• Title/Summary/Keyword: Water Spaces

검색결과 337건 처리시간 0.027초

ON ITERATIVE APPROXIMATION OF COMMON FIXED POINTS OF ASYMPTOTICALLY NONEXPANSIVE MAPPINGS WITH APPLICATIONS

  • Kim, Jong Kyu;Qin, Xiaolong;Lim, Won Hee
    • East Asian mathematical journal
    • /
    • 제28권5호
    • /
    • pp.617-630
    • /
    • 2012
  • In this paper, the problem of iterative approximation of common fixed points of asymptotically nonexpansive is investigated in the framework of Banach spaces. Weak convergence theorems are established. A necessary and sufficient condition for strong convergence is also discussed. As an application of main results, a variational inequality is investigated.

부산항의 개발단계별 수질환경변동특성에 관한 연구 (On the Characteristics of the Water Quality Changes due to the Development Phases of Pusan Port)

  • 고영찬;김종인;류청로
    • 한국해양공학회지
    • /
    • 제14권3호
    • /
    • pp.11-19
    • /
    • 2000
  • This study aims to examine the characteristics of the water quality variation in relation to the change of water exchange rate with respect to the development phases of the Pusan port. To clarify the characteristics, water exchange caused by the variations of coastline shape and water surface area was examined by the numerical experiments using the Lagrangian particle tracking model based on 2-D shallow water equation. As the results of numerical experiments, it was proved that the water exchange in the Pusan port was decreased mainly due to the port development and the breakwaters construction. During the port development phases from 1875 to 1998, 35% of the sea-space in the port had decreased to make hinterland spaces. This resulted in the loss of wet-land and coastline change as well as decrease of the water exchange rate at the sea side. The city population in that period had rapidly increased from several thousands to 4 millions, resulting in the large discharge of sewages into the port area. Under the these environmental conditions, it can be clearly said that the water quality in the Pusan port is sensitively affected by the discharge of urban sewages decrease of the water exchange rate in relation to port and urban developments. In the study, the temporal changes of water quality were discussed with respect to the port development phases. It was clear that the water quality wad controlled by the exchange rate change under the port development as well as the input impact into the port from the urbanized city area. To make clean sea of the Pusan port, it is suggested that the sewage control, the water exchange and coastline control should be systematically checked under the concept of eco-friendly development and environmental management.

  • PDF

다양한 강우사상에 대응 가능한 침투여과형 기술개발 (Development Hybrid Filter System for Applicable on Various Rainfall)

  • 최지연;김순석;이소영;남귀숙;조혜진;김이형
    • 한국습지학회지
    • /
    • 제15권4호
    • /
    • pp.535-541
    • /
    • 2013
  • 도시화로 인한 불투수층의 증가는 강우시 유출량 증가, 침투량 감소, 증발산량 감소 등을 유발시키고, 다량의 비점오염물질을 유출시킨다. 이러한 도시화에 의한 환경영향을 최소화하기 위하여 환경부는 2012년 이후 그린빗물인프라(Green Stormwater Infrastructure, GSI)기법을 정책적으로 도입하여 자연적 물순환을 구축하고 비점오염 유출저감을 저감하고자 한다. 본 연구에서는 자연적 물순환 구축을 통한 비점오염저감을 위하여 다양한 강우사상에 적용 가능한 침투여과기술을 개발하고자 한다. 기술의 실제 적용성 평가에 앞서 연구실 규모의 기술평가를 실시하였으며, 8회의 유량변화를 통한 평가를 수행하였다. 연구실 실험결과, 시설의 침투수, 저류수 및 유출수의 오염물질별 평균 EMC의 저감효율은 모든 오염물질 항목에서 50~90%의 범위로 높게 나타났는데 이는 높은 침투유량(약 35%)과 저류량(39%)에 의한 유출저감에 의해 나타났다. 침투여과시설의 지속적 효율은 막힘현상의 최소화로 나타나는데 본 기술의 공극 막힘현상은 누적 TSS 양이 $8.3{\sim}9.0kg/m^2$의 범위에 도달할 때 발생하였으며, 이 값은 타 연구결과에 비해 큰 값으로 나타나 장기간 높은 효율을 유지할 수 있는 것으로 분석되었다. 초기침강지를 설치하지 않은 상태에서도 시설로부터 유출되는 시료내 평균 입경크기는 $10{\mu}m$로 나타났기에 침강지를 설치할 경우 입자제거에 효과적일 것으로 판단된다.

하수처리수의 하천유지용수 활용을 위한 역순환시스템의 비교 (The Inverse Circulation System for Using Treated Waste Water as Instream Flow)

  • 김기형;최계운;안태진;김진홍;심명필
    • 한국수자원학회논문집
    • /
    • 제36권5호
    • /
    • pp.863-878
    • /
    • 2003
  • 본 연구에서는 하천의 유지용수를 확보하기 위하여 하수처리장에서 처리하여 방류하는 하수처리수를 활용하기 위한 방안을 검토하고 이를 하천유지용수로 직접 활용하기 위하여 역순환시스템의 활용을 검토하였다. 역순환시스템은 하천 하류에 위치한 하수처리장으로부터 방류되는 하수처리수를 펌핑하여 하천상류부로 이송함으로써 하천에 부족한 유지유량을 확보하는 방법으로 여러 가지 형태의 이송방안을 조합하여 하천의 특성에 맞는 최적의 시스템을 구성하고 간단한 수처리를 적용함으로서 하수처리수의 수질을 추가적으로 개선할 수 있는 특징이 있다. 또한 이송된 하수처리수를 하천에 유입시키는 방안들은 시각적으로 친수적인 경관을 제공하고 폭기 등에 의한 수질개선효과를 얻을 수 있다. 이러한 하수처리수를 활용한 역순환시스템을 하천유지용수확보에 적용하기 위하여 국내 하수처리장의 처리수 활용실태 및 수질 상태 등을 검토하였고, 국내의 하수처리수 활용 사례를 조사하였으며 외국의 유사사례 조사를 통해 국내에 적용하기 위한 방안을 마련하고 실제 하천을 대상으로 역순환시스템의 적용방안을 제시하였다.

대학 학생 식당의 위생적 공간 계획에 관한 연구 - 서울 E 대학 학생 식당 고객 공간에 HACCP 적용 중심으로 - (A Study on Hygienic Space Planing of a University Student Restaurant - Focused on the customer space in E University Student Restaurant in Seoul Applying HACCP -)

  • 이종란
    • 한국실내디자인학회논문집
    • /
    • 제20권3호
    • /
    • pp.182-189
    • /
    • 2011
  • This research suggests a way of hygienic space planing of the customer space in the university student restaurant of E University in Seoul. For this study. the behavior observation in the restaurant was conducted in order to analyze the sequence of customer behavior related space planing applying HACCP (Hazard Analysis And Critical Control Point). Also the survey was conducted to analyze opinions of customers about hygiene of the space. The results of the analyses of the observation and the survey were similar in terms of hygiene. In conclusion, for hygienic space planing of the customer space in restaurant, the space circulation should be planned according to the hygienic sequence of customer behavior. The spaces in restaurant should be divided into two areas: the clean area and the contaminated area to prevent cross-contamination. The clean area, such as spaces preparing dishes and food including water and table hall where customers eat, should be separated from the contaminated area such as the spaces where waste is handled and where dirty dishes are kept. In order to prevent cross-contamination, hygiene facility to remove contamination should be located before going to the clean area. More specifically, the hygiene facility should be located between a cash counter and a space preparing dishes so that customers can wash their hands before they touch dishes. Space arrangement with feed-back process to check the possible points of cross-contamination and correct space arrangement until the possibility of cross-contamination is removed in the restaurant.

HACCP를 적용한 셀프서비스 식당의 위생적 공간구성에 관한 연구 (A Study on Hygienic Spatial Composition of Self-Service Restaurants by Applying HACCP)

  • 이종란
    • 한국실내디자인학회논문집
    • /
    • 제20권5호
    • /
    • pp.178-187
    • /
    • 2011
  • This research suggested the hygienic spatial composition of sell-service restaurants applying HACCP(Hazard Analysis and Critical Control Point System). The circulation of the food, dishes, waste, workers and customers were each fractionated and arranged according to the hygienic sequence of cooking food in kitchen and process for eating food within the customer space. The spaces were separated by the degree of cleanness(clean area, semi-clean area, contaminated area). After that, hygiene facilities to remove contamination and pass facilities intended to control moving were added at the possible points of cross-contamination in oder to prevent the cross-contamination. For hygienic spatial composition of self-service restaurant, the following should be acknowledged: In the kitchen, spaces in which the food is handled after being heated should be located in the clean area. As of the customer space, spaces where dishes are prepared, food and water is received, and the table hall should be located in the clean area. Food circulation should flow from the contaminated area to the clean area. Food, dishes, waste should be moved through pass facilities so that workers do not have to come and go between other areas of cleanness. Also lockers for private clothes and lockers for uniforms should be separated. Hygiene facilities should be easily accessible so that workers can use them whenever they enter their working area. The contaminated area where dirty dishes are dealed with should be separated from the clean area. Waste should be thrown out without crossing cooking areas. As of customer circulation, the hygiene facility for hand washing should be located near the space where dishes for self-service are placed. The customer circulation should lead customers to leave restaurants after giving back the dirty dishes in the contaminated area.

화북 다목적댐 조경계획 (A Landscape Planning of Multi-purpose Dam in Hwabuk)

  • 안계동;김용근;민권식;강현경;권전오;신지훈
    • 한국조경학회지
    • /
    • 제34권1호
    • /
    • pp.107-119
    • /
    • 2006
  • The Korea Water Resources Corporation(KOWACO) proposed bidding for an alternative design for Hwabuk Multi-purpose Dam in March of 2004. The site is located in Hakseong-ri, Goro-myeon, Gunwi-gun, Gyeongsangbuk-do and has adrainage area of $87.52km^2$. The purpose of this project is to establish an environmentally friendly plan for minimizing the damage that was caused by the construction of the Hwabuk Multi-purpose Dam. The design principle of KOWACO was the restoration of the natural environment, a harmonious landscape, and the creation of a space of regional and local culture. The basic concept of this project involves an ecological-restoration axis and a functional-connection axis. The site is divided into four spaces: (1) the space of memory and symbol, (2) the space of nature and ecology, (3) the space of regional and local culture, and (4) the space of the regional economy. There are four sub-spaces in the space of memory and symbol: the track forest, the time forest, the memory room, and the sun plaza. There are three sub-spaces in the space of nature and ecology: the habitat of aquatic birds, the wind forest, and the eco-corridor. There are five themed parks in the space of regional and local culture: the culture and relic room, the wildflower garden, the ecological pond, the insect observation park, and the pyogo maze. There are three areas in the space of the regional economy: the forest pension, the waterside pension, and the community center, as Dungdungi village was reorganized to serve as a lodging complex. These themed parks, working together, can offer an effective space for nature, culture, rest, and experience.

Unity Engine 기반 수중 로봇 3차원 포지셔닝 프로그램 구현 (Unity Engine-based Underwater Robot 3D Positioning Program Implementation)

  • 최철호;김종훈;김준영;박준;박성욱;정세훈;심춘보
    • 스마트미디어저널
    • /
    • 제11권9호
    • /
    • pp.64-74
    • /
    • 2022
  • 해양자원을 활용하기 위한 수중 로봇과 관련된 연구가 다수 진행되고 있다. 그러나 일반 드론과 다르게 수중 로봇은 매개체가 공기가 아닌 물이기 때문에 위치 파악이 쉽지 않은 문제점이 존재한다. 수중 위치를 확인하기 위한 기존 연구인 수중 로봇의 모니터링 및 포지셔닝 프로그램은 대규모 공간에서 활용하기 위한 목적을 가지고 있기 때문에 소규모의 공간에서 위치 파악 및 모니터링에 어려움을 가지고 있다. 이에 본 논문에서는 소규모 공간에서 지속적인 모니터링과 명령 전달을 위한 3차원 포지셔닝 프로그램을 제안한다. 제안된 프로그램은 수중 로봇의 위치에 깊이를 확인할 수 있도록 다차원 포지셔닝 모니터링 기능과 3차원 화면을 통해 이동 경로 제어할 수 있는 기능으로 구성된다. 성능평가를 통해 수중 로봇이 수조 모습과 동일하게 출력되어 3차원 화면으로 다양한 각도에서 모니터링 확인이 가능하였으며, 설정 경로와 실제 위치의 차이가 평균 6.44m 이내로써 상정 범위 내의 오차를 확인하였다.

Blue dam을 활용한 기존 댐 시설물 상수도 원수 추가 확보 방안 (The method of securing water supply resources of existing dam by using Blue dam)

  • 추태호;윤현철;윤관선;권용빈;심수용;채수권
    • 상하수도학회지
    • /
    • 제29권2호
    • /
    • pp.243-249
    • /
    • 2015
  • To improve stability of the water resources that were seriously affected by climate change and various environmental effects and to supply the clean water always, continuous efforts are essential. Provision of measures with respect of hardware is basically essential to improve the water resources stability due to the topographic characteristic in Korea. However, building a new dam becomes gradually very difficult because of a hardship in selecting right places, opposition forces such as environment and local residents, negative publicity for large civil engineering projects, and so on. The present study, therefore, proposes the Blue dam as an alternative for securing the water resources of a new concept considering domestic conditions. To evaluate the effect of the Blue dam, the Hec-ResSim model is used and the probabilistic discharge flow rate is applied. As a result, when Dam Yeongcheon is applied as a study area, securing water resources of 14 million tons are predicted be secured and the flood control of 15.4 million tons is expected, in comparison with operation of the existing dam only. Consequently, Blue dams are supposed to carry out the function of securing water resources, controling flood, maintaining eco-environmental instream flow, generating hydroelectric power, and providing spaces for recreational activities.

Alcohol-induced hepatic fibrosis in pig

  • Lee, Chang-Woo;Jyeong, Jong-Sik;Lee, Cha-Soo;Jeong, Kyu-Shik
    • 한국동물위생학회지
    • /
    • 제26권4호
    • /
    • pp.345-359
    • /
    • 2003
  • A number of toxicants have been incriminated as a causing hepatic disease. Among many detrimental injury, alcohol has been noted for hepatitis, fatty liver, fibrosis, and hepatic cirrhosis. The purpose of this study was to develop animal model for hepatic fibrosis in pigs fed ethanol, and to search for a new anti-fibrogenic agent via this model. Twelve male Landrace pigs were divided into 3 groups of 4 animals each. Group 1, 2 and 3 were fed with active ceramic water only, ceramic water + liquid diet containing 15% ethanol and normal tap water + liquid diet containing 15% ethanol for 12 weeks, respectively. At week 12, all pigs were immediately sacrificed for collection each tissue and blood. Serologically, serum ALT and AST levels were significantly reversed in group 2, as compared to group 3. They were normal range in pigs of group 1. Microscopically, macrovesicular lipid droplets and moderate hepatocellular necrosis were evident in the tap water + ethanol fed group 3. However, the active ceramic water treated group 1 showed normal architecture. Moreover, in group 2, mild fatty changes and necrosis were observed in hepatocytes. Collagen fibers were increased in spaces surrounding periportal and interlobular connective tissues in the group 3 of tap water + ethanol, but collagen synthesis and its thickness of fibrotic septa connecting portal tracts were markedly reduced in the group 2 of ceramic water + ethanol. Myofibroblasts were detected mainly in the interlobular connective tissues of pig liver of group 3 treated ethanol and tap water. Few to no myofibroblasts were observed in groups 1 and 2. CYP2E1 was not or rarely detected in group 1 fed ceramic water. However, group 2 showed slightly activation of CYP2E1 in the area of pericentral vein, while CYP2E1 was significantly activated in group 3 fed tap water and ethanol. Based on the above data, we believe that we have developed a unique alcohol induced fibrosis model in pig, which will be useful in developing anti-fibrotic agents and drugs. Furthermore, the active ceramic water used in our study had an inhibitory and may be protective against ethanol induced hepatic toxicity and fibrosis.