• 제목/요약/키워드: Voltage variation

검색결과 1,807건 처리시간 0.029초

배전계통의 전압조정기 운영방법에 따른 분산형전원 최대 도입 용량 산출 (The Maximum Installable DG Capacity According to Operation Methods of Voltage Regulator in Distribution Systems)

  • 김미영
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1263-1269
    • /
    • 2009
  • Stable and sustainable power supply means maintaining a certain level of power quality and service while securing energy resource and resolving environmental issues. Distributed generation (DG) has become an essential and indispensable element from environmental and energy security perspectives. It is known that voltage violation is the most important constraint for load variation and the maximum allowable DG. In distribution system, sending voltage from distribution substation is regulated by ULTC (Under Load Tap Changer) designed to maintain a predetermined voltage level. ULTC is controlled by LDC (Line Drop Compensation) method compensating line voltage drop for a varying load, and the sending voltage of ULTC calls for LDC parameters. The consequence is that the feasible LDC parameters considering variation of load and DG output are necessary. In this paper, we design each LDC parameters determining the sending voltage that can satisfy voltage level, decrease ULTC tap movement numbers, or increase DG introduction. Moreover, the maximum installable DG capacity based on each LDC parameters is estimated.

BSO 전압변성기 온도특성에 관한 연구

  • 우형관;송준태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.232-232
    • /
    • 2009
  • In this paper, we investigated the sensitivity characteristics of $Bi_{12}BiO_{20}$ (BSO) voltage transformer (VT) by utilizing optical output measured according to the variation of ambient temperature and applied voltage. Fabricated BSO VT slightly showed the decrease of the accuracy in range of from $-20^{\circ}C$ to $50^{\circ}C$, on the other hand, the variation of the optical output result was not observed at the variation of applied voltage. We could finally confirm the temperature stability, applied voltage range, and the possibility that BSO could be applied for optical sensors in GIS system.

  • PDF

전류공유버스를 이용한 병렬 인버터 순시 제어기 설계 (Instantaneous Current Control for Parallel Inverter with a Current Share Bus)

  • 이창석;김시경
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.90-94
    • /
    • 1998
  • The parallel inverter is popularly used because of its fault-tolerance capability, high-current outputs at constant voltages and system modularity. The conventional parallel inverter usually employes active and reactive power control or frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes a novel control scheme for power equalization in parallel connected inverter. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employes a instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Futhermore, the proposed control scheme is verified through the simulation in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF

A Current Sharing Circuit for the Parallel Inverter

  • Lee, Chang-Seok;Kim, Si-Kyung
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.176-181
    • /
    • 1998
  • The parallel inverter is popularly used because of its fault-tolerance capability, high-current outputs at constant voltages and system modularity. The conventional parallel inverter usually employs active and reactive power control of frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes a novel control scheme for power equalization in parallel-connected inverter. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employees an instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Furthermore, the proposed control scheme is verified through the experiment in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF

A Study on Effective Enhancement of Load Power Factor Using the Load Power Factor Sensitivity of Generation Cost

  • Lee Byung Ha;Kim Jung-Hoon
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권3호
    • /
    • pp.252-259
    • /
    • 2005
  • Various problems such as increase of power loss and voltage instability may often occur in the case of low load power factor. The demand of reactive power increases continuously with the growth of active power and restructuring of electric power companies makes the comprehensive management of reactive power a troublesome problem, so that the systematic control of load power factor is required. In this paper, the load power factor sensitivity of generation cost is derived and it is used for effectively determining the locations of reactive power compensation devices and for enhancing the load power factor appropriately. In addition, voltage variation penalty cost is introduced and integrated costs including voltage variation penalty cost are used for determining the value of load power factor from the point of view of economic investment and voltage regulation. It is shown through application to a large-scale power system that the load power factor can be enhanced effectively using the load power factor sensitivity and the integrated cost.

Asymmetrical 반브리지 컨버터의 이차측 다이오드 전압스트레스저감을 위한 새로운 하이브리드 제어기법 (A new hybrid control scheme for reduction of secondary diode voltage stresses Based on interleaved PFC Asymmetrical Half Bridge Topology)

  • 박남주;이동윤;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1416-1418
    • /
    • 2005
  • This paper presents a new hybrid control method of asymmetrical half-bridge converter(AHBC) with low voltage stresses of the diodes and interleaved PFC(power factor correction). The proposed new control scheme can observe variation of secondary diodes voltage stresses by variation of duty ratio and then decide the control portions which are asymmetrical control and PFM(Pulse Frequency Modulation). Therefore, the proposed control scheme has many advantages such as a low rated voltage of the secondary diodes, low conduction loss according to the low voltage drop and wide zvs range by load variation. Through simulation results, the validity of the proposed control scheme is demonstrated.

  • PDF

전원 전압 왜곡과 주파수 변동 시 단상 PWM 컨버터의 전류 제어 (Current Control of a Single-phase PWM Converter under the Distorted Source Voltage and Frequency Condition)

  • 안창헌;김상훈
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.356-362
    • /
    • 2015
  • This paper presents a current control strategy in the synchronous reference frame for a single-phase PWM converter, which ensures sinusoidal input current control under the distorted source voltage and frequency condition. Given that the distorted source voltage distorts the phase angle for PWM converter control, the input current contains the same harmonics as the source voltage. Aside from the distorted voltage, the variation in source frequency reduces the performance of input current control. To achieve sinusoidal input current control under the distorted source voltage and frequency condition, this paper proposes a compensation strategy of current reference with the distortion component extracted from the phase angle and a detection strategy of frequency variation from the output of a synchronous reference frame phase-lock loop. The experimental results confirm the validity of the proposed method under the distorted source voltage and frequency condition.

LED 비상 유도등 동작을 위한 태양광발전 계통연계 전원동기 방식의 전압형 인버터 구동 특성 (Characteristic of VSI Driven by Source Synchronous Type for the Utility Interactive using a Photovoltaic Generation for the LED Luminaire Emergency Exit Sign Operation)

  • 황락훈;나용주
    • 한국항행학회논문지
    • /
    • 제22권5호
    • /
    • pp.420-428
    • /
    • 2018
  • 본 논문은 태양광 발전시스템을 승압쵸퍼와 단상 펄스폭변조 전압형인버터를 사용하여 전원차단 경우나 전압변동 및 부하변동에 의한 출력전류 변화에도 일정한 출력전압을 유지하는 무정전 전원 공급장치(UPS)를 구성하였다. 본 시스템은 전압형인버터를 교류전원과 동기 시켜서 운전하고 정상상태에서는 전원으로부터 운전하고 정상상태에서는 전원으로부터 직류 측에 연결된 축전지를 태양전지를 이용한 광기전력효과와 함께 일정전압을 충전하며, 전원의 차단, 전원의 전압변동 및 부하전류의 변화에도 일정한 전압을 유지하도록 하였다. 에너지 저장장치 (ESS; energy storage system)를 상시 운영하여 공항의 기상 변화에 따른 파장별 LED 항공 유도신호 등을 효율적으로 운용하는 시스템을 구성 하였고, 전력절감효과를 얻을 수 있는 에너지절약 전원복합형 전력변환장치로 구성되어 있다. 출력은 PWM방식에 의하여 양호한 파형이 되도록 하고 전원차단과 부하의 상태의 변화 및 전원 전압 변동에도 일정한 전압으로 출력됨을 실험을 통하여 확인 할 수 있었다.

n-채널 OLED 구동 박막 트랜지스터의 문턱전압 변동을 보상할 수 있는 OLED 화소회로 (An OLED Pixel Circuit Compensating Threshold Voltage Variation of n-channel OLED·Driving TFT)

  • 정훈주
    • 한국정보전자통신기술학회논문지
    • /
    • 제15권3호
    • /
    • pp.205-210
    • /
    • 2022
  • 본 논문은 OLED 구동 박막 트랜지스터의 문턱전압 변동에 의한 AMOLED 디스플레이의 휘도 불균일도를 개선하기 위해 n-채널 박막 트랜지스터만을 사용한 새로운 OLED 화소회로를 제안하였다. 제안한 OLED 화소회로는 6개의 n-채널 박막 트랜지스터와 2개의 커패시터로 구성하였다. 제안한 OLED 화소회로의 동작은 커패시터 초기화 구간, OLED 구동 박막 트랜지스터의 문턱전압을 감지하는 구간, 영상 데이터 전압 기입 구간 및 OLED 발광 구간으로 구성되어 있다. SmartSpice 시뮬레이션 결과, OLED·구동 박막 트랜지스터의 문턱전압이 1.5±0.3 V 변동 시 제안한 OLED 화소회로는 OLED 전류 1 nA에서 최대 전류 오차가 5.18 %이고 OLED 음극 전압이 0.1 V 상승 시 제안한 OLED 화소회로가 기존 OLED 화소회로보다 OLED·전류 변화가 매우 적었다. 그러므로, 기존 OLED 화소회로보다 제안한 화소회로가 문턱전압 변동 및 OLED 음극 전압 상승에 뛰어난 보상 특성을 가진다는 것을 확인하였다.

온도에 따른 저항 변화를 보상한 전압 측정 방법 (Compensation of Resistance Variation due to Temperature in Voltage Measurement System)

  • 민상준;김진성
    • 한국정밀공학회지
    • /
    • 제29권11호
    • /
    • pp.1174-1177
    • /
    • 2012
  • In voltage measurement by using voltage divider with series resistors, error is generated caused by the variation of resistance. In order to reduce these errors, the hardware cost tends to increase in the previous works. In the proposed method, three resistors are used for the voltage divider of which the organization is adjusted by using switches. Three voltages are measured and the ratio of resistance is calculated based on the measured voltages. Since the resistance ratio is calculated by measuring voltages and additional hardware cost is minimal, the voltage can be measured with high accuracy and low cost. Experimental results show that the mean absolute error is 12.1 mV when the input voltage ranges from 5 V to 50 V.