• 제목/요약/키워드: Water Spray Humidification

검색결과 8건 처리시간 0.03초

반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 평가 (An Assessment of Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms)

  • 김기철;송근수;김형태;유경훈;신대건;박덕준
    • 설비공학논문집
    • /
    • 제25권2호
    • /
    • pp.55-63
    • /
    • 2013
  • For a large-scale semiconductor manufacturing clean room, the energy consumed in an outdoor air conditioning system to heat, humidify, cool and dehumidify incoming outdoor air is very large. In particular, the energy requirement to humidify outdoor air in the winter season is generally known to be high. Recently, in order to overcome the high energy consumption nature of a steam generator in a conventional steam humidification type outdoor air conditioning system, an air washer is often introduced instead of the steam generator in the outdoor air conditioning system, which can be called a water spray humidification type outdoor air conditioning system. Therefore, the assessment and comparison of the annual energy consumed in the steam humidification type and the water spray humidification type outdoor air conditioning systems deserves to be examined in order to reduce the outdoor air conditioning load of a clean room. In the present study, a numerical analysis was conducted to obtain the annual electric power consumption of the two outdoor air conditioning systems. It was shown from the comparison of the numerical results that the water spray humidification type outdoor air conditioning system can reduce about 30% of annual electric power consumption of the steam humidification type outdoor air conditioning system.

흡기 가습에 의한 압축 착화엔진 실린더 내 디젤 연료 분무 특성 예측 (Prediction of Diesel Fuel Spray Characteristics in Compression Ignition Engine Cylinder by Intake Humidification)

  • 민세훈;서현규
    • 한국분무공학회지
    • /
    • 제23권1호
    • /
    • pp.30-35
    • /
    • 2018
  • The objective of this study is to predict numerically the effect of intake humidification on the injected diesel fuel spray characteristics in a compression ignition engine. In this work, Wave model and Ducowicz model were applied as the break-up model and evaporation model, respectively. The amount of water vapor for the humidification was changed from 0% to 30% of injected fuel mass. The number of applied meshes was generated from 49,000 to 110,000. At the same time, the results of this work were compared in terms of spray tip penetration, SMD and equivalence ratio distributions. It was found that the cylinder temperature and cylinder pressure were decreased with increasing water vapor mass by vaporization latent heat and specific heat, however, the difference was very small. So, the spray tip penetration was not different by water vapor mass. Also, higher equivalence ratio distributions were observed with increasing water vapor mass by the improvement of fuel atomization.

반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 비교연구 (Comparative Study on Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air-Conditioning Systems for Semiconductor Manufacturing Clean Rooms)

  • 김형태;송근수;김기철;유경훈;손승우;신대건;박덕준;권오명
    • 대한기계학회논문집B
    • /
    • 제35권12호
    • /
    • pp.1249-1255
    • /
    • 2011
  • 최근의 반도체 제조용 대규모 클린룸에서는 도입 외기를 가열가습 및 냉각감습하는 외기공조시스템의 에너지소비량이 클린룸 환경을 유지하기 위해 필요한 전체 공조에너지의 약 45 %를 차지하고 있다. 특히 동기(겨울철)의 경우 외기를 가습하기 위한 에너지소비량은 매우 높다. 따라서 에너지절감을 통한 제조비용 절감 및 온실가스 감축을 위해 외기부하와 관계되는 공조에너지의 사용효율 증대 및 철저한 사용합리화가 요구되고 있다. 따라서 반도체 클린룸용 외기공조시스템의 핵심 가습방식인 증기가습과 수분무가습 방식에 대한 소비전력량을 분석하는 것은 에너지절약적 측면에서 상당히 가치가 있다고 판단된다. 본 연구에서는 전극봉식 가습기에 의한 증기가습방식 및 에어와셔에 의한 수분무가습방식 외기공조시스템들의 공조프로세스 및 소비전력량을 외기량 1000 $m^3$/h의 경우 기흥지역의 동기 및 하기의 피크부하에 대해 비교하는 실험을 수행하였다. 실험결과들로부터 에어와셔 수분무가습 외기공조시스템이 전극봉식 증기가습 외기공조시스템보다 연간 소비전력량이 적어서 에너지절약적임을 보여주었다.

반도체 클린룸용 외기공조시스템의 수분무 가습을 이용한 에너지절감에 관한 연구 (A Study on Energy Reduction in an Outdoor Air Conditioning System for Semiconductor Manufacturing Cleanrooms Using Water Spray Humidification)

  • 송원일;김기철;유경훈;신대건;태경응;김용식;박덕준
    • 한국입자에어로졸학회지
    • /
    • 제13권2호
    • /
    • pp.65-77
    • /
    • 2017
  • In recent large-scale semiconductor manufacturing cleanrooms, the energy consumption in outdoor air conditioning (OAC) systems to heat, humidify, cool and dehumidify outdoor air(OA) represents about 40~50 % of the total cleanroom power consumption required to maintain cleanroom environment. Therefore, the assessment of energy consumption in outdoor air conditioning systems is essential for reducing the outdoor air conditioning load for a cleanroom. In the present study, an experiment with an outdoor air flow rate of $1,000m^3/h$ was conducted to compare the energy consumption in steam humidification, simple air washer, exhaust air heat recovery type air washer and dry cooling coil(DCC) return water heat recovery type air washer OAC systems. Besides, a numerical analysis was carried out to evaluate the annual energy consumption of the aforementioned four OAC systems. It was shown that the simple air washer, exhaust air heat recovery type air washer and DCC return water heat recovery type air washer OAC systems using water spray humidification were more energy-efficient than the steam humidification OAC system. Furthermore the DCC return water heat recovery type air washer OAC system was the most energy-efficient.

관 내 삽입 인젝터와 사이클론을 이용한 공기 가습 (Humidification of Air Using Water Injector and Cyclonic Separator)

  • 김범준;김성일;변수영;김민수;김현유;권혁률
    • 대한기계학회논문집B
    • /
    • 제34권5호
    • /
    • pp.491-498
    • /
    • 2010
  • 연료전지 자동차는 성능과 수명 측면에서, 전해질막의 가습이 필요하며, 이를 위해 반응기체인 공기, 수소의 높은 가습이 요구된다. 본 연구에서는 내경 75 mm공기공급관 내에 직접 삽입된 인젝터(노즐)과 액적제거를 위한 사이클론을 통한 가습장치를 고안하여 실험을 수행하였다. 충돌형 노즐 3 종류를 이용하여 분사압력, 공기 유량, 분사방향각도를 달리하여 실험을 수행하였다. 가습 성능을 분석하기 위해, 가습효율이라는 개념을 정의하였다. 별도의 외부 열공급원 없이 분사되는 물과 공기의 엔탈피가 자체 기화열 공급원으로, 분사되는 물의 양이 가습에 가장 중요한 변수임을 볼 수 있었다. 사이클론은 높은 공기유량에서 재비산이 발생되는 것을 볼 수 있었다. 노즐타입 PJ24, 분사방향 각도 90도, 분사압력 1200 kPa, 공기 유량 6000 nlpm에서 절대습도 $21.29\;kJ/kg_{da}$, 가습 효율 86.57%를 얻을 수 있었다.

막가습기와 공기극 재순환을 사용한 고분자 전해질 연료전지의 가습특성 해석 (Study on PEM-Fuel-Cell Humidification System Consisting of Membrane Humidifier and Exhaust Air Recirculation Units)

  • 변수영;김범준;김민수
    • 대한기계학회논문집B
    • /
    • 제35권4호
    • /
    • pp.337-344
    • /
    • 2011
  • 고분자 전해질막 연료전지에서 공급 기체의 가습은 연료전지의 효율과 수명 향상 측면에서 필수적이다. 기존의 고분자 전해질막 연료전지의 가습 방법으로 물 분사나 막가습기, 엔탈피 휠 등이 사용되었다. 하지만, 이러한 외부 가습 방법은 시스템 부피를 크게 하고 고출력 구간에서 가습량이 부족한 단점이 있다. 가습 장치의 효율과 전체 연료전지 시스템 효율을 높이려면, 연료전지의 고온다습한 배출기체로부터 열과 수분을 회수할 필요가 있다. 본 연구에서는 연료전지의 고온다습한 배출공기를 재순환하여 공급공기를 1 차로 가습하고 소형의 막가습기로 2 차 가습하는 복합가습에 대한 해석적 연구를 수행하였다. 그리고 최적의 가습 시스템 설계를 위한 새로운 방법을 제안하였다.

흡기관내 와류생성기가 압축착화엔진의 수분 농도 분포 및 연소성능 향상에 미치는 영향 (Effect of Vortex Generator in Intake Pipe on the Moisture Concentration Distributions and Combustion Performance in a CI Engine)

  • 정석훈;서현규
    • 한국분무공학회지
    • /
    • 제23권4호
    • /
    • pp.169-174
    • /
    • 2018
  • In this work, optimization of blade shape for the improvement of mixture formation and vortex of intake port was performed by numerically, and the combustion performance of CI engine with optimized blade shape was investigated. To achieve this, 3 types of blade shape were studied under the different air flow mass conditions and the numerical results were investigated in terms of humidification water, moisture concentration, and velocity distributions. Evaporated liquid mass was also compared under various test conditions to reveal the turbulent intensity in an intake port. It was observed that the optimized blade shape can improve the humidification water, moisture concentration, and velocity distributions of intake port inside. The evaporated liquid mass was also increased under the conditions with blade. Especially, low NOx emissions was observed with optimized blade condition.

An Experimental Study on the Performance of Air/Water Direct Contact Air Conditioning System

  • Yoo, Seong-Yeon;Kwon, Hwa-Kil
    • Journal of Mechanical Science and Technology
    • /
    • 제18권6호
    • /
    • pp.1002-1009
    • /
    • 2004
  • Direct contact air conditioning systems, in which heat and mass are transferred directly between air and water droplets, have many advantages over conventional indirect contact systems. The purpose of this research is to investigate the cooling and heating performances of direct contact air conditioning system for various inlet parameters such as air velocity, air temperature, water flow rate and water temperature. The experimental apparatus comprises a wind tunnel, water spray system, scrubber, demister, heater, refrigerator, flow and temperature controller, and data acquisition system. The inlet and outlet conditions of air and water are measured when the air contacts directly with water droplets as a counter flow in the spray section of the wind tunnel, and the heat and mass transfer rates between air and water are calculated. The droplet size of the water sprays is also measured using a Malvern Particle Analyzer. In the cooling conditions, the outlet air temperature and humidity ratio decrease as the water flow rate increases and as the water temperature, air velocity and temperature decrease. On the contrary, the outlet air temperature and humidity ratio increase in the heating conditions as the water flow rate and temperature increase and as the air velocity decreases.