• Title/Summary/Keyword: Voltage modulation

Search Result 1,176, Processing Time 0.025 seconds

60 GHz Optical Carrier Generator using Quasi-Velocity-Matching Technique (Quasi-Velocity-Matching물 이용한 60 GHz 광캐리어 발생기)

  • Kim, W.K.;Yang, W.S.;Lee, H.M.;Lee, H.Y.;Jeong, W.J.;Kwon, S.W.
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.181-185
    • /
    • 2006
  • A novel 60GHz optical carrier generator with a polarization domain-inverted structure is suggested and is demonstrated. The two arms of the Mach-Zehnder optical waveguide are periodically poled for quasi-phase velocity matching between the optical wave at 1550nm and the RF wave at 30 GHz. The center frequency of band-pass modulation and the 3 dB bandwidth of the fabricated modulator were measured to be 30.3 GHz and 5.1 GHz, respectively. Sub-carriers with the frequency difference of 60GHz waeregenerated under appropriate DC biac voltage application while the carrier was suppressed to lead to the power ratio between the modulated sub-carrier and the suppressed fundamental carrier of 28 dB, which proves that double sideband- suppressed carrier(DSB-SC) operation can be realized by the suggested single device.

저압 전력선 채널 특성을 고려한 OFDM변조 전송

  • Kang Duk-Ha;Heo Yoon-Seok;Cho Ki-Hyung;Lee Dae-Young
    • The Journal of Information Technology
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 2003
  • This paper is about power line communication(PLC) over the low power voltage grid. The main advantage with power line communication is the use of an existing infrastructure. The PLC channel can be modeled as having multi-path propagation with frequency-selective fading, typical power lines exhibit signal attenuation increasing with length and frequency. OFDM(Orthogonal Frequency Division Multiplexing) is a modulation technique where multiple low data rate carriers are combined by a transmitter to form a composite high data rate transmission. To implement the multiple carrier scheme using a bank of parallel modulators would not be very efficient in analog hardware. Each carrier in an OFDM is a sinusoid with a frequency that is an integer multiple of a base or fundamental sinusoid frequency. Therefore, each carrier is a like a Fourier series component of the composite signal. In fact, it will be shown later that an OFDM signal is created in the frequency domain, and then transformed into the time domain via the Discrete Fourier Transform(DFT).

  • PDF

Fabrication of a HTS SQUID Magnetometer for Magnetocardiogram (심자도 측정용 고온초전도 SQUID magnetometer의 제작)

  • Kim, In-Seon;Lee, Sang-Kil;Kim, Jin-Mok;Kwon, Hyuk-Chan;Lee, Yong-Ho;Park, Yon-Ki;Park, Jong-Chul
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.258-264
    • /
    • 1997
  • $YBa_{2}Cu_{3}O_{7}$ single layer dc SQUID magnetometers, prepared on $1\;cm^{2}\;SrTiO_{3}$ substrates, have been fabricated and characterized. Based on the analytical description, a SQUID magnetometer design having a 8.5 mm pickup coil with 2.6 mm linewidth, and a SQUID inductance Ls = 50 pH with $3\;{\mu}m$ Josephson junctions is presented. The devices showed a maximum modulation voltage depth of $65\;{\mu}V$ and a magnetic field noise of 0.6 pT /$\sqrt{Hz}$ at 1 Hz. Clear traces of human magnetocardiogram could be obtained with the SQUID magnetometer operating at 77 K.

  • PDF

Digitally Controlled Single-inductor Multiple-output Synchronous DC-DC Boost Converter with Smooth Loop Handover Using 55 nm Process

  • Hayder, Abbas Syed;Park, Young-Jun;Kim, SangYun;Pu, Young-Gun;Yoo, Sang-Sun;Yang, Youngoo;Lee, Minjae;Hwang, Keum Choel;Lee, Kang-Yoon
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.821-834
    • /
    • 2017
  • This paper reports on a single-inductor multiple-output step-up converter with digital control. A systematic analog-to-digital-controller design is explained. The number of digital blocks in the feedback path of the proposed converter has been decreased. The simpler digital pulse-width modulation (DPWM) architecture is then utilized to reduce the power consumption. This architecture has several advantages because counters and a complex digital design are not required. An initially designed unit-delay cell is adopted recursively for the construction of coarse, intermediate, and fine delay blocks. A digital limiter is then designed to allow only useful code for the DPWM. The input voltage is 1.8 V, whereas output voltages are 2 V and 2.2 V. A co-simulation was also conducted utilizing PowerSim and Matlab/Simulink, whereby the 55 nm process was employed in the experimental results to evaluate the performance of the architecture.

Comparison of Temperature Loss from The Switching Method of Midium Voltage Multilevel Inverter (고압 멀티레벨 인버터의 스위칭 기법에 따른 온도 손실 비교)

  • Lee, Seul-A;Kang, Jin-Wook;Hong, Seok-Jin;Hyun, Seong-Wook;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.9-10
    • /
    • 2016
  • 최근 급속한 산업 발달로 인하여 기존의 수 MW급 대용량 인버터가 산업용 팬, 컴프레서, 고속 철도 시스템 등 여러 분야에 사용되면서 이와 관련된 대용량 인버터 연구가 활발히 진행 중이다. 이런 대용량 인버터는 고효율과 직병렬의 구성된 전력용반도체 소자를 동시다발적으로 제어되어야하기 때문에 멀티레벨 인버터의 구조가 가장 적합하다. Cascaded H-bridge 멀티레벨 인버터는 커패시터와 다이오드를 사용하지 않고 스위치만으로 구성하며, 필터를 따로 구성하지 않아도 정현파와 유사하게 전압을 출력할 수 있다. 이로 인해 고주파 감소 및 각 셀을 직렬로 연결하여 입력전압보다 높은 출력전압을 얻을 수 있다. 또한, 스위칭 방법에 따라 동일한 Cascaded H-bridge 멀티레벨인버터 토폴로지에서도 각 THD와 온도에 따른 손실이 달라질 수 있다. Cascaded H-bridge 멀티레벨 인버터에서 이용하는 스위칭 방식은 첫 번째로 유니폴라 방식을 기본으로 한 Phase-shift가 있다. 이는 180도 위상차를 갖는 2개의 레퍼런스 파형과 위상천이가 된 캐리어 파형의 비교로 PWM (Pulse Width Modulation) 을 수행한다. 두 번째 방식으로는 Level-shift가 있다. 이는 캐리어 파형을 IPD (In-Phase Disposition) 방식으로 수직적으로 대역폭이 연속적이게 나열하여 레퍼런스 파형과 비교하는 PWM방식이다. 본 논문에서는 Phase-shift와 Level-shift 방식에 따른 Cascaded H-bridge 인버터와 NPC (Neutral Point Clamped) 인버터를 결합한 토폴로지에서의 온도에 따른 손실을 분석하고, 시뮬레이션을 통하여 비교 분석하였다.

  • PDF

Optimization of exposure parameters and relationship between subjective and technical image quality in cone-beam computed tomography

  • Park, Ha-Na;Min, Chang-Ki;Kim, Kyoung-A;Koh, Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.139-151
    • /
    • 2019
  • Purpose: This study was performed to investigate the effect of exposure parameters on image quality obtained using a cone-beam computed tomography (CBCT) scanner and the relationship between physical factors and clinical image quality depending on the diagnostic task. Materials and Methods: CBCT images of a SedentexCT IQ phantom and a real skull phantom were obtained under different combinations of tube voltage and tube current (Alphard 3030 CBCT scanner, 78-90 kVp and 2-8 mA). The images obtained using a SedentexCT IQ phantom were analyzed technically, and the physical factors of image noise, contrast resolution, spatial resolution, and metal artifacts were measured. The images obtained using a real skull phantom were evaluated for each diagnostic task by 6 oral and maxillofacial radiologists, and each setting was classified as acceptable or unacceptable based on those evaluations. A statistical analysis of the relationships of exposure parameters and physical factors with observer scores was conducted. Results: For periapical diagnosis and implant planning, the tube current of the acceptable images was significantly higher than that of the unacceptable images. Image noise, the contrast-to-noise ratio (CNR), the line pair chart on the Z axis, and modulation transfer function (MTF) values showed statistically significant differences between the acceptable and unacceptable image groups. The cut-off values obtained using receiver operating characteristic curves for CNR and MTF 10 were useful for determining acceptability. Conclusion: Tube current had a major influence on clinical image quality. CNR and MTF 10 were useful physical factors that showed significantly associations with clinical image quality.

Characteristic Verification of Electronically Scanned Array Antenna for a Ku-band FMCW Radar (Ku-대역 FMCW 레이더용 전자식 빔 조향 배열 안테나 특성 검증)

  • Chae-Hyun Jung;Jaemin Lee;Minchul Kim;Hang-Soo Lee;Sungjun Yoo;Sunghoon Jang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.4
    • /
    • pp.65-71
    • /
    • 2023
  • In this paper, the design, fabrication and verification steps of an electronically scanned array antenna(AESA) for a photonics-based Ku-band FMCW radar system is described. The presented system consists of a transmitter and a receiver respectively, which has a same antenna in the transceiver. The designed antenna has 2×8 array configuration and operates at Ku-band. The VSWR(Voltage Standing Wave Ratio) of each 16-radiators and the coupling power between radiators is measured. Also, in order to minimize the radar system damage because of handover power from the transmitter antenna to the receiver antenna when the transmitter works, the isolation between the transmitter antenna and the receiver antenna is optimized by test. As a result, beamwidth, side lobe level and beam steering characteristic are obtained by synthesizing each radiator pattern measurement data after each beam pattern of 16-radiators is measured in the near-field chamber.

Survey of Technical Parameters for Pediatric Chest X-ray Imaging by Using Effective DQE and Dose (유효검출양자효율과 선량을 이용한 소아 흉부 X-선 영상의 기술적인 인자에 관한 조사)

  • Park, Hye-Suk;Kim, Ye-Seul;Kim, Sang-Tae;Park, Ok-Seob;Jeon, Chang-Woo;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.163-171
    • /
    • 2011
  • The purpose of this study was to investigate the effect of various technical parameters for the dose optimization in pediatric chest radiological examinations by evaluating effective dose and effective detective quantum efficiency (eDQE) including the scatter radiation from the object, the blur caused by the focal spot, geometric magnification and detector characteristics. For the tube voltages ranging from 40 to 90 kVp in 10 kVp increments at the FDD of 100, 110, 120, 150, 180 cm, the eDQE was evaluated at the same effective dose. The results showed that the eDQE was largest at 60 kVp when compares the eDQE at different tube voltage. Especially, the eDQE was considerably higher without the use of an anti-scatter grid on equivalent effective dose. This indicates that the reducing the scatter radiation did not compensate for the loss of absorbed effective photons in the grid. When the grid is not used the eDQE increased with increasing FDD because of the greater effective modulation transfer function (eMTF). However, most of major hospitals in Korea employed a short FDD of 100 cm with an anti-scatter grid for the chest radiological examination of a 15 month old infant. As a result, the entrance surface air kerma (ESAK) values for the hospitals of this survey exceeded the Korean DRL (diagnostic reference level) of $100{\mu}Gy$. Therefore, appropriate technical parameters should be established to perform pediatric chest examinations on children of different ages. The results of this study may serve as a baseline to establish detailed reference level of pediatric dose for different ages.

Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols (반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험)

  • Ha, Seongmin;Jung, Sunghee;Chang, Hyuk-Jae;Park, Eun-Ah;Shim, Hackjoon
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, we investigated the effects of an iterative reconstruction algorithm and an automatic exposure control (AEC) technique on image quality and radiation dose through phantom experiments with coronary computed tomography (CT) angiography protocols. We scanned the AAPM CT performance phantom using 320 multi-detector-row CT. At the tube voltages of 80, 100, and 120 kVp, the scanning was repeated with two settings of the AEC technique, i.e., with the target standard deviations (SD) values of 33 (the higher tube current) and 44 (the lower tube current). The scanned projection data were reconstructed also in two ways, with the filtered back projection (FBP) and with the iterative reconstruction technique (AIDR-3D). The image quality was evaluated quantitatively with the noise standard deviation, modulation transfer function, and the contrast to noise ratio (CNR). More specifically, we analyzed the influences of selection of a tube voltage and a reconstruction algorithm on tube current modulation and consequently on radiation dose. Reduction of image noise by the iterative reconstruction algorithm compared with the FBP was revealed eminently, especially with the lower tube current protocols, i.e., it was decreased by 46% and 38%, when the AEC was established with the lower dose (the target SD=44) and the higher dose (the target SD=33), respectively. As a side effect of iterative reconstruction, the spatial resolution was decreased by a degree that could not mar the remarkable gains in terms of noise reduction. Consequently, if coronary CT angiogprahy is scanned and reconstructed using both the automatic exposure control and iterative reconstruction techniques, it is anticipated that, in comparison with a conventional acquisition method, image noise can be reduced significantly with slight decrease in spatial resolution, implying clinical advantages of radiation dose reduction, still being faithful to the ALARA principle.

A Study on the Breakdown in MHEMTs with InAlAs/InGaAs Heterostructure Grown on the GaAs substrate (InAlAs/InGaAs/GaAs MHEMT 소자의 항복 특성에 관한 연구)

  • Son, Myung-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.11
    • /
    • pp.1-8
    • /
    • 2011
  • One of the most important parameters that limit maximum output power of transistor is breakdown. InAlAs/InGaAs/GaAs Metamorphic HEMTs (MHEMTs) have some advantages, especially for cost, compared with InP-based ones. However, GaAs-based MHEMTs and InP-based HEMTs are limited by lower breakdown voltage for output power even though they have good microwave and millimeter-wave frequency performance with lower minimum noise figure. In this paper, InAlAs/$In_xGa_{1-x}As$/GaAs MHEMTs are simulated and analyzed for breakdown. The parameters affecting breakdown are investigated in the fabricated 0.1-${\mu}m$ ${\Gamma}$-gate MHEMT device having the modulation-doped $In_{0.52}Al_{0.48}As/In_{0.53}Ga_{0.47}As$ heterostructure on the GaAs wafer using the hydrodynamic transport model of a 2D commercial device simulator. The impact ionization and gate field effect in the fabricated device including deep-level traps are analyzed for breakdown. In addition, Indium mole-fraction-dependent impact ionization rates are proposed empirically for $In_{0.52}Al_{0.48}As/In_xGa_{1-x}As$/GaAs MHEMTs.