• 제목/요약/키워드: Wastewater treatment systems

검색결과 281건 처리시간 0.028초

합병정화조 기술현황 및 전망 (Current Condition and Prospect of On-Site Domestic Wastewater Treatment Technologies)

  • 임연택
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 제6회 하계 Workshop (98 한국막학회, 국립환경연구원 국제 Workshop, 수자원 보전과 막분리 공정)
    • /
    • pp.95-112
    • /
    • 1998
  • Water quality in the public water course has been polluted more seriously than ever before due to the increase of the number and aremount of pollution sources such as domestic and industrial wastewater. For water quality conservation, the Korean government has been trying to construct sewage treatment facilities continually, of which treatment capacity reached to 11,452,400m$^{3}$/day in 1996. Night soil treatment facilites of m nationwide have the treatment capacity of 24,038m$^{3}$/day. But water quality has not been improved because the sewer systems were insufficient and the treatment efficiencies of sewage were not high, enough. For renovation of water quality, miscellaneous domestic wastewater must be treated because 27g BOD/day out of total 40g BOD/person-day come from miscellaneous wastewater, comparing to 13g BOD/day from night soil. However, sole treatment purifier treat only night soil from the flushing toilet. Therefore, it may be desirable to treat the miscellaneous domestic wastewater and the night soil from flushing toilet together by joint treatment purifier system as on-site domestic wastewater treatment technology. In Korea, the joint treatment purifier system, introduced in 1997, have the benefit as follows; i) good water poiluion control effect, ii ) good effect on river water flow, iii) water pollution control with sewage treatment facility, and iv) rapid pollution control effect, etc. In order to achieve a good effect as stated before, i ) strengthening effluent guideline including BOD, nitrogen and phosphorus, ii ) specializing operation to maintain high performance, and iii) supporting its construction and maintenance costs by the governmental level may be necessary: In addition, automation system of joint treatment purifier, technology for its package and compactness, and a new bio-media bio-filter with higher capacity should be further developed in agreement with a more stringent effluent guideline.

  • PDF

하수 처리 및 재활용 연못시스템의 국내 응용 (Application of a Pond System to Korea for Treatment and Recycling of Wastewater)

  • 양홍모
    • 상하수도학회지
    • /
    • 제9권2호
    • /
    • pp.108-117
    • /
    • 1995
  • 연못시스템의 처리정도는 기후조건(氣候條件)과 아주 밀접한 관계가 있다. 기존시스템이 없는 경우 비슷한 기후권의 사례지역을 반드시 비교분석하게 된다. 미국 온대권에 위치한 Corinne과 Eudora 시스템의 기온과 태양복사량을 김포지역과 비교한 결과 아주 유사함이 규명되었다. 특히 태양복사열의 경우, 여름철에 김포지역이 두 시스템보다 조류성장에 유리한 조건이다. 국내 중부지방에 Corinne과 Eudora 시스템과 비슷한 연못시스템을 설치운영(設置運營)하는 데는 문제점이 없음을 알 수 있다. 남부지방은 연중기온이 김포지역보다 높으므로 연못시스템의 이용이 김포지역보다 유리하다. 미국에서는 연못시스템이 2차처리시설(次處理施設)로 합법화되어 있으며, 2차처리 수질기준(水質基準)을 충족시키고 있다. Corinne과 Eudora 연못시스템의 처리수준을 분석한 결과 처리수의 $BOD_5$ 가 30mg/l 이하로 처리되고 있으나, SS 농도가 30mg/l 보다 다소 높은 경우가 있다. Eudora시스템에서 4월에 일어나는 연못하수의 회전기간(回轉期間)을 제외하고는 연못시스템에 적용하는 처리수의 SS기준인 70-100mg/l 이내로 처리되고 있다. 우리나라 중부지방에 Corinne과 Eudora 시스템과 유사한 연못처리시스템을 설치(設置)하면 2차 처리수준으로 하수를 처리할 수 있을 것으로 판단된다. 연못시스템은 양어, 작물생산, 레크레이션이용과 결합시킬 수 있어, 국내의 경우 농촌소도시 지역, 도시경계 생산녹지지역, 내륙 및 하구의 저습지(wetland)에서 소형뿐아니라 대형 시스템으로 활용이 가능하다.

  • PDF

Investigation of Bacterial Diversity in Membrane Bioreactor and Conventional Activated Sludge Processes from Petroleum Refineries Using Phylogenetic and Statistical Approaches

  • Silva, Cynthia;Jesus, Ederson C.;Torres, Ana P. R.;Sousa, Maira P.;Santiago, Vania M. J.;Oliveira, Valeria M.
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권3호
    • /
    • pp.447-459
    • /
    • 2010
  • Bacterial diversity of two distinct wastewater treatment systems, conventional activated sludge (CAS) and membrane bioreactor (MBR), of petroleum refineries were investigated through 16S rRNA gene libraries. Sequencing and phylogenetic analysis showed that the bacterial community composition of sludge samples was distinct between the two wastewater treatment systems. MBR clones belonged predominantly to Class Betaproteobacteria, represented mainly by genera Thiobacillus and Thauera, whereas CAS clones were mostly related to Class Alphaproteobacteria, represented by uncultured bacteria related to Order Parvularculales. Richness estimators ACE and Chao revealed that the diversity observed in both libraries at the species level is an underestimate of the total bacterial diversity present in the environment and further sampling would yield an increased observed diversity. Shannon and Simpson diversity indices were different between the libraries and revealed greater bacterial diversity for the MBR library, considering an evolutionary distance of 0.03. LIBSHUFF analyses revealed that MBR and CAS communities were significantly different at the 95% confidence level ($P{\leq}0.05$) for distances $0{\leq}D{\leq}0.20$. This work described, qualitatively and quantitatively, the structure of bacterial communities in industrial-scale MBR and CAS processes of the wastewater treatment system from petroleum refineries and demonstrated clearly differentiated communities responsible for the stable performance of wastewater treatment plants.

The importance of applying an appropriate approach to modelling wastewater treatment plants

  • Dzubur, Alma;Serdarevic, Amra
    • Coupled systems mechanics
    • /
    • 제11권2호
    • /
    • pp.121-132
    • /
    • 2022
  • Wastewater treatment plants (WWTPs) are designed and built to remove contaminants from wastewater. WWTPs are composed of various facilities equipped with hydro-mechanical and electrical equipment. This paper presents a comparison of two different approaches for WWTPs modelling. Static modelling is suitable for determining the dimensions of facilities and equipment capacity. The special significance of this approach is for the design of new plants, i.e., when a very small number of input data on the quantities and composition of the influent wastewater is available. Dynamic modelling is expensive, time consuming and requires great expertise in the use of simulators, models and very good understanding of the treatment processes. Also, dynamic modelling is very important to use for optimization, consideration of future scenarios and also possible scenarios on the plant. The comparison of two approaches was made on the input data from the biggest and most important plant in Bosnia and Herzegovina (B&H)-WWTP Butila (Sarajevo). The main idea is to show the differences between two demanding accesses. It is important to know how to apply an adequate approach to research and solve the set task. The II phase of the plant Butila, which includes the removal of nutrients, is planned in several years and therefore the importance of research has increased.

Abundances of triclosan-degrading microorganisms in activated sludge systems

  • Lee, Do Gyun;Chu, Kung-Hui
    • Environmental Engineering Research
    • /
    • 제20권1호
    • /
    • pp.105-109
    • /
    • 2015
  • Triclosan is a synthetic antimicrobial agent used in numerous industrial and personal care products. Triclosan collected in wastewater treatment plants can be biodegraded up to 80%. However, little is studied about the abundances of known triclosan-degrading bacteria in activated sludge systems. A previous study reported that Sphingopyxis strain KCY1 isolated from activate sludge can cometabolically degrade triclosan. Recently, a quantitative PCR (qPCR) assay specific to strain KCY1 has been developed. Thus, this study investigated the abundance of strain KCY1 in three different activated sludge wastewater treatments using a qPCR assay. Additionally, ammonia-oxidizing bacteria (AOB), known as triclosan-degraders, and amoA gene were quantified. Strain KCY1 were detected in activated sludge samples from three different wastewater treatment plants. The concentrations of strain KCY1 and AOB were on the order of $10^5-10^6$ gene copies/mL, while amoA gene concentration was on the order of $10^4$ gene copies/mL.

태양광/광촉매를 이용한 오폐수 살균특성 (Disinfection Characteristic of Sewage Wastewater Treatment Using Solar Light/TiO2 Film System)

  • 조일형;이내현;안상우;김영규;이승목
    • 한국환경과학회지
    • /
    • 제15권7호
    • /
    • pp.677-688
    • /
    • 2006
  • Currently, the application of $TiO_2$ photocatalyst has been focused on purification and treatment of wastewater. However, the use of conventional $TiO_2$ slurry photocatalyst results in disadvantage of stirring during the reaction and of separation after the reaction. And the usage of artificial UV lamp has made the cost of photocatalyst treatment system high. Consequently, we studied that solar light/$TiO_2$ film system was designed and developed in order to examine disinfection characteristics of sewage wastewater treatment. The optimum conditions for disinfection such as solar light intensity, characteristic of sewage wastewater, amounts of $TiO_2$ and comparison of solar ligth/$TiO_2$ systems with UV light/$TiO_2$ system was examined. The results are as follows: (1) photocatalytic disinfection process with solar light in the presence of $TiO_2$ film more effectively killed total coliform (TC) than solar light or $TiO_2$ film absorption only. (2) The survival ratio of TC and residual ratio of organic material (BOD, CODcr) decreased with remain resistant material. (3) The survival ratio of TC and residual ratio of organic material (BOD, CODcr) decreased with the increase of amounts of $TiO_2$. (4) TC survival ratio decreased linearly with increasing UV light intensity. (5) The disinfection effect of solar light/$TiO_2$ slurry system decreased more than UV light/$TiO_2$ film systems. (6) The disinfection reaction followed first-order kinetics. We suggest that solar light instead of using artificial UV light was conducted to investigate the applicability of alternative energy source in the disinfection of TC and the degradation of organic material.

오염부하량 및 유하거리가 인공습지에 의한 폐수처리 효율에 미치는 영향 (Effect of Pollutant Loading and Flow Distance to Wastewater Treatment Efficiency in the Constructed Wetland System)

  • 김형중;김선주;윤춘경
    • 한국농공학회지
    • /
    • 제39권5호
    • /
    • pp.97-108
    • /
    • 1997
  • Natural wastewater treatment systems using the constructed wetland system were evaluated for the wastewater from the industrial complex in rural areas. For the treatment of wastewater from the industrial complex in rural area, a pilot plant of the constructed wetland system was installed at Baeksuk agri-industrial complex in ChunahnCity, Chunchungnam-Do. The experiment with this pilot plants was performed for 1996 and 1997. Results of the study were summarized as follows. For the BOD and COD, when the pollutant loading of them was about 1 3.8g/$m^2$. day (the concentration was l24.0mg/${\ell}$) arid 24.4g/$m^2$.day(the concentration was 220.Omg/${\ell}$), the removal rate of them was high, 90.2% and 93.4%, respectively. For the SS, the effluent concentration was consistently lower than the water quality standard even though the influent concentration varied significantly, which showed that SS was removed by the system effectively which consist of soil and plants. For the T-N and T-P, when the influent pollutant loading of them were moderately high, 2.8g/$m^2$.day to 7.4g/$m^2$. day(concentration 25.0mg/${\ell}$ to 49.7mg/${\ell}$) for T-N and 1.0g/$m^2$.day to 2.6g /$m^2$.day(concentration 8.6mg/${\ell}$ to 14.7mg/${\ell}$) for T-P, the removal rate of them were 86.5% and 94.0%, respectively. The removal rate by the flow distance increased rapidly in the first 4m from the inlet zone, and gradually there after. The width of system was 2m. Overall, the result showed that constructed wetland system is a feasible alternative for the treatment of wastewater from industrial complex in rural areas. Compared to existing systems, this system is quite competitive because it requires low capital cost, almost no energy and maintenance, and therefore, very cost effective.

  • PDF

Daily influent variation for dynamic modeling of wastewater treatment plants

  • Dzubur, Alma;Serdarevic, Amra
    • Coupled systems mechanics
    • /
    • 제9권2호
    • /
    • pp.111-123
    • /
    • 2020
  • Wastewater treatment plants (WWTPs) with activated sludge system are widely used throughout the most common technologies in the world. Most treatment plants require optimization of certain treatment processes using dynamic modeling. A lot of examples of dynamic simulations require reliable data base of diurnal variation of the inflow and typical concentrations of parameters such as Chemical Oxygen Demand (COD), Total Kjeldahl Nitrogen (TKN), etc. Such detailed data are not available, which leads to problemsin the application of dynamic simulations. In many examples of plants, continuous flow measurements are only performed after the primary clarifier, whereas measurements from influent to the plant are missing, as is the case with the examples in this paper. In some cases, a simpler, faster and cheaper way can be applied to determine influent variations, such as the "HSG-Sim" method ("Hochschulgruppe Simulation"). "Hochschulgruppe Simulation" is a group of researchers from Germany, Austria, Switzerland, Luxembourg, Netherlands and Poland (see http://www.hsgsim.org). This paper presents a model for generating daily variations of inflow and concentration of municipal wastewater quality parameters, applied to several existing WWTPs in Bosnia and Herzegovina (B&H). The main goal of the applied method is to generate realistic influent data of the existing plants in B&H, in terms of flow and quality, without any prior comprehensive survey and measurements at the site. The examples of plants show the influence of overflow facilities on the dynamics of input flow and quality of wastewater, and a strong influence of the problems of the sewerage systems.

인공습지에 의한 농촌오수처리에 관한 연구 (Study on Natural Wastewater Treatment Systems by Constructed Wetland for Rural Area)

  • 윤춘경;권순국;김형중
    • 한국농공학회지
    • /
    • 제39권4호
    • /
    • pp.55-63
    • /
    • 1997
  • Constructed wetland system which can be applied to the rural wastewater treatment system was examined by pilot plant in Kon-Kuk University. Hydraulic loading rate of wastewater was about 0.16m$^3$/m$^2$. day and theoretical detention time in the system was 1.38 days. The effluent of the septic tank for the school building was applied as inflow to the system. The influent concentration of DO was zero but effluent was up to 4.37mg/${\ell}$ which implies that oxygen was supplied enough from atmosphere by reaeration to support biological activity of the system. Average influent concentration of BOD was 104mg/${\ell}$ and effluent was 24mg/${\ell}$ with average removal rate of 76%. Average influent concentration of COD was 215mg/${\ell}$ and effluent was 63mg/${\ell}$ with average removal rate of 70 % . Average influent concentration of SS was 78mg/${\ell}$ and effluent was 10mg/${\ell}$ with average removal rate of 87%. Two components, BOD and SS, are regulated by law to keep maximum water quality standard of 80mg/${\ell}$ when daily outflow rate is less than 100$m^3$/day which is the case of most rural communities. Therefore, the results from the experiment showed that constructed wetland system can meet the water quality standard easily. Average influent concentration of total nitrogen was 165mg/lwhich is relatively higher than normal wastewater, and effluent was about 156mg/${\ell}$ with average removal rate of only 6%. Average influent concentration of total phosphorus was 41 mg/${\ell}$ and effluent was 6mg/${\ell}$ with average removal rate of 87%. Overall, constructed wetland system was thought to be effective to treat wastewater if nitrogen removal mechanism is improved. Considering low cost, less maintenance, and high treatability, this system can be a practical alternative for the wastewater treatment in rural area The experiment was performed during the summer and fall season, and treatment efficiency of the system is expected to decrease in low temperature. therefore, further study including temperature is required to evaluate feasibility of the system more in detail.

  • PDF

Polypropylene Bundle Attached Multilayered Stigeoclonium Biofilms Cultivated in Untreated Sewage Generate High Biomass and Lipid Productivity

  • Kim, Byung-Hyuk;Kim, Dong-Ho;Choi, Jung-Woon;Kang, Zion;Cho, Dae-Hyun;Kim, Ji-Young;Oh, Hee-Mock;Kim, Hee-Sik
    • Journal of Microbiology and Biotechnology
    • /
    • 제25권9호
    • /
    • pp.1547-1554
    • /
    • 2015
  • The potential of microalgae biofuel has not been realized because of the low productivity and high costs associated with the current cultivation systems. In this study, a new low-cost and transparent attachment material was tested for cultivation of a filamentous algal strain, Stigeoclonium sp., isolated from wastewater. Initially, the different materials tested for Stigeoclonium cultivation in untreated wastewater were nylon mesh, polyethylene mesh, polypropylene bundle (PB), polycarbonate plate, and viscose rayon. Among the materials tested, PB led to a firm attachment, high biomass (53.22 g/m2, dry cell weight), and total lipid yield (5.8 g/m2) with no perceivable change in FAME profile. The Stigeoclonium-dominated biofilm consisted of bacteria and extracellular polysaccharide, which helped in biofilm formation and for effective wastewater treatment (viz., removal efficiency of total nitrogen and total phosphorus corresponded to ~38% and ~90%, respectively). PB also demonstrated high yields under multilayered cultivation in a single reactor treating wastewater. Hence, this system has several advantages over traditional suspended and attached systems, with possibility of increasing areal productivity three times using Stigeoclonium sp. Therefore, multilayered attached growth algal cultivation systems seem to be the future cultivation model for large-scale biodiesel production and wastewater treatment.