• Title/Summary/Keyword: Viscosity method

Search Result 1,132, Processing Time 0.031 seconds

Comparison of the Viscosity of Ceramic Slurries using a Rotational Rheometer and a Vibrational Viscometer (회전형 레오미터와 진동형 점도계를 이용한 세라믹 슬러리의 점도 비교)

  • Ji, Hye;Lim, Hyung Mi;Chang, Young-Wook;Lee, Heesoo
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.6
    • /
    • pp.542-548
    • /
    • 2012
  • The viscosity of a ceramic slurry depends on the slurry concentration, particle shape and size, hydrodynamic interactions, temperature, shear rate, pre-treatment condition and the method of measurement with the selected equipment. Representative ceramic slurries with low to high viscosity levels are selected from colloidal silica, barium titanate slurry and glass frit paste. Rotational rheometers and vibrational viscometers are used to compare the measured viscosity for various ceramic slurries. The rotational rheometer measured the viscosity according to the change of the shear rate or the rotational speed. On the other hand, the vibrational viscometer measured one point of the viscosity in a fixed vibrational mode. The rotational rheometer allows the measurement of the viscosity of a ceramic paste with a viscosity higher than 100,000 cP, while the vibrational viscometer provides an easy and quick method to measure the viscosity without deformation of the ceramic slurry due to the measurement method. It is necessary to select suitable equipment with which to measure the viscosity depending on the purpose of the measurement.

The Elongation Method for the Measuring Surface Tension of High Viscosity Printing Ink (인장법에 의한 고점도 잉크의 표면장력 측정법)

  • Ha, Young-Baeck;Youn, Jong-Tae;Koo, Chul-Whoi
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.21 no.2
    • /
    • pp.89-100
    • /
    • 2003
  • We have reviewed the method for surface tension of printing inks. Most of the methods fir for the low viscosity inks and solvents for inks. However, the inks for the offset lithography and intaglio should have high viscosity and high tack. The elongation of the ink filaments has more effect on the measuring surface tension than the energy of the surface molecules. In this paper, we propose the elongation method to estimate the surface tension of high viscosity printing inks. Even though we could measure the surface tension for low viscosity inks such as gravure and screen, elongation method could more useful to estimate the surface tension of lithography and intaglio inks than any other methods.

  • PDF

Microfluidic Method for Measurement of Blood Viscosity based on Micro PIV (Micro PIV 를 기반한 혈액 점도 측정 기법)

  • Hong, Hyeonji;Jung, Mirim;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.15 no.3
    • /
    • pp.14-19
    • /
    • 2017
  • Increase of blood viscosity significantly changes the flow resistance and wall shear stress which are related with cardiovascular diseases. For measurement of blood viscosity, microfluidic method has proposed by monitoring pressure between sample and reference flows in the downstream of a microchannel with two inlets. However, it is difficult to apply this method to unknown flow conditions. To measure blood viscosity under unknown flow conditions, a microfluidic method based on micro particle image velocimetry(PIV) is proposed in this study. Flow rate in the microchannel was estimated by assuming velocity profiles represent mean value along channel depth. To demonstrate the measurement accuracy of flow rate, the flow rates measured at the upstream and downstream of a T-shaped microchannel were compared with injection flow rate. The present results indicate that blood viscosity could be reasonably estimated according to shear rate by measuring the interfacial width and flow rate of blood flow. This method would be useful for understanding the effects of hemorheological features on the cardiovascular diseases.

CONVERGENCE THEOREMS ON VISCOSITY APPROXIMATION METHODS FOR FINITE NONEXPANSIVE MAPPINGS IN BANACH SPACES

  • Jung, Jong-Soo
    • The Pure and Applied Mathematics
    • /
    • v.16 no.1
    • /
    • pp.85-98
    • /
    • 2009
  • Strong convergence theorems on viscosity approximation methods for finite nonexpansive mappings are established in Banach spaces. The main theorem generalize the corresponding result of Kim and Xu [10] to the viscosity approximation method for finite nonexpansive mappings in a reflexive Banach space having a uniformly Gateaux differentiable norm. Our results also improve the corresponding results of [7, 8, 19, 20].

  • PDF

Consideration of Spindle Immersion Depth on Determining the Viscosity of Glass Melts by Rotating Cylinder Method

  • Kim, Young-Jin;Kim, Ki-Dong;Lee, Seung-Beun;Hwang, Song-Hee
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.4
    • /
    • pp.344-347
    • /
    • 2004
  • The influence of spindle immersion depth on the determination of glass melt viscosity was examined in rotating cylinder method. The exact adjustment of spindle immersion depth into soda lime silicate standard glass melts could be peformed by self-constructed electric system. The results showed a slight dependence of viscosity value on the immersion depth change of spindle shaft. The viscosity error per unit length of spindle was 0.4%/mm under the present cylinder dimension.

Blood Viscosity Measurements Using a Pressure-Scanning Capillary Viscometer

  • Sehyun Shin;Keum, Do-Young;Ku, Yun-Hee
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.12
    • /
    • pp.1719-1724
    • /
    • 2002
  • A previously designed capillary viscometer with measuring differential pressure was modified to measure the viscosity of non-Newtonian fluids including unadulterated blood continuously over numerous shear rates in a single measurement. Because of unavoidable experimental noise and a limited number of data, the previous capillary viscometer experienced an inaccuracy and could not directly determine a viscosity without an iterative calculation. However, in the present measurement there are numerous data available near the point of interest so that the numeric value of the derivative, d(In Q)/d(In Q$\sub$w/), is no longer sensitive to the method of differentiation. In addition, relatively low and wide shear rate viscosity measurements were possible because of the present precision pressure-scanning method with respect to time. For aqueous polymer solutions, excellent agreement was found between the results from the pressure-scanning capillary viscometer and those from a commercially available rotating viscometer. In addition, the pressure-scanning capillary viscometer measured the viscosity of unadulterated whole blood without adding any anticoagulants.

The Influence of Engine Operating Conditions and Lubricants on Oil Film Thickness of Engine Connecting Rod Bearing (커넥팅로드 베어링의 유막두께에 미치는 기관 운전조건 및 윤활유의 영향)

  • Lee, D.H.;Chang, B.J.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.5
    • /
    • pp.1-10
    • /
    • 1994
  • By applying of total electric capacitance method on engine connecting rod bearing during engine operating, the influence of engine operating conditions and lubricants on bearing oil film thickness was investigated. Minimum oil film thickness increases with kinematic viscosity, but as increasing of viscosity, the increasing ratio of film thickness is reduced. Also minimum oil film thickness increases with engine speed but there is a limit. Above this limit, film thickness decreases in opposition because of crankshaft inertia. As increasing of engine torque and oil temperature, munimum oil film thickness decreases linearly. For non-Newtonian oils, the correlation between $100{\circ}C$ kinematic viscosity and munimum oil film thickness is very poor.

  • PDF

Viscosity Characteristics of Waste Cooking Oil with Ultrasonic Energy Irradiation

  • Kim, Tae Han;Han, Jung Keun
    • Journal of Biosystems Engineering
    • /
    • v.37 no.6
    • /
    • pp.429-433
    • /
    • 2012
  • Purpose: While rapeseed oil, soy bean oil, palm oil and waste cooking oil are being used for biodiesel, the viscosity of them should be lowered for fuel. The most widely used method of decreasing the viscosity of vegetable oil is to convert the vegetable oil into fatty acid methyl ester but is too expensive. This experiment uses ultrasonic energy, instead of converting the vegetable oil into fatty acid methyl ester, to lower the viscosity of the waste cooking oil. Methods: For irradiation treatment, the sample in a beaker was irradiated with ultrasonic energy and the viscosity and temperature were measured with a viscometer. For heating treatment, the sample in a beaker was heated and the viscosity and temperature were measured with a viscometer. Kinematic viscosity was calculated by dividing absolute viscosity with density. Results: The kinematic viscosity of waste cooking oil and cooking oil are up to ten times as high as that of light oil at room temperature. However, the difference of two types of oil decreased by four times as the temperature increased over $83^{\circ}C$. When the viscosity by the treatment of ultrasonic energy irradiation was compared to one by the heating treatment to the waste cooking oil, the viscosity by the treatment of ultrasonic energy irradiation was lower by maximum of 22% and minimum of 12%, than one by the heating treatment. Conclusions: Ultrasonic energy irradiation lowered the viscosity more than the heating treatment did, and ultrasonic energy irradiation has an enormous effect on fuel reforming.

The Elongation Method for the Measuring Surface Tension of High Viscosity Printing Ink (II) (인장법에 의한 고점도 잉크의 표면장력 측정법 (II))

  • Ha, Young-Baeck;Youn, Jong-Tae;Koo, Chul-Whoi
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.22 no.2
    • /
    • pp.23-36
    • /
    • 2004
  • The surface tension method has been possible only for the low viscosity materials. However, the inks for the off-set lithography and intaglio should have high viscosity and high tack. In this paper, we propose the elongation method to estimate the surface tension of high viscosity printing inks. The elongation method could be more useful to estimate the surface tension and shown in this research, it is possible to calculate the surface tension of high viscoxity ink without diluting the sample.

  • PDF