• Title/Summary/Keyword: Voltage Application Time

Search Result 431, Processing Time 0.037 seconds

The experimental study of $\gamma$ ray irradiation effect on electrical properties of B-kind insulator ($\gamma$선조사에 의한 B종절연재료의 전기적 특성변화에 대한 실험적 연구)

  • 천희영;성영권;이덕출
    • 전기의세계
    • /
    • v.18 no.2
    • /
    • pp.15-20
    • /
    • 1969
  • The main focus of this paper is on the study of the .gamma. ray irradiation effect upon the electrical properties of a B-kind insulator which is one of the inorganic insulators. The mica is so typical of the B kind insulators as to be selected for a sample. DC, AC, and Impulse voltage is applied to the variable .gamma. ray irradiated dose samples with the constant time duration and the time variable samples with the .gamma. ray irradiated dose. The dielectric breakdown voltage and dielectric constant are measured from the samples and we get the experimental data that the dielectric breakown voltage variations are relatively large, but the dielectric constants are almost constant. The above conclusion is useful for the selection and application of the inorganic insulators under the irradiation effects, and we expect that the conclusion can apply to not only B-kind insulators but also the inorganic insulators.

  • PDF

An Energy Optimization Technique for Latency and Quality Constrained Video Applications (지연 시간 및 화질 제약이 있는 비디오 응용을 위한 에너지 최적화 기법)

  • 임채석;하순회
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.10
    • /
    • pp.543-552
    • /
    • 2004
  • This paper proposes an energy optimization technique for latency and quality constrained video applications. It consists of two key techniques: frame-skipping technique and buffering technique. While buffering increases the slack time utilization at the OS level. frame skipping Increases the slack time itself at the application level, and both enhance the effectiveness of the dynamic voltage scaling technique. We use an H.263 encoder application as a test vehicle to which the proposed technique is applied. Experiments demonstrate that the proposed technique achieves noticeable energy reduction satisfying the given latency and video quality constraints.

A Study on the Electrical Diagnostic Methods In GIS (GIS에 있어서 전기적 절연진단법에 대한 연구[1])

  • Choi, Jae-Gu;Kim, Young-Bae;Kim, Ik-Soo;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.904-906
    • /
    • 1998
  • PD pulses have about one nanosecond rise time in the $SF_6$ gas insulation. These pulses propagate in the apparatus to PD sensors in the form of the voltage oscillation, high frequency current and the electromagnetic radiation. In this paper, we investigated the characteristics of two types of PD sensors, by putting high frequency signals in the form of sine waves and pulse into the test apparatus in air. Also, we measured PD quantity from the needle electrode and the sensitivity of the sensors. We found that PD of 70pC could be detected with this method and the study in $SF_6$ gas should be carried out for application to $SF_6$ GIS.

  • PDF

Insulation Evaluation of Low-voltage Induction Motors by Surge Voltages (서지전압에 의한 저압유도전동기의 절연평가)

  • Choi, Su-Yeon;Choi, Jae-Sung;Park, Dae-Won;Kil, Gyung-Suk;Song, Jae-Yong
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1892-1896
    • /
    • 2008
  • Inverter-fed induction motors (IFM) are prevalent in traction vehicles. However, the winding insulation of IFM is substantially more stressed than of line-powered motors by surge voltages. Consequently, the winding insulation of IFM should be estimated by surge voltages. Also, the weakness of coil insulation can be detected by the surge voltage test. This paper described the insulation evaluation of induction motors by application of surge voltages. A surge voltage generator with the maximum voltage of 5 kV and the selectable rise-time in ranges of $50\;ns\;{\sim}\;500\;ns$ was fabricated. In the experiment, we applied surge voltages into induction motors with the magnitude and the risetime according to IEEE 522. By the analysis of applied surge voltage and current waveforms, we could find difference between normal and defection windings.

  • PDF

BESS Modeling and Application to Voltage Compensation of Electric Railway System (BESS 모델링 및 전기철도 급전계통에의 전압보상 적용)

  • Yoo, Hyeong-Jun;Son, Ho-Ik;Kim, Hak-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.417-423
    • /
    • 2013
  • The load of electric railroad can generate voltage fluctuation in the electric railway system because of high speed of the electric railroad and frequent movement and stop. This voltage fluctuation of electric railway system can cause not only voltage imbalance but also harmonic in the utility grid. Therefore the electric railroad system is in need of the reactive power compensation, such as static synchronous compensator (STATCOM) and static var compensator (SVC). Especially, the battery energy storage system (BESS) can control the real and reactive power at the same time. In this paper, the electric railway system using BESS has been modeled to show its voltage compensation effect using Matlab/Simulink.

Augmented Reality based Low Power Consuming Smartphone Control Scheme

  • Chung, Jong-Moon;Ha, Taeyoung;Jo, Sung-Woong;Kyong, Taehyun;Park, So-Yun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.10
    • /
    • pp.5168-5181
    • /
    • 2017
  • The popularity of augmented reality (AR) applications and games are in high demand. Currently, the best common platform to implement AR services is on a smartphone, as online games, navigators, personal assistants, travel guides are among the most popular applications of smartphones. However, the power consumption of an AR application is extremely high, and therefore, highly adaptable and dynamic low power control schemes must be used. Dynamic voltage and frequency scaling (DVFS) schemes are widely used in smartphones to minimize the energy consumption by controlling the device's operational frequency and voltage. DVFS schemes can sometimes lead to longer response times, which can result in a significant problem for AR applications. In this paper, an AR response time monitor is used to observe the time interval between the AR image input and device's reaction time, in order to enable improved operational frequency and AR application process priority control. Based on the proposed response time monitor and the characteristics of the Linux kernel's completely fair scheduler (CFS) (which is the default scheduler of Android based smartphones), a response time step control (RSC) scheme is proposed which adaptively adjusts the CPU frequency and interactive application's priority. The experimental results show that RSC can reduce the energy consumption up to 10.41% compared to the ondemand governor while reliably satisfying the response time performance limit of interactive applications on a smartphone.

A PDPWM Based DC Capacitor Voltage Control Method for Modular Multilevel Converters

  • Du, Sixing;Liu, Jinjun;Liu, Teng
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.660-669
    • /
    • 2015
  • This paper presents a control scheme with a focus on the combination of phase disposition pulse width modulation (PDPWM) and DC capacitor voltage control for a chopper-cell based modular multilevel converter (MMC) for the purpose of eliminating the time-consuming voltage sorting algorithm and complex voltage balancing regulators. In this paper, the convergence of the DC capacitor voltages within one arm is realized by charging the minimum voltage module and discharging the maximum voltage module during each switching cycle with the assistances of MAX/MIN capacitor voltage detection and PDPWM signals exchanging. The process of voltage balancing control introduces no extra switching commutation, which is helpful in reducing power loss and improving system efficiency. Additionally, the proposed control scheme also possess the merit of a simple executing procedure in application. Simulation and experimental results indicates that the MMC circuit together with the proposed method functions very well in balancing the DC capacitor voltage and improving system efficiency even under transient states.

Motor Bus Residual Voltage Characteristics at Nuclear Power Plant (원자력발전소 고압전동기 모선 잔류전압 특성)

  • Byun, Sang-Youn;Kim, Sun-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.662_663
    • /
    • 2009
  • Motor bus transfer involves the process of transferring a bus that has several critical motors to an alternate source of power when the main normal power source feeding them is interrupted. Bus transfer is a time-critical application in which the transfer progress depends on various parameters such as the type of motor, load on the motor at the time of transfer, inertia of the motor, and the combined open-circuit time constant of various motors present on the bus at the time of transfer. This paper present the result of modeling and simulation of nuclear power motor bus using ETAP(Electrical Transient Analyzing Program) program for motor and motor bus residual voltage decay characteristics.

  • PDF

The Application of Real Time Digital Simulator for Analyzing the Performance of Power System Stabilizer(PSS) (전력계통 안정화장치(PSS)의 성능 분석을 위한 실시간 디지털 시뮬레이터 응용)

  • Hur, Jin;Kim, Dong-Joon;Moon, Young-Hwan;Shin, Jeong-Hoon;Kim, Tae-Kyun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.9
    • /
    • pp.459-466
    • /
    • 2000
  • The performance of a commercialized power system stabilizer (PWX-600) for a single hydro-turbine generator and infinite bus system has been investigated using Real Time Digital Simulator (RTDS) in this paper. The test system was composed of RTDS, three phase voltage/current amplifier and the PSS. The test scheme provided a very efficient way to verify the design and control performance of a PSS to be applied to real power system. The scheme can also be applied to verify in real time the performance of hardware and software of power system controllers for FACTS and protective relays effectively.

  • PDF

A Voltage Disturbance Detection Method for Computer Application Lods (컴퓨터 응용 부하들을 위한 전압 외란 검출 방법)

  • 이상훈;최재호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.6
    • /
    • pp.584-591
    • /
    • 2000
  • Power Quality Compensator(PQC) has been installed to protect the sensitive loads against the voltage disturbances, such as voltage sag and interruption. In general, static switch is used for the purpose of link between utility and PQC. So transfer operation of the static switch play a important part in the PQC. Many studies on the structure and control of PQC have been progressed in active, but these researches have been rarely mentioned about any voltage-disturbances-detection method to start the PQC operation. In this paper, a new voltage-disturbances-detection algorithm for computer application loads using the CBEMA/ITIC curve is proposed for transfer operation of the static switch. The proposed detection algorithm is implemented to get fast detecting time through the comparison of instantaneous 3-phase voltage values transferred to DC values in the synchronous reference frame with the operating reference values. To get the robust characteristics against the noise, a first order digital filter is designed. The magnitude falling and phase delay caused by the filter are compensated through the error normalizing and numerical analysis using transfer function, respectively. Finally, the validity of the proposed algorithm is proved by ACSL simulation and experimental results.

  • PDF