• 제목/요약/키워드: Water Absorption Test

검색결과 471건 처리시간 0.031초

발전기 고정자 권선 절연재 흡습 특성에 관한 실험적 연구 (An Experimental Study of Water Absorption Characteristics for Generator Stator Winding Insulation)

  • 배용채;이대성;김희수;김연환;이현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.426-431
    • /
    • 2004
  • Leaking water coolant into stator electrical insulation is a growing concern for the aging water-cooled generator since leaks in the generator water-cooled stator winding can affect machine availability and insulation life. But a domestic techniques of such field are insufficient and depend wholly on GE or TOSHIBA technique. Therefore this paper introduces measuring principle and developed measuring system, which has been used to detecting wet absorption. We accomplished the experiment with a stator promotion of virtue which is used in actual power plant. Also, Experimental method of generator stator winding, which is investigated into wet absorption test.

  • PDF

프리웨팅된 인공경량골재의 흡수 특성 (Water absorption characteristics of artificial lightweight aggregates preparedby pre-wetting)

  • 김유택;장창섭;류유광
    • 한국결정성장학회지
    • /
    • 제21권2호
    • /
    • pp.82-86
    • /
    • 2011
  • 인공경량 골재는 다결정질 소성체를 주 구성으로 하므로 골재 내부에 다량의 공극이 일정비율로 형성되는 것이 특징이다. 이러한 인공경량 골재는 조직 구조의 특성상 외부환경의 변화에 의해 수분이 비정상적인 이동을 보이는 경향이 있다. 다공질 재료의 수분 방출 특성은 일반적으로 기공률 및 기공크기 분포에 크게 좌우되지만, 인공적으로 소결 제조된 경우에는 표면에 생성된 치밀한 구조의 표피층에도 많은 영향을 받을 것으로 생각된다. 인공경량 골재 내부의 수분 이동에 미치는 요인은 골재내의 세공 및 공극의 분포와 형상, 크기, 그리고 프리웨팅 방법 등이 있으며 각 조건에 따라 상당한 차이를 보인다. 본 연구에서는 인공경량 골재를 제조하여 골재의 가압시 흡수 특성이나 침수시간에 대한 흡수율의 거동에 대한 명확한 규명을 함으로써 경량골재 펌프압송을 위한 기초적 자료를 제공하고자 하였다. 본 실험에 사용된 인공경량골재는 독일 'L'사의 상업용 인공경량골재와 본 연구팀이 제조한 2가지 조성의 인공경량골재를 사용하였으며, 골재 수분함침시간, 진공압력, 급냉조건을 변화시켜 골재의 흡수율을 측정하였다. 인공경량골재를 $300^{\circ}C$ 에서 급냉 하였을 경우 24시간 침수보다 높은 흡수율을 보였고, 진공압력에 따라 흡수율이 증가하는 경향이 있으며, -300 mmHg의 진공 압력시 24시간 침수보다 "L"사 골재는 54 %의 높은 증가를 보였으나 K622와 K73 골재는 비교적 적은 2 % 내외의 흡수율 증가양상을 보였다.

무기질 폴리머계 흡수방지재를 도포한 모르터의 발수성능 평가에 관한 실험적 연구 (An Experimental Study on the Water Repellent Property of Mortar Applied Water Repellent Agent of Inorganic Polymer Type)

  • 김영삼;양승도;유재강;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술논문발표회
    • /
    • pp.31-36
    • /
    • 2002
  • Recently, more interests in surface treatment of structure with water repellent agent are steadily increased, But, investigation of its properties such as protection, durability, morphology of micro structure is not sufficient. Therefore, This paper is aimed for the investigation of water repellent property and change of morphology of micro pores in mortar that is treated by water repellent agent(Inorganic polymer based material). Water repellent property, water absorption coefficient, air permeability, porosity and the observation of micro structure was investigated in different water repellent agent type. The test results indicated that water repellent treated mortar showed low absorption coefficient and air permeability(breathing effect). This is why inorganic polymer is coated at the wall of capillary and micro pores, also, the volume of micro pore is reduced without the change of morphology in micro structure.

  • PDF

대체감미료 에리스리톨의 이화학적인 성질에 관한 연구 (Studies on Physicochemical Properties of Erythritol, Substitude Sugar)

  • 변상희;이철호
    • 한국식품과학회지
    • /
    • 제29권6호
    • /
    • pp.1089-1093
    • /
    • 1997
  • 에리스리톨을 설당 대체 감미료 소채로 사용하기 위한 기초 자료를 얻기 위하여 흡습성, 용해도, 수분활성도, 열안정성, 점성과 같은 물성학적 특성을 설탕, 자일리톨, 소르비톨, 프럭토올리고당과 비교 측정하였다. 모든 감미료 중에서 에리스리톨은 가장 낮은 흡습성과 가장 큰 수분활성 저하능력을 나타내었고 $20^{\circ}C$에서 35.8% 용해되어 다른 감미료보다 용해도가 낮았다. 프럭토올리고당이 빠른 감미료들에 비해 현저히 열안정성이 낮았던 반면 에리스리톨의 열안정성은 오히려 설탕보다 컸다 10%, 30% 에리스리톨 용액의 점성은 동일 농도의 다른 감미료 용액의 점성과 비슷하였으나 고농도 50% 이상의 감미료 용액에서의 점도는 분자량이 증가할수록 점토가 증가하였다. 온도 증가에 따른 감미료들의 점성은 감소되었으며 Arrhenius equation으로 표현될 수 있었다. 30% 에리스리톨 용액과 30% 설탕 용액의 유동활성화에너지는 각각 10.8 kcal/g mol와 11.2 kcal/g mol이었다.

  • PDF

Durability assessment of self-compacting concrete with fly ash

  • Deilami, Sahar;Aslani, Farhad;Elchalakani, Mohamed
    • Computers and Concrete
    • /
    • 제19권5호
    • /
    • pp.489-499
    • /
    • 2017
  • Self-Compacting Concrete (SCC) is a new technology capable to flow without segregation or any addition of energy which leads to efficient construction and cost savings. In this study, the effect of replacing the Ordinary Portland Cement (OPC) with Fly Ash (FA) on the strength, durability of the concrete was investigated experimentally, and carbon footprint and cost were also assessed. Four different replacement FA ratios (0%, 20%, 40% and 60%) were used to create four SCC mixes. Standard test methods were used to determine the workability, strength, and durability of the SCC mixes including resist chloride ion penetration, water permeability, water absorption, and initial surface absorption. The axial cube compressive strength tests were performed on the SCC mixes at 1, 7, 14, 28 and 35 days. Replacing the OPC with FA had a significant positive impact on chloride iron penetration resistance and water absorption but had a considerable negative impact on the compressive strength. The SCC mix with 60% FA had 36.7% and 15.8% enhancement in the resistance to chloride ion penetration and water absorption, respectively. Evaluation of the carbon footprint and the cost of each SCC mixes showed the $CO_2$ emissions mixes 1, 2, 3 and 4 were significantly reduced by increasing the FA content from 0% to 60%. Compared with the control mix, the cost of all mixes increased when the FA content increased, but no significant differences were seen between the estimated costs of all four mixes.

무기질 폴리머계 흡수방지재를 도포한 모르터의 발수성능 평가에 관한 실험적 연구 (An Experimental Study on the Water Repellent Property of Mortar Applied Water Repellent Agent of Inorganic Polymer Type)

  • 이일형;엄덕준;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술.기술논문발표회
    • /
    • pp.33-37
    • /
    • 2004
  • Recently, Growing tendency for structure surface to use water repellent agent has increased steadily. But investigation of it's protection and durability property is not sufficient. Therefore, this paper shows the investigation about repellent property and micro structure's change in surface layer of mortar that is applied by water repellent agent. Water repellent property, absorption coefficient, air permeability, porosity and observation of micro construct was investigated according to water repellent agent type. The test results indicated that mortar applied water repellent agent appears tiny absorption coefficient, but air permeability is maintained. The reason is because silane solution is coating at capillary surface of a wall and minute pore structure is changeless.

  • PDF

$LiBr-H_2O$계 흡수식냉동기의 부식에 미치는 온도의 영향 (The Effect of Temperature on Corrosion of Absorption Refrigeration Systems Using $LiBr-H_2O$ Working Fluids)

  • 임우조;정기철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권1호
    • /
    • pp.125-131
    • /
    • 2002
  • This paper was studied on the effect of temperature on corrosion of absorption refrigeration systems using $LiBr-H_2O$ working fluids. In the fresh water and 62 % lithium bromide solution at $70^{\circ}C$, polarization test of SS 400, Cu(C1220T-OL) and Al-Ni bronze was carried out. And polarization behavior, polarization resistance characteristics, corrosion rate(mmpy) and corrosion sensitivity of materials forming absorption refrigeration systems was considered. The main results are as following: (1) As the experimental temperature increase, the change of corrosion rate of Al-Ni bronze become duller than SS 400 and Cu in 62% lithium bromide solution. (2) According as corrosion environment is changed from fresh water to 62% lithium bromide solution, potential change of Cu and Al-Ni bronze become less noble than SS 400. (3) The corrosion sensitivity of Al-Ni bronze was duller than that of Cu and SS 400 in 62% LiBr solution.

LiBr작동유체 중에서 가스흡수식 냉온수기의 국부부식 특성에 관한 연구 (A Study on the Characteristics of Local Corrosion for Gas Absorption Refrigeration and Hot Water Systems in LiBr-$H_2O$ Working Fluids)

  • Uh- Joh Lim;Ki-Cheol Jeong;Byoung-Du Yun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권6호
    • /
    • pp.714-720
    • /
    • 2003
  • Due to the electric power shortage in summer season and regulation of freon refrigerant, the application of gas absorption refrigeration and hot water systems are considerably increasing trend. But, this system consists of condenser, heat exchanger, supply pipe and radiator etc. which are easily corroded by acidity and dissolved oxygen and gases. In result, this system occurs scale attachment and corrosion damage like pitting and crevice corrosion. In this study, electrochemical polarization test of heat exchanger tubing material (copper, aluminium brass, 30% cupronickel(30% Cu-Ni)) was carried out in 60% lithium bromide solution at $95^{\circ}C$. As a result of polarization test, corrosion behavior by impressed potential and local corrosion. such as galvanic corrosion, pitting corrosion behavior, of tubing materials was investigated. The main results obtained are as follows: (1) The effect of pitting and crevice corrosion control of 30% cupronickel in 60% LiBr solution at $95^{\circ}C$ is very excellent. (2) Dissimilar metal corrosion of 30% cupronickel coupling to aluminium bronze is the most sensitive. (3) Current density behavior of tube materials by impressed potential is high in order of copper > aluminium brass > 30% cupronickel.