• Title/Summary/Keyword: Voltmeter

Search Result 30, Processing Time 0.023 seconds

SURFACE POTENTIAL DISTRIBUTION ON POLYMER INSULATORS

  • Kitani, Isamu
    • Electrical & Electronic Materials
    • /
    • v.11 no.11
    • /
    • pp.17-21
    • /
    • 1998
  • The surface potential distribution on insulating polymers was measured by scanning of the probe of an electrostatic voltmeter. The measurements were done for two measured by scanning of the probe of an electrostatis voltmeter. The measurements were done for two cases. In the first case, it was measured on the free surface of insulating films which had been inserted between plane electodes after the removal of the upper brass disk electrode. In the second case, we measured the charging region between a circular and its opposing concentric ring electrodes after the removal of dc ramp voltage in air and nitrogen gas.

  • PDF

Stress Measurement of Structural Member Using Piezoelectric Property (압전 특성을 이용한 구조물 부재의 응력측정)

  • Im, Eun Sang;Kim, Tea Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.103-108
    • /
    • 2007
  • A stress measurement method of structural member using piezoelectric property and electrostatic voltmeter is presented. The electric potentials of the surface of the piezoelectric element, which are proportional to the strain ${\varepsilon}$ on the structural member, are measured by an electrostatic voltmeter during load cycling. The stress ${\sigma}$ is calculated by this strain ${\varepsilon}$. Moreover, a stress distribution measurement tape which can be used for the stress distribution measurement along a specified line on the surface of structural member is developed, and the surface potential was measured by an electric static voltmeter of non-contact type. The applicability of the stress distribution measurement tape is examined through experiments using a notched specimen under cyclic loading. The measured distributions of x, y and xy are compared with those calculated by FEM analysis.

Fabrication of RRR Measuring System for Disseminating IEC International Standard (IEC국제규격을 보급하기 위한 RRR측정장치 제작)

  • Kyu Won Lee;Kyu Tae Kim
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.80-85
    • /
    • 2002
  • In order to disseminate the IEC international standard of RRR measurement of Cu/Nb/-Ti composite superconductors, a measuring system was developed at KRISS. The system consisted of helium reservoir, base plate, thermometer, voltmeter and current source. The helium reservoir and base plate provided a stable temperature of a range from 4.2 K to 300 K and the voltmeter measured several order of $mutextrm{V}$ on specimen for obtaining RRR of the Cu/Nb-Ti composite superconductor. Three specimens of the Cu/Nb-Ti composite superconductors were measured using this system for characterizing their RRR. The resistance-temperature curves ortho specimens showed 10/sup -6/ to 10/sup -5/ Ohms near transition temperature and 10/sup -4/ to 10/sup -3/ Ohms at 293 K. The RRR values of the specimens were 145, 71 and 140, respectively.

  • PDF

A/D Converter for Digital Voltmeter (계수형 전압계를 위한 A/D 변환기)

  • No, Hong-Jo;Gang, Jeong-Su;Lee, Gwon-Ha
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.5
    • /
    • pp.1-9
    • /
    • 1971
  • An analog to digital converter Ivhich is applicable to mass production of digital multimeter is developed. The solid state digital instrument has accuracy $\pm$0.1% of feading $\pm$1 digit over 1 mV to 1000 volts with high input impedance and automatic function. All possibility to affect the distortion of A/D converter is tudied. As a result, useful linearity with high temperature stability of integrating waveforms is achieved by the very simplified circuit configuration to assure the proposed accuracy under various ambient condition.

  • PDF

Thermopile Radiometer Calibration Using Reference Instrument (표준준기에 의한 일사계 교정)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.199.2-199.2
    • /
    • 2010
  • The main purpose of the calibration procedure is to perform a one to one comparison of the reference pyranometer and the test pyranometer. In order to achieve this, both pyranometers need to be exposed to exactly the same irradiance, under the same circumstances. There are a number of error sources that could result in a wrong measurement. Most importantly Lamp instability, pyranometer offsets, thermal offsets of junctions, voltmeter offset, voltmeter instability, reference pyranometer instability, tilting of the pyranometers and differences in sensor height. Another sun-disc calibration procedure compares the computed vertical component of the direct irradiance as measured by a pyranometer with that measured by the pyranometer to be calibrated. Readings are taken with the levelled pyranometer on a clear day. Firstly the global irradiance and then the diffuse component are measured. Simultaneously measurement of direct irradiance is made with the pyrheliometer. The ways of performing the calibration and the subsequent calculation have been chosen such that the effect all these error sources has been eliminated as much as possible.

  • PDF

Development of Prototype Multi-channel Digital EIT System with Radially Symmetric Architecture

  • Oh, Tong-In;Baek, Sang-Min;Lee, Jae-Sang;Woo, Eung-Je;Park, Chun-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.4
    • /
    • pp.215-221
    • /
    • 2005
  • We describe the development of a prototype multi-channel electrical impedance tomography (EIT) system. The EIT system can be equipped with either a single-ended current source or a balanced current source. Each current source can inject current between any chosen pair of electrodes. In order to reduce the data acquisition time, we implemented multiple digital voltmeters simultaneously acquiring and demodulating voltage signals. Each voltmeter measures a differential voltage between a fixed pair of adjacent electrodes. All voltmeters are configured in a radially symmetric architecture to optimize the routing of wires and minimize cross-talks. To maximize the signal-to-noise ratio, we implemented techniques such as digital waveform generation, Howland current pump circuit with a generalized impedance converter, digital phase-sensitive demodulation, tri-axial cables with both grounded and driven shields, and others. The performance of the EIT system was evaluated in terms of common-mode rejection ratio, signal-to-noise ratio, and reciprocity error. Future design of a more innovative EIT system including battery operation, miniaturization, and wireless techniques is suggested.

Development of an automatic measurement system for the AC-DC current transfer difference of the thermal current converter (열전형 전류 변환기의 교류-직류 전류 변환차이 자동측정시스템 개발)

  • Kwon, Sung-Won;Jung, Jae-Kap;Kim, Mun-Seog;Kim, Kye-Tae;Ryu, Je-Cheon
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.350-356
    • /
    • 2005
  • We have developed a dual-channel type automatic measurement system to evaluate AC-DC current transfer difference of the thermal current converter(TCC) which is primary standard of AC current. The output drift effect of the TCC is minimized by measuring simultaneously the output voltages of two TCCs using voltmeter. Furthermore, the offset voltage of the voltmeter is cancelled nearly out by taking the average values of two outputs of TCCs measured with the forward-reverse directions using dual channel scanner. The uncertainties of the automatic system were 7 to $86{\mu}A/A$ for 3 mA to 10 A at 40 Hz to 20 kHz, which were evaluated by the comparisons between adjacent range of TCCs and inter-comparison with national measurement institute of Germany(PTB). The capability for ac-dc transfer difference measurement was improved by one order compared with that for the manual ac-dc measurement system.

Field Strength Standards in 30~ 1000MHz Frequency Range (30~1000MHz 주파수 범위에서의 전자기장의 세기 표준)

  • 김정환;강찬구
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.12
    • /
    • pp.1893-1901
    • /
    • 1993
  • This paper presents the field strength standard established using a standard antenna method in the frequency range of 30~1000MHz at KRISS(Korea Research Institute of Standards and Science). Designs on antenna elements and a balun, and the characteristics of an antenna voltmeter are described. The uncertainties in generation the standard fields are analzed and estimated to be 5~14%.

  • PDF

Two-Port Vector Network Analysis System with a Vector Signal Channel (벡터 전압 수신기를 이용한 2-포트 산란 계수 분석 시스템)

  • Lee, Dong-Joon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.541-548
    • /
    • 2013
  • This paper presents a vector network analysis system for 2-port scattering parameters of microwave devices using some basic microwave instruments/devices such as signal generators, vector voltmeter, directional couplers and frequency mixers. The analytical model and implementation method for scattering parameter measurements - which can replace the vector network analyzers - are presented. The performance of the implemented system is evaluated through 1- and 2-port scattering parameter measurements, respectively. The vector volt signals which determine the scattering parameters are detected in two distinct methods depending on the frequency band of interests; a direct-detection method with a single signal generator and vector voltmeter for relatively low band and a heterodyne method to frequency down-mix associated with an additional signal source as well as frequency mixers for high band are used, respectively. Using these two methods, scattering parameters of UHF and X bands are evaluated and their performances are verified through a comercial vector network analyzer.

The Development of Science Item on the Computer-Based Performance Assessment: A Experiment on Constructing Circuits with an Ammeter and a Voltmeter (컴퓨터 기반 과학 수행평가 문항 개발 : 전류계와 전압계 회로 연결 실험)

  • Choi, Hyukjoon
    • Journal of Science Education
    • /
    • v.37 no.2
    • /
    • pp.348-358
    • /
    • 2013
  • The purpose of this study is to develop the science item on computer-based performance assessment which is able to replace the assessment with actual experimental apparatus. The survey on the necessities and the difficulties of the assessment with actual experimental apparatus was conducted with 57 physics teachers. By reflecting the results of the survey, the computer-based assessment items which are related with constructing circuits with an ammeter and a voltmeter were developed. The developed computer-based assessment items were organized in similarity to assessment conducted with actual experimental apparatus, proper feedback was provided by students' performance in the process of assessment so as to grading performance results automatically. To achieve them, the algorithm was developed so that computer can judge the accuracy of students' performance results.

  • PDF