• Title/Summary/Keyword: Wall Type Apartment

Search Result 113, Processing Time 0.022 seconds

Influence of spacing between buildings on wind characteristics above rural and suburban areas

  • Kozmar, Hrvoje
    • Wind and Structures
    • /
    • v.11 no.5
    • /
    • pp.413-426
    • /
    • 2008
  • A wind tunnel study has been carried out to determine the influence of spacing between buildings on wind characteristics above rural and suburban type of terrain. Experiments were performed for two types of buildings, three-floor family houses and five-floor apartment buildings. The atmospheric boundary layer (ABL) models were generated by means of the Counihan method using a castellated barrier wall, vortex generators and a fetch of roughness elements. A hot wire anemometry system was applied for measurement of mean velocity and velocity fluctuations. The mean velocity profiles are in good agreement with the power law for exponent values from ${\alpha}=0.15$ to ${\alpha}=0.24$, which is acceptable for the representation of the rural and suburban ABL, respectively. Effects of the spacing density among buildings on wind characteristics range from the ground up to $0.6{\delta}$. As the spacing becomes smaller, the mean flow is slowed down, whilst, simultaneously, the turbulence intensity and absolute values of the Reynolds stress increase due to the increased friction between the surface and the air flow. This results in a higher ventilation efficiency as the increased retardation of horizontal flow simultaneously accompanies an intensified vertical transfer of momentum.

Overall Heat Transfer Coefficients and Thermal Performance Evaluation through Heat Flux Measurement at Nakseonjae in Changdeokgung (창덕궁 낙선재 외피 열류량 실측을 통한 열관류율 산정 및 열 성능 해석)

  • Kim, Min-Hwi;Kim, Jin-Hyo;Kwon, Oh-Hyun;Han, Wook;Jeong, Jae-Weon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.190-195
    • /
    • 2008
  • The objective of this research is to determine overall heat transfer coefficients (K-value) of exterior wall, floor, and roof of Nakseonjae, a Korean traditional residence via field measurement of transient heat flow and temperature difference across each envelope component. Heat flow sensors and T-type thermocouple were attached on the internal and the external surface of each building component, and real-time measurement data were collected for the three consecutive summer days. The K-values determined in this research showed good agreement with other results from open literature. Peak and annual thermal loads of the traditional residence estimated by a commercial energy simulation program were compared with those for a current apartment house. The traditional house showed lower annual cooling load than that of the current building. It may caused by the fact that the traditional building has less air-tight envelopes and no fenestration passing direct solar radiation into the space.

  • PDF

The Research on the Preference in Bathroom Design According to Residents' Lifestyle Types - Focus on Residents in Medium Size Apartments in Seoul - (라이프스타일 유형별로 파악한 욕실디자인 선호도 조사 - 서울지역 중형아파트 거주자를 대상으로 -)

  • Hwang, Yun-Jung;Shin, Kyung-Joo
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.1
    • /
    • pp.154-164
    • /
    • 2011
  • The purpose of this study is to identify more types of residents in medium-sized apartments in Seoul by lifestyle that has been used as a variable of space planning and to investigate and present bathroom design appropriate for characteristics of each resident type. The article examines the general characteristics, lifestyle types, and preference for the bathroom design. A total of 642 samples, acquired via internet survey, were analyzed with the statistical computer program SPSS PC+ window version 16.0. The conclusion of the article are as follows: 1) The lifestyle of users living in medium-sized apartments are categorized into 4 types: trend seeking, aesthetic seeking, family seeking, information seeking types. 2) The preference for the bathroom design of trend seeking type, the toilet is a bidet-builtin type and the washstand is a semi-counter type and the bathtub is a spa type and the shower booth is a bathtub-extending type. The storage closet is a upper-fixed type with two sides, the finishing materials are tiles and PVC monorium, and light built in a wall. 3) The preference for the bathroom design of aesthetic seeking type, the toilet is a bidet-builtin type and the washstand is a semi-counter type and the bathtub is a whirlpool type and the shower booth is a steam-sauna type. The storage closet is a upper-fixed with one side and opened closet, the finishing materials are tiles. 4) The preference for the bathroom design of family seeking type, the toilet is a bidet-builtin type and the washstand is a stand type and the bathtub is a reclamation type and the shower booth is a partition type. The storage closet is a upper-fixed with three sides. 5) The preference for the bathroom design of information seeking type, the toilet is a bidet-builtin type and the washstand is a semi-counter and the bathtub is a spa type and the shower booth is a partition type. The storage closet is a upper-fixed type with two sides. The results of this study may be used as basic data in planning bathroom design for housing supply for housing suppliers, and used as significant information for residents to identify their own types that can be referred when they select apartments to live in.

Seismic Performance Preliminary Evaluation Method of Reinforced Concrete Apartments with Bearing Wall system (기존 철근콘크리트 벽식 공동주택의 내진 성능 예비 평가법에 관한 연구)

  • Chung, Lan;Woo, Sung-Sik;Choi, Ki-Young;Park, Tae-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.293-300
    • /
    • 2007
  • In Korea, the seismic design regulations was established since 1988 about regularity scale of structures. However, It was not established about seismic performance and evaluation method as the most existing buildings was constructed before Earthquake-Resistant Design(1988). In this study, for model structures which are 4 units of non-seismic designed apartment and 3 units of seismic designed in Korea performed seismic performance evaluation by suggested KISTC (2004). And the result compare to evaluate Capacity Spectrum Method by using MIDAS Gen and SDS. As a result, we observed that suggested KISTC's method have overestimated for shear stress and drift index. The purpose of this study provides most conformity seismic performance evaluation process and the appropriate method of calculating the seismic performance index in Korea.

A Study on Seismic Restraint of Korean Type Building Gas Piping (한국형 건축물 가스 배관의 내진 고정장치에 관한 연구)

  • Lim, Geon-Tae;Lim, Sang-Ho
    • Industry Promotion Research
    • /
    • v.4 no.1
    • /
    • pp.11-20
    • /
    • 2019
  • This study relates to a fixing device for gas piping installed in a building such as an apartment or a building. The gas piping is fixed to the inside of the housing so as to buffer the gas piping in all directions, thereby relieving vibration caused by an earthquake or an impact, Disclosed is an earthquake-proof fixing device for a gas pipeline that can minimize damages caused by damage to an earthquake and a gas pipeline by preventing damage and breakage. An apparatus for fixing a gas pipe to a bracket provided on a wall or a wall of a building, the apparatus comprising: a housing coupled to a wall or a bracket and coupled to the inside of the housing; a gas pipe penetrating through the housing to fix the gas pipe; The first plate spring includes a first plate spring formed with a plurality of concave-convex portions that are elastically supported in four directions. The first plate spring is screwed to the front surface or the rear surface of the housing. The lower plate is coupled to one end and the other end, And a pair of first adjusting screws for adjusting the elastic force of the spring. Through this study, damage and damage of gas piping due to earthquake or impact can be minimized.

Research of Wall Storage System design process for residential space (주문형 주거공간에서 Wall Storage System을 활용한 가변화 방안 연구)

  • 임은상
    • Archives of design research
    • /
    • v.13 no.3
    • /
    • pp.281-292
    • /
    • 2000
  • Today, the rapid economic growth and emerging new trends have been changed radically throughout the society and they especially have affected the changes of life-style and the diversity of residents'demands in housing life. This changes of life have brought the shift in family form from traditional type, thus new phase of nuclear family means that it makes on the whole, variable family forms such as single family, non-blood one, a generation one and so on. It therefore is time that we should not only explore current housing plans, but envisage concept of new living space to satisfy latent need of the occupants. But the forms, in spite of the diversity of user's needs and the change of life-style, of many houses as many apartment and tenement houses supplied so far have been clearly limted, and housing policy of the mass-supply causes monotonous space composition, over-occupation and non-changeability. Now, the collective houses have some limits owing to the commoness and assemblage, but they have failed to keep up with the variable and changeable life-style of residents. These problems, to put it concretely, lead to increasing needs for the number of rooms in proportion to family members, for the change of behavior using the space. We therefore need to propose the new living space. As the current plans for designing house are based on the average life-style of people, they can not cope with variable demands of the resident. For that reason, this paper will propose the manual space system as an alternative for it and the goal is to suggest new furniture system which we need to create the flexibility of living space.

  • PDF

Behaviour of Shear Wall Structures with Energy Dissipation Device in Coupling Beam (연결보에 감쇠장치를 적용한 전단벽식 구조물의 거동특성)

  • Kim, Jin-Sang;Yoon, Tae-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.21-30
    • /
    • 2018
  • Building structures of apartment in korea conventionally adopt shear walls using coupling beams as seismic force-resisting systems. Energy dissipating devices employed the building structures are used instead of the coupling beams in order to increase the seismic performances by providing additional damping and stiffness. This study aims to introduce energy dissipating devices which are preferred in structural system and aims to investigate structural behaviors of shear wall structures employing such devices instead of coupling beams. In order for achieve research objectives, Finite Element Analysis and Nonlinear analysis was carry out. Finite Element Analysis results was correspond with experimental results and this is indicated that the device can provide sufficient additional damping and stiffness into shear wall structures. Throughout nonlinear static analyses, examples structures with the devices can enhance seismic performance of building structures due to their sufficient energy dissipating capacities. Especially, strength and ductility capacities were significantly improved when it is compared with the performance of building structures without the devices. Throughout nonlinear dynamic analyses, it was observed that structural damages can be mitigated due to reduced seismic demands for seismic force-resisting systems. It is especially noted due to the fact that story drifts, accelerations, shear demands are reduced by 15~18%, 20~28% and 15~20%, respectively.

A Study on the Structure Types and Concrete Strength Zoning of Domestic Tall Apartment Buildings (국내 초고층 주상복합 건축물의 구조시스템 유형과 콘크리트 강도 조닝 분석)

  • Kim, Sang-Yeon
    • Land and Housing Review
    • /
    • v.4 no.3
    • /
    • pp.295-301
    • /
    • 2013
  • In this study, cases of domestic tall residential buildings were investigated for the structural types, numbers of stories, total heights, type of lateral load resisting systems, and zoning of concrete strength. Based on these investigation data, the structural planning pattern of tall residential building was analyzed. SRC structure is main structural types of tall residential building at the initial stage of domestic tall residential building, but RC structure is substituted for main structural types since 2005. Retaining wall system is positioned at the core part of structural plan as a lateral load resisting system. Concrete strength zoning of vertical members like columns are divided by vertical heights of lower parts, middle parts, and upper parts. Basic data of structural planning of 40stories and 60 stories residential buildings was proposed based on case investigation.

A Study on the Spatial Elements of Flexible Apartments - Focusing on Local and Foreign Flexible Apartments - (가변형 공동주택의 공간 요소 특성 연구 - 국내외 가변형 공동주택을 중심으로 -)

  • Cho, Il-A;Park, Kyung-Hwan;Kim, Hyung-Woo
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.3 s.62
    • /
    • pp.66-75
    • /
    • 2007
  • In this study, by comparing the development and the space types of local and foreign flexible apartments, basic data will be derived for the development of various flexible types of apartments in Korea. A total of 60 unit plans, including 30 domestic cases and 30 overseas cases of flexible apartments, are analyzed for this study. In terms of the unit plan types, Korean apartments usually had a wide front bay with shallow depth, placing more rooms on the front bay; whereas foreign apartments tend to have various unit plan types: (1) a narrow front bay with deep depth, (2) a wide front bay with shallow depth, and (3) variegated open-plan types. Many apartments in foreign countries had a double-layered structure with the. upstairs and downstairs areas. In terms of the flexible types, many Korean apartments achieved interior flexibility using non-bearing wall or sliding doors; whereas foreign apartments had a flexible space by separating the support elements and the infill elements. There was found to be a close relationship between the location of support elements and the variability of unit plans. Support elements can be placed largely into three locations: (1) Between the front side bay and the rear side bay, (2) in the center bay of a unit plan, and (3) others. Depending on the location of support elements, various types of flexible unit plans can be created. Through a comparative analysis of domestic and foreign apartments, basic data that can be used for developing various flexible unit plans was derived.

A study on the Residential Satisfaction of Environmental Condition for Housing Complexes located in Coastal Areas (연안역에 입지하는 주거단지 생활자의 거주환경 만족도에 관한 연구)

  • Lee, Myung-Kwon
    • Journal of Navigation and Port Research
    • /
    • v.32 no.6
    • /
    • pp.505-513
    • /
    • 2008
  • Regarding the developmental plans for the coastal areas and marine architectures, this study deal with the overall planning of apartment complexes in waterfront areas, focusing upon the analysis of their comfort and convenience factors from the perspective of the potential residence. It also analysis the intra-complex comfort and satisfaction conditions in terms of their floor-by-floor, directional. and location factors. The results of the study are as follows: 1) The order of respondents' preference on directional factor has been found to be: South > Southeast > Southwest > East > others. 2) 67% of the people surveyed on scenery responded that outward view is considered more significant than the directional factor. 3) A comprehensive analysis of floor zone-specific view preference shared that there were only minor differences among quay wall, arc, and river-seashore types. The impact of the characteristics of the marine environments turned out to be a greater point of consideration; showing that the other of floor-preference is: high-level > ultra-high level > middle level > low level.