• Title/Summary/Keyword: Wastewater treatment plant

Search Result 944, Processing Time 0.029 seconds

Optimum Pre-treatment Method in Constructed Wetlands by Natural Purification Method for Treating Livestock Wastewater (자연정화공법에 의한 인공습지에서 효과적인 축산폐수처리를 위한 최적 전처리방법 구명)

  • Park, Jong-Hwan;Seo, Dong-Cheol;Kim, Ah-Reum;Kim, Sung-Hun;Lee, Seong-Tea;Jeong, Tae-Uk;Choi, Jeong-Ho;Lee, Sang-Won;Cho, Ju-Sik;Kim, Hyun-Ook;Heo, Jong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.3
    • /
    • pp.425-433
    • /
    • 2011
  • In order to obtain optimum pre-treatment methods and improve T-N and T-P removal efficiencies, removal rates of pollutants in small-scale livestock wastewater treatment apparatus with water plant filtration bed or activated sludge tank were investigated. Based on the results from the optimum pre-treatment in small-scale livestock wastewater treatment apparatus, removal efficiencies of pollutants in livestock wastewater treatment plant with water plant filtration and activated sludge beds. The removal rates of COD, SS, T-N, and T-P in effluent were 83, 89, 63 and 87% in small-scale livestock wastewater treatment apparatus with water plant filtration bed, respectively. The removal rates of COD, SS, T-N, and T-P in effluent were 96, 95, 86 and 92% in small-scale livestock wastewater treatment apparatus with activated sludge tank, respectively. For increasing the COD, SS, T-N, and T-P removals in small-scale livestock wastewater treatment apparatus, the water plant filtration and activated sludge beds are recommended. In livestock wastewater treatment plant with water plant filtration ($1^{st}$ treatment) and activated sludge ($2^{nd}$ treatment) beds, the concentrations of COD, SS, T-N, and T-P in effluent were 39, 15, 42 and $1mg\;L^{-1}$, respectively. It was shown that the concentrations of COD, SS, T-N, and T-P met acceptable effluent quality standard for livestock wastewater. Based on the above results, the removal rates of COD, SS, T-N, and T-P in effluent were over 99.8, 99.9, 99.2, and 99.9% in livestock wastewater treatment plant, respectively.

Control strategy of primary clarifier operation in wastewater treatment plant during rainfall inflow (초기강우 유입 시 하수처리시설 일차 침전지 운전제어 전략)

  • You, Kwang Tae;Kwon, Hyuk Jae
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.11
    • /
    • pp.947-950
    • /
    • 2019
  • The main feature of this paper is to provide a driving control strategy to improve the primary clarifier treatment efficiency in the initial rainfall inflow. With the recent development of IoT technology and sensing technology, the basis for operation control of wastewater treatment facilities has been improved. As a result of improving the efficiency of treatment of primary clarifier using on-line measurement results, it is possible to minimize the outflow of untreated sewage and contribute to the improvement of operation efficiency of wastewater treatment plants.

The importance of applying an appropriate approach to modelling wastewater treatment plants

  • Dzubur, Alma;Serdarevic, Amra
    • Coupled systems mechanics
    • /
    • v.11 no.2
    • /
    • pp.121-132
    • /
    • 2022
  • Wastewater treatment plants (WWTPs) are designed and built to remove contaminants from wastewater. WWTPs are composed of various facilities equipped with hydro-mechanical and electrical equipment. This paper presents a comparison of two different approaches for WWTPs modelling. Static modelling is suitable for determining the dimensions of facilities and equipment capacity. The special significance of this approach is for the design of new plants, i.e., when a very small number of input data on the quantities and composition of the influent wastewater is available. Dynamic modelling is expensive, time consuming and requires great expertise in the use of simulators, models and very good understanding of the treatment processes. Also, dynamic modelling is very important to use for optimization, consideration of future scenarios and also possible scenarios on the plant. The comparison of two approaches was made on the input data from the biggest and most important plant in Bosnia and Herzegovina (B&H)-WWTP Butila (Sarajevo). The main idea is to show the differences between two demanding accesses. It is important to know how to apply an adequate approach to research and solve the set task. The II phase of the plant Butila, which includes the removal of nutrients, is planned in several years and therefore the importance of research has increased.

Study on the Wastewater Treatment by Floating Aquatic Plant System Using Water Hyacinth for the Industrial Complex in Rural Area (물옥잠을 이용한 수중처리방법에 의한 농공단지 폐수처리에 관한 연구)

  • 윤춘경;김형중;류재현;여운식
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.3
    • /
    • pp.64-71
    • /
    • 1997
  • Floating aquatic plant system using water hyacinth was applied to examine feasibility as a wastewater treatment system for the industrial complex in rural area. The wastewater from the industrial complex does not likely contain toxic pollutants because the industries which generate wastewater with toxic compounds are not allowed to move in. Pilot plant was installed at Baeksuk Nongkong Danzi in Chunahn-City, Chunchungnam - Do , and field study was performed during summer and fall of 1996. Hydraulic loading rate was 0. $0.19m^3/m^2$.day. The effluent concentration of DO was higher than influent, and it implies that 0.6m depth reactor was reaerated enough to increase DO level. The influent concentration of BOD varied significantly from less than 30 to 120mg/${\ell}$ during the study period, however, effluent concentrations were generally lower than the water quality standard and removal efficiency was up to 85%. The influent concentration of COD also showed wide variation from less than 40 to 160mg/${\ell}$ and effluent concentration was higher than water quality standard when influent concentration was over l00mg/${\ell}$. The influent concentrations of T-N and T-P were lower than water quality standard and no further treatment was required, and these compounds were also removed in the system. Although some improvement and refinement are still required, overall* the floating aquatic plant system was proved to be feasible to apply to treat wastewater from industrial complex in rural area.

  • PDF

Treatment of Wastewater Containing Ethanolamine in Secondary System of Nuclear Power Plant (Ethanolamine이 포함된 원자력발전소 2차계통 폐수처리)

  • Lee, Han Chul
    • Applied Chemistry for Engineering
    • /
    • v.24 no.1
    • /
    • pp.38-43
    • /
    • 2013
  • ETA (ethanolamine), a pH control agent, has been used as an ammonia substitute in the secondary system of nuclear power plants since 2001. It is impossible to remove ETA from the wastewater treatment system in the nuclear power plant operating currently, because it is the non-biodegradable organics in terms of the environmental. The optimum process and chemicals for the removal of chemical oxygen demand (COD) & N with the field sample were investigated. More than 95% of Ammonium ions, contained much in wastewater, was removed with a diffused aeration system. COD could be removed over 90% through the process that includes the oxidation with mixed peroxidants (sodium persulfate/sodium percarbonate) followed by the physicochemical treatment with coagulants.

A study on the desulfurization wastewater treatment using Ferrate(VI) (Ferrate(VI)를 이용한 발전소 탈황폐수 처리에 관한 연구)

  • Jo, Eun-young;Park, Chan-gyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.297-301
    • /
    • 2017
  • Wastewater treatment using ferrate (VI) solution is becoming a promising technology for several years, because it is high efficient and harmless technology. In this study, the ferrate (VI) solution was tested to treatment of desulfurization wastewater. The effluent from desulfurization wastewater treatment process of power plant was used as raw water, and the COD and T-N removal efficiency of ferrate(VI) solution were investigated. In the test, as the injection rate increased from 0.1 to 1.0%, the removal efficiency of COD also slightly increased, about 80% of COD were removed in 1.0% of injection rate. In the case of T-N, about 50% of T-N was removed in the condition of 1.0% of injection rate. The removal efficiency of COD and T-N also affected by reaction time, maximum removal efficiency was shown in 30 min of treatment. From these results, the wastewater treatment with ferrate(VI) solution can be great solutions for treatment of non-biodegradable pollutants in wastewater, especially for the 3rd treatment of wastewater.

Nanowastes treatment in environmental media

  • Kim, Younghun
    • Environmental Analysis Health and Toxicology
    • /
    • v.29
    • /
    • pp.15.1-15.7
    • /
    • 2014
  • Objectives This paper tried to review a recent research trend for the environmental exposure of engineered nanomaterials (ENMs) and its removal efficiency in the nanowaste treatment plants. Methods The studies on the predicted environmental concentrations (PEC) of ENMs obtained by exposure modeling and treatment (or removal) efficiency in nanowaste treatment facilities, such as wastewater treatment plant (WTP) and waste incineration plant (WIP) were investigated. The studies on the landfill of nanowastes also were investigated. Results The Swiss Federal Laboratories for Materials Science and Technology group has led the way in developing methods for estimating ENM production and emissions. The PEC values are available for surface water, wastewater treatment plant effluents, biosolids, sediments, soils, and air. Based on the PEC modeling, the major routes for the environmental exposure of the ENMs were found as WTP effluents/sludge. The ENMs entered in the WTP were 90-99% removed and accumulated in the activated sludge and sludge cake. Additionally, the waste ash released from the WIP contain ENMs. Ultimately, landfills are the likely final destination of the disposed sludge or discarded ENMs products. Conclusions Although the removal efficiency of the ENMs using nanowaste treatment facilities is acceptable, the ENMs were accumulated on the sludge and then finally moved to the landfill. Therefore, the monitoring for the ENMs in the environment where the WTP effluent is discharged or biomass disposed is required to increase our knowledge on the fate and transport of the ENMs and to prevent the unintentional exposure (release) in the environment.

Bench-Scale Evaluation of the Activated Sludge Process for Treatment of a High-Strength Chemical Plant Wastewater (활성슬러지법에 의한 고농도 중화학공장 폐수처리에 관한 연구)

  • 조영하
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.3
    • /
    • pp.1-16
    • /
    • 1993
  • This paper describes an investigation to determine whether the activated sludge (AS) process could be used for the treatment of wastewater at the Union Carbide Coporation (UCC) plant in Seadrift, Texas. This plant presently utilizes a waste stabilization pond (WSP) system for treatment of the wastewater. The treatment system consists of an in-plant primary WSP and two off-plant WSPs (secondary and tertiary WSPs), run in series. The total hydraulic detention time of the WSP system is approximately 150 days. Several laboratory-based treatability studies have been conducted to evaluate the performace of the WSP system and the degradability of specific chemical compounds. From an additional study, it was determined that the WSP system was stressed and occasionally operating near the limit of its treatment capacity. The existing primary WSP plays an important role in the overall treatmemt system, because it not only functions as a pH and organic-strength equalization basin, but also serves as a "preconditioning" basin by fermenting high strength organic wastes to volatile organic acids for subsequent degradation in the escondary WSP. However, in view of pending RCRA legislatin conerning the "proposed organic toxicity characteristics limits" (40 CFR Part261: Federal Register, July, 1988), it is possible that the primary WSP will have to be abandoned in favor of alternative treatment options. Therefore the main purpose of this study was to perform activated sludge treatability evaluations for the development of an alternative to the existing primary WSP treatment ststem. In addition, another purpose was to determine the degradability of bis(2-chloroethyl)ether (Chlorex or CX) and benzene(BZ) in the activated sludge process. The presence of these two chemicals in the wastewater of the plant prompted the question of whatedether they could be degraded in an activated sludge system.

  • PDF

Forecast of Influent Characteristics in Wastewater Treatment Plant with Time Series Model (시계열모델을 이용한 하수처리장 유입수 성상 예측)

  • Kim, Byung-Goon;Moon, Yong-Taik;Kim, Hong-Suck;Kim, Jong-Rack
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.701-707
    • /
    • 2007
  • The information on the incoming load to wastewater treatment plants is not often available to apply to evaluate effects of control actions on the field plant. In this study, a time series model was developed to forecast influent flow rate, BOD, COD, SS, TN and TP concentrations using field operating data. The developed time series model could predict 1 day ahead forecasting results accurately. The coefficient of determination between measured data and 1 day ahead forecasting results has a range from 0.8898 to 0.9971. So, the corelation is relatively high. We made forecasting program based on the time series model developed and hope that the program will assist the operators in the stable operation in wastewater treatment plants.