• Title/Summary/Keyword: Water age

Search Result 1,541, Processing Time 0.028 seconds

다중 환경추적자를 이용한 제주도 지하수 유동 및 수질 특성 분석

  • 고동찬;김용재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.138-141
    • /
    • 2004
  • The environmental tracers tritium/helium-3 (3H/3He) and chlorofluorocarbons (CFCs) were investigated in ground water from Jeju Island, Korea, a basaltic volcanic island. The apparent 3H/3He and CFC-12 ages were in relatively good agreement in samples with low concentrations of terrigenic He. Ground water mixing was evaluated by comparing 3H and CFC-12 concentrations with mixing models, which distinguished old water with negligible 3H and CFC-12, young water with piston flow, and binary mixtures of the two end members. The ground water CFC-12 age is much older in water from wells completed in confined zones of the hydro-volcanic Seoguipo formation in coastal areas than in water from the basaltic aquifer. Comparison of major element concentrations in ground water with the CFC-12 age shows that nitrate contamination processes contribute more solutes in young water than are derived from water-rock interactions in non-contaminated old water. Chemical evolution of ground water resulting from silicate weathering in basaltic rocks reaches the zeolite-smectite phase boundary. The calcite saturation state of ground water increased with the CFC-12 apparent (piston flow) age. In agricultural areas, the temporal trend of nitrate concentration in ground water was consistent with the known history of chemical fertilizer use on Jeju Island, but the response of nitrate concentration in ground water to nitrogen inputs follows an approximate 10-year delay. Based on mass balance calculations, it was estimated that about 40% of the nitrogen applied by fertilizers reached the water table and contaminated ground water resources when the fertilizer use was at the highest level.

  • PDF

Determining chlorine injection intensity in water distribution networks: a comparison of backtracking and water age approaches

  • Flavia D. Frederick;Malvin S. Marlim;Doosun Kang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.170-170
    • /
    • 2023
  • Providing safe and readily available water is vital to maintain public health. One of the most prevalent methods to prevent the spread of waterborne diseases is applying chlorine injection to the treated water before distribution. During the water transmission and distribution, the chlorine will experience a reduction, which can imply potential risks for human health if it falls below the minimum threshold. The ability to determine the appropriate initial intensity of chlorine at the source would be significant to prevent such problems. This study proposes two methods that integrate hydraulic and water quality modeling to determine the suitable intensity of chlorine to be injected into the source water to maintain the minimum chlorine concentration (e.g., 0.2 mg/l) at each demand node. The water quality modeling employs the first-order decay to estimate the rate of chlorine reduction in the water. The first method utilizes a backtracking algorithm to trace the path of water from the demand node to the source during each time step, which helps to accurately determine the travel time through each pipe and node and facilitate the computation of time-dependent chlorine decay in the water delivery process. However, as a backtracking algorithm is computationally intensive, this study also explores an alternative approach using a water age. This approach estimates the elapsed time of water delivery from the source to the demand node and calculate the time-dependent reduction of chlorine in the water. Finally, this study compares the outcomes of two approaches and determines the suitable and effective method for calculating the chlorine intensity at the source to maintain the minimum chlorine level at demand nodes.

  • PDF

Corrosion Loss of the Shell and the Bulkhead Plates of the Oil Tankers According to Their Age (유조선의 선각외판 및 격벽 부식도의 선령별 변화)

  • Park, Jung-Hee;Park, Si-Jung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.18 no.1
    • /
    • pp.17-23
    • /
    • 1982
  • The corrosion loss of the shell plates and the bulkead plates of the oil tankers, nationalities of which belong to korea are determined and analyzed. The thickness of the plates are determined by use of the ultrasonic thickness meters at the check points set along the fore and aft line and the perpendicular to it. Difference between the original thickness and the determined one are given as the corrosion loss at the present age. 1. On the shell plates (1) The total mean of the corrosion loss shows the greatest value on the load water line in every age classes of the vessels. (2) The total mean of the corrosion loss on the fore and aft line shows little difference, even though it is slightly greater at the fore part, in every age classes of the vessels. (3) The corrosion loss along the perpendicular grows greater in the order of upper bilge line, light water line, freeboard line and load water line at 16 ages of the vessels, and the loss changes in the order of light water line, upper bilge line, freeboard line and load water line at 20 ages of the vessels. (4) The total mean of the corrosion loss along the light water line and upper and lower water line shows the greatest value on the fore part. That along the freeboard line and the load water line shows the greatest value on the midship part and on the after part, respectively. 2. On the bulkhead plates (1) The total mean of the corrosion loss shows the greatest value on the top part at the every age classes of the vessels. (2)The corrosion loss along the perpendicular grows greater in the order of the lower, center and upper part at every age classes of the vessels. (3) The total mean of the corrosion loss at the top part grows greater in the order of the transverse bulkhead of the side oil tank, that of center oil tank, longitudinal bulkhead of center oil tank, and transverse bulkhead of side water tank at the 20 ages of the vessels.

  • PDF

Economic Structure Analysis According to Old Age Household Type (노인가계 유형별 경제구조 분석)

  • Han, Su-Jin;Seo, Ji-Soo
    • Journal of Families and Better Life
    • /
    • v.26 no.2
    • /
    • pp.83-101
    • /
    • 2008
  • This research performs a multi comparison between the age of old households and the economic structure according to accommodation type as well as analyzing the economical structural difference of each type based on the features of aged households. The paper classified aged households into 3 groups according to age distribution. The economic structure analysis according to the age of old households and accommodation type was shown as follow: First, the economical structural analysis based on the age of old households showed a statistical difference in the total, labor, business, property and transfer income variables according to the age of each sample group. However, the non-business income and liabilities did not show a significant difference. Second, in the analysis of different economic earnings and initial expenses of middle-aged households according to the age distribution group showed a disparity in the total, labor, business, property, and transfer income variables according to the age of each sample group. However, aged households showed a statistical difference in total, labor, business and transfer income variables. Third, in the analysis of difference in the expense provision and size of consumption, there was a statistical difference in the expense variables of total consumption, food, dining out, electricity, water, furniture, kitchen supplies, clothing, shoe, education, culture, entertainment, transportation, and communication. Fourth, in the analysis of difference in the size of consumption expense, the initial and middle-aged households showed a statistical difference in the total consumption, food, dining out, electricity, water, furniture, kitchen supplies, clothing, shoe, education, culture, entertainment, transportation, communication, and consumption expense variables. However, the analysis of aged households has shown a statistical difference in the total consumption, food, dining out, electricity, water, furniture, kitchen supplies, clothing, shoe, education, culture, entertainment, transportation, and communication expense variables. The study found a statistical difference in the expense for hygienics that did not appear in the initial and middle-aged households.

Performance of one-part alkali activated recycled ceramic tile/fine soil binders

  • Mawlod, Arass Omer
    • Advances in concrete construction
    • /
    • v.10 no.4
    • /
    • pp.311-317
    • /
    • 2020
  • Performance of Sustainable materials continues through using of recycled waste construction materials to minimize the utilization of the natural resources. The cement industry is a major source of CO2 in the atmosphere which is the main cause of global warming. Replacement of OPC with other sustainable cementitious materials has been the most interesting area of researches. This investigation focuses on the properties of alkali-activated mortar with the different replacement ratios of ceramic tile powder (CTP) by fine soil powder (FSP) (0 to 100)% and different molarities of sodium hydroxide concentrations. The experimental program was conducted by examining the compressive strength, water absorption, and water sorptivity. The results showed that the compressive strength of the specimens at age of (28, 56, and 90 days) increases with an increase in the amount of fine soil powder content and decreases at the age of 120 days. Also, minimum water absorption at the age of 90 days was found in the mixes containing 100% fine soil powder. However, fine soil powder replacement had a negative effect on the sorptivity and water absorption values at the age of 120 days. On the other hand, the 12M sodium hydroxide concentration was considered the optimum concentration compared to other concentrations.

Assessment of Soil Characteristics on External Corrosion of Water Pipes (토양특성이 상수도관의 외부부식에 미치는 영향 평가)

  • Bae, Chul-Ho;Kim, Ju-Hwan;Park, Sang-Young;Kim, Jeong-Hyun;Hong, Seong-Ho;Lee, Kyoung-Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.5
    • /
    • pp.737-745
    • /
    • 2006
  • The goal of this study is to present an external pit corrosion rate($p_{ecr}$) model with considering both the age of pipe and the soil characteristics. The correlation of nonlinear exponential model among conventional empirical models was a little higher than other empirical models in the prediction of $p_{ecr}$ according to the age of pipe. However, there has been a limit to predict Peer with the model by using only a pipe age since installation as a variable. The soil analysis results from sixty nine samples showed that all of the samples were non corrosive in the assessment of ANSI/AWWA scoring system. The correlation of soil corrosion factors and $p_{ecr}$ was also low. The application result of linear and nonlinear regression models that soil characteristics only showed a low correlation with $p_{ecr}$ Proposed nonlinear regression model in this study, with considering both the age of pipe and the soil characteristics, showed a little higher correlation ($R^2=0.46$) than conventional model.

Development of replacement priority by analysis of effect of water meter replacement (수도미터 교체 우선순위 선정기준 개발)

  • Son, Dong-Wan;Kim, Dong-Hong;Lee, Doo-Jin;Jung, Kwan-Sue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.5
    • /
    • pp.509-516
    • /
    • 2014
  • This study describes a reasonable planning method for water meter replacement which can minimize the metering under-registration for an increasement of revenue water. The increment analysis of real water usage was used to establish a replacement plan. The meter replacement database collected from K City was used as the basis of this analysis. The database included 964 connections of domestic and non-domestic consumers that had their meter replaced by aging at 2011. The result showed that the corelation between unregistered water volume and water meter age was lower than commonly expected where the current criteria of replacement is only water meter age(8 years) excluding the meters older than 13 years. And in the analysis result of water usage for 8 years, the total amount and increment of water usage had a significant effect on unregistered water volume. However the relation was different tendency as a total volume and slope of increment. In case of total water volume was larger than 10,000, larger than 7,000 and increment of 0.0 ~ -0.3, larger than 6,000 and increment more than -0.3 were analysed to need a replacement because of metering under-registration.

Effects of the Water Reducing Agent on the Concrete (減水劑가 콘크리트에 미치는 影響)

  • Kim, Jong-Cheon;Doh, Duk-Hyun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.24 no.2
    • /
    • pp.67-75
    • /
    • 1982
  • A study on the effect of water reducing agent on the various characteristics of concrete has been conducted. The experimental results of the study are summarized as follows. 1. Slump test for the concrete added water reducing setretarding agent in proper quantity have been conducted. According to the test results, the decreasing rate of slump value become bigger than plain concrete with increase of the unit weight of cement and elapse of time 2. In case the proper quantity content of maximum compressive strength in Fig. 5 of water reducing set retarding agent is added, unit weight of water is decreased about 15% or so as compared with plain concrete. with the increase of water reducing set accelerating agent content unit weight of water is decreased much more, And other hand, amount of air entraining shows the increasing tendency with the increase of water reducing agent content. 3. The adding rate of water reducing agent which produce maximum strength shows that WR-CH and WR-SA which is water reducing set-starding agent is 0.2% and WR-CO is 0.5% and that WS-PO which is water reducing set accelerating agent is 0.5 4. compressive strength jof the concrete made of sulfate resistant cement shows less than the strength of normal portland cement at initial strength but the strength of both cement shows almost same at curing age of 28 days. 5. when proper quantity of water reducing set retarding agent is used, boned strength is increased about 15% at curing age of 28days. 6. According to the result of durability test, dynamic young's mudulus of elasticity at plain concrete is decreased about 50% as compared with initial step at 300 cycle of freezing and thawing after curing age of days. on the contarary the concrete used water reducing agent is decreased less than 7%.

  • PDF

Effects of Formic Acid Administration in the Drinking Water on Performance, Intestinal Microflora and Carcass Contamination in Male Broilers under High Ambient Temperature

  • Aclkgoz, Z.;Bayraktar, H.;Altan, O.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.1
    • /
    • pp.96-102
    • /
    • 2011
  • In this study, we examined the effects of formic acid administration to the drinking water on performance, intestinal microflora and carcass contamination in male broilers. A total of 312 day-old male broiler chicks were allocated to two groups with three replicates. The first group (control) received normal drinking water (pH 7.4) during the experiment. The second group consumed acidified drinking water (pH 4.5) after 5 d of age. At 43 d of age, twelve birds were randomly selected from the control group to determine the effect of acidified drinking water on carcass contamination. These birds were only given normal or acidified (pH 3) drinking water for 8 h prior to slaughter. The reduction of water pH from 7.4 to 4.5 significantly decreased body weights of male broilers at 21 and 42 d of age. However, no differences were observed between male broilers given normal and acidified drinking water in terms of feed intake, feed conversion ratio and mortality. The pH value of the gizzard contents was not significantly affected by acid water treatment. There were no significant differences in the intestinal population of E. coli, total organism and Salmonella between the groups. The total organism and E. coli counts of the carcass slightly decreased in the acidified group. No Salmonella was identified in carcass samples of any of the treatment groups. The results showed that drinking water acidification did not provide beneficial effects on performance, intestinal microflora and carcass contamination in male broilers.

The Self-healing and Ageing Effect of OPC-GGBFS Cement in Sea-water and Tap-water (해수와 담수에서 OPC-GGBFS 시멘트의 자기치유와 재령효과)

  • Kim, Tae-Wan;Kang, Choonghyun
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.1
    • /
    • pp.11-21
    • /
    • 2017
  • The paper presents experimental results of self-healing effects of OPC-GGBFS paste with cracked and uncracked specimens. The self-healing of cracked specimens is processes of crack closing with re-hydration of unhydrated in crack surface. The OPC paste with GGBFS replacement ratios of 0%, 10%, 20% and 30% were prepared having a constant water-binder ratios of 0.5. The OPC-GGBFS paste specimens immersed in tap-water and sea-water. The temperature of tap and sea-water was $5^{\circ}C$, $15^{\circ}C$ and $25^{\circ}C$. The cracked specimens after deterioration were immersed for 60 days. The relationship between self-healing effect and age-effect was calculate based upon the experimental results. The self-healing effect was measured in ultrasonic pulse velocity (UPV) before and after loading. When the relative change rate of UPV is increases with the increase in GGBFS replacement ratios. Moreover, the self-healing effect is increased with the temperature of tap-water is increase. But the cracked specimens immersed in sea-water was unclear effects of different temperature. Furemore, most of the healing for OPC-GGBFS specimens immersed in tap-water and sea-water occurred during the first 30 days. The self-healing effect until 30 days is higher than that the age-effect. After 30 days, self-effect and age-effect was largely decreases. SEM/EDS analysis of crack on the surface of the specimens in tap-water were covered with aragonite, and sea-water were covered with brucite.