• 제목/요약/키워드: Wafer Profile

검색결과 107건 처리시간 0.028초

대기압 플라즈마를 이용한 P타입 태양전지 웨이퍼 도핑 연구 (Study of P-type Wafer Doping for Solar Cell Using Atmospheric Pressure Plasma)

  • 윤명수;조태훈;박종인;김상훈;김인태;최은하;조광섭;권기청
    • Current Photovoltaic Research
    • /
    • 제2권3호
    • /
    • pp.120-123
    • /
    • 2014
  • Thermal doping method using furnace is generally used for solar-cell wafer doping. It takes a lot of time and high cost and use toxic gas. Generally selective emitter doping using laser, but laser is very high equipment and induce the wafer's structure damage. In this study, we apply atmospheric pressure plasma for solar-cell wafer doping. We fabricated that the atmospheric pressure plasma jet injected Ar gas is inputted a low frequency (1 kHz ~ 100 kHz). We used shallow doping wafers existing PSG (Phosphorus Silicate Glass) on the shallow doping CZ P-type wafer (120 ohm/square). SIMS (Secondary Ion Mass Spectroscopy) are used for measuring wafer doping depth and concentration of phosphorus. We check that wafer's surface is not changed after plasma doping and atmospheric pressure doping width is broaden by increase of plasma treatment time and current.

CMP 패드 강성에 따른 산화막 불균일성(WIWNU)에 관한 연구 (A Study on the Within Wafer Non-uniformity of Oxide Film in CMP)

  • 박기현;정재우;박범영;서헌덕;이현섭;정해도
    • 한국전기전자재료학회논문지
    • /
    • 제18권6호
    • /
    • pp.521-526
    • /
    • 2005
  • Within wafer non-uniformity(WIWNU) improves as the stiffness of pad decrease. We designed the pad groove to study of pad stiffness on WIWNU in Chemical mechanical polishing(CMP) and measured the pad stiffness according to groove width. The groove influences effective pad stiffness although original mechanical properties of pad are unchanged by grooving. Also, it affects the flow of slurry that has an effect on the lubrication regime and polishing results. An Increase of the apparent contact area of pad by groove width results in decrease of effective pad stiffness. WIWNU and profile of removal tate improved as effective pad stiffness decreased. Because grooving the pad reduce its effective stiffness and it makes slurry distribution to be uniform. Futhermore, it ensures that pad conforms to wafer-scale flatness variability. By grooving the top pad, it is possible to reduce its stiffness and hence reduce WIWNU and edge effect.

The Effect of Gamma Irradiation on PLGA and Release Behavior of BCNU from PLGA Wafer

  • Lee, Jin-Soo;Chae, Gang-Soo;Gilson Khang;Kim, Moon-Suk;Cho, Sun-Hang;Lee, Hai-Bang
    • Macromolecular Research
    • /
    • 제11권5호
    • /
    • pp.352-356
    • /
    • 2003
  • The objectives of this study were to investigate the influence of gamma irradiation for sterilization on poly(D,L-lactide-co-glycolide) (PLGA) with different molecular weight and the effect of gamma irradiation on the release behavior of 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU, carmustine) from PLGA wafer with various irradiation doses. The effect of gamma irradiation on PLGA was evaluated by gel permeation chromatography (GPC), differential scanning calorimetry (DSC), and electron paramagnetic resonance (EPR). The weight average molecular weight (M$_{w}$) and glass transition temperature (T$_{g}$) of PLGA decreased after gamma irradiation. The extent of M$_{w}$ reduction was dependent on irradiation dose and PLGA molecular weight. Using EPR spectroscopy, we successfully detected gamma irradiation induced free radicals in PLGA. The gamma irradiation increased the release rate of BCNU from PLGA wafer at applied irradiation doses except 2.5 Mrad of irradiation dose in this study.study.

Ti 쇼트키 배리어 다이오드의 Al 확산 방지를 위한 SC-1 세정 효과 (Effect of SC-1 Cleaning to Prevent Al Diffusion for Ti Schottky Barrier Diode)

  • 최진석;최여진;안성진
    • 한국재료학회지
    • /
    • 제31권2호
    • /
    • pp.97-100
    • /
    • 2021
  • We report the effect of Standard Clean-1 (SC-1) cleaning to remove residual Ti layers after silicidation to prevent Al diffusion into Si wafer for Ti Schottky barrier diodes (Ti-SBD). Regardless of SC-1 cleaning, the presence of oxygen atoms is confirmed by Auger electron spectroscopy (AES) depth profile analysis between Al and Ti-silicide layers. Al atoms at the interface of Ti-silicide and Si wafer are detected, when the SC-1 cleaning is not conducted after rapid thermal annealing. On the other hand, Al atoms are not found at the interface of Ti-SBD after executing SC-1 cleaning. Al diffusion into the interface between Ti-silicide and Si wafer may be caused by thermal stress at the Ti-silicide layer. The difference of the thermal expansion coefficients of Ti and Ti-silicide gives rise to thermal stress at the interface during the Al layer deposition and sintering processes. Although a longer sintering time is conducted for Ti-SBD, the Al atoms do not diffuse into the surface of the Si wafer. Therefore, the removal of the Ti layer by the SC-1 cleaning can prevent Al diffusion for Ti-SBD.

쵸크랄스키법에서 온도 프로파일에 대한 충진사이즈의 효과에 대한 이해 (Understanding of the effect of charge size to temperature profile in the Czochralski method)

  • 백성선;권세진;김광훈
    • 한국결정성장학회지
    • /
    • 제28권4호
    • /
    • pp.141-147
    • /
    • 2018
  • 태양광 에너지는 깨끗하며 무한한 재생에너지의 한가지로 많은 관심을 받아왔다. 태양광 에너지는 다결정 실리콘 웨이퍼 혹은 단결정 실리콘 웨이퍼로 구성된 솔라셀에 의해서 전기에너지로 전환된다. 제조원가를 낮추기 위하여 한 개의 석영 도가니에 폴리실리콘의 충진 크기를 증가시키는 연구가 많이 개발되어 왔다. 충진 크기를 증가시키면, 쵸크랄스키 공정장비의 온도제어가 강한 멜트 대류 때문에 힘들어진다. 본 연구에서는 20 inch와 24 inch 석영도가니와 90 Kg, 120 Kg, 150 Kg, 200 Kg, 250 Kg의 다양한 폴리실리콘 충진 크기에서 시뮬레이션을 통해 장비 온도 프로파일을 얻었으며, 실제값과 비교하고 분석하였다. 시뮬레이션 온도 프로파일과 실제 온도프로파일이 잘 일치하였으며, 이로써 충진 사이즈가 증가할 경우, 실제온도 프로파일 최적화를 위해 시뮬레이션을 사용할 수 있게 되었다.

Data Qualification of Optical Emission Spectroscopy Spectra in Resist/Nitride/Oxide Etch: Coupon vs. Whole Wafer Etching

  • Kang, Dong-Hyun;Pak, Soo-Kyung;Park, George O.;Hong, Sang-Jeen
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.433-433
    • /
    • 2012
  • As the requirement in patterning geometry continuously shrinks down, the termination of etch process at the exact time became crucial for the success in nano patterning technology. By virtue of real-time optical emission spectroscopy (OES), etch end point detection (EPD) technique continuously develops; however, it also faced with difficulty in low open ratio etching, typically in self aligned contact (SAC) and one cylinder contact (OCS), because of very small amount of optical emission from by-product gas species in the bulk plasma glow discharge. In developing etching process, one may observe that coupon test is being performed. It consumes costs and time for preparing the patterned sample wafers every test in priority, so the coupon wafer test instead of the whole patterned wafer is beneficial for testing and developing etch process condition. We also can observe that etch open area is varied with the number of coupons on a dummy wafer. However, this can be a misleading in OES study. If the coupon wafer test are monitored using OES, we can conjecture the endpoint by experienced method, but considering by data, the materials for residual area by being etched open area are needed to consider. In this research, we compare and analysis the OES data for coupon wafer test results for monitoring about the conditions that the areas except the patterns on the coupon wafers for real-time process monitoring. In this research, we compared two cases, first one is etching the coupon wafers attached on the carrier wafer that is covered by the photoresist, and other case is etching the coupon wafers on the chuck. For comparing the emission intensity, we chose the four chemical species (SiF2, N2, CO, CN), and for comparing the etched profile, measured by scanning electron microscope (SEM). In addition, we adopted the Dynamic Time Warping (DTW) algorithm for analyzing the chose OES data patterns, and analysis the covariance and coefficient for statistical method. After the result, coupon wafers are over-etched for without carrier wafer groups, while with carrier wafer groups are under-etched. And the CN emission intensity has significant difference compare with OES raw data. Based on these results, it necessary to reasonable analysis of the OES data to adopt the pre-data processing and algorithms, and the result will influence the reliability for relation of coupon wafer test and whole wafer test.

  • PDF

텅스텐 램프를 이용한 실리콘 재결정시의 SOI 다층구조에 대한 열적모델 (A Thermal Model for Silicon-on-Insulator Multilayer Structure in Silicon Recrystallization Using Tungsten Lamp)

  • 경종민
    • 대한전자공학회논문지
    • /
    • 제21권5호
    • /
    • pp.90-99
    • /
    • 1984
  • 양면에서 텅스텐 램프를 조사하는 실리콘 재결정시의 SOI(silicon-on-insulator) 다층구조에 대한 1차원적 온도 및 열원(열원)의 분포를 SOR(successive over-relaxation)방법을 이용하여 정상상태의 열방정식의 해로부터 구하였다. 열원의 분포는 광원의 스펙트럼, SOI sample 내부 계면에서의 다중반사, 광흡수 계수의 온도, 주파수 의존성 등을 고려하여 구하였으며, 열 방정식의 경계조건이 되는 wafer의 전면과 후면의 온도는 혹체복사 조건으로부터 구하였다. 내부계면에서는 전도열속(conduction heat flux)과 복사열속(radiation heat flux)에 의한 연속조건을 만족하도록 하였다. 본 문제에서의 온도분포와 열원의 분포는 상호간에 큰 영향을 주게 되므로, 두가지 변수가 일치되는 값을 보일 때까지 iteration을 계속하였다. Pyrometer을 이용하여 측정한 wafer 전면의 온도는 약1200°K이었고 이때의 simulation 결과는 1120°K 정도로 나타났다.

  • PDF

CMP 패드 두께 프로파일 측정 장치 및 방법에 관한 연구 (A Study on CMP Pad Thickness Profile Measuring Device and Method)

  • 이태경;김도연;강필식
    • 한국산업융합학회 논문집
    • /
    • 제23권6_2호
    • /
    • pp.1051-1058
    • /
    • 2020
  • The chemical mechanical planarization (CMP) is a process of physically and chemically polishing the semiconductor substrate. The planarization quality of a substrate can be evaluated by the within wafer non-uniformity (WIWNU). In order to improve WIWNU, it is important to manage the pad profile. In this study, a device capable of non-contact measurement of the pad thickness profile was developed. From the measured pad profile, the profile of the pad surface and the groove was extracted using the envelope function, and the pad thickness profile was derived using the difference between each profile. Thickness profiles of various CMP pads were measured using the developed PMS and envelope function. In the case of IC series pads, regardless of the pad wear amount, the envelopes closely follow the pad surface and grooves, making it easy to calculate the pad thickness profile. In the case of the H80 series pad, the pad thickness profile was easy to derive because the pad with a small wear amount did not reveal deep pores on the pad surface. However, the pad with a large wear amount make errors in the lower envelope profile, because there are pores deeper than the grooves. By removing these deep pores through filtering, the pad flatness could be clearly confirmed. Through the developed PMS and the pad thickness profile calculation method using the envelope function, the pad life, the amount of wear and the pad flatness can be easily derived and used for various pad analysis.

Si V-groove를 이용한 광섬유와 Photodiode결합에서의 Beam Profile과 결합효율에 대한 이론적 연구 (Theoretical Study of the Beam Profile and Coupling Efficiency for Fiber-Photodiode Coupling using Si V-grooves)

  • 금동인;민성욱;이병호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1265-1267
    • /
    • 1995
  • In the fiber-photodiode(PD) coupling module using v-groove, the paraxial approximation is no longer valid because the beam enters obliquely the PD substrate with the angle of $20^{\circ}$ after being reflected from the $55^{\circ}$ mirror formed by anisotropically etching of the (100) silicon wafer. In this paper, we study the beam profile incident on the PD active area and fiber-PD coupling efficiency for this case.

  • PDF