gang;Ko, Kwang-Pil;Choi, Eun-Suk;Kim, Hang;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.3 s.120
    • /
    • pp.226-234
    • /
    • 2007
  • This study aims to evaluate noise emission from water supply and drain installations in apartment bathroom. These noise were one of the most annoying noise sources in apartment houses. Especially, drain plumbing system have used bellow bathroom ceiling, it was very discomfort to hear the noise in bellow apartment. Noise of closets and faucets were measured which were main noise source, then these noise were evaluate and analyzed the emitting characteristics varying the supplying water pressure. As increasing the water pressure, also total noise level of the water supplying stool noise and faucet noise were increased. Especially the water closet showed remarkably the increasing noise level in middle and high frequency bandwidth, while the noise level of faucets increased in $50\;Hz{\sim}250\;Hz$ of low frequency bandwidth. Vortex closet were favorable to syphon closet, and lever faucet were favorable to conventional lavatory faucet on reducing the noise. Above these results could be used in basic data establishing KS (Korean Standard) for evaluation and rating procedure and measures reducing these noise.

A study on the malodor exhaust in a water closet system (악취 배출 양변기 시스템에 관한 고찰)

  • Kim, Jong-Ho;Suh, Kee-Won;Son, Jong-Won
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.471-477
    • /
    • 2009
  • This study investigated automatic malodor exhaust ventilating methods in a water closet system. Even though these days advanced equipment has been applied into the toilet in a building or house, the odor due to the evacuating the bowels should be carefully removed to maintain clean and pleasant toilet. Therefore, this study thoroughly considered the main causes of the malodor problems and suggested the best applicable methods to the closet system.

  • PDF

A Study on Reduction Plan of Noise in a Toilet (공동주택 화장실소음 저감방안)

  • 이주원;정갑철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.120-126
    • /
    • 2001
  • The study was performed as reduction plan on drainage noise in a toilet, which of noise in plumbing systems was being indicated the major point at issue in apartment houses. The reduction plan is four items, which are water closet, isolating system for the base of water closet, low noise drainpipe, and a ceiling tex. Through the result of experiment, it was showed that noise reduction is about 9dB(A) within a toilet and above 5dB(A) in a bedroom.

  • PDF

Field Measurements on Drain Noise in Bathroom of Apartment House (공동주택 욕실 배수소음의 현장 측정방법)

  • Yang, K.C.;Lee, T.G.;Kim, S.W.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.345-348
    • /
    • 2005
  • The method of measurement for field tests on noise emission from water closet in bathroom of apartment house. This part of standard gives detailed descriptions for field tests on noise emission from water closet in bathroom. The measuring position have to investigated measuring for emission noise.