• Title/Summary/Keyword: Volatile Organic compounds

Search Result 1,287, Processing Time 0.024 seconds

Physicochemical and Microbial Properties of Korean Traditional Rice Wine, Makgeolli, Supplemented with Cucumber during Fermentation (오이를 첨가한 막걸리의 발효기간 중 이화학적 및 미생물학적 특성)

  • Kim, Sang-Yun;Kim, Eun-Kyung;Yoon, Seong-Jun;Jo, Nam-Ji;Jung, Soo-Kyung;Kwon, Sang-Ho;Chang, Yoon-Hyuk;Jeong, Yoon-Hwa
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.2
    • /
    • pp.223-228
    • /
    • 2011
  • Korean traditional rice wine, Makgeolli, has been widely consumed with increasing popularity in Korea. Also, there has been an increase in the varieties of Makgeolli for the younger generation. In this study, we examined the physicochemical and microbial properties of Makgeolli supplemented with cucumber during fermentation. Four hundred grams of cucumbers (20% of the total amount of rice) were grinded and added to the rice solution (2 kg rice and 3.12 L distilled water) along with the Nuruk (40 g) and yeast (14 g). After mixing the solution, it was fermented for six days in a water bath ($28^{\circ}C$). During the fermentation, the pH value of the cucumber Makgeolli fell from 5.88 to 3.94 on day-1, and steadily increased to a pH value of 4.48 by day-6. The total acidity of the cucumber Makgeolli sharply increased from 0.02 to 0.20% on day-1, and then slowly increased thereafter to 0.28% by day-6. After the 6-day fermentation, the L values of the control and the cucumber Makgeolli were similar. The total viable cell, lactic acid bacteria and yeast count of the control and the cucumber Makgeolli increased considerably after the 6-day fermentation process. Free sugar analysis showed that glucose contents decreased with increasing fermentation periods. The succinic acid content was the highest among all the organic acids. Thirty-nine volatile compounds were observed on the final day of fermentation in the cucumber Makgeolli.

Critical Evaluation of and Suggestions for the VOCs Measurement Method Established as the Korean Indoor Air Quality Standard Method (실내공기질 공정시험법 중 VOCs 측정방법의 문제점 고찰 및 개선방안에 관한 연구)

  • Ye, Jin;Jung, Dong-Hee;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.586-599
    • /
    • 2014
  • During the last two decades, indoor air quality and volatile organic compounds (VOCs) have been of concern in Korean society due to their nature of potential health impacts. In order to investigate the pollution levels of VOCss in indoor environments, establishment of a solid test method for monitoring the airborne VOCss is essential. In Korea, a method based on adsorbent sampling and GC analysis coupled with thermal desorption was proclaimed as the Korea Standard Method for Indoor Air Quality Test. This study was carried out to examine some inherent problems of the VOCs measurement method. The VOCs method does not describe in detail preparing the standard samples. The standard samples may be prepared by impregnation of either liquid standard solutions or a mixture of standard gases. In this study, we investigated the optimal temperature condition for transferring the liquid standards onto a standard adsorbent tube. As a result, keeping the impregnation temperature at $250^{\circ}C$ will be recommended in regard of the boiling points of multiple target analytes and the thermal stability of the adsorbent. We also demonstrated some problems associated with handling of a syringe used for transferring the standard solutions onto the adsorbent tubes, and a best way to get rid of the syringe problems was suggested. Finally, a number of field works were conducted to evaluate the performance of adsorbent sampling methods. Comparison of different adsorbent tubes, i.e. tube packed with single sorbent (Tenax) and double sorbents (Tenax with Carbotrap), revealed that 30 to 40% differences between the two groups, implying that sampling efficiency is depending on the volatility and the strength of adsorbents. However, duplicate precisions for VOCs sampling with a same type of adsorbent and at same flow rates appeared to be satisfactory to be all within 20%, which is a quality control guideline. Distributed volume precisions were also found to be within a guideline value, 25%, although the precision was in general inferior to the duplicate precision. The Korea indoor VOCs test method should be more refined and improved in many aspects, particularly procedure and instrumentation for preparing the standard samples and specification of quality control assessment.

Development of Source Profiles and Estimation of Source Contribution for Hazardous Air Pollutants by the Principal Component Analysis in Indoor Air

  • Kim, Yoon-Shin;Hong, Seoung-Cheol;Lee, Cheol-Min;Kim, Jong-Cheol;Jeon, Hyung-Jin;Song, Kyoung-Min;Roh, Young-Man
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.254-258
    • /
    • 2005
  • The purpose of this study is to characterize the indoor-outdoor relationship of airborne pollutants and recognize probable sources in inside and outside individual apartments in Seoul metropolitan. Simultaneous air monitoring in inside and outside of the 16 Korean Apartments classified into 2groups: less than 1 year old and more than 4 years old from October, 2004 to February, 2005were sampled f3r airborne pollutants(volatile organic compounds, formaldehyde, respiratory particles, carbon dioxide and bacteria) using the Korean Indoor Air Quality Official Method. The concentrations of $CO_2$, TVOCs, HCHO, bacteria and PM10 in the less than 1 year old apartments were determined to be $773.6{\pm}422.3ppm$, $4,393.8{\pm}2,758.2{\mu}g/m^3$, $98.0{\pm}56.4{\mu}g/m^3$, $254.0{\pm}186.3CFU/m^3$ and $31.7{\pm}14.8{\mu}g/m^3$, respectively, Also, the concentrations of those in the more than 4 years old apartments were determined to be $798.9{\pm}266.5ppm$, $792.7{\pm}398.3{\mu}g/m^3$, $70.0{\pm}30.7{\mu}g/m^3$, $245.6{\pm}122.0CFU/m^3$, $49.7f28.7{\pm}g/m^3$, respectively. The average ratios of the indoor and outdoor concentrations of $CO_2$, TVOCs, HCHO, bacteria and PM10 were 2.2, 3.6, 3.1, 3.9 and 1.4, respectively. These results of this analysis is suggested that $CO_2$, TVOCs, HCHO, bacteria and PM10 in indoor air are both emitted from source within the apartment environment and partly come from outdoor air. With the above considerations in mind, it is suggested that the research for source contribution of indoor air pollutants should be expanded and the detailed interpretation of the results on these needed further study(using principal component analysis(PCA).

  • PDF

Assessment of VOCs Emission Characteristics from Building Materials such as Wall Paper, Paints, and Adhesives Using Small Chamber Method (소형챔버법을 이용한 건축자재 중 벽지, 페인트 및 접착제의 VOCs 방출특성 평가)

  • Lee Suk-Jo;Jang Seong-Ki;Cho Yong-Sung;Jung Kyung- Mi;Jeong Gi-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.191-204
    • /
    • 2005
  • Building and furnishing materials and consumer product are important sources of volatile organic compounds(VOCs) and other aldehydes in the indoor environment. Some available evidence indicates that VOCs can cause adverse health effects to the building occupants and contribute to some of the symptoms of what we call, 'Sick House Syndrome' in Korea. The aims of this study were to evaluate the efficiency of emission system and to investigate comparison of the emission characteristics of different building materials such as wall-papers, paints, and adhesives. The emission of VOCs from building materials were determined in the small chambers defining the temperature, relative humidity, and ventilation rate in this study. VOCs were sampled for 20 minutes using Tenax-TA tubes and analysed by GC-MS with thermal desorption. The stability of conditions for temperature and relative humidity in this small chamber system showed that the fluctuation of temperature was between 25.4$\pm$0.3$^{\circ}C$ and that of relative humidity was 50.2$\pm$0.6$\%$ under the airflow rate of 167 mL/min. The emission tests from building materials resulted in TVOC emission rates of 0.011 $\~$ 3.108 mg/m$^{2}$h after 7 days. The general wall-papers emitted toluene abundantly and the natural wall-papers mainly emitted n-butanol and a minor amount of alkanes compound such as n -tetradecane. The remainder consisted of toluene, m,p -xylene, and styrene. The paints mainly emitted toluene and the adhesives mainly emitted chloroform as well as toluene. As a result, this study is expected to suggest meaningful data for future studies in exposure control through selecting healthy building materials and for the establishment of guidelines for various building materials in Korea.

Effects of Concrete and Wood Building Environments on Pregnant Dams and Embryo-Fetal Development in Rats

  • Shin, In-Sik;Kim, Sung-Hwan;Lim, Jeong-Hyeon;Lee, Jong-Chan;Park, Na-Hyeong;Shin, Dong-Ho;Moon, Chang-Jong;Kim, Sung-Ho;Kim, Jong-Choon
    • Toxicological Research
    • /
    • v.25 no.4
    • /
    • pp.209-216
    • /
    • 2009
  • We have recently reported that the continuous exposure of rats to a concrete building environment under cool temperatures had adverse effects on general health parameters and embryo-fetal development. This study examined to compare the potential effects of concrete and wood building environments on pregnant dams and embryo-fetal development in rats. Groups of 10 mated females were exposed to polycarbonate (control), concrete, or wood cages from gestational days (GD) 0 to 20 under cool temperatures $(11.9\sim12.3^{\circ}C)$. All the females underwent a caesarean section on GD 20, and their fetuses were examined for any morphological abnormalities. The temperatures in the cages were similar in all groups but the relative humidity in the concrete and wood groups were higher than in the control group. The concentration of volatile organic compounds in the wood group was higher than in the control group. In the concrete group, maternal effects manifested as an increase in the incidence of clinical signs, a lower body weight, and a decrease in the thymus and ovary weights. Developmental effects included increased post-implantation loss and decreased litter size. Infrared thermal analysis showed that the skin temperature of the rats in the concrete group was lower than that in the control group. In contrast, there were no exposure-related adverse effects on the maternal and developmental parameters in the wood group. Overall, the exposure of pregnant rats to a concrete building environment under cool temperatures has adverse effects on the clinical signs, body weight, skin temperature, organ weight, and embryo-fetal development. On the other hand, exposure to a wood building environment does not have any adverse effects in rats.

Risk Assessment of Volatile Organic Compounds (VOCs) and Formaldehyde in Korean Public Facilities: Derivation of Health Protection Criteria Levels

  • Kim, Ho-Hyun;Lim, Young-Wook;Shin, Dong-Chun;Sohn, Jong-Ryeul;Yang, Ji-Yeon
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.121-133
    • /
    • 2011
  • This study suggests criteria to conduct a risk assessment of VOCs and formaldehyde in uncontrolled public facilities. Pollutants and facilities were selected based on two years of monitoring data and exposure scenarios in 573 uncontrolled public facilities, composed of 10 types of public institutions. With the exception of social welfare facilities, lifetime ECRs of formaldehyde and benzene in each facility were higher in employees than in users, except in social welfare facilities. In social welfare facilities, the risk of benzene for users ($1{\times}10^{-5}$) was higher than that of workers ($1{\times}10^{-6}$) because facility users live in the facility 24 hours per day, compared to workers who spend an average of 8 hours per day in the facility. The risk of benzene to workers in restaurants, academies, performance halls, internet cafe and pubs were estimated as high as $1{\times}10^{-4}$ and the risk to workers in the theaters and karaoke bars were recorded as $1{\times}10^{-5}$. Because lifetime ECRs of carcinogens exceeded $1{\times}10^{-4}$ for workers and users in most facilities, risk management of formaldehyde and benzene in these facilities is necessary. Although HQs of toluene and xylenes did not exceed 1.0, their HQs did exceed 0.1 in some facilities, so they were evaluated as potentially harmful materials. Additionally, criteria for health protection in IAQ by facility are suggested at $60-100\;{\mu}g/m^3$ for formaldehyde, $400-500\;{\mu}g/m^3$ for TVOCs, $10-20\;{\mu}g/m^3$ for benzene, $150-170\;{\mu}g/m^3$ for toluene and $100\;{\mu}g/m^3$ for xylenes, based on the survey on IAQ and HRA methodology. The excess rates of IAQ to health protection criteria in all facilities were 16% for formaldehyde, 8% for TVOCs and benzene, 9% for toulene, and 5% for xylenes.

Diurnal Variations of O3 and NO2 Concentrations in an Urban Park in Summer: Effects of Air Temperature and Wind Speed (여름철 도심 공원의 O3과 NO2 농도의 일변화: 기온과 풍속의 영향)

  • Han, Beom-Soon;Kwak, Kyung-Hwan;Baik, Jong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.536-546
    • /
    • 2016
  • The diurnal variations of $O_3$ and $NO_2$ in an urban park and the effects of air temperature and wind speed on the diurnal variations are investigated. $O_3$ and $NO_2$ concentrations were observed at a site in an urban park of Seoul from 27 July 2015 to 9 August 2015. The $O_3$ and $NO_2$ concentrations observed in the urban park are compared to those observed at the Gangnam air quality monitoring station (AQMS). The $O_3$ concentration is higher in the urban park than at the Gangnam AQMS in the daytime because the amount of $O_3$ dissociated by NO is smaller as well as partly because the amount of $O_3$ produced in the oxidation process of biogenic volatile organic compounds (VOCs) is larger in the urban park than at the Gangnam AQMS. The $NO_2$ concentration is lower in the urban park than at the Gangnam AQMS during day and night because the observation site in the urban park is relatively far from roads where $NO_x$ is freshly emitted from vehicles. The difference in $NO_2$ concentration is larger in the daytime than in the nighttime. To examine the effects of air temperature and wind speed on the diurnal variations of $O_3$ and $NO_2$, the observed $O_3$ and $NO_2$ concentrations are classified into high or low air temperature and high or low wind speed days. The high $O_3$ and $NO_2$ concentrations in the daytime appear for the high air temperature and low wind speed days. This is because the daytime photochemical processes are favorable when the air temperature is high and the wind speed is low. The scatter plots of the daytime maximum $O_3$ and minimum $NO_2$ concentrations versus the daytime averages of air temperature and wind speed show that the daytime maximum $O_3$ and minimum $NO_2$ concentrations tend to increase as the air temperature increases or the wind speed decreases. The daytime maximum $O_3$ concentration is more sensitive to the changes in air temperature and wind speed in the urban park than at the Gangnam AQMS.

High Concentrated Toluene Decomposition by Non-thermal Plasma-Photocatalytic (Mn-Ti-MCM-41) Hybrid System (상온 방전 플라즈마-광촉매(Mn-Ti-MCM-41) 복합 시스템에 놓인 고농도 톨루엔의 분해성능)

  • Ban, Ji-Young;Son, Yeon-Hee;Lee, Sung-Chul;Kang, Misook;Choung, Suk-Jin;Sung, Joon-Yong
    • Applied Chemistry for Engineering
    • /
    • v.16 no.3
    • /
    • pp.413-421
    • /
    • 2005
  • This study focused on the decomposition of toluene in a plasma-photocatalytic hybrid system. Hexagonally packed meso-structured Mn-titanosilicates (Mn-Ti-MCM-41), as the photocatalysts, have been prepared by the hydrothermal method. The physical properties of the photocatalysts were characterized using XRD, XPS, TEM, BET/ICP, and $NH_3$/Toluene-TPD. Experiments were carried out at the applied voltage of 9.0 kV and at room temperature of $20^{\circ}C$. In the plasma only system, the activity of the toluene decomposition was higher than that in the photocatalytic system. However, the amount of by-products, such as phenol, $C_2{\sim}C_4$ alkene, was also increased in the plasma only system. However, the by-products decreased remarkably in a plasma-photocatalytic hybrid system. When Mn5mol%-Ti-MCM-41 was used as a photocatalyst in a plasma-photocatalytic hybrid system, the $CO_2$ selectivity in products was increased dramatically compared to other catalysts. It was confirmed that a plasma-photocatalytic hybrid system was better for toluene decomposition compared to photocatalytic and plasma only systems.

Sensitivity of Ozone to NOx and VOCs in a Street Canyon (도로 협곡에서 NOx와 VOCs에 대한 오존의 민감도)

  • Lee, Kwang-Yeon;Kwak, Kyung-Hwan;Park, Seung-Bu;Baik, Jong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.3
    • /
    • pp.307-316
    • /
    • 2013
  • The sensitivity of ozone to $NO_x$ and volatile organic compounds (VOCs) emission rates under different ventilation rates and $NO_2-to-NO_x$ emission ratios in a street canyon is investigated using a chemistry box model. The carbon bond mechanism IV (CBM-IV) with 36 gaseous species and 93 chemical reactions is incorporated. $NO_x$ and VOCs emission rates considered range from 0.01 to $0.30ppb\;s^{-1}$ with intervals of $0.01ppb\;s^{-1}$. Three different ventilation rates and three different $NO_2-to-NO_x$ emission ratios are considered. The simulation results show that the ozone concentration decreases with increasing $NO_x$ emission rate but increases with increasing VOCs emission rate. When the emission ratio of VOCs to $NO_x$ is smaller than about 4, the ozone concentration is lower in the street canyon than in the background. On average, the magnitude of the sensitivity of ozone to $NO_x$ emission rate is significantly larger than that to VOCs emission rate. As the $NO_x$ emission rate increases, the magnitude of the sensitivity of ozone to $NO_x$ and VOCs emission rates decreases. Because the ozone concentration is lower in the street canyon than in the background, the increased ventilation rate enhances ozone inflow from the background. Therefore, the increase in ventilation rate results in the increase in ozone concentration and the decrease in the magnitude of the sensitivity of ozone to $NO_x$ and VOCs emission rates when the emission ratio of VOCs to $NO_x$ is smaller than about 4. On the other hand, the increase in $NO_2-to-NO_x$ emission ratio results in the increase in ozone concentration because the chemical ozone production due to the $NO_2$ photolysis is enhanced. In the present experimental setup, the contribution of the change in $NO_2-to-NO_x$ emission ratio to the change in the sensitivity of ozone to $NO_x$ emission rate is larger than that of the change in ventilation rate.

The Removal of Styrene using Immobilized Microorganisms in Hydrogel Beads (미생물 고정화 복합고분자담체를 이용한 Styrene 제거)

  • Song, Ji-Hyeon;Ham, Eun-Yi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.648-653
    • /
    • 2006
  • As an alternative for the traditional materials packed in biofilters treating gaseous VOCs, a novel packing material has been developed and tested. In the packing material(named as Hydrogel Bead, HB), pollutant-degrading microorganisms were immobilized in hydrogel consisted of alginate, polyvinyl alcohol(PVA), and powdered activated carbon. A closed-bottle study showed that the HB rapidly removed gaseous styrene without the losses of adsorption and biodegradation capacity. Biofilter column experiments using the HBs also demonstrated that greater than 95% of removal efficiencies were found at an inlet styrene loading rate of $245g/m^3/hr$, which was higher biofilter performance than other elimination capacity reported earlier. Furthermore, when the inlet styrene concentration increased stepwise, the adsorption played an important role in overall styrene removals. The absorbed styrene was found to be biodegraded in the following low inlet loading condition. Consequently, the new HB material is able to successfully minimize the drawbacks of activated carbon(necessity of regeneration) and biological processes(low removal capacity at dynamic loading conditions), and maximize the overall performance of biofilter systems treating VOCs.