• 제목/요약/키워드: Wall Air Cavity

검색결과 77건 처리시간 0.021초

일사열 배제를 위한 통기벽체 적정 길이에 대한 검토 (A Study on the optimal length of air cavity for Solar heat removal with Air-Vent System)

  • 김상진;금종수;최광환;신병환;정용현
    • 한국태양에너지학회 논문집
    • /
    • 제24권2호
    • /
    • pp.33-38
    • /
    • 2004
  • Outside wall systems we lost much energy from the dew of thermal bridge and unsuitable adiabatic construction. The air vent wall system can make reduce cooling loads from the outside wall in summer. The basic concept is connected with buoyant force by the difference of density. An external surface of a wall absorbs solar radiation, and transfers it to the air in the cavity. The warmed air gets buoyant force. So the warmed air is released through the top opening and cooler outside air replaces the space in the cavity. So because of the cavity and the openings, the cooling load reduction by natural ventilation is believed to be considerable. The purpose of this study is finding optimal length of air cavity by numerical analyses.

커튼월의 단열 향상 및 결로 방지를 위한 통기구조 적용방안 연구 (Application of Ventilated Cavity for Enhancing Insulation and Preventing Condensation of Curtain-wall System)

  • 이선우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.21-28
    • /
    • 2017
  • Curtain-wall systems have been widely applied to buildings because of their lightweight and constructability characteristics. However, as curtain-wall systems include many building materials, vapor barriers can become damaged and condensation can occur. Due to the material properties of stone curtain-walls, the external appearance and structure of a building could be damaged and the insulating performance of the curtain-wall could be worse. Natural ventilation using an air cavity in a curtain-wall is expected to be effective for the prevention of condensation in inner walls and for the reduction of building cooling energy use in the summer. The purpose of this experimental study is to analyze the influence of a ventilated cavity on the insulating performance of a curtain-wall and the ventilated cavity depth and ratio of top opening needed to prevent condensation in a curtain-wall.

통기벽체적용 건물에서의 일사열 제거효과 검토 (A Study of Solar heat removal Impact with Air-Vent Wall)

  • 김상진;금종수;최광환;신병환;정용현
    • 한국태양에너지학회 논문집
    • /
    • 제24권2호
    • /
    • pp.25-31
    • /
    • 2004
  • Ventilation through air vent system in a building envelope is expected to be an effective measure to release solar radiation. An external surface of a wall absorbs solar radiation and transfers it to the air in the cavity. The warmed air gets buoyant force. So when openings are provided at the top and bottom of the cavity, the warmed air is released through the top opening and cooler outside air replaces the space in the cavity. This reduces the further heat transmission into the built environment. This natural ventilation effect seems to be steady and strong. So because of the cavity and the openings, the cooling load reduction by natural ventilation is believed to be considerable.

건축물 외부 중공벽의 시공방안에 관한 연구 - 외부 점토벽돌의 사용을 중심으로 - (A study on the technical details of masonry veneer and cavity walls - Focused on the out wyth of clay bricks -)

  • 양순갑
    • 한국주거학회논문집
    • /
    • 제8권3호
    • /
    • pp.219-230
    • /
    • 1997
  • Lack of technical standards, specification and inadequate execution in masonry wall construction in Korea lead to produce serious flaw problems such as crack, efflorescene, and upset etc.. The purpose of this paper is to present the practical details for Masonry cavity wall construction to prevent rain penetration and to accommodate differential movement between the inner and outer wythes of cavity walls. Considering rain penetration and differential movement of both wythes of cavity walls, provision of an adequate air space, an airtight back-up wall, clean cavity with weepholes and vents, properly positioned flashing, tie and shelf angle etc. depend on the cavity wall types will help ensure good performance. The present details included noncorrosive hot dip galvanized steel or stainless steel for metal components, plastic and ultra violet resistant polypropylene Copolymer for other components was taken into account the construction method and several types of cavity walls in Korea

  • PDF

캐비티내에서 표면복사를 고려한 2차원 층류 자연대류 열전달 (Two-Dimensional Laminar Natural Convection Heat Transfer with Surface Radiation in a Cavity)

  • 박희용;박경우;한철희
    • 설비공학논문집
    • /
    • 제4권3호
    • /
    • pp.217-232
    • /
    • 1992
  • A Numerical study on two-dimensional laminar natural convection with and without surface radiation in fully or partially open square cavity was performed. The cavity has one vertical heated wall facing a vertical opening and two horizontal insulated walls. The pressure boundary condition was applied to the opening instead of the velocity boundary condition. The results of this study showed that the increase of partition length decreased the convective and the radiative Nusselt numbers. It was also found that the increase of wall emissivity decreased the convective Nusselt numbers but increased the radiative Nusselt numbers.

  • PDF

상부가 개방된 수직 캐비티내에 장착된 불연속 균일 발열체의 자연대류 냉각 (Natural convection cooling of discrete heaters with same heat generation in a vertical open top cavity)

  • 유갑종;추홍록;김병하;최병철
    • 대한기계학회논문집B
    • /
    • 제21권1호
    • /
    • pp.1-14
    • /
    • 1997
  • Natural convection cooling of discrete heaters located in a two-dimensional vertical open top cavity is investigated experimentally. The five discrete heaters with same heat generation are located on the wall of the cavity. The heaters are arranged in two configurations; flush-mounted on a vertical wall and protruding from the wall about 4.5 mm. The materials used for the vertical walls are copper and epoxy-resin, and air is used as the cooling fluid. The temperature and flow fields in the cavity were visualized by means of Mach-Zehnder interferometer and smoke-method. Also, local temperature measurements are made along the vertical wall. Results are obtained for cavity aspect ratios of 4.6, 7.5 and 9.5 and modified Rayleigh numbers ranging from 10$^{3}$ to 10$^{6}$ . Results indicate that the cooling efficiency for the copper wall is superior to that of the epoxy-resin. For the epoxy-resin wall, the protrusion of the heaters plays a role in decreasing the heat transfer performance. The location of maximum temperature is significantly influenced by the wall materials and heater configurations. Correlations relating the Nusselt number to the modified Rayleigh number are proposed.

TLC 를 이용한 사각공동내의 열전도 영역에 기포의 형성으로 인한 열전달 현상 구명 (A Study of Heat Transfer Phenomena due to a Formed Gas Bubble under Heat-Conduction Domain in A Closed Square Cavity)

  • 엄용균;유재봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.85-89
    • /
    • 2003
  • In a closed square cavity filled with a liquid, a cooled the upper horizontal wall and a heated the lower horizontal wall, the flow isn't generated under the ground-based condition when Rayleigh number is lower than 1700. In such case the flow phenomena near an air bubble under a cooled horizontal wall were investigated. The temperature and the flow fields were studied by using the Thermo-sensitive Liquid-Crystal and the image processing. The qualitative analysis for the temperature and the flow fields were carried out by applying the image processing technique to the original data. Injecting bubble at the center point of upper cooled wall, the symmetry shape of two vortexes near an air bubble was observed. The bubble size increased, the size of velocity and the magnitude of velocity increased. In spite of elapsed time, a pair of two vortexes was the unique and steady-state flow in a square cavity and wasn't induce to the other flow in the surround region.

  • PDF

直接噴射式 디이젤機關의 燃燒室形狀과 火焰의 發達 (The effect of air and spray turbulence in a D.I. diesel engine on the flame progress)

  • 방중철;태전간랑
    • 대한기계학회논문집
    • /
    • 제11권1호
    • /
    • pp.44-52
    • /
    • 1987
  • 본 논문에서는 앞서의 연구들에서 얻은 연구성과를 실제의 디이젤기관에 적용 시켜 화염의 발달상태와 기관속도의 상승 등을 고찰하여, 그 유효성을 평가했다. 또 고온공기류덕트에서는 실험하기가 곤란했던, 분무자체에 족회운동을 일으킨 경우의 연 소과정에 대해서도 피스톤요부의 벽면에 충돌하는 분무의 각도를 변화시켜, 고속도 화 염사진으로 부터 검토했다.

지하공동 모델의 전기비저항 특성에 관한 실험적 연구

  • 박갑진;김현수;김현승;송영수
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2009년도 학술대회 초록집
    • /
    • pp.93-98
    • /
    • 2009
  • 지하공동의 상태를 명확히 영상화하기 위해서는 지하공동의 물성분포에 대한 이해가 우선적으로 되어야 한다. 이 실험에서는 지하공동이 공기 또는 지하수로 적당 비율로 채워져 있음을 가정하고 이에 따른 전기비저항적 특성을 파악하고자 하였다. 또한 지하공동 외벽의 건조 상태가 전기비저항 탐사에 영향을 미칠 것이므로 공동 외벽을 젖었다고 가정한 상태에서 수조 모형실험을 수행하였다. 지하공동 모델은 한천을 이용하여 제작하였으며($33.5{\Omega}m$), 배경매질은 상수도물($100{\Omega}m$)을 사용하였다. 실험결과 외벽이 젖은 상태에서 공기/물의 비율이 낮은 경우에는 저비저항 이상대가 나타나나, 공기/물의 비율이 높아지면서 점점 고비저항 이상대가 나타남을 알 수 있었다.

  • PDF

상부가 개방된 수직 캐비티내의 한쪽면에 배열된 다양한 발열조건을 갖는 발열체의 최적배열 (The optimal array of various heat-generating heaters located on one wall of a vertical open top cavity)

  • 유갑종;추홍록;최병철
    • 대한기계학회논문집B
    • /
    • 제21권1호
    • /
    • pp.15-23
    • /
    • 1997
  • An experimental investigation of two-dimensional steady natural convection cooling in a vertical open top cavity with conducting side walls of finite thickness is presented. The various heat-generating discrete heaters are located on one vertical wall of the cavity. When each heater dissipates different amount of power, the purpose of the work is to obtain the optimal array condition of the heaters. The four cases of non-uniform heating conditions are considered. The temperature fields in the cavity were visualized by the interferometer and local temperatures of the vertical wall were measured by thermocouples. The heaters were arranged in two configurations: flush-mounted on a vertical wall or protruding from the wall about 4.5 mm. The vertical wall was constructed out of copper or epoxy-resin sheet. Experiments have been conducted for air with constant Prandtl number(Pr=0.7), the aspect ratio of 4.6, 7.5, 9.5, power input in the range of 0.9 W ~ 4.2 W. For the enhancement of the cooling effectiveness, the upper and lower of vertical wall would give the better position for the heaters of higher heat flux.