A Study on Feasibility Analysis and Optimum Range Calculation Model by Conversion of Water Supply System (상수도 급수방식 전환의 타당성 분석 및 최적 범위 산정모델 연구)

  • Park, Junyeol;Shin, Hwisu;Seo, Jeewon;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.177-186
    • /
    • 2017
  • This study concerned the analysis on the efficiency of the conversion of water tank type supply system to direct water supply system to examine the feasibility of the conversion, as well as the calculation of optimal conversion range that enables the supply of safe, high-quality water at stable pressure in accordance with the standards of water supply facility. The results of this research showed that when converting water supply system from water tank type supply system to direct water supply system, more nodal points could be properly converted and more reduction of electricity usage was expected in case water pressure rather than residence time was fixed. This means that higher efficacy can be obtained by fixing water pressure when converting water supply system. However, since the number of the locations that received on-spot inspection was small and the electricity usage measured was not exclusively by water supply facility, it is difficult to judge that such reduction of electricity usage accurately represents reduced electricity usage by water supply facility alone. therefore, after having secured on-spot information about a larger number of locations in apartment complexes that have converted water supply system, and utilizing information about electricity usage exclusively by water supply facility, the proposed method of this research could be applied to accurately deducing expected reduction of electricity usage by water supply facilities of various other apartment complexes. It is also considered possible to deduce an effective operation method of water supply system by finding out an area that shows low pressure or low residual chlorine concentration in the optimal conversion range of water supply, followed by estimating the proper location of pumping station or the proper chlorine dosage at the power purification plant that supply water to the target area.

A Presumption of Water Supply Amount for Calculation of Equipment Capacity in High School Building (고등학교 건축물의 장비용량 산출용 급수량 추정)

  • Park Yool;Lee Hak-Soo;Lee Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.10
    • /
    • pp.768-775
    • /
    • 2006
  • The water supply system has been designing by decision process such as calculation of water supply amount, capacity of water tanks and pumps, pipe size. Especially, when we estimate excessively water supply amount, the initial cost and running cost will increase according to enlargement of the water tank and pump capacity, and water quality of ground water tank can become worse. Therefore, calculation of water supply amount is basically most important factor. In order to calculate exactly water supply amount applying domestic real situation, we should set up basic data as well as study calculation methods. This research would consider calculation methods of water supply amount for school building through examine domestic and foreign basic data of water supply amount and characteristics of domestic school, and estimate daily water supply in high school.

낙동강 달서지구 강변 여과수 취수에 관한 예비 연구

  • Kim, Hyeong-Su;Park, Seung-Gi;Jeong, Chan;Baek, Geon-Ha;Won, I-Jeong;Shin, Heung-Seop
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.93-97
    • /
    • 2002
  • This research introduces some preliminary results of bank filtering intake method adopted in Dalseo area, Nakdong River. This intake method has been planned to supply water resources of 41,000 ㎥/day to Goryeong-Gun and Seongju-Gun in 2016. It is believed that the bank filtering intake method can afford to supply 41,000 ㎥/day amount of water resources and that the raw water quality using the method has more advantages in water treatment than direct surface water intake. Even though the safety yield about individual vertical well is roughly estimated to about 2,000 ㎥/day, it is desirable to decrease the safety yield to about 1,000 ㎥/day in the consideration of long term and simultaneous well pumpings and other unknown factors. Ongoing study will give basic data and new techniques to solve the problems appearing in application of bank filtering method as well.

  • PDF

A Simulated Annealing Model for Long Range Water Supply Planning (장기 용수 공급계획 수립을 위한 컴퓨터 모의뜨임 모형)

  • 김승권;이준열
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.20 no.2
    • /
    • pp.77-93
    • /
    • 1995
  • A mathematical model for long-rage water supply planning was formulated as a dynamic plant location problem with network arc capacity expansion, and illustative example was presented. The proposed solution procedure identifies economical construction timings of surface water supply facilities and water conveyence systems and the best water supply operating patterns as well. In this study, we present a heuristic solution procedure using Simulated annealing Method in conjunction with Bertsekas & Tseng's RELAXT-II for the 0-1 integer network problem.

  • PDF

Modeling Procedure to Adapt to Change of Trend of Water Demand: Application of Bayesian Parameter Estimation (물수요의 추세 변화의 적응을 위한 모델링 절차 제시:베이지안 매개변수 산정법 적용)

  • Lee, Sangeun;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.2
    • /
    • pp.241-249
    • /
    • 2009
  • It is well known that the trend of water demand in large-size water supply systems has been suddenly changed, and many expansions of water supply facilities become unnecessary. To be cost-effective, thus, politicians as well as many professionals lay stress on the adaptive management of water supply facilities. Failure in adapting to the new trend of demand is sure to be the most critical reason of unnecessary expansions. Hence, we try to develop the model and modeling procedure that do not depend on the old data of demand, and provide engineers with the fast learning process. To forecast water demand of Seoul, the Bayesian parameter estimation was applied, which is a representative method for statistical pattern recognition. It results that we can get a useful time-series model after observing water demand during 6 years, although trend of water demand were suddenly changed.

A Comparative Study on Drinking Water Quality of Simple Piped Water Supply Systems and Water Pumps According to Seasons (一部 農村 地域의 簡易 上水道와 Pump水의 季節別 水質에 關한 調査硏究 -춘성군 지성을 중심으로-)

  • Chung, Moon Ho
    • Journal of Environmental Health Sciences
    • /
    • v.10 no.1
    • /
    • pp.21-31
    • /
    • 1984
  • The purpose of this study was to find out more effective schemes on safe water supply in rural area. Then, this study was carried out to investigate drinking water qualities of 20 simple piped water supply systems and 20 water pumps in Chun Sung County, Kang Won Province from 12th December to 24th December, 1983 and was compared this results with the previous results that had been carried out at the same sample sites from 1st July to 30th August, 1981. 1. This results of water quality in winter are better than the previous results in summer because this results are identified as safe 20%, unsafe 35% in simple piped water supply systems, safe 50%, unsafe 20% in water pumps and the previous results are identified as safe 1.8%, unsafe 78.6% in simple piped water supply systems, safe 5.5%, unsafe 73.6% in water pumps. 2. Water qualities of water pumps are better than that of simple piped water supply systems because the former is identified as safe 50%, unsafe 20% and the latter is identified as safe 20%, unsafe 35%. 3. Drinking waters that are in need of chlorination in winter as well as summer are 45% of simple piped water supply systems and 30% of water pumps.

  • PDF

The North Korea water supply system investigated using laws and regulations (법령으로 살펴본 북한의 상수도 체계)

  • Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.36 no.4
    • /
    • pp.209-218
    • /
    • 2022
  • This study has been conducted to investigate the North Korea water supply system. For this purpose, laws and regulations concerning the North Korea water utilities were analyzed. According to this study, the water supply system of North Korea is similar to that of South Korea. The major difference between these two systems lies in the national water supplier: South Korea has the national water supplier as well as the municipal suppliers, while there is no national water supplier in North Korea. It is noted that the North Korean water utilities depend on outside suppliers for resources necessary for water production such as electricity, chemicals, spare parts, etc. This could damage the North Korean water utilities. If required resources were not delivered properly (deficient quantity and/or at delayed timing), the water suppliers would encounter difficulties in water production.

A Study on Improvement Working Conditions of Pelagic Sailors (원양어업의 안정적인 선원수급을 위한 근로조건 개선 연구)

  • JUNG, Sang-Yoon;JANG, Jong-Won
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.6
    • /
    • pp.1651-1661
    • /
    • 2016
  • The purpose of this study is to draw up a plan for improving working conditions of distant water fishing vessel crew in order to revitalize the declining distant water fishing industry. Land-based employment has increased as the result of industrialization, which in turn created shortage in marine crew supply for distant water fishing vessels. Pressure on increasing wages for sea farers is put on the industry for this reason, making the labour market in the distant water fishing industry tougher and tighter. Multiple issues have yet to be addressed for distant water fishing vessel crew. They suffer from excessive work compared to other industries. Crew management is another issue, as sea farers face poor labour conditions, working on board vessels in a collective way where no autonomous actions are allowed. Other issues include unqualified crew supply, increasing ratio of labour costs for crew to sales, and intensified implications of labour unions, which are as well making crew supply difficult as a whole. To this end, more well-qualified workers should take part in production operations in the distant water fishery. Both wage increase and working condition improvement should be achieved in order to strengthen motivation towards qualified sea farers. Sustainable crew supply can be achieved when working environments, gender-based working conditions, welfare are prioritized and improved as a whole.

Feasibility Study on the Conjunctive Operation of Water Transmission Systems from Multiple Source with Applying EPAnet (수리해석(水理解析) 모형(模型)을 이용한 다수원(多水源) 송수계통(送水系統)의 연계(連繫) 운영(運營) 방안(方案) 경제성(經濟性) 평가(評價) - 거제시(市)를 대상(對象)으로 -)

  • Ryu, Tae-Sang;Ha, Sung-Ryong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.609-619
    • /
    • 2007
  • The objective of this paper is to evaluate the feasibility of conjunctive Operation between Multi-regional water supply networks from multiple source as a effective way to meet two conditions: to minimize the electric cost for providing water demanded and meet the water flow rate for satisfying customers. EPAnet Model is used to calculate a hydraulic water distribution condition based on an integrated operation of water supply systems located in short distance. The modeling was conducted on several simulation cases including the individual operation by existing inter-regional water supply networks within short distance, the conjunctive operation of more than two existing networks with valve fully closed and full open constraint. As a study distribution system, water supplying systems of the Geojae-city in the Geongsang Namdo Province was selected and investigated. It was found that a well-allocated water supply scheme based on a conjunctive operation promises to save the electric cost and satisfy all operational goals such as stability and revenues during the period. The result such as unit district costs, pareto optimum pump combination sets will be applied to the optimization for a conjunctive operation of existing inter-regional water supply networks within short distance.

Development of optimization model for booster chlorination in water supply system using multi-objective optimization method (다목적 최적화기법을 활용한 상수도 공급계통 잔류염소농도 최적운영 모델 개발)

  • Kim, Kibum;Seo, Jeewon;Hyung, Jinseok;Kim, Taehyeon;Choi, Taeho;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.5
    • /
    • pp.311-321
    • /
    • 2020
  • In this study, a model to optimize residual chlorine concentrations in a water supply system was developed using a multi-objective genetic algorithm. Moreover, to quantify the effects of optimized residual chlorine concentration management and to consider customer service requirements, this study developed indices to quantify the spatial and temporal distributions of residual chlorine concentration. Based on the results, the most economical operational method to manage booster chlorination was derived, which would supply water that satisfies the service level required by consumers, as well as the cost-effectiveness and operation requirements relevant to the service providers. A simulation model was then created based on an actual water supply system (i.e., the Multi-regional Water Supply W in Korea). Simulated optimizations were successful, evidencing that it is possible to meet the residual chlorine concentration demanded by consumers at a low cost.