• 제목/요약/키워드: Voltmeter

검색결과 30건 처리시간 0.027초

SURFACE POTENTIAL DISTRIBUTION ON POLYMER INSULATORS

  • Kitani, Isamu
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제11권11호
    • /
    • pp.17-21
    • /
    • 1998
  • The surface potential distribution on insulating polymers was measured by scanning of the probe of an electrostatic voltmeter. The measurements were done for two measured by scanning of the probe of an electrostatis voltmeter. The measurements were done for two cases. In the first case, it was measured on the free surface of insulating films which had been inserted between plane electodes after the removal of the upper brass disk electrode. In the second case, we measured the charging region between a circular and its opposing concentric ring electrodes after the removal of dc ramp voltage in air and nitrogen gas.

  • PDF

압전 특성을 이용한 구조물 부재의 응력측정 (Stress Measurement of Structural Member Using Piezoelectric Property)

  • 임은상;김태훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권2호
    • /
    • pp.103-108
    • /
    • 2007
  • 본 연구에서는 압전 특성과 표면전위계를 이용한 응력측정 방법을 제안하였다. 다시 말하면 이 응력측정방법은 압전소자에서 발생한 전위를 표면전위계로 측정하게 하는 방법으로서, 이 표면전위는 구조물 부재의 변형률에 비례한다는 특성을 이용하여, 구조물 부재의 각 위치에서의 발생하는 응력을 변형률로부터 계산할 수 있게 된다. 또한, 구조물 부재의 응력분포를 보다 간편하게 구하기 위해서 비접촉 측정법을 이용한 응력분포 측정 Tape를 제작하였다. 특히, 이 Tape는 균열이나 홈과 같이 이상응력 발생 가능한 위치에서의 ${\sigma}_x$, ${\sigma}_y$, ${\tau}_{xy}$의 응력을 측정 뿐만 아니라 국부 응력해석에 활용되었고 그 적용성을 검토하기 위해서 홈이 있는 실험편에 대해서 반복하중 시험결과와 FEM 해석의 결과와 비교 분석하였다.

IEC국제규격을 보급하기 위한 RRR측정장치 제작 (Fabrication of RRR Measuring System for Disseminating IEC International Standard)

  • 이규원;김규태
    • Progress in Superconductivity
    • /
    • 제4권1호
    • /
    • pp.80-85
    • /
    • 2002
  • In order to disseminate the IEC international standard of RRR measurement of Cu/Nb/-Ti composite superconductors, a measuring system was developed at KRISS. The system consisted of helium reservoir, base plate, thermometer, voltmeter and current source. The helium reservoir and base plate provided a stable temperature of a range from 4.2 K to 300 K and the voltmeter measured several order of $mutextrm{V}$ on specimen for obtaining RRR of the Cu/Nb-Ti composite superconductor. Three specimens of the Cu/Nb-Ti composite superconductors were measured using this system for characterizing their RRR. The resistance-temperature curves ortho specimens showed 10/sup -6/ to 10/sup -5/ Ohms near transition temperature and 10/sup -4/ to 10/sup -3/ Ohms at 293 K. The RRR values of the specimens were 145, 71 and 140, respectively.

  • PDF

계수형 전압계를 위한 A/D 변환기 (A/D Converter for Digital Voltmeter)

  • 노홍조;강정수;이권하
    • 대한전자공학회논문지
    • /
    • 제8권5호
    • /
    • pp.1-9
    • /
    • 1971
  • 양산화를 전제로한 계수형계측기로서 4자리표시, 정도 ±0.1% 진치 ±1 digit 이내, 입력 impedance 1000MΩ 이상(1.500V 범위), 측정범위 1mV∼1,000V 4단절환, 자동영점교정으로 저항 및 직류전류 측정기능도 갖춘 Digital Voltmeter를 목표로 이에 적합한 A/D 변환기를 추구하였다. 이 결과 A/D 변환기에서 일어나는 적분 slope의 직선성에 미치는 요인을 해석하여 매우 간단한 회로구성으로도 효과적인 성능을 보장 할 수 있음을 확인하였다.

  • PDF

표준준기에 의한 일사계 교정 (Thermopile Radiometer Calibration Using Reference Instrument)

  • 조덕기;윤창열;김광득;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.199.2-199.2
    • /
    • 2010
  • The main purpose of the calibration procedure is to perform a one to one comparison of the reference pyranometer and the test pyranometer. In order to achieve this, both pyranometers need to be exposed to exactly the same irradiance, under the same circumstances. There are a number of error sources that could result in a wrong measurement. Most importantly Lamp instability, pyranometer offsets, thermal offsets of junctions, voltmeter offset, voltmeter instability, reference pyranometer instability, tilting of the pyranometers and differences in sensor height. Another sun-disc calibration procedure compares the computed vertical component of the direct irradiance as measured by a pyranometer with that measured by the pyranometer to be calibrated. Readings are taken with the levelled pyranometer on a clear day. Firstly the global irradiance and then the diffuse component are measured. Simultaneously measurement of direct irradiance is made with the pyrheliometer. The ways of performing the calibration and the subsequent calculation have been chosen such that the effect all these error sources has been eliminated as much as possible.

  • PDF

Development of Prototype Multi-channel Digital EIT System with Radially Symmetric Architecture

  • Oh, Tong-In;Baek, Sang-Min;Lee, Jae-Sang;Woo, Eung-Je;Park, Chun-Jae
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권4호
    • /
    • pp.215-221
    • /
    • 2005
  • We describe the development of a prototype multi-channel electrical impedance tomography (EIT) system. The EIT system can be equipped with either a single-ended current source or a balanced current source. Each current source can inject current between any chosen pair of electrodes. In order to reduce the data acquisition time, we implemented multiple digital voltmeters simultaneously acquiring and demodulating voltage signals. Each voltmeter measures a differential voltage between a fixed pair of adjacent electrodes. All voltmeters are configured in a radially symmetric architecture to optimize the routing of wires and minimize cross-talks. To maximize the signal-to-noise ratio, we implemented techniques such as digital waveform generation, Howland current pump circuit with a generalized impedance converter, digital phase-sensitive demodulation, tri-axial cables with both grounded and driven shields, and others. The performance of the EIT system was evaluated in terms of common-mode rejection ratio, signal-to-noise ratio, and reciprocity error. Future design of a more innovative EIT system including battery operation, miniaturization, and wireless techniques is suggested.

열전형 전류 변환기의 교류-직류 전류 변환차이 자동측정시스템 개발 (Development of an automatic measurement system for the AC-DC current transfer difference of the thermal current converter)

  • 권성원;정재갑;김문석;김규태;류제천
    • 센서학회지
    • /
    • 제14권5호
    • /
    • pp.350-356
    • /
    • 2005
  • We have developed a dual-channel type automatic measurement system to evaluate AC-DC current transfer difference of the thermal current converter(TCC) which is primary standard of AC current. The output drift effect of the TCC is minimized by measuring simultaneously the output voltages of two TCCs using voltmeter. Furthermore, the offset voltage of the voltmeter is cancelled nearly out by taking the average values of two outputs of TCCs measured with the forward-reverse directions using dual channel scanner. The uncertainties of the automatic system were 7 to $86{\mu}A/A$ for 3 mA to 10 A at 40 Hz to 20 kHz, which were evaluated by the comparisons between adjacent range of TCCs and inter-comparison with national measurement institute of Germany(PTB). The capability for ac-dc transfer difference measurement was improved by one order compared with that for the manual ac-dc measurement system.

30~1000MHz 주파수 범위에서의 전자기장의 세기 표준 (Field Strength Standards in 30~ 1000MHz Frequency Range)

  • 김정환;강찬구
    • 한국통신학회논문지
    • /
    • 제18권12호
    • /
    • pp.1893-1901
    • /
    • 1993
  • 본 논문에서는30~1000MHz 주파수 범위에서 표준 안테나 방법을 사용한 전자기장의 세기 표종에 대하여 기술하고 있다. 관련된 안테나 소자와 밸런을 제작하였으며 또한 안테나 볼트미터의 특성에 대하여도 살펴보았다. 본 방법을 이용한 전자기장 세기의 불확도는 5~15%로 분석되었다.

  • PDF

벡터 전압 수신기를 이용한 2-포트 산란 계수 분석 시스템 (Two-Port Vector Network Analysis System with a Vector Signal Channel)

  • 이동준
    • 한국전자파학회논문지
    • /
    • 제24권5호
    • /
    • pp.541-548
    • /
    • 2013
  • 본 논문에서는 상용 벡터 회로망 분석기를 사용하지 않고도, 신호 발생기, 벡터 전압 수신기, 방향성 결합기, 주파수 혼합기 등의 기본적인 초고주파 장비/소자를 활용하여 평가하고자 하는 초고주자 소자의 2-포트 산란 계수를 측정할 수 있는 시스템을 제안한다. 벡터 회로망 분석기를 대용할 수 있는 산란 계수 측정 시스템의 해석적 모델과 제작방법을 제시하고, 이를 1-포트와 2-포트 소자에 대하여 각각 적용한 산란 계수를 측정하여 구현된 시스템을 평가하였다. 평가 주파수 대역에 따라 비교적 낮은 대역에서는 단일 신호 발생기와 벡터 전압 수신기를 사용한 직접 수신법을, 높은 대역에서는 추가의 신호원과 주파수 혼합기를 사용하여 신호를 하향 복조하는 헤테로다인 방식을 사용하여 산란 계수를 결정짓는 벡터 전압을 수신하였다. 이들 각각의 수신 방법으로 UHF와 X 대역 초고주파 소자의 2-포트 산란 계수를 평가하였고, 그 유효성을 상용 벡터 회로망 분석기로 검증하였다.

컴퓨터 기반 과학 수행평가 문항 개발 : 전류계와 전압계 회로 연결 실험 (The Development of Science Item on the Computer-Based Performance Assessment: A Experiment on Constructing Circuits with an Ammeter and a Voltmeter)

  • 최혁준
    • 과학교육연구지
    • /
    • 제37권2호
    • /
    • pp.348-358
    • /
    • 2013
  • 과학교육에서 컴퓨터는 교수 학습 뿐 아니라 평가의 목적으로도 활용되고 있다. 죽, 컴퓨터의 장점을 살린 컴퓨터 기반 평가가 실시되고 있다. 그러나 이와 같은 평가는 주로 과정 중심이 아닌 결과 중심의 평가이며, 피험자의 수만큼 컴퓨터가 있어야 하므로 학교의 정규 시험으로 활용하기 곤란하다. 그러나 수행평가의 경우 일반적으로 평가 과제가 미리 공개되므로 학급별 또는 학생별로 평가 시간이 다르게 평가를 실시하는 것이 가능하다. 따라서 본 연구에서는 실제 실험기구를 사용한 실험평가를 대체할 수 있는 컴퓨터 기반 수행평가 문항을 개발하였다. 이를 위해 먼저 물리 교사를 대상으로 과학교육에 있어 이러한 기능에 대한 평가의 필요성 및 어려운 점 등에 대한 설문조사를 실시하였고, 이를 반영하여 전류계와 전압계를 포함한 회로를 구성을 하는 평가 문항을 개발하였다. 개발된 컴퓨터 기반 문항은 실제의 실험기구를 사용하여 진행되는 평가와 유사하게 구성하였으며 평가 과정에서 학생들의 수행에 따라 적절한 피드백을 제공하고, 수행 결과를 자동적으로 채점할 수 있도록 하였다. 이를 위해 컴퓨터가 학생들의 수행 결과의 정확성을 판단할 수 있는 알고리즘을 개발하였다.

  • PDF