• 제목/요약/키워드: Voltage collapse

검색결과 98건 처리시간 0.022초

Voltage Stability Prediction on Power System Network via Enhanced Hybrid Particle Swarm Artificial Neural Network

  • Lim, Zi-Jie;Mustafa, Mohd Wazir;Jamian, Jasrul Jamani
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.877-887
    • /
    • 2015
  • Rapid development of cities with constant increasing load and deregulation in electricity market had forced the transmission lines to operate near their threshold capacity and can easily lead to voltage instability and caused system breakdown. To prevent such catastrophe from happening, accurate readings of voltage stability condition is required so that preventive equipment and operators can execute security procedures to restore system condition to normal. This paper introduced Enhanced Hybrid Particle Swarm Optimization algorithm to estimate the voltage stability condition which utilized Fast Voltage Stability Index (FVSI) to indicate how far or close is the power system network to the collapse point when the reactive load in the system increases because reactive load gives the highest impact to the stability of the system as it varies. Particle Swarm Optimization (PSO) had been combined with the ANN to form the Enhanced Hybrid PSO-ANN (EHPSO-ANN) algorithm that worked accurately as a prediction algorithm. The proposed algorithm reduced serious local minima convergence of ANN but also maintaining the fast convergence speed of PSO. The results show that the hybrid algorithm has greater prediction accuracy than those comparing algorithms. High generalization ability was found in the proposed algorithm.

방사상 전력계통의 전압안정도 향상을 위한 최적 라우팅 기법에 관한 연구 (A Study on the Optimal Routing Technique for the Improvement of Voltage Stability in Radial Power System)

  • 김병섭;신중린;박종배
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권11호
    • /
    • pp.568-576
    • /
    • 2002
  • This paper presents a new algorithm for the enhancement of voltage stability by optimal routing (OR) technique. A new voltage stability index (VSI) for optimal routing is also proposed by using theories of critical transmission path based on voltage phasor approach and equivalent impedance method. Furthermore, the proposed algorithm automatically detect the critical transmission path to critical transmission path to critical load which are faced to voltage collapse due to additional real or reactive loading. We also adopt a improved branch exchange (IBE) algorithm based on a tie branch power (TBP) flow equation to apply the OR technique. The proposed IBE algorithm for the VSI maximizing can effectively search the optimal topological structures of distribution feeders by changing the open/closed states of the sectionalizing and tie switches. The proposed algorithm has been evaluated with the practical IEEE 32, 69 bus test systems and KEPCO 148 bus test system to show favorable performance.

증조류 선로 고장시 인접선로 과부하에 의한 거리계전기 동작 및 전압불안정 현상 연구 (A study of impedance relay operation and voltage instability caused by over load of neighborhood line at contingency of heavy load line)

  • 윤기섭;이형한;김창곤;안보순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.359-361
    • /
    • 2005
  • This paper presents the method of countermeasures before voltage collapse by load encroachment(impedance of load ability on R-X locus decrease toward zero point) and describes a study of impedance relay(zone-3) operation and voltage instability caused by over load of neighborhood line at contingency of heavy load line.

  • PDF

자기여자(Self-Excitation) 방지를 고려한 시송전 선로에 관한 연구 (Analysis Of The Primary Restorative Transmission System To Prevent Self-excitation)

  • 이흥재;김상섭;박성민;황봉환;이남호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.44-46
    • /
    • 2002
  • Service restoration following a complete or partial collapse starts with reenergize a transmission line from black-start generators. Voltage problems can arise by Ferranti effect as unloaded transmission line is reenergized. This paper presents analytical results on the primary restorative transmission system focused on the voltage problem during the early restoration process. Methodologies to handle load pick-up compensating Ferranti effect. and terminal voltage and reactive capability limitation of black-start generators about self-excitation are presented. An algorithm for static analysis about these methodologies is developed, and EMTDC simulation for verifying the efficiency of the algorithm is performed.

  • PDF

송전손실 상태식별법에 의한 정태 전압안정성 해석 (Static Voltage Stability Analysis based on T/L Loss System Identification)

  • 전동훈;김정훈;심건보;이봉용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.145-148
    • /
    • 1992
  • The best index should show the margins to the operating limit at the present operating point without much efforts. Such voltage collapse proximity index has been proposed in this study. Differently from the normal procedure in which every bus load is increased at the same propotion, bus load increase toward the direction of T/L loss increase has been applied in this study. Sample studies show the usefulness and the practical applicability in voltage stability analysis.

  • PDF

조셉슨 전압 표준을 위한 극저온(4.2K) X-밴드 HEMT 발전기의 설계 (Design of cryogenic(4.2K) X-band HEMT oscillator for josephson voltage standard)

  • 이문규;남상욱;엄경환;김규태
    • 전자공학회논문지D
    • /
    • 제35D권3호
    • /
    • pp.1-10
    • /
    • 1998
  • A new oscillator configuration is presented and tested for Josephson voltage standard operated at the cryogenic(4.2K) temperature. Features of active devices are investigated in aspects of 1/f noise, output power, and current collapse at low temperature. The output power of oscillator is optimized by a nonlinear design approach called Harmonic Two Signal Method(HTSM). The embedding newworks of the generalized six oscillators with tow loads are derived. A HEMT oscilliator is designed in X-Band for the Josephson voltage standard and tested at room and cryogenic(4.2K) temperatures. Oscillation frequency, output power, C/N ratio, and fequency stability are compared at room and low temperatures.

  • PDF

에너지함수에 의한 통합안정도해석 (Integrated Stability Analysis for Power Systems Using Energy Function)

  • 문영현;이응혁;이윤섭;오용택;김백
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.77-79
    • /
    • 1996
  • This paper presents an integrated stability analysis by the direct energy function method based on Equivalent Mechanical Model(EMM) which reflects the system behavior related to both angle and voltage stabilities. Actually, angle and voltage stability are intimately related in power system, so complete decoupling of these stability analysis is not possible in general, particularly in stressed power systems. In this paper, it is shown that a identical energy function can be used for angle and voltage stability analysis. The proposed energy function reflects the line resistances and reactive powers under the constraints of the same R/X ratio. The energy margin between UEP and SEP presents a good collapse proximity index in both types of stability analysis.

  • PDF

부하의 증가 패턴을 고려한 전압 안정도 직접 해석에 관한 연구 (A Study on the Voltage Stability Direct Analysis reflecting Load Increase Pattern)

  • 문영현;최병곤;노태훈;이응혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.80-83
    • /
    • 1996
  • This paper develops a method for reliably estimating an UEP(Unstable Equilibrium Point) which is located in the direction of SEP(Stable Equilibrium Point)'s moving as system load is getting heavy. As power systems are getting loaded heavily, the SEP which is an operable solution, and the UEP which is occurring voltage collapse, are moving toward each other linearly. The estimated UEP is used as a good initial guess for the real UEP. The proposed method is tested by 3 bus system and Stagg 5 bus system. It is demonstrated that the proposed method is very useful for assessing system voltage stability in the case of heavy loaded power system. The result solutions are often used in conjunction with energy methods and the stability margin.

  • PDF

A Study on Efficient Calculation of Effective Reactive Power Reserves Using Sensitivity Analysis

  • Bae, Moonsung;Lee, Byongjun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1689-1696
    • /
    • 2017
  • In recent academic and industrial circles of the Republic of Korea, the securement of available reactive power reserve against the line faults is at issue. Thus, simulations have been performed for the securing of effective reactive power reserve (effective Q) to prepare for the line faults and improve reactive power monitoring and control methods. That is, a research has been conducted for the fast-decoupled Newton-Raphson method. In this study, a method that distinguishes source and sink regions to carry out faster provision of information in the event of line fault has been proposed. This method can perform quantification with the formula that calculates voltage variations in the line flow. The line flow and voltage changes can be easily induced by the power flow calculation performed every second in the operation system. It is expected that the proposed method will be able to contribute to securement of power system stability by securing efficient reactive power. Also, the proposed method will be able to contribute to prepare against contingencies effectively. It is not easy to prepare quickly for the situation where voltage drops rapidly due to the exhaustion of reactive power source by observing voltage information only. This paper's simulation was performed on the large scale Korean power system in steady state.

방사상 전력계통의 전압안정도 향상에 관한 연구 (A Study on the Voltage Stability Enhancement in Radial Power System)

  • 김병섭;정윤원;신중린;박종배;채명석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.87-89
    • /
    • 2002
  • This paper presents a new approach using an Improved branch exchange (IBE) technique to maximize the voltage stability as well as loss minimization in radial power systems. A suitable voltage stability index (VSI) for optimal routing algorithm is developed using novel methods both a critical transmission path based on a voltage phasor approach and an equivalent impedance method. Furthermore, the proposed algorithm can automatically detect the critical transmission path to be reached to a critical load faced with voltage collapse due to additional real or reactive leading. To develop an effective optimization technique, we also have applied a branch exchange algorithm based on a newly derived index of loss change. The proposed IBE algorithm for VSI maximization can effectively search the optimal topological structures of distribution feeders by changing the open/closed states of the sectionalizing and tie switches. The proposed algorithm has been tested with the various radial power systems to show its favorable performance.

  • PDF