• Title/Summary/Keyword: Voltage source converter

Search Result 637, Processing Time 0.03 seconds

Design and implementation of 3 kW Photovoltaic Power Conditioning System using a Current based Maximum Power Point Tracking (전류형 MPPT를 이용한 3 kW 태양광 인버터 시스템 제어기 설계 및 구현)

  • Cha, Han-Ju;Lee, Sang-Hoey;Kim, Jae-Eon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1796-1801
    • /
    • 2008
  • In this paper, a new current based maximum power point tracking (CMPPT) method is proposed for a single phase photovoltaic power conditioning system and the current based MPPT modifies incremental conductance method. The current based MPPT method makes the entire control structure of the power conditioning system simple and uses an inherent current source characteristic of solar cell array. In addition, digital phase locked loop using an all pass filter is introduced to detect phase of grid voltage as well as peak voltage. Controllers about dc/dc boost converter, dc-link voltage, dc/ac inverter is designed for a coordinated operation. Furthermore, PI current control using a pseudo synchronous d-q transformation is employed for grid current control with unity power factor. 3kW prototype photovoltaic power conditioning system is built and its experimental results are given to verify the effectiveness of the proposed control schemes.

A Low-Voltage Low-Power Opamp-Less 8-bit 1-MS/s Pipelined ADC in 90-nm CMOS Technology

  • Abbasizadeh, Hamed;Rikan, Behnam Samadpoor;Lee, Dong-Soo;Hayder, Abbas Syed;Lee, Kang-Yoon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.6
    • /
    • pp.416-424
    • /
    • 2014
  • This paper presents an 8-bit pipelined analog-to-digital converter. The supply voltage applied for comparators and other sub-blocks of the ADC were 0.7V and 0.5V, respectively. This low power ADC utilizes the capacitive charge pump technique combined with a source-follower and calibration to resolve the need for the opamp. The differential charge pump technique does not require any common mode feedback circuit. The entire structure of the ADC is based on fully dynamic circuits that enable the design of a very low power ADC. The ADC was designed to operate at 1MS/s in 90nm CMOS process, where simulated results using ADS2011 show the peak SNDR and SFDR of the ADC to be 47.8 dB (7.64 ENOB) and 59 dB respectively. The ADC consumes less than 1mW for all active dynamic and digital circuitries.

Development of Electronic Ballast for Automotive HID lamp using Holt Bridge Inverter (Half Bridge 구조를 이용한 자동차 헤드라이트용 전자식 안정기 개발)

  • 조계현;박종연;박재일
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.2
    • /
    • pp.10-16
    • /
    • 2003
  • An electronic ballast for driving automotive HID lamps is presented. The circuit topology is composed of a fly back converter, a half bridge inverter, and igniter using voltage doubler. A prototype was developed and tested on a 35W lamp with a 12V input voltage. To avoiding acoustic resonance the half bridge inverter is operated at 400Hz and provided a squared-wave voltage source to the lamp. The transient and steady state characteristics of the tested HID lapm are measured and analyzed.

The Realization of a Single-Phase Parallel Active Power Filter to Eliminate Harmonics of Source Current Generated by Nonlinear Loads (비선형부하에 의해 발생한 전원 전류의 고조파를 제거하기 위한 단상 병렬형 Active Power Filter의 구현)

  • Jang, Mok-Soon;Lee, Hu-Chan;Kim, Sang-Hoon;Park, Jong-Yeon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.220-221
    • /
    • 2006
  • This paper presents a single-phase parallel active power filter with an analog control circuit to eliminate for harmonic source currents generated by nonlinear loads. The proposed system removes the harmonic source currents by injecting a compensation current that is 180' out of phase with the load harmonic current. The detection of the load harmonics is realized by a simple new structure, referred to the Notch Filter with GIC (Generalized Impedance Converter), which has higher Q than existing harmonic detecters and a simpler structure. The compensation current is obtained using the proposed harmonic detection circuit, DC-Link voltage, and output current of the full-bridge inverter controlled current mode PWM controller. The operation of the proposed system is verified experimentally.

  • PDF

Four Novel PWM Shoot-Through Control Methods for Impedance Source DC-DC Converters

  • Vinnikov, Dmitri;Roasto, Indrek;Liivik, Liisa;Blinov, Andrei
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.299-308
    • /
    • 2015
  • This study proposes four novel pulse width modulation (PWM) shoot-through control methods for impedance source (IS) galvanically isolated DC-DC converters. These methods are derived from a PWM control method with shifted shoot-through introduced by the authors in 2012. In contrast to the baseline solution, where the shoot-through states are generated by the simultaneous conduction of all transistors in the inverter bridge, our new approach is based on the shoot-through generation by one inverter leg. The idea is to increase the number of soft-switched transients and, therefore, decrease the dynamic losses of the front-end inverter. All the proposed approaches are experimentally verified through an insulated-gate bipolar transistor-based IS DC-DC converter. Conclusions are drawn in accordance with the results of the switching loss analysis.

A Capacitance Deviation-to-Time Interval Converter Based on Ramp-Integration and Its Application to a Digital Humidity Controller (램프-적분을 이용한 용량치-시간차 변환기 및 디지털 습도 조절기에의 응용)

  • Park, Ji-Mann;Chung, Won-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.12
    • /
    • pp.70-78
    • /
    • 2000
  • A novel capacitance deviation-to-time interval converter based on ramp-integration is presented. It consists of two current mirrors, two schmitt triggers, and control digital circuits by the upper and lower sides, symmetrically. Total circuit has been with discrete components. The results show that the proposed converter has a linearity error of less than 1% at the time interval(pulse width) over a capacitance deviation from 295 pF to 375 pF. A capacitance deviation of 40pF and time interval of 0.2 ms was measured for sensor capacitance of 335 pF. Therefore, the high-resolution can be known by counting the fast and stable clock pulses gated into a counter for time interval. The application of a novel capacitance deviation-to time interval converter to a digital humidity controller is also presented. The presented circuit is insensitive to the capacitance difference in disregard of voltage source or temperature deviation. Besides the accuracy, it features the small MOS device count integrable onto a small chip area. The circuit is thus particularly suitable for the on-chip interface.

  • PDF

Minimize Reactive Power Losses of Dual Active Bridge Converters using Unified Dual Phase Shift Control

  • Wen, Huiqing;Su, Bin
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.654-664
    • /
    • 2017
  • This paper proposed an unified dual-phase-shift (UDPS) control for dual active bridge (DAB) converters in order to improve efficiency for a wide output power range. Different operating modes of UDPS are characterized with respect to the reactive current distribution. The proposed UDPS has the same output power capability with conventional phase-shift (CPS) method. Furthermore, its implementation is simple since only the change of the leading phase-shift direction is required for different operating power range. The proposed UDPS control can minimize both the inductor rms current and the circulating reactive current for various voltage conversion ratios and load conditions. The optimal phase-shift pairs for two bridges of DAB converter are derived with respect to the comprehensive reactive power loss model, including the reactive components delivered from the load and back to the source. Simulation and experimental results are illustrated and explained with details. The effectiveness of the proposed method is verified in terms of reactive power losses minimization and efficiency improvement.

A CMOS Envelope Tracking Power Amplifier for LTE Mobile Applications

  • Ham, Junghyun;Jung, Haeryun;Kim, Hyungchul;Lim, Wonseob;Heo, Deukhyoun;Yang, Youngoo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.2
    • /
    • pp.235-245
    • /
    • 2014
  • This paper presents an envelope tracking power amplifier using a standard CMOS process for the 3GPP long-term evolution transmitters. An efficiency of the CMOS power amplifier for the modulated signals can be improved using a highly efficient and wideband CMOS bias modulator. The CMOS PA is based on a two-stage differential common-source structure for high gain and large voltage swing. The bias modulator is based on a hybrid buck converter which consists of a linear stage and a switching stage. The dynamic load condition according to the envelope signal level is taken into account for the bias modulator design. By applying the bias modulator to the power amplifier, an overall efficiency of 41.7 % was achieved at an output power of 24 dBm using the 16-QAM uplink LTE signal. It is 5.3 % points higher than that of the power amplifier alone at the same output power and linearity.

A Design and Characteristic Analysis of ZVS-Half Bridge type High-Frequency Resonant DC-DC Converter Using Soft-Switching Technique (소프트 스위칭 기법을 이용한 ZVS-HB형 고주파 공진 DC-DC 컨버터의 설계 및 특성해석)

  • Oh, Kyeong-Seob;Nam, Seung-Sik;Kim, Kyeong-Sik;Kim, Dong-Hee;Ro, Chae-Gyun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.4
    • /
    • pp.179-187
    • /
    • 2001
  • In recent years, the switching source devices have the advantage of small, light and high reliability with the high-frequency. But, high-frequency switching has disclosed disadvantage of result from stress and turn-on and turn-off peak losses at the switching instant. Accordingly, in this paper propose ZVS-HB type high-frequency resonant DC/DC converter using soft switching technique (Zero-Voltage-Switching, Zero-Current-Switching) with safety operating of circuit at diving on inductive zone, through the circuit design example using the capacitor $C_3,\;C_4$ with soft switching function and division characteristic of resonant Capacitor C, $C_1,\;C_2$, and, the characteristic analysis of circuit is generally described using normalized parameters. Also, this paper certified a rightfulness of characteristic analysis in comparison with a theoretical values and a experimental values obtain from experiment using MOSFET.

  • PDF

The Modeling of Hybrid Railway Vehicle Power System Using Fuel Cell and IPT System (연료전지 및 유도급전 시스템을 이용한 하이브리드 철도차량 시스템 모델링)

  • Han, K.H.;Jang, H.Y.;Kwon, S.Y.;Park, H.J.;Lee, B.Y.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1038-1039
    • /
    • 2008
  • This paper proposes a base models of Hybrid railway vehicle power system. A powered system with fuel cell is regarded as a high current and low voltage source. The design parameters of the system should be chosen by taking into account the characteristics of the fuel cell, so the costs of the power system at given operating conditions can be reduced. Currently, no integrated simulation has been approached to analyze interrelated effects. Therefore, the base models of power conversion system with a PEM fuel cell/IPT system for hybrid powered system that includes the PEM fuel cell stack, DC/DC converter are developed. Concept of bidirectional converter for super capacitor charging system is presented.

  • PDF