• 제목/요약/키워드: Wastewater

검색결과 7,016건 처리시간 0.028초

화학적산화 및 생물학적처리법에 의한 사진폐액의 처리 (Treatment of Photographic Wastewater by Chemical Oxidation and Biological Treatment process)

  • 정경훈;최형일
    • 한국환경보건학회지
    • /
    • 제23권1호
    • /
    • pp.34-42
    • /
    • 1997
  • A laboratory experiments were performed to investigate the treatment of photographic processing wastewater by chemical oxidation and biological treatment system. The effect of reaction conditions such as hydrogen peroxide dosage, ferrous sulfate dosage and pH on the COD removal in Fenton oxidation were investigated. The optimal dosage of hydrogen peroxide was 2.58 M and 3.87 M for the developing and fixing process wastewater, respectively. The Fenton oxidation was most efficient in the pH range of 3-5 and the optimal condition for initial reaction pH was 5 for a developing process wastewater. With iron powder catalyst, the COD for a developing process wastewater was removed in lower pH than with ferrous sulfate catalyst. The removal efficiency of COD for refractory compounds such as Diethyleneglycol, Benzylalcohol, Hydroxylamine Sulfate, Ammonium Thiosulfate, Ammonium Ferric EDTA and Disodium EDTA in the photogaphic wastewater was found than 90% except Potassium Carbonate. When the photographic processing wastewater after pretreatment by Fenton oxidation was treated with batch activated sludge process, the addition of $KH_2PO_4$ as a phosphorous compound improved the removal efficiency of COD. During the continuous biological treatment of developing and fixing process wastewater after pretreatment by Fenton oxidation, the effluent COD concentration less than 100 mg/l was obtained at 0.425 and 0.25 kgCOD/m$^3$.d, respectively.

  • PDF

이온화가스에 의한 축산폐수 처리 특성에 관한 연구 (Study on the Characteristics of Livestock Wastewater Treatment by Ionized Gas)

  • 정팔진;이은주;김민정
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.37-41
    • /
    • 2004
  • This paper was studied about the characteristics of treatment by ionized gas for livestock wastewater, aiming at the effects of ionized gas on organic matter, hydrophobic and hydrophilic organic matter in livestock wastewater when the new process of advanced oxidation process was applied for meeting the improved the quality of effluent. The organic matter within treated livestock wastewater by ionized gas was partially mineralized according to the time increasement. The $TCOD_{Mn}$ in the livestock wastewater was decreased from 840mg/L to 340mg/L when treated by ionized gas by the enhancement of time. We occupied the equations of $TCOD_{Cr}$, $SCOD_{Cr}$, $TCOD_{Mn}$ and $SCOD_{Mn}$ as to ionized gas treated time. As $TCOD_{Mn}$ increasing ionized gas treated time, the concentration did not meet the water quality, $COD_{Mn}$ 4Omg/L. So, for removing of the remaining organic matter in the efflent after ionized gas, following process is necessary. After treating the livestock wastewater by ionized gas, coagulation was considerable for organic matter removal up to regulation water quality. From UV scans of the treated livestock wastewater by ionized gas, the wastewater has low aromaticity and good colour.

Textile dye wastewater treatment using coriolus versicolor

  • Sathian, S.;Radha, G.;Priya, V. Shanmuga;Rajasimman, M.;Karthikeyan, C.
    • Advances in environmental research
    • /
    • 제1권2호
    • /
    • pp.153-166
    • /
    • 2012
  • Decolourization potential of white rot fungal organism, coriolus versicolor, was investigated in a batch reactor, for textile dye industry wastewater. The influence of process parameters like pH, temperature, agitation speed and dye wastewater concentration on the decolourization of textile dye wastewater was examined by using Response surface methodology (RSM). The maximum decolourization was attained at: pH- 6.8, temperature - $27.9^{\circ}C$, agitation speed - 160 rpm and dye wastewater concentration - 1:2. From the analysis of variance (ANOVA) results it was found that, the linear effect of agitation speed and dye wastewater concentration were significant for the decolourization of textile dye wastewater. At these optimized condition, the maximum decolourization and chemical oxygen demand (COD) reduction was found to be 64.4% and 79.8% respectively. Various external carbon sources were tried to enhance the decolourization of textile dye wastewater. It was observed that the addition of carbon source enhances the decolourization of textile dye wastewater. Kinetics of textile dye degradation process was studied by first order and diffusional model. From the results it was found that the degradation follows first order model with $R^2$ value of 0.9430.

축산폐수성상에 따른 SBR 처리특성 (The Characteristics of SBR Treatment with Different Types of Piggery Wastewater)

  • 전병희;부경민;김양훈;임정훈;김창원
    • 한국물환경학회지
    • /
    • 제18권4호
    • /
    • pp.435-440
    • /
    • 2002
  • A pilot scale SBR (effective volume, $20m^3$) for the treatment of piggery wastewater treatment was performed with three different kinds of wastewater; fermenter effluent, scraper type and slurry type. The react phase in SBR was performed by sub-cycle operation consisting of repeated short cycle of anoxic-aerobic step. The fermenter effluent was characterized by the rapid nitrification and $NO_X-N$ accumulation due to depletion of organic matter in wastewater. The scraper type wastewater showed appropriate nitrogen removal efficiency, however, a poor response capacity for high loading rate often resulted in increased nitrogen concentration in effluent. Moreover, severe P release was the most serious problem in scraper type wastewater. SBR treated slurry type wastewater with high nitrogen removal efficiency to satisfy effluent quality requirement. It was thought that high concentration of organic matter in slurry made it possible to uptake P during SBR operation, where P concentration of 140mgP/l was decreased to 8mgP/l. As results, SBR was suitable to treat slurry type wastewater which has been discharged to the ocean till now.

국내 하수종말처리장 최적 운전 방안에 관한 연구 (A Study of Optimum Operational Methods for Domestic Wastewater Treatment Plants in Korea)

  • 이병희;이용운
    • 상하수도학회지
    • /
    • 제14권1호
    • /
    • pp.45-53
    • /
    • 2000
  • The optimum operation of domestic wastewater treatment plant can give influence on operational cost and future expansion in Korea where has 93 operational domestic wastewater treatment plants. Also, the study on optimum operation can reduce operation cost and budget of municipalities whom have responsibility of wastewater treatment plant operation. In this study, 9 domestic wastewater treatment plants which can represent 93 plants in Korea have been selected and operational data are gathered. The collected data are inputted to computer simulator based on IAWQ's Activated Sludge Model No.1 and optimum operation methods are developed. Also, the electric power for aeration which has large portion of overall operation cost are calculated based on design and operation conditions and these are compared. In this study, it was found that design wastewater characteristics are 1.6 times higher than those of daily maximum except for E plant and that estimation methods for design wastewater characteristics have to be improved. Based on computer simulation, we found there is no need to operate all aeration tanks due to weak influent overall power for aeration can be reduced to about 43% of design one.

  • PDF

폴리에스테르 감량가공(減量加工) 폐수(廢水)의 최적(最適) 처리방안(處理方案)에 관한 연구(硏究) (A Study on the Treatment of Wastewater from the Weight-Reduction Process of Polyester)

  • 정윤진;양태두;김웅하
    • 상하수도학회지
    • /
    • 제7권1호
    • /
    • pp.20-28
    • /
    • 1993
  • The Wastewater from the weight reduction process of polyester is more difficult to be treated biologically than the general wastewater from dyeing and finishing processes in textile industries. Above wastewater shows high pH, high organic strength and wide variation of organic loading. These characteristics are due to TPA and EG resulting from alkaline weight-reduction process and make trouble in the operation of activated sludge process. Therefore, the objective of this study is to develop the pretreatment method for the successful operation of treatment process. For the successful pretreatment process, the wastewater from weight-reduction process should be segregated from other wastewater stream and then acidified with concentrated sulfuric acid to precipitate out TPA from DST solution. At the optimum pH of 2. 2, the initial $COD_{cr}$ 60,000mg/l is reduced to 11,500mg/l and the removal efficiency of $COD_{cr}$ is 81.1%. The required amount of sulfuric acid for pretreatment is not greater than the amount for the the existing neutralization process. Moreover, the supernatant of pretreatment process can be reused in acidification of wastewater.

  • PDF

이상 혐기성 공정을 이용한 음식물류폐기물폐수와 양돈폐수의 혼합액으로부터 수소 및 메탄 생산 (Hydrogen and Methane Production from Mixture of Food Wastewater and Swine Wastewater using Two-Phase Anaerobic Process)

  • 김충곤;강선홍
    • 상하수도학회지
    • /
    • 제22권3호
    • /
    • pp.299-306
    • /
    • 2008
  • This study has been conducted to derive the bio-energy, hydrogen and methane production, from mixture of food wastewater and swine wastewater, the high strength organic wastewater and to increase effluent quality. To overcome this limitation in one-phase anaerobic process, two-phase anaerobic process combining hydrogen fermenter and methane fermenter was applied. In this system $2,323ml\;H_2/L$ was produced daily from Run II where 500 ml of heattreated sludge in methane fermenter was injected, and methane produced from methane fermenter did not show big difference regardless of the amount of returning sludge at each Run. It was concluded that the two-phase anaerobic process was the appropriat process to produce hydrogen and methane simultaneously and stably. Influent $TCOD_{Cr}$ to two-phase anaerobic process showed the range of 132~145 g/L(average 140 g/L), and effluent $TCOD_{Cr}$ range was 25~40 g/L(average 32 g/L), and organic removal efficiency showed 71~82%(average 76.3%).

폐수의 악취측정을 위한 금속산화물 반도체 및 전기화학식 가스센서 어레이 특성 평가 (Evaluation of Metal Oxide Semiconductor and Electrochemical Gas Sensor Array Characterization for Measuring Wastewater Odor)

  • 임봉빈;이석준;김선태
    • 센서학회지
    • /
    • 제24권1호
    • /
    • pp.29-34
    • /
    • 2015
  • This study aimed to evaluate the characterization of a metal oxide semiconductor and electrochemical gas sensor array for measuring wastewater odor. The sensitivity of all gas sensors observed in sampling method by stripping was 6.7 to 20.6 times higher than that by no stripping, except sensor D (electrochemical gas sensor). The average reduction ratio of sensor signal as a function of initial dilution rate of wastewater was in the order of food plant > food waste reutilization facility > plating plant. The sensitivity of gas sensors was dependent on both the type of wastewater and the dilution rate. The sensor signals observed by the gas sensor array were correlated with the dilution factor (OU) calculated by the air dilution sensory test with several wastewater ($r^2=0.920{\sim}0.997$), except the sensor signals of sensor D measured in the plating plant wastewater. It seems likely that the gas sensor array plays a role in the evaluation of odor in wastewater and is useful tool for on-site odor monitoring in the wastewater facilities.

응집제와 관형막을 활용한 CMP 폐수 처리 가능성 연구 (The Feasibility Study of CMP Wastewater Treatment Using Tubular Membrane and Coagulants)

  • 정호찬;정철중;송자연;김연국;이선용
    • 한국물환경학회지
    • /
    • 제28권5호
    • /
    • pp.639-645
    • /
    • 2012
  • The purpose of this study is to identify the possibility of the CMP wastewater treatment from semiconductor fabrication under operating tubular membrane with coagulants. To find suitable coagulants treating CMP wastewater, we conducted Jar-test. After Jar-test experiments suitable coagulants are PAC(17%), $Ca(OH)_2$ and optimum coagulant dosage is PAC(17%) 10mg/L, $Ca(OH)_2$ 110 ~ 120mg/L. Based on these results, the tubular membrane was applied to CMP wastewater, the turbidity removal efficiency is $Ca(OH)_2$ > PAC(17%) > Nothing. The fast cross-flow velocity and backwash process what are operating characteristics of tubular membrane can be stable CMP wastewater treatment. But when the coagulant and tubular membrane are used at the same time, the withdraw and treatment of the CMP wastewater are possibile. However further treatment process needs if treated water will be used for semiconductor fabrications.

고정화 공생 Bacteria를 이용한 호발폐수 중 PVA분해 신공정 개발 (Development of a New Process for PVA Degradation in Desize Wastewater by lmmobilized Symbiotic Bacteria)

  • 김정목;조무환조윤래정선용
    • KSBB Journal
    • /
    • 제6권4호
    • /
    • pp.395-402
    • /
    • 1991
  • A new process was developed to degrade PVA(polyvinyl alcohol) in desize wastewater. Two symbiotic bacteria of Pseudomonas strain G5Y and PW were immobilized on the media by adsorption. A natural zeolite was chosen as the best media considering cell adhesion capacity, sedimentation rate, and material cost. PVA and COD removal efficiencies of this system for synthetic wastewater were 84% and 85% at the retention time of 6 hr, when the volumetric loading rate was PVA 8g/L·day and COD 8g/L·day, and cell density was 19,775 mg/L. In case of desire wastewater, they were 78% and 72% at the retention time of 6 hr, respectively, when the volumetric loading rate was PVA 8g/L·day and COD 13.2g/L·day, and cell density was 32,899mg/L. In case of desize wastewater, PVA and COD removal efficiencies were lower than synthetic wastewater, but cell density of the desize wastewater was lower than that of the synthetic wastewater, because there were insufficiency of necessary nutrition and variety of desize materials in the desize wastewater. A pilot test was successfully performed showing 88% and 82%, PVA and COD removal efficiencies at the retention time of 24 hr, when volumetric loading rate were 4.7 PVA g/L·day and COD 6.9g/L·day, and cell density was 12,,324 mg/L.

  • PDF