• 제목/요약/키워드: Water Sensor

검색결과 1,236건 처리시간 0.027초

다공성 PVDF막이 코팅된 Polyaniline 센서의 다양한 습도분위기의 메탄올 가스에 대한 감응특성 (Sensing characteristics of polyaniline sensor coated with porous PVDF layers to methanol gas under various humidity conditions)

  • 임철범;손성옥;허증수
    • 센서학회지
    • /
    • 제15권3호
    • /
    • pp.205-210
    • /
    • 2006
  • Hydrophobic polymer [ex. Poly(vinylidenfluoride)] layer was coated on polyaniline (PANi) sensor to reduce the contamination humidity. The differences in sensitivity to methanol gas detection in various humidity condition between pure-PANi sensor and sensor coated with poly(vinylidenfluoride) polymer (PVDF) (coated-PANi sensor) were investigated. Considering the relation between the density of pore, which was coated on the layer of the PANi sensor, and sensitivity was investigated. To fabricate the porous PVDF layer on PANi sensor, poly(vinylalcohol) (PVA), which is water-soluble polymer, was used. Coated-PANi sensor was less affected by humidity compared with pure-PANi sensor. And higher density of pore on PVDF layer led to higher sensitivity.

Characterization of Cone Index and Tillage Draft Data to Define Design Parameters for an On-the-go Soil Strength Profile Sensor

  • Chung S. O.;Sudduth Kenneth A.
    • Agricultural and Biosystems Engineering
    • /
    • 제5권1호
    • /
    • pp.10-20
    • /
    • 2004
  • Precision agriculture aims to minimize costs and environmental damage caused by agriculture and to maximize crop yield and profitability, based on information collected at within-field locations. In this process, quantification of soil physical properties, including soil strength, would be useful. To quantify and manage variability in soil strength, there is need for a strength sensor that can take measurements continuously while traveling across the field. In this paper, preliminary analyses were conducted using two datasets available with current technology, (1) cone penetrometer readings collected at different compaction levels and for different soil textures and (2) tillage draft (TD) collected from an entire field. The objective was to provide information useful for design of an on-the-go soil strength profile sensor and for interpretation of sensor test results. Analysis of cone index (CI) profiles led to the selection of a 0.5-m design sensing depth, 10-MPa maximum expected soil strength, and 0.1-MPa sensing resolution. Compaction level, depth, texture, and water content of the soil all affected CI. The effects of these interacting factors on data obtained with the soil strength sensor should be investigated through experiments. Spatial analyses of CI and TD indicated that the on-the-go soil strength sensor should acquire high spatial-resolution, high-frequency ($\ge$ 4 Hz) measurements to capture within-field spatial variability.

  • PDF

센서네트워크 환경 기반의 자동 분무기 제어시스템의설계 및 구현 (Design and Implementation the Control System of Automatic Spry Based on Sensor Network Environment)

  • 곽윤식;구본근;정승국
    • 한국항행학회논문지
    • /
    • 제15권1호
    • /
    • pp.91-96
    • /
    • 2011
  • 본 논문은 센서네트워크 기반으로 설계, 구현된 자동 분무기 시스템의 관리를 위한 제어 시스템의 설계에 관한 것이다. 실시간, 대량의 센싱 데이터의 수집 그리고 분석을 통하여 실시간의 맞춤형 응답처리를 수행할 수 있도록 이벤트 기반 서비스 처리 기술을 적용하였다. 센서 제어 시스템-온/습도 센서 입력 데이터, 수위 센서 입력 데이터, 수온 센서 입력 데이터-을 설계하였으며 입력된 센서 데이터의 분석을 통하여 실시간으로 출수 및 압축공기 토출을 제어하는 자동 분무기 제어 시스템을 설계하였다. 실험을 통하여 제안 시스템을 적용하는 경우, 온도는 33% 그리고 습도에 대해서는 37.3%의 개선 효과를 나타냄으로서 안정적인 온/습도 관리가 가능하게 되었다.

A Simple Benzimidazole Based Fluorescent Sensor for Ratiometric Recognition of Zn2+ in Water

  • Zhong, Keli;Cai, Mingjun;Hou, Shuhua;Bian, Yanjiang;Tang, Lijun
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권2호
    • /
    • pp.489-493
    • /
    • 2014
  • A phenylbenzimidazole derivatized sensor (L) that behaves as a ratiometric fluorescent receptor for $Zn^{2+}$ in water has been described. In HEPES buffer at pH 7.4, sensor L displays a weak fluorescence emission band at 367 nm. Upon addition of $Zn^{2+}$, the emission intensity at 367 nm is decreased, concomitantly, a new emission band centered at 426 nm is developed, thus facilitates a ratiometric $Zn^{2+}$ sensing behavior. Sensor L binds $Zn^{2+}$ through a 1:1 binding stoichiometry with high selectivity over other metal cations. Sensor L displays a linear response to $Zn^{2+}$ concentration from 0 to $6.0{\times}10^{-5}M$, sensor L also exhibits high sensitivity to $Zn^{2+}$ with a detection limit of $3.31{\times}10^{-7}M$.

정전용량센서를 이용한 W/O형 유화연료의 정전용량 측정 (The measurement of capacitance of W/O type emulsified fuel using by capacitance sensor)

  • 조성철;오양환;임석연
    • 한국응용과학기술학회지
    • /
    • 제24권4호
    • /
    • pp.377-382
    • /
    • 2007
  • We designed capacitance sensor in order to examine characteristics of W/O type emulsified fuel, so it concluded the following conclusions. The capacitance value of emulsified fuel, using with capacitance sensor, increases as water content increases due to the coalescence. When surfactant increases, the capacitance value decreases, the condition of W/O type emulsified fuel was maintained stably. There was revealed the capacitance value difference of W/O type emulsified fuel in in according to water content. We checked the phase separation of emulsified fuel with the capacitance value difference. The surfactant(HLB=5.4) had better stable condition than surfactant(HLB=4.3). Also, we confirmed that two mixture surfactants were better than one surfactant.

MA : Multiple Acknowledgement Mechanism for UWSN (UnderWater Sensor Network)

  • Shin, Soo-Young;Lee, Seung-Joo;Park, Soo-Hyun
    • 한국멀티미디어학회논문지
    • /
    • 제12권12호
    • /
    • pp.1769-1777
    • /
    • 2009
  • With the advent of the ubiquitous technology age, the progress of network technology has enabled a robust sensor communication, not just in cities, but also in poor surroundings such as deserts, polar regions, or underwater environments. In this paper, we propose a Multiple Acknowledgement (MA) technique to replace the conventional Automatic Repeat request (ARQ) technique. The MA mechanism is to send an Ack to many receivers simultaneously. The CH (master, coordinator) of the unit cluster broadcasts a Beacon frame where Ack information of the previously transmitted data is included. This technique can reduce the number of transmissions and overhead significantly. The proposed technique is a scheme improving the efficiency of an underwater sensor network where the uplink data transmission is the mainstream. The Performance of the ARQ, Block Ack, Pervasive Block Ack and the proposed method were compared with one another and analyzed. The proposed method showed significant performance improvement as compared with the ARQ, BA, and PBA in its channel efficiency.

  • PDF

Design of Internet of Underwater Things Architecture and Protocol Stacks

  • Muppalla, Kalyani;Yun, Nam-Yeol;Park, Soo-Hyun;Kim, Changhwa
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2013년도 추계학술발표대회
    • /
    • pp.486-488
    • /
    • 2013
  • In the earth more than half of the space filled with water. In that water most of the part is in the form of oceans. The ocean atmosphere determines climate on the land. Combining the Underwater Acoustic Sensor Network (UWASN) system with Internet Of Things (IoT) is called Internet of Underwater Things (IoUT). Using IoUT we can find the changes in the ocean environment. Underwater sensor nodes are used in UWASN. Underwater sensor nodes are constructive in offshore investigation, disaster anticipation, data gathering, assisted navigation, pollution checking and strategic inspection. By using IoT components such as Database, Server and Internet, ocean data can be broadcasted. This paper introduces IoUT architecture and and explains fish forming application scenario with this IoUT architecture.

Development of IoT-based non-cleaning water quality measuring equipment

  • Kim, Heung Soe;Ko, Woori;Ko, Kyoung Hak
    • Agribusiness and Information Management
    • /
    • 제9권1호
    • /
    • pp.18-22
    • /
    • 2017
  • It takes lots of time and labor if a worker have to measure the water quality at a certain but designated time every day in an un-automated aqua farm. In addition, if the equipment is soaked in the sea water consistently, it will be contaminated by diverse floating matters and barnacles, and it often becomes mal-functional within 2~3 months. Therefore, we need to develop a system with which the sensed data could be checked in real time and operated automatically, while preventing the contamination of the sensor, a crucial component for water quality measuring equipment, as much as possible, and increasing the replacement cycle. We have developed a non-cleaning water quality measuring equipment and its software which are used in the fishery household of offshore aqua farms. By providing the workers with a mobile application which has a function of monitoring the water quality in real time, they can check the situation directly without going to the fishery household.

크로스 커패시턴스를 이용한 발전기 고정자 권선 절연물 흡습 측정 센서 (Water Absorption Sensor of Generator Stator Bar Insulation using Cross Capacitance)

  • 배용채;김희수;이두영;이욱륜;이래덕
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1972-1977
    • /
    • 2011
  • The mechanical integrity of generator stator windings is one of the critical point because the electric power is generated and conducted to power system through these windings. To cool down the heat emitted from generator winding during its operation, a majority of generators use de-mineralized water characterized by high cooling efficiency. Contrary to such the excellent cooling efficiency, however, the damaged bar insulations attributed to the absorption of cooling water in the generator stator winding lead to highly time- and cost consuming efforts as well as to service deterioration due to unexpected forced outage of generator. It is described that the new design of water absorption sensor using cross capacitance for generator in power plant in order to increase the reliability of water absorption diagnostics for generator stator bar insulation.

Fabrication of a Superhydrophobic Water-Repellent Mesh for Underwater Sensors

  • An, Taechang
    • 센서학회지
    • /
    • 제22권2호
    • /
    • pp.100-104
    • /
    • 2013
  • A superhydrophobic mesh is a unique structure that blocks water, while allowing gases, sound waves, and energy to pass through the holes in the mesh. This mesh is used in various devices, such as gas- and energy-permeable waterproof membranes for underwater sensors and electronic devices. However, it is difficult to fabricate micro- and nano-structures on three-dimensional surfaces, such as the cylindrical surface of a wire mesh. In this research, we successfully produced a superhydrophobic water-repellent mesh with a high contact angle (> $150^{\circ}$) for nanofibrous structures. Conducting polymer (CP) composite nanofibers were evenly coated on a stainless steel mesh surface, to create a superhydrophobic mesh with a pore size of $100{\mu}m$. The nanofiber structure could be controlled by the deposition time. As the deposition time increased, a high-density, hierarchical nanofiber structure was deposited on the mesh. The mesh surface was then coated with Teflon, to reduce the surface energy. The fabricated mesh had a static water contact angle of $163^{\circ}$, and a water-pressure resistance of 1.92 kPa.