• Title/Summary/Keyword: Voltage active filter

Search Result 318, Processing Time 0.026 seconds

Anti-Windup Scheme to Control DC Voltage of Three-Phase Four-Wire Active Power Filter (누적방지 기법을 적용한 3상 4선식 능동전력필터 시스템의 직류전압 제어)

  • 정교범
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.128-136
    • /
    • 2003
  • This paper investigates the application of the anti-windup scheme to control U voltage of the three-phase four-wire active power filter, installed in a three-phase four-wire power system. In order to reduce efficiently the harmonic currents caused by the switching loads and to improve the whole performance of the flower system, the DC voltage of the three-phase four-wire active power filter should be properly controlled. PI controller can be applied to the U voltage controller of the three-phase four-wire active power filter. However, a large error input to PI controller leads to a windup phenomenon which deteriorate the dynamic characteristics of the U voltage controller Therefore, the application of the anti-windup scheme for the DC voltage controller is proposed and the improved performances of the anti-windup U voltage controller are proved through the computer simulation study.

AC harmonic elimination and reactive power compensation by voltage-type active filter (전압형 능동필터에 의한 교류고조파제거와 무효전력보상)

  • 김한성;최규하;신우석;이제필
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.688-692
    • /
    • 1988
  • The active filter system for harmonic current compensation is presented in this paper. The active filter, composed of a three-phase voltage-type PWM inverter and the capacitor, compensates both the harmonic currents and the reactive power by injecting the PWM current to the ac line. This paper describes the principle of harmonic current compensation, the calculation circuits for the harmonic currents to be injected, the several compensation characteristics. Also the experimental results are shown to verify the theory proposed in this paper.

  • PDF

Active Power Filter Compensating for Source Voltage Unbalance/Current Harmonics and Power Factor Correction (전원 전압의 불평형과 고조파 전류 보상 및 역률 개선 기능을 가지는 능동전력 필터)

  • Lee Jong-Kun;Seok Jul-Ki;Lee Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.787-790
    • /
    • 2004
  • In this paper, a novel control scheme compensating for source voltage unbalance and current harmonics and power factor correction in unified active power filter systems combined with shunt passive filters is proposed, where no low/high-pass filter are used in deriving the reference voltage for compensation. Using digital all-pass filters, the phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage. The amplitude of d-axis current in a series filter is controlled as zero for power factor correction. The validity of the proposed control scheme has been verified by experimental results.

  • PDF

Unified Active Power Filter Compensating For Source Voltage Unbalance/Current Harmonics and Power Factor Simultaneously (전원 전압의 불평형과 고조파 전류 및 역률을 동시에 보상하는 통합형 능동 전력필터)

  • Lee, Jong-Kun;Seok, Jul-Ki;Lee, Dong-Choon
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.103-105
    • /
    • 2004
  • In this paper, a novel control scheme compensating for source voltage unbalance and current harmonics and power factor simultaneously in unified active power filter systems combined with shunt passive filters is proposed, where no low/high-pass filter are used in deriving the reference voltage for compensation. Using digital all-pass filters, the phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage. The amplitude of d-axis current in a series filter is controlled as zero for power factor correction. The validity of the proposed control scheme has been verified by experimental results.

  • PDF

A Study on the Three-Phase Active Power Filter using Predictive Current Control Method (예측전류제어방식을 이용한 3상 능동전력필터에 관한 연구)

  • Kwon, Byung-Gi;Woo, Myung-Ho;Jeong, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.138-140
    • /
    • 1994
  • In this paper, a three-phase active power filter using voltage- source PWM converter is designed to eliminate the harmonics and compensate the reactive power in the ac side. The predictive current control method is adopted, which provides constant switching frequency and low current ripple but has inherently one sampling error between the command and the actual current. Here we propose the algorithm which corrects this delay time. The converter voltage obtained from this current control can be accomplished by the space vector modulation method at a voltage-type converter. All control sequences of active filter is executed by a DSP which is designed to calculate floating points at very hight speed. Finally, the validity of this filter using the predictive current control method is demonstrated through experimental results.

  • PDF

Single-Tuned Active Filter with Function of Double-Tuned Active Filter (Double Tuned Active Filter 기능을 갖는 Single Tuned Active Filter)

  • Kim Chan-Ki;Yang Byeong-Mo;Jung Gil-Jo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.544-552
    • /
    • 2004
  • This paper deals with the hybrid active filter which can reduce the 11th/13th harmonics in AC network by using the single tuned filter. Since the proposed algorithm uses the detuning compensation capability of the filter, the output voltage of the proposed active power filter is changed according to the capacitance of capacitors, magnitude of harmonic current, resonance frequency and control mode. In this paper, the control characteristics and the design of hybrid active filter is investigated. A new hybrid active filter with new algorithm, which is an active filter with single tuned filter instead of double tuned filter, is proposed.

Power Quality Impacts of an Electric Arc Furnace and Its Compensation

  • Esfandiari Ahmad;Parniani Mostafa;Mokhtari Hossein
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.153-160
    • /
    • 2006
  • This paper presents a new compensating system, which consists of a shunt active filter and passive components for mitigating voltage and current disturbances arising from an Electric Arc Furnace (EAF). A novel control strategy is presented for the shunt active filter. An extended method based on instantaneous power theory in a rotating reference frame is developed for extraction of compensating signals. Since voltages at the point of common coupling contain low frequency interharmonics, conventional methods cannot be used for dc voltage regulation. Therefore, a new method is introduced for this purpose. The passive components limit the fast variations of load currents and mitigate voltage notching at the Point of Common Coupling (PCC). A three-phase electric arc furnace model is used to show power quality improvement through reactive power and harmonic compensation by a shunt active filter using the proposed control method. The system performance is investigated by simulation, which shows improvement in power quality indices such as flicker severity index.

A Study of Control Algorithm For Series Active Power Filter Using Performance Function (성능함수를 이용한 직렬형 능동전력필터의 제어알고리즘에 관한 연구)

  • Ko Soo-Hyun;Kim Jin-Sun;Kim Young-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.199-202
    • /
    • 2002
  • This paper suggests the control algorithm of a 3-phase 3-wire series active power filters which have harmonic voltage source and harmonic current source This suggested control algorithm can compensate harmonics which are generated by nonlinear load such as diode or thyristor converter and reactive power in 3-phase 3-wire power distribution system This control algorithm extracts a compensation voltage reference from performance function without phase transformation Therefore this control algorithm is simpler than any other conventional control algorithm. 3-phase 3-wire series active power filter and hybrid active power filter is manufactured and experiments are carried out for harmonic voltage source and harmonic current source to verify the effectiveness of presented control algorithm Experimental results are presented in this Paper, as well.

  • PDF

Three-Phase Z-Source Hybrid Active Power Filter System (3상 Z-소스 하이브리드 능동전력필터 시스템)

  • Lim, Young-Cheol;Kim, Jae-Hyun;Jung, Young-Gook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.75-85
    • /
    • 2010
  • In this paper, a Z-source hybrid active power filter is proposed to compensate the harmonics and reactive power in power distribution system. The proposed system is composed of a 7th harmonics-tuned passive filter and an active power filter with a Z-source inverter topology, while voltage source PWM inverter or current source PWM inverter are applied as the power converter topology of conventional active power filters. The Z-source impedance network along with shoot through capability would ensure a constant DC voltage across the DC link. A polymer electrolyte membrane fuel cell is employed as an compensation DC energy source of the proposed system and its equivalent R-L-C circuit is modeled for simulation. As the compensation and control algorithm of the proposed system, the current synchronous detection algorithm is applied. The simulation analysis by PSIM is performed under the three-phase 220V/60Hz voltage source and 25A nonlinear diode loads. The effectiveness of the proposed the system is verified in the steady and transient states.

A Series Active Power Filter For Harmonic Currents And Reactive Power Compensation (고조파 전류와 무효전력보상을 위한 직렬형 능동전력필터)

  • 김진선;고수현;김영석
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.221-229
    • /
    • 2003
  • This paper suggests a control algorithm of 3-phase 3-wire series active power filter. This suggested algorithm can compensate source harmonics and reactive power in 3-phase 3-wire power distribution systems. These harmonics are generated by nonlinear loads such as diode rectifiers and thyristor converters. This control algorithm extracts a compensation voltage reference from performance function without phase transformation. Therefore, this control algorithm is simpler than any other conventional control algorithms. 3-phase 3-wire series active power filters which have a harmonic voltage source and a harmonic current source are manufactured and experiments are carried out to verify the effectiveness of suggested control algorithm.