• Title/Summary/Keyword: Volatile Halogenated organic compounds

Search Result 21, Processing Time 0.026 seconds

Determination of THM(trihalomethane) in Rain by using Solid Phase Micro-Elctraction(SPME) Fiber Assembly (고상 미량 추출 장치(SPME, solid phase micro-extraction device)를 이용한 물 중의 THM(trihalomethane) 분석)

  • 유광식;박상윤
    • Journal of Environmental Science International
    • /
    • v.6 no.3
    • /
    • pp.277-283
    • /
    • 1997
  • SPME deuce was applied to determine the THM in an aqueous solution. The 6 kinds of THM was quantitatively detenuned by using GC-ECD which has the sample eutracted on the SPME fiber from an aqueous solution for 10 min. The THM components were well separated from $CHCl_3$ to the last $CHBr_3$ UHh 13 mons at the condition. 6 kinds of the volatile halogenated organic compounds: $CHCl_3$, $CHBrCl_2$, $CHBrtCl_2$, $CHCl_3$, $C_2Cl$. and $CHBr_3$, showed well defirled calibration graph with good llnearlty from a few ppb level up to several tens of pub concentration. $CHBr_2Cl$ and $C_2C1_4$ were detected from a few samples among the 10 of river samples. CHCl3, however, was detected In 4 sea water samples with the highest of 10 ppd among the pouuted 6 positions. Trace level of $CHBr_2Cl$ and few pub level of $CHBr_3$ were also detected at the other two sample stations. Most of the 13 rain water samples collected from 6 sampling stations were contained ppd level of $CHCl_3$, and also $CHBr_2Cl$, and C_2Cl_4$ were only detected at trace level at a few rain samples among them. We could recognize the fact that our Ut and water enoronment has already been contaminated by certain volatile halogenated organic compounds through this study.

  • PDF

A Correlation Study between the Environmental, Personal Exposures and Biomarkers for Volatile Organic Compounds (대기 중 휘발성유기오염물질의 환경, 개인 및 인체 노출의 상관성 연구)

  • Jo, Seong-Joon;Shin, Dong-Chun;Chung, Yong;Breysse, Patrick N.
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.3
    • /
    • pp.197-205
    • /
    • 2002
  • Volatile organic compounds (VOCs) are an important public health problem throughout the world. Many important questions remain to be addressed in assessing exposure to these compounds. Because they are ubiquitous and highly volatile, special techniques must be applied in the analytical determination of VOCs. Personal exposure measurements are needed to evaluate the relationship between microenvironmental concentrations and actual exposures. It is also important to investigate exposure frequency, duration, and intensity, as well as personal exposure characteristics. In addition to air monitoring, biological monitoring may contribute significantly to risk assessment by allowing estimation of absorbed doses, rather than just the external exposure concentrations, which are evaluated by environmental and personal monitoring. This study was conducted to establish the analytic procedure of VOCs in air, blood, urine and exhaled breath and to evaluate the relationships among these environmental media. The subjects of this study were selected because they are occupationally exposed to high levels of VOCs. Environmental, personal, blood, urine and exhalation samples were collected. Purge & trap, thermal desorber, gas chromatography and mass selective detector were used to analyze the collected samples. Analytical procedures were validated with the“break through test”, 'quot;recovery test for storage and transportation”,“method detection limit test”and“inter-laboratory QA/QC study”. Assessment of halogenated compounds indicted that they were significantly correlated to each other (p value < 0.01). In a similar manner, aromatic compounds were also correlated, except in urine sample. Linear regression was used to evaluate the relationships between personal exposures and environmental concentrations. These relationships for aromatic and halogenated are as follows: Halogen $s_{personal}$ = 3.875+0.068Halogen $s_{environmet}$, ($R^2$= .930) Aromatic $s_{personal}$ = 34217.757-31.266Aromatic $s_{environmet}$, ($R^2$= .821) Multiple regression was used to evaluate the relationship between exposures and various exposure deter-minants including, gender, duration of employment, and smoking history. The results of the regression model-ins for halogens in blood and aromatics in urine are as follows: Halogen $s_{blood}$ = 8.181+0.246Halogen $s_{personal}$+3.975Gender ($R^2$= .925), Aromatic $s_{urine}$ = 249.565+0.135Aromatic $s_{personal}$ -5.651 D.S ($R^2$ = .735), In conclusion, we have established analytic procedures for VOC measurement in biological and environmental samples and have presented data demonstrating relationships between VOCs levels in biological media and environmental samples. Abbreviation GC/MS, Gas Chromatography/Mass Spectrometer; VOCs, Volatile Organic Compounds; OVM, Organic Vapor Monitor; TO, Toxic Organicsapor Monitor; TO, Toxic Organics.

Temporal Characteristics of Volatile Organic Compounds in Newly-Constructed Residential Buildings: Concentration and Source

  • Shin, Seung-Ho;Jo, Wan-Kuen
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.169-176
    • /
    • 2013
  • The present study was designed to examine the concentrations, emission rates, and source characteristics of a variety of volatile organic compounds (VOCs) in 30 newly-constructed apartment buildings by measuring indoor and outdoor VOC concentrations over a 2-year period. For comparison, seven villa-type houses were also surveyed for indoor and outdoor VOC concentrations over a 3-month period. Indoor and outdoor air samples were collected on Tenax-TA adsorbent and analyzed using a gas chromatograph (GC)/mass spectrometer system or a GC/flame ionization detector system coupled to a thermal desorption system. The long-term change in indoor VOC concentrations depended on the type of VOCs. Generally, aromatic (except for naphthalene), aliphatic, and terpene compounds exhibited a gradual deceasing trend over the 2-year follow-up period. However, the indoor concentrations of the six halogenated VOCs did not significantly vary with time changes. Similar to these halogenated VOCs, the indoor naphthalene concentrations did not vary significantly with time changes over the 2-year period. Unlike the halogenated VOCs, the indoor naphthalene concentrations were much higher than the outdoor concentrations. The indoor concentrations of aliphatic and aromatic compounds were higher for the villa-type houses when compared to those of apartment buildings. In addition, four source groups (floor coverings and interior painting, household products, wood paneling and furniture, moth repellents) and three source groups (floor coverings and interior painting, household products, and moth repellents) were considered as potential VOC sources inside apartment buildings for the first- and second-year post-occupancy stages, respectively.

Evaluation of Fugitive Emission Characteristics of Airborne Volatile Organic Compounds from Different Source Categories (발생원 유형에 따른 공기 중 휘발성 유기화합물의 비산배출 특성 평가)

  • 백성옥;김미현;서영교
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.4
    • /
    • pp.363-376
    • /
    • 2003
  • In this study, the fugitive emission characteristics of airborne volatile organic compounds from different source categories were evaluated with respect to the concentrations measured in the vicinity of the sources. A total of 22 different sources were investigated, including gasoline storage and filling stations, painting spray booth, laundry, printing officer, textile industries, and a number of environmental sanitary facilities such as landfill, wastewater treatment and incineration plants. The target VOCs included 83 individual compounds, which were determined by adsorption sampling and thermal desorption coupled with GC/MS analysis. Overall, the aliphatic compounds appeared to be the most abundant class of compounds in terms of their concentrations, followed by aromatic, and halogenated hydrocarbons. As a single compound, however, toluene was the most abundant one, explaining 11% of the total VOC concentrations as an average of all the dataset. Among source categories, petroleum associated sources such as gasoline storage/filling stations, and laundry factory were identified as the most significant sources of aliphatic hydrocarbons, while aromatic VOCs were dominantly emitted from the sources handling organic solvents, such as painting booth, printing offices, and textile dyeing processes. However. there was no apparent pattern in terms of the contributions of eath group to the total VOCs concentrations in environmental sanitary facilities. It was also found that the activated carbon adsorption tower installed for the VOC emission control in some facilities do not show any effective performances, which may result in the increased VOC levels in the ambient atmosphere.

Comparison of Sampling and Analysis Methods for Volatile Organic Compounds in Ambient Air (대기중 휘발성 유기화합물의 채취 및 분석 방법 비교)

  • 나광삼;김용표
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.5
    • /
    • pp.507-518
    • /
    • 1998
  • A field comparison study was carried out to quantify differences among various sampling and analytical methods for volatile organic compounds (VOCs) at a site in Vlsan in June 1997. Air sampling containers (SUMMA canisters) were used by the Korea Institute of Science and Technology (KIST) and adsorption tubes (carbotrap) were used by Yeungnam University (YN Univ.) for sampling ambient air. Duplicate samples obtained by KIST were analyzed by KIST with a GC-MS system for aromatics and halogenated hydrocarbons and by Atm AA with a GC -FID system for C2∼C9 hydrocarbons, respectively. The adsorption tube samples were analyzed by YN Univ. with a GC-FID system for aromatics. VOC levels for the duplicate canister sampls analyzed by KIST and Atm AA were in good agreement. Concentrations of aromatics by the adsroption tube method were generally higher than those by the canister sampling method by factor of 1.5 to 2.0. Differences between the two sampling methods were discussed.

  • PDF

A Photocatalytic Treatment equipment of Volatile Organic Compounds (광촉매를 이용한 휘발성유기화합물의 처리장치)

  • 유재흥;김태관;유진승;김광;김혜경;박윤창;이승호
    • Environmental engineer
    • /
    • s.176
    • /
    • pp.58-63
    • /
    • 2001
  • 여러 환경정화 방법들 중 광촉매를 이용한 처리기술들이 관심을 모으고 있다. 광에 의해 활성을 갖는 여러 촉매들 가운데 이산화티타늄($TiO_2$)을 중심으로 한 연구가 가장 활발히 진행되고 있다. 본 연구는 TiO2를 개질화하여 광활성이 우수한 광촉매를 개발하고 이를 이용한 VOC 처리를 목적으로 하고 있다. VOC 중 할로겐화(halogenated)된 것들의 처리는 매우 어려우며 현재의 소각방식으로는 효과적으로 처리되고 있지 않다.

  • PDF

Characterization of a Membrane Interface for Analysis of Air Samples Using Time-of-flight Mass Spectrometry

  • Jang, Yu-Mi;Oh, Jun-Sik;Park, Chang-Joon;Yang, Sang-Sik;Jung, Kwang-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.10
    • /
    • pp.2791-2796
    • /
    • 2010
  • In the present study, we constructed a membrane inlet assembly for selective permeation of volatile airborne organic compounds for subsequent analysis by time-of-flight mass spectrometry. The time-dependent diffusion of analytes through a $75\;{\mu}m$ thick polydimethylsiloxane membrane was measured by monitoring the ion signal after a step change in the sample concentration. The results fit well to a non-steady-state permeation equation. The diffusion coefficient, response time, and sensitivity were determined experimentally for a range of polar (halogenated) and nonpolar (aromatic) compounds. We found that the response times for several volatile organic compounds were greatly influenced by the alkyl chain length as well as the size of the substituted halogen atoms. The detection limits for benzene, ethylbenzene, and 2-propanol were 0.2 ppm, 0.1 ppm, and 3.0 ppm by volume, respectively, with a linear dynamic range greater than three orders of magnitude. These results indicate that the membrane inlet/time-of-flight mass spectrometry technique will be useful for a wide range of applications, particularly for in situ environmental monitoring.

Volatile Organic Compounds contamination in some urban runoff and groundwater samples in Seoul City (서울시 도로변 빗물과 지하수의 VOCs오염)

  • 이평구;박성원;전치완;신성천
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.3
    • /
    • pp.73-91
    • /
    • 2001
  • compounds (VOCs) were selected for assessment of VOCs contamination in some urban runoff and groundwater samples in Seoul. They included 3 aromatic hydrocarbons, 13 alkyl benzenes, 1 ether, 26 halogenated alkanes, 10 halogenated alkenes, and 9 halogenated aromatics. The levels of VOCs in urban runoff and groundwater were measured for samples collected in March 2000, June 2000 and November 2000 in Seoul City. A total of 78 samples (44 run-off water, 27 groundwater, and 7 samples from 4 urban wastewater treatment plants in Seoul) were collected and analysed by GC-MS with purge and trap. After examination of the runoff, it was concluded that alkyl benzenes and aromatic hydrocarbons were organic compounds which were significantly impacted by traffic flows in Seoul. Of 62 VOCs, only 11 VOCs were not detected in runoff samples, while 14 VOCs were detected in 27 groundwater samples. The toluene content in the runoff was extremely variable from 0.1ppb to 29,310ppb, depending on the different sampling sites. The concentrations of xylene ranged between 0.07ppb and 2970ppb in the runoff. The concentrations ranged from 0.05ppb to 33.0ppb for benzene, 0.05ppb to 960ppb for ethylbenzene, 0.08ppb to 20ppb for trichloromethane (chloroform) , 0.03ppb to 4.30ppb for trichloroethylene(TCE) and 0.1ppb to 50ppb for 1,1,2-trichloroethane. From the preliminary study of groundwater from some wells in Seoul, the most frequently detected VOCs are djchlorornethane(methylene chloride), trichloromethane(chloroform) and toluene. Most of aromatic hydrocarbons, alkyl benzenes and other solvents generally lower than detection limits.

  • PDF

The Characteristics of the Appearance and Health Risks of Volatile Organic Compounds in Industrial (Pohang, Ulsan) and Non-Industrial (Gyeongju) Areas

  • Jung, Jong-Hyeon;Choi, Bong-Wook;Kim, Mi-Hyun;Baek, Sung-Ok;Lee, Gang-Woo;Shon, Byung-Hyun
    • Environmental Analysis Health and Toxicology
    • /
    • v.27
    • /
    • pp.12.1-12.8
    • /
    • 2012
  • Objectives: The aim of this study was to identify the health and environmental risk factors of air contaminants that influence environmental and respiratory diseases in Gyeongju, Pohang and Ulsan in South Korea, with a focus on volatile organic compounds (VOCs). Methods: Samples were collected by instantaneous negative pressure by opening the injection valve in the canister at a fixed height of 1 to 1.5 m. The sample that was condensed in $-150^{\circ}C$ was heated to $180^{\circ}C$ in sample pre-concentration trap using a 6-port switching valve and it was injected to a gas chromatography column. The injection quantity of samples was precisely controlled using an electronic flow controller equipped in the gas chromatography-mass spectrometer. Results: The quantity of the VOC emissions in the industrial area was 1.5 to 2 times higher than that in the non-industrial area. With regards to the aromatic hydrocarbons, toluene was detected at the highest level of 22.01 ppb in Ulsan, and chloroform was the halogenated hydrocarbons with the highest level of 10.19 ppb in Pohang. The emission of toluene was shown to be very important, as it accounted for more than 30% of the total aromatic hydrocarbon concentration. Conclusions: It was considered that benzene in terms of the cancer-causing grade standard, toluene in terms of the emission quantity, and chloroform and styrene in terms of their grades and emission quantities should be selected for priority measurement substances.

Characterization of Volatile Organic Compounds in New Residential Buildings Before Moving-in

  • Shin, Seung-Ho;Jo, Wan-Kuen
    • Journal of Environmental Science International
    • /
    • v.21 no.1
    • /
    • pp.11-21
    • /
    • 2012
  • This study investigated the characteristics of selected volatile organic compounds(VOCs) in newly-finished residential buildings, before the occupants moved in. This investigation was carried out by measuring the indoor and outdoor concentrations of selected VOCs before the occupants moved in and by utilizing an indoor mass balance model. Among 25 target VOCs, five aromatics(benzene, ethyl benzene, toluene, m,p-xylene, and o-xylene) were detected in all samples of both indoor and outdoor air. Toluene was most abundant VOC in the indoor air of new apartments, with a median value of 168 mg $m^{-3}$. Unlike other VOCs, halogenated compounds would not be significantly emitted from building materials. The indoor air concentrations of all selected VOCs, except for 1,3,5-trimethyl benzene, exhibited significant correlations each other, while for outdoor air concentrations, five aromatics only were significantly correlated between them. The emission rate of toluene was higher for the current study(median value, 76.8 mg $m^{-2}\;h^{-1}$) than for a previous study, while the emission rates of limonene, a-pinene and b-pinene(geometric means of 2.4, 13.8 and 9.6 mg $m^{-2}\;h^{-1}$, respectively) were lower and the emission rates of m,p-xylene and 2-butanone(geometric means of 10.9 and 21.3 mg $m^{-2}\;h^{-1}$, respectively) were similar. Although there were a few exceptions, the emission strengths are likely proportional to indoor temperature, and appear to reversely proportional to air exchange rate.