• Title/Summary/Keyword: Volumetric Ratio

Search Result 385, Processing Time 0.04 seconds

Pattern Analysis of Left Ventricular Remodeling Using Cardiac Computed Tomography in Children with Congenital Heart Disease: Preliminary Results

  • Hyun Woo Goo;Sang-Hyub Park
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.717-725
    • /
    • 2020
  • Objective: To assess left ventricular remodeling patterns using cardiac computed tomography (CT) in children with congenital heart disease and correlate these patterns with their clinical course. Materials and Methods: Left ventricular volume and myocardial mass were quantified in 17 children with congenital heart disease who underwent initial and follow-up end-systolic cardiac CT studies with a mean follow-up duration of 8.4 ± 9.7 months. Based on changes in the indexed left ventricular myocardial mass (LVMi) and left ventricular mass-volume ratio (LVMVR), left ventricular remodeling between the two serial cardiac CT examinations was categorized into one of four patterns: pattern 1, increased LVMi and increased LVMVR; pattern 2, decreased LVMi and decreased LVMVR; pattern 3, increased LVMi and decreased LVMVR; and pattern 4, decreased LVMi and increased LVMVR. Left ventricular remodeling patterns were correlated with unfavorable clinical courses. Results: Baseline LVMi and LVMVR were 65.1 ± 37.9 g/m2 and 4.0 ± 3.2 g/mL, respectively. LVMi increased in 10 patients and decreased in seven patients. LVMVR increased in seven patients and decreased in 10 patients. Pattern 1 was observed in seven patients, pattern 2 in seven, and pattern 3 in three patients. Unfavorable events were observed in 29% (2/7) of patients with pattern 1 and 67% (2/3) of patients with pattern 3, but no such events occurred in pattern 2 during the follow-up period (4.4 ± 2.7 years). Conclusion: Left ventricular remodeling patterns can be characterized using cardiac CT in children with congenital heart disease and may be used to predict their clinical course.

Preliminary Evaluation of Clearance Level of Uranium in Metal Waste Using the RESRAD-RECYCLE Code (RESRAD-RECYCLE 전산코드를 활용한 금속폐기물 내 우라늄 자체처분 허용농도 예비 평가)

  • SunWoo Lee;JungHwan Hong;JungSuk Park;KwangPyo Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.457-469
    • /
    • 2023
  • The clearance level by nuclide is announced by the Nuclear Safety and Security Commission. However, the clearance level of uranium existing in nature has not been announced, and research is needed. Therefore, the purpose of this study was to evaluate the clearance level of uranium nuclides appropriate to domestic conditions preliminary. For this purpose, this study selected major processes for recycling metal wastes and analyzed the exposure scenarios and major input factors by investigating the characteristics of each process. Then, the radiation dose to the general public and workers was evaluated according to the selected scenarios. Finally, the results of the radiation dose per unit radioactivity for each scenario were analyzed to derive the clearance level of uranium in metal waste. The results of the radiation dose assessment for both the general public and workers per unit radioactivity of uranium isotopes were shown to meet the allowable dose (individual dose of 10 µSv y-1 and collective dose of 1 Man-Sv y-1) regulated by the Nuclear Safety and Security Commission. The most conservative scenarios for volumetric and surface contamination were evaluated for the handling of the slag generated after the melting of the metal waste and the direct reuse of the contaminated metal waste into the building without further disposal. For each of these scenarios, the radioactivity concentration by uranium isotope was calculated, and the clearance level of uranium in metal waste was calculated through the radioactivity ratio by enrichment. The results of this study can be used as a basic data for defining the clearance level of uranium-contaminated radioactive waste.

Dependency of Compatibility Termination Criteria on Prehydration and Bentonite Quality for Geosynthetic Clay Liners (사전투수 및 벤토나이트 품질에 따른 GCL의 투수종결기준에 미치는 영향평가)

  • Lee Jae-Myung;Shackelford Charles D.;Choi Jae-Soon;Jung Moon-Kyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.7
    • /
    • pp.141-158
    • /
    • 2004
  • The dependency of criteria used to terminate compatibility tests on the prehydration and quality of bentonite in geosynthetic clay liners (GCLs) is evaluated based on permeation with chemical solutions containing 5, 10, 20, 50, and 100 mM calcium chloride ($CaCl_2$). The hydraulic conductivity tests are not terminated before chemical equilibrium between the effluent and the influent chemistry has been established, resulting in test durations ranging from < 1 day to > 900 days, with longer test durations associated with lower $CaCl_2$ concentrations. The evaluation includes both physical termination criteria (i.e., volumetric flow ratio and steady hydraulic conductivity based on ASTM D 5084, ${\ge}2$ pore volumes of flow, constant thickness of specimen) and chemical termination criteria requiring equilibrium between influent and effluent chemistry (viz., electrical conductivity, pH, and $Ca^{2+}\;and\;Cl^-$ concentrations). For specimens permeated with 5, 10, and 20 mM $CaCl_2$ solutions, only the criterion based on chemical equilibrium in $Ca^{2+}$ concentration correlates well with equilibrium in hydraulic conductivity, regardless of prehydration or quality of bentonite. However, all of the termination criteria, except for the volumetric flow ratio and 2 pore volumes of flow for the prehydrated specimens, correlate well with equilibrium in hydraulic conductivity regardless of prehydration or quality of bentonite when permeated with 50 and 100 mM $CaCl_2$ solutions. The results illustrate the uniqueness of the termination criterion based on solute concentration equilibrium between the effluent and the influent with respect to both prehydration and quality of bentonite in the GCLs.

Development of Vacuum Puffing Machine for Non-deep Fried Yukwa and Its Puffing Characteristics by Process Variables (비유탕 유과 제조를 위한 진공팽화기의 개발 및 공정변수에 따른 유과의 팽화특성)

  • Yu, Je-Hyeok;Ryu, Gi-Hyung
    • Food Engineering Progress
    • /
    • v.14 no.3
    • /
    • pp.193-201
    • /
    • 2010
  • The aim of this study was to analyse the quality of Yukwa puffed by using a vacuum puffing machine and compare to deep-fried Yukwa. The effect of vacuum puffing condition including heating temperature(100-${160^{\circ}C}$), preheating time(0-8 min) and vacuum puffing time(5-20 min) on physical and microstructure characteristics of the Yukwa was investigated. Vacuum puffed Yukwa at ${100^{\circ}C}$ heating temperature, 6 min preheating time and 10 min puffing time had highest value in volumetric expansion ratio(10.04) and lowest value in bulk density(0.15 g/$cm^{3}$). The breaking strength showed the lowest value of 140 g/$cm^{3}$ in vacuum puffing Yukwa at ${100^{\circ}C}$ heating temperature, 6 min preheating time and 15 min puffing time. The Yukwa puffed with the vacuum puffing machine at ${100^{\circ}C}$ heating temperature, 6 min preheating time and 15 min puffing time had the higher value of bulk density and the lower value of volumetric expansion ratio than those of deep-fried Yukwa. Increasing preheating time and vacuum puffing time caused an increase in white and an decrease in yellowness. The vacuum-puffed Yukwa exhibited smaller and uniform cell structure, while deep-fried Yukwa exhibited apparently in larger pores inside and smaller pores near the surface layer. The optimum condition of vacuum puffing machine for the production of vacuum-puffing Yukwa was ${120^{\circ}C}$ heating temperature, 4 min preheating time and 5 min puffing time.

Estimation of Volume Change and Fluid-Rock Ratio of Gouges in Quaternary Faults, the Eastern Blocks of the Ulsan Fault, Korea (울산단층 동부지역 제4기단층 비지대의 체적변화와 유체-암석비에 대한 고찰)

  • Chang Tae-Woo;Chae Yeon-Zoon;Choo Chang-Oh
    • The Journal of Engineering Geology
    • /
    • v.15 no.3
    • /
    • pp.349-363
    • /
    • 2005
  • Many Quaternary faults are recognized as thin gouge and narrow cataclastic zone juxtaposing the Bulguksa granite and Quaternary deposit bed in the eastern block of the Using Fault, Korea: Gaegok 1, Caegok 2, Singye, Madong Wonwonsa and Jinhyeon faults. This study was performed to calculate chemical change, volume change, silica loss and fluid-rock ratio taken place in gouge zones of these Quaternary faults using XRF, XRD, EPMA. The chemical compositions of fault rocks reveal that the fault gouges are depleted in $SiO_2,\;Na_2\;O,and\;K_2O$ and enriched in $Al_2O_3,\;Fe_2O_3,\;P_2O_5,\;MgO,\;MnO,\;CaO,\;and\;LOI(H_2O+CO_2)$ relative to protoliths. The fact that there is enrichment of relatively immobile elements and depletion of the more soluble elements in the fault gouges relative to protoliths can be explained by fluid-assisted volume loss of $56\%$ for Caegok 1 fault, $22\%$ for Caegok 2 fault,$34\%$, for Singye fault, $8\%$ for Madong fault, $2\%$ for the Wonwonsa fault and $53\%$ for the linhyeon fault. Madong fault and Wonwonsa fault where ratios of the volume change, silica loss and fluid-rock are low might have acted as a closed system for fluid activity, whereas Caegok 1 fault and Jinhyeon fault with high ratios in those factors be an open system. The volumetric fluid-rock ratios range $10^2\sim10^4$ for all faults, being highest in Caegok 1 fault and Jinhyeon fault whose fluid activity was most significant.

Evaluation of the Volume Changes of Grafted Bone Materials in Sinus Augmentation Procedure Using Dental Cone-beam CT (치과용 Cone-beam CT를 이용한 상악동 골 이식 후 나타난 골 이식재의 부피 변화평가)

  • Ohn, Byung-Hun;Seon, Hwa-Kyeong;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.23-36
    • /
    • 2013
  • To evaluate the 3-dimensional features of the grafted bone with maxillary sinus augmentation and to assess the relation between the degree of bone resorption and the type of bone grafting source and implant, and the operation method. A retrospective chart review of patients receiving sinus augmentation procedures for implant positioning was conducted: radiographic analysis of the volume and area of bone grafts was performed. The volumetric remodeling.measured at 6 months after implant positioning as the percentage of residual bone graft.was correlated to type of graft materials and operation methods. 53 dental implants positioned with sinus bone graft in 15 patients at Wonkwang University Sanbon Dental Hospital. Computed tomography scans,taken implant positioning after 6 months, showed greater resorption values for the group of $Puros^{(R)}$ graft alone from the group of mixed with $Puros^{(R)}$ and various bone graft (P<0.05, respectively). And resorption values according to operation methods have statistically significant difference(P<0.05). Volume change ratio of bone graft showed greater values for the group of delayed implant position from the group of simultaneously implant placement with bone graft. Retrospective data analysis shows that the method of graft with $Puros^{(R)}$ alone may occur greater resorption of graft materials than mixed graft material with $Puros^{(R)}$ and other graft materials. The group of simultaneously implant placement with bone graft also display smaller resorption ratio of bone graft than the group of delayed implant placement.

Characteristics of Combustion by Varying Different Coolant-temperature in a Hydrogen Engine for HALE UAV (고고도 무인기용 수소연료엔진의 냉각수 온도변화에 따른 연소 특성)

  • Yi, Ui-Hyung;Jang, Hyeong-Jun;Park, Cheol-Woong;Kim, Yong-Rae;Choi, Young
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.2
    • /
    • pp.59-66
    • /
    • 2018
  • Using hydrogen fuel is expected to be suitable as a reciprocating internal combustion engine with heightened interest in HALE(High Altitude Long Endurance) UAV(Unmanned Aerial Vehicle). Hydrogen is hightest energy density per mass so it can continue to charge for long periods of time and have positive part of the environmental effects. However, it is estimated that there is less research on hydrogen fuel engine currently applied, and many studies need to be done. Depending on the operation, there are factors that result in supercooling due to reduced radiation or reduce cooling performance due to low air density. Therefore, the experiment was to change the temperature of the cooling water and investigate the effect on engine combustions. The limitation of the stable operation range due to backfire is dominated by the excess air ratio rather than the effect of the cooling water temperature change. When the cooling water temperature increases, the volumetric efficiency decreases and the torque decreases. As the cooling water temperature decreases, the heat loss was increased and consequently the thermal efficiency was decreased.

Poly(phenanthrenequinone)-Poly(acrylic acid) Composite as a Conductive Polymer Binder for Submicrometer-Sized Silicon Negative Electrodes (서브마이크로미터 크기의 실리콘 음극용 폴리페난트렌퀴논-폴리아크릴산 전도성 고분자 복합 바인더)

  • Kim, Sang-Mo;Lee, Byeongil;Lee, Jae Gil;Lee, Jeong Beom;Ryu, Ji Heon;Kim, Hyung-Tae;Kim, Young Gyu;Oh, Seung M.
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.3
    • /
    • pp.87-94
    • /
    • 2016
  • In order to improve performances of submicrometer-sized Si negative electrode which shows larger volumetric change than nano-sized Si, composite binders are introduced by blending between poly(phenanthrenequinone) (PPQ) conductive polymer binder and poly(acrylic acid) (PAA) having good adhesion strength due to its carboxyl functional group. Blending between PPQ and PAA shows an effect that the adhesion strength of the Si electrode with the composite conductive binder is greatly improved after blending and this makes its better stable cycle performance. Blending ratios between PPQ and PAA in this work are 2:1, 1:1, 1:2 (by weight) and the best capacity retention at 50th cycle is observed in the electrode with the blending ratio 2:1 (named QA21). This is because that PPQ plays a role of conductive carbon among the Si particles or between Si particles and Cu current collector and PAA binds effectively the particles and the current collector. According to this synergetic effect, the internal resistance of the Si electrode with the blending ratio 2:1 is the smallest value. In addition, the Si electrode with PPQ-PAA composite binder shows the better stable cycle performance than the electrode with conventional super-P conductive carbon (20 wt.%).

Evaluation of DQA for Tomotherapy using 3D Volumetric Phantom (3차원 체적팬텀을 이용한 토모치료의 Delivery Quality Assurance 평가)

  • Lee, Sang-Uk;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.607-614
    • /
    • 2016
  • The study investigates the necessity of 3 dimensional dose distribution evaluation instead of point dose and 2 dimensional dose distribution evaluation. Treatment plans were generated on the RANDO phantom to measure the precise dose distribution of the treatment site 0.5, 1, 1.5, 2, 2.5, 3 cm with the prescribed dose; 1,200 cGy, 5 fractions. Gamma analysis (3%/3 mm, 2%/2 mm) of dose distribution was evaluated with gafchromic EBT2 film and ArcCHECK phantom. The average error of absolute dose was measured at $0.76{\pm}0.59%$ and $1.37{\pm}0.76%$ in cheese phantom and ArcCHECK phantom respectively. The average passing ratio for 3%/3 mm were $97.72{\pm}0.02%$ and $99.26{\pm}0.01%$ in gafchromic EBT2 film and ArcCHECK phantom respectively. The average passing ratio for 2%/2 mm were $94.21{\pm}0.02%$ and $93.02{\pm}0.01%$ in gafchromic EBT2 film and ArcCHECK phantom respectively. There was a more accurate dose distribution of 3D volume phantom than cheese phantom in patients DQA using tomotherapy. Therefor it should be evaluated simultaneously 3 dimensional dose evaluation on target and peripheral area in rotational radiotherapy such as tomotherapy.

Studies on the Frost Heave Revelation and Deformation Behaviour due to Thawing of Weathered Granite Soils (화강암 풍화토의 동상 발현 및 융해에 따른 변형 거동에 관한 연구)

  • 류능환;최중대;류영선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.3_4
    • /
    • pp.61-71
    • /
    • 1995
  • Natural ground is a composite consisted of the three phases of water, air and soil paircies. Among the three components, water as a material is weU understood but soil particles are not in foundation engineering. Especially, weathered granite soil generally shows a large volumetric expansion when they freeze. And, the stability and durability of the soil have shown decreased with repetitive freezing and thawing processes. These unique charcteristics may cause various construction and management problems if the soil is used as a construction material and foundation layers. This project was initiated to investigate the soil's physical and engineering characteristics resulting from freezing and freezing-thawing processes. Research results may be used as a basic data in solving various problems related to the soil's unique characteristics. The following conclusions were obtained: The degree of decomposition of weathered granite soil in Kangwon-do was very different between the West and East sides of the divide of the Dae-Kwan Ryung. Soil particles distributed wide from very coarse to fine particles. Consistency could be predicted with a function of P200 as LL=0.8 P200+20. Permeability ranged from 10-2 to 10-4cm/sec, moisture content from 15 to 20% and maximum dry density from 1.55 to 1.73 g /cmΥ$^3$ By compaction, soil particles easily crushed, D50 of soil particles decreased and specific surface significantly increased. Shear characteristics varied wide depending on the disturbance of soil. Strain characteristics influenced the soil's dynamic behviour. Elastic failure mode was observed if strain was less than 1O-4/s and plastic failure mode was observed if strain was more than 10-2/s. The elastic wave velocity in the soil rapidly increased if dry density became larger than 1.5 g /cm$^3$ and these values were Vp=250, Vg= 150, respectively. Frost heave ratio was the highest around 0 $^{\circ}C$ and the maximum frost heave pressure was observed when deformation ratio was less than 10% which was the stability state of soil freezing. The state had no relation with frost depth. Over freezing process was observed when drainage or suction freezing process was undergone. Drainage freezing process was observed if freezing velocity was high under confined pressure and suction frost process was occurred if the velocity was low under the same confined process.

  • PDF