• Title/Summary/Keyword: Wang Tao

Search Result 371, Processing Time 0.023 seconds

Fire performance of concrete-filled steel tubular columns strengthened by CFRP

  • Tao, Zhong;Wang, Zhi-Bin;Han, Lin-Hai;Uy, Brian
    • Steel and Composite Structures
    • /
    • v.11 no.4
    • /
    • pp.307-324
    • /
    • 2011
  • With the increasing use of concrete-filled steel tubes (CFST) as structural members, there is a growing need to provide suitable measures for possible strengthening or repair of these kinds of structural elements. Fibre reinforced polymer (FRP) jacketing is a recent method and is particularly attractive in which it does not significantly increase the section size, and is relatively easy to install. Thus, it can be used to enhance strength and/or ductility of CFST members. Very little information is available on the performance of FRP-strengthened CFST members under fire conditions. This paper is an attempt to study the fire performance of CFST columns strengthened by FRP. The results of fire endurance tests on FRP-strengthened circular CFST columns are presented. Failure modes of the specimens after exposure to fire, temperatures in the cross section, axial deformation and fire resistance of the composite columns are analysed. It is demonstrated that the required fire endurance can be achieved if the strengthened composite columns are appropriately designed.

Modeling and performance evaluation of a piezoelectric energy harvester with segmented electrodes

  • Wang, Hongyan;Tang, Lihua;Shan, Xiaobiao;Xie, Tao;Yang, Yaowen
    • Smart Structures and Systems
    • /
    • v.14 no.2
    • /
    • pp.247-266
    • /
    • 2014
  • Conventional cantilevered piezoelectric energy harvesters (PEHs) are usually fabricated with continuous electrode configuration (CEC), which suffers from the electrical cancellation at higher vibration modes. Though previous research pointed out that the segmented electrode configuration (SEC) can address this issue, a comprehensive evaluation of the PEH with SEC has yet been reported. With the consideration of delivering power to a common load, the AC outputs from all segmented electrode pairs should be rectified to DC outputs separately. In such case, theoretical formulation for power estimation becomes challenging. This paper proposes a method based on equivalent circuit model (ECM) and circuit simulation to evaluate the performance of the PEH with SEC. First, the parameters of the multi-mode ECM are identified from theoretical analysis. The ECM is then established in SPICE software and validated by the theoretical model and finite element method (FEM) with resistive loads. Subsequently, the optimal performances with SEC and CEC are compared considering the practical DC interface circuit. A comprehensive evaluation of the advantageous performance with SEC is provided for the first time. The results demonstrate the feasibility of using SEC as a simple and effective means to improve the performance of a cantilevered PEH at a higher mode.

Fault Diagnosis of Transformer Based on Self-powered RFID Sensor Tag and Improved HHT

  • Wang, Tao;He, Yigang;Li, Bing;Shi, Tiancheng
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2134-2143
    • /
    • 2018
  • This work introduces a fault diagnosis method for transformer based on self-powered radio frequency identification (RFID) sensor tag and improved Hilbert-Huang transform (HHT). Consisted by RFID tag chip, power management circuit, MCU and accelerometer, the developed RFID sensor tag is used to acquire and wirelessly transmit the vibration signal. A customized power management including solar panel, low dropout (LDO) voltage regulator, supercapacitor and corresponding charging circuit is presented to guarantee constant DC power for the sensor tag. An improved band restricted empirical mode decomposition (BREMD) which is optimized by quantum-behaved particle swarm optimization (QPSO) algorithm is proposed to deal with the raw vibration signal. Compared with traditional methods, this improved BREMD method shows great superiority in reducing mode aliasing. Then, a promising fault diagnosis approach on the basis of Hilbert marginal spectrum variations is brought up. The measured results show that the presented power management circuit can generate 2.5V DC voltage for the rest of the sensor tag. The developed sensor tag can achieve a reliable communication distance of 17.8m in the test environment. Furthermore, the measurement results indicate the promising performance of fault diagnosis for transformer.

A New Operator Extracting Image Patch Based on EPLL

  • Zhang, Jianwei;Jiang, Tao;Zheng, Yuhui;Wang, Jin;Xie, Jiacen
    • Journal of Information Processing Systems
    • /
    • v.14 no.3
    • /
    • pp.590-599
    • /
    • 2018
  • Multivariate finite mixture model is becoming more and more popular in image processing. Performing image denoising from image patches to the whole image has been widely studied and applied. However, there remains a problem that the structure information is always ignored when transforming the patch into the vector form. In this paper, we study the operator which extracts patches from image and then transforms them to the vector form. Then, we find that some pixels which should be continuous in the image patches are discontinuous in the vector. Due to the poor anti-noise and the loss of structure information, we propose a new operator which may keep more information when extracting image patches. We compare the new operator with the old one by performing image denoising in Expected Patch Log Likelihood (EPLL) method, and we obtain better results in both visual effect and the value of PSNR.

Novel Passive Snubber Suitable for Three-Phase Single-Stage PFC Based on an Isolated Full-Bridge Boost Topology

  • Meng, Tao;Ben, Hongqi;Wang, Daqing;Song, Jianfeng
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.264-270
    • /
    • 2011
  • In this paper a novel passive snubber is proposed, which can suppress the voltage spike across the bridge leg of the isolated full-bridge boost topology. The snubber is composed of capacitors, inductors and diodes. Two capacitors connected in series are used to absorb the voltage spike and the energy of each capacitor can be transferred to the load during one switching cycle by the resonance of the inductors and capacitors. The operational principle of the passive snubber is analyzed in detail based on a three-phase power factor correction (PFC) converter, and the design considerations of both the converter and the snubber are given. Finally, a 3kW laboratory-made prototype is built. The experimental results verify the theoretical analysis and evaluations. They also prove the validity and feasibility of the proposed methods.

Discussion on the Technology Route for Land Degradation Monitoring and Assessment based on 3S Technique

  • Jing, Wang;Ting, He;Zhang, Ji-Xian;Li, Hai-Tao
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.757-765
    • /
    • 2002
  • This paper analyzes three theories for land degradation assessment and internationl/domestic methods for land degradation monitoring and assessment. Under the guidance of absolute degradation thought, this paper proposes the technological framework for monitoring and appraising cultivated land degradation based on the 3S technique. We can apply 3S technique and analyze the nature, the environmental, the social, and the economic elements which influence the land utilization and degradation synthetically, to set up the indicator system of the cultivated land degradation monitoring and assessment based on 3S technique; to propose the degradation information extraction methods based on 3S technique; to create the quantitative assessment model and method for land degradation; to analyze the ecological environment response of land use and degradation quantitatively; and to propose the measure, policy and suggestion for solving the land degradation problem from the point of view of land utilization.

  • PDF

Ginkgolide B Modulates BDNF Expression in Acute Ischemic Stroke

  • Wei, Hu;Sun, Tao;Tian, Yanghua;Wang, Kai
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.391-396
    • /
    • 2017
  • Objective : To investigate the neuroprotective effects of Ginkgolide B (GB) against ischemic stroke-induced injury in vivo and in vitro, and further explore the possible mechanisms concerned. Methods : Transient middle cerebral artery occlusion (tMCAO) mice and oxygen-glucose deprivation/reoxygenation (OGD/R)-treated N2a cells were used to explore the neuroprotective effects of GB. The expression of brain-derived neurotrophic factor (BDNF) was detected via Western blot and qRT-PCR. Results : GB treatment (4 mg/kg, i. p., bid) significantly reduced neurological deficits, water content, and cerebral infarct volume in tMCAO mice. GB also significantly increased Bcl-2/Bax ratio, reduced the expression of caspase-3, and protected against OGD/R-induced neuronal apoptosis. Meanwhile, GB caused the up-regulation of BDNF protein in vivo and in vitro. Conclusion : Our data suggest that GB might protect the brain against ischemic insult partly via modulating BDNF expression.

Antiferroelectric and antiferrodistortive phase transitions in Ruddlesden-Popper Pb2TiO4 from first-principles

  • Xu, Tao;Shimada, Takahiro;Wang, Jie;Kitamura, Takayuki
    • Coupled systems mechanics
    • /
    • v.6 no.1
    • /
    • pp.29-40
    • /
    • 2017
  • This work employed density functional theory to investigate the structural and ferroelectric properties of the Ruddlesden-Popper (RP) phase of lead titanate, $Pb_2TiO_4$, as well as its phase transitions with epitaxial strain. A wealth of novel structural instabilities, which are absent in the host $PbTiO_3$ material, were identified in the RP phase through phonon soft-mode analysis. Our calculations showed that the ground state of $Pb_2TiO_4$ is antiferroelectric, distinct from the dominant ferroelectric phase in the corresponding host material. In addition, applied epitaxial strain was found to play a key role in the interactions among the instabilities. The induction of a sequence of antiferroelectric and antiferrodistortive (AFD) phase transitions by epitaxial strain was demonstrated, in which the ferroic instability and AFD distortion were cooperative rather than competitive, as is the case in the host $PbTiO_3$. The RP phase in conjunction with strain engineering thus represents a new approach to creating ferroic orders and modifying the interplay among structural instabilities in the same constituent materials, enabling us to tailor the functionality of perovskite oxides for novel device applications.

Calculation of Leakage Inductance of Integrated Magnetic Transformer with Separated Secondary Winding Used in ZVS PSFB Converter

  • Tian, Jiashen;Zhang, Yiming;Ren, Xiguo;Wang, Xuhong;Tao, Haijun
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.644-651
    • /
    • 2016
  • A novel zero voltage switching (ZVS) phase shift full bridge (PSFB) converter used in geophysical exploration is proposed in this paper. To extend the ZVS ranges and increase power density of the converter, external inductor acting as leakage inductance is applied and integrated into the integrated magnetic (IM) transformer with separated secondary winding. Moreover, the loss of ZVS PSFB converter is also decreased. Besides, the analysis and accurate prediction methodology of the leakage inductance of the IM transformer are proposed, which are based on magnetic energy and Lebedev. Finally, to verify the accuracy of analysis and methodology, the experimental and finite element analysis (FEA) results of IM transformer and 40 kW converter prototypes are given.

Uncertainty Analysis of Dynamic Thermal Rating of Overhead Transmission Line

  • Zhou, Xing;Wang, Yanling;Zhou, Xiaofeng;Tao, Weihua;Niu, Zhiqiang;Qu, Ailing
    • Journal of Information Processing Systems
    • /
    • v.15 no.2
    • /
    • pp.331-343
    • /
    • 2019
  • Dynamic thermal rating of the overhead transmission lines is affected by many uncertain factors. The ambient temperature, wind speed and wind direction are the main sources of uncertainty. Measurement uncertainty is an important parameter to evaluate the reliability of measurement results. This paper presents the uncertainty analysis based on Monte Carlo. On the basis of establishing the mathematical model and setting the probability density function of the input parameter value, the probability density function of the output value is determined by probability distribution random sampling. Through the calculation and analysis of the transient thermal balance equation and the steady- state thermal balance equation, the steady-state current carrying capacity, the transient current carrying capacity, the standard uncertainty and the probability distribution of the minimum and maximum values of the conductor under 95% confidence interval are obtained. The simulation results indicate that Monte Carlo method can decrease the computational complexity, speed up the calculation, and increase the validity and reliability of the uncertainty evaluation.