• Title/Summary/Keyword: Virtual planning

Search Result 373, Processing Time 0.026 seconds

A Study on the Operation Model of Continuing Education for Academic Librarians (대학도서관 사서직을 위한 계속교육 운영모형 연구)

  • Hwang, Ok-Gyung;Oh, Se-Hoon
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.17 no.1
    • /
    • pp.249-263
    • /
    • 2006
  • The purpose of the study was to investigate the continuing education model desired by the academic librarians in the present digital environment. For this purpose the study undertook a questionnaire survey of academic librarians in Korea. As a result it was shown that 61.4% of the librarians participated more than once(average 2.6 times) in the continuing education program during the last one year. The most preferred program type was one week or 2-3 days workshop. The theme of the program was regarded the most important factor for the activation of the continuing education. and the preferred theme of the program was user instruction. information retrieval. electronic licensing. planning and strategy, library marketing, virtual reference service etc.

Development of Teaching and Learning Process Plans Based on the Use of the Metaverse ZEP Platform in Practical Arts (Technology & Home Economics) Focusing on the "Family Life" Unit (실과(기술·가정) 교과 '가족' 영역 메타버스 ZEP 플랫폼 기반 교수·학습 과정안 개발)

  • Eun Mi Ko;Sung Sook Kim;Hyoung Sun Kim;Yeon Jeong Kim;Jung Hyun Chae
    • Human Ecology Research
    • /
    • v.61 no.4
    • /
    • pp.543-563
    • /
    • 2023
  • The purpose of this study is to design and develop a Metaverse ZEP platform-based teaching and learning process plan by selecting learning topics that are commonly dealt with among the core concepts of the "family" area of practical (technical and home) subjects. To this end, a teaching and learning process plan was developed through planning, Metaverse platform design, expert review, and revision stages. The Metaverse ZEP "Open Class Day" platform, a virtual learning space, was created and developed to further utilize EduTech programs, such as Padlet, Mentimeter, Jamboard, Miricanvas, and Spatial. The teaching and learning process plan developed in this study consists of a total of seven sessions, including approaching EduTech, Changing Families, Exploring Our Family, and Counseling Centers 1, 2, and 3. Among them, Geumji Counseling Center 1, 2, and 3 was designed as a class in which parents and children participate together in open classes using the ZEP platform. This platform can be used as part of parent classes as well as to encourage online participation in the open classes held periodically at each individual school. In terms of the content validity ratio (CVR) of the developed teaching and learning process verified through five experts, 12 out of 15 questions had a CVR of 1, while the remaining three questions had a CVR of 0.6. The three questions with lower validity were revised and supplemented.

A Study on Intracavitary Therapy in Cervix Cancer Using Needle for Interstitial Therapy (조직 내 삽입용 바늘을 이용한 자궁경부암의 강내치료에 관한 연구)

  • Cho, Jung-Keun;Jung, Hong-Ryang;Lim, Cheong-Hwan;Kim, Jeong-Koo;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.83-92
    • /
    • 2006
  • Based on the data of cervical cancer patients who were treated by the radiotherapy with concurrent chemotherapy at the radiation oncology department of National Cancer Center from January 2002 to February 2003, we have studied the method recommended by ICRU 38 to maximize the prescription dose to the planing target volume (PTV) with minimizing the dose to surrounding normal organs. Clinical stage of the patients are 1 patient for stage IB, 3 patients for IIA, 19 patients for IIB, 3 patients for IIIA, 3 patients for IIIB and 1 patient for IV. All patients took the MRI before treatment and the maximum size of the gross tumor volume were under 4cm for 17 patients and from 4 cm to 6 cm for 12 patients and above 6 cm for 1 patient. The results show that while the irradiated volume can be reduced with optimized dose distribution using PTV treatment planning (p<0.0001) when the remained tumor size is small, the surrounding normal organs will receive unnecessarily large dose when the irradiated tumor volume is relatively large. This is because there is some limitation in controling the intensity of radiation in Fletcher Williamson Applicator. To overcome the limit of applicator and to achieve the optimal dose distribution, we have virtually applied 4 needles with Fletcher Williamson Applicator for 10 patients who have relatively large tumor and studied the change in dose distribution before and after application. The results show that this new virtual treatment plan reduces the volume covered by 100 % isodose (p=0.0608, p=0.0607) and reduces the dose of normal organs (p=0.0162, p=0.008). This evidence suggest that this method is superior than the currently used method such as PTV treatment and ICRU treatment.

  • PDF

Analysis on the Effect of Field Width in the Delineation of Planning Target Volume for TomoTherapy (토모테라피에서 계획용표적체적 설정 시 필드 폭 영향 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mee-Sun;Jung, Jae-Uk
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.323-331
    • /
    • 2010
  • The Hi-Art system for TomoTherapy allows only three (1.0 cm, 2.5 cm, 5.0 cm) field widths and this can produce different dose distribution around the end of PTV (Planning target volume) in the direction of jaw movement. In this study, we investigated the effect of field width on the dose difference around the PTV using DQA (Delivery quality assurance) phantom and real clinical patient cases. In the analysis with DQA phantom, the calculated dose and irradiated films showed that the more dose was widely spreaded out in the end region of PTV as increase of field width. The 2.5 cm field width showed a 1.6 cm wider dose profile and the 5.0 cm field width showed a 4.2 cm wider dose profile compared with the 1.0 cm field width in the region of 50% of maximum dose. The analysis with four patient cases also showed the similar results with the DQA phantom which means that more dose was irradiated around the superior and inferior end of PTV as an increase of field width. The 5.0 cm field width produced the remarkable high dose distribution around the end region of PTV and we could evaluate the effect quantitatively with the calculation of DVH (Dose volume histogram) of the virtual PTVs which were delineated around the end of PTV in the direction of jaw variation. From these results, we could verify that the margin for PTV in the direction of table movement should be reduced compared with the conventional margin for PTV when the large field such as 5.0 cm was used in TomoTherapy.

Convolution-Superposition Based IMRT Plan Study for the PTV Containing the Air Region: A Prostate Cancer Case (Convolution-Superposition 알고리즘을 이용한 치료계획시스템에서 공기가 포함된 표적체적에 대한 IMRT 플랜: 전립선 케이스)

  • Kang, Sei-Kwon;Yoon, Jai-Woong;Park, Soah;Hwang, Taejin;Cheong, Kwang-Ho;Han, Taejin;Kim, Haeyoung;Lee, Me-Yeon;Kim, Kyoung Ju;Bae, Hoonsik
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.271-277
    • /
    • 2013
  • In prostate IMRT planning, the planning target volume (PTV), extended from a clinical target volume (CTV), often contains an overlap air volume from the rectum, which poses a problem inoptimization and prescription. This study was aimed to establish a planning method for such a case. There can be three options in which volume should be considered the target during optimization process; PTV including the air volume of air density ('airOpt'), PTV including the air volume of density value one, mimicking the tissue material ('density1Opt'), and PTV excluding the air volume ('noAirOpt'). Using 10 MV photon beams, seven field IMRT plans for each target were created with the same parameter condition. For these three cases, DVHs for the PTV, bladder and the rectum were compared. Also, the dose coverage for the CTV and the shifted CTV were evaluated in which the shifted CTV was a copied and translated virtual CTV toward the rectum inside the PTV, thus occupying the initial position of the overlap air volume, simulating the worst condition for the dose coverage in the target. Among the three options, only density1Opt plan gave clinically acceptable result in terms of target coverage and maximum dose. The airOpt plan gave exceedingly higher dose and excessive dose coverage for the target volume whereas noAirOpt plan gave underdose for the shifted CTV. Therefore, for prostate IMRT plan, having an air region in the PTV, density modification of the included air to the value of one, is suggested, prior to optimization and prescription for the PTV. This idea can be equally applied to any cases including the head and neck cancer with the PTV having the overlapped air region. Further study is being under process.

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

Three Dimensional Target Volume Reconstruction from Multiple Projection Images (다중투사영상을 이용한 표적체적의 3차원 재구성)

  • 정광호;진호상;이형구;최보영;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.167-174
    • /
    • 2003
  • In the radiation treatment planning (RTP) process, especially for stereotactic radiosurgery (SRS), knowing the exact volume and shape and the precise position of a lesion is very important. Sometimes X-ray projection images, such as angiograms, become the best choice for lesion identification. However, while the exact target position can be acquired by bi-projection images, 3D target reconstruction from bi-projection images is considered to be impossible. The aim of this study was to reconstruct the 3D target volume from multiple projection images. It was assumed that we knew the exact target position in advance, and all processes were performed in Target Coordinates, where the origin was the center of the target. We used six projections: two projections were used to make a Reconstruction Box and four projections were for image acquisition. The Reconstruction Box was made up of voxels of 3D matrices. Projection images were transformed into 3D in this virtual box using a geometric back-projection method. The resolution and the accuracy of the reconstructed target volume were dependent on the target size. An algorithm was applied to an ellipsoid model and a horseshoe-shaped model. Projection images were created geometrically using C program language, and reconstruction was also performed using C program language and Matlab ver. 6(The Mathwork Inc., USA). For the ellipsoid model, the reconstructed volume was slightly overestimated, but the target shape and position proved to be correct. For the horseshoe-shaped model, reconstructed volume was somewhat different from the original target model, but there was a considerable improvement in determining the target volume.

  • PDF

Causes of Cyber Sickness of VR Contents: An Experimental Study on the Viewpoint and Movement (VR 콘텐츠의 사이버 멀미 유발 요인: 시점과 움직임의 효과에 대한 실험 연구)

  • Jung, Ji-Young;Cho, Kwang-Su;Choi, Jinhae;Choi, Junho
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.4
    • /
    • pp.200-208
    • /
    • 2017
  • Despite a rapid market growth in VR, cyber sickness has become the most serious problem in terms of user experience. The aim of this study is to verify whether there are differences in user's perception of cyber sickness by the point-of-view and the movement in VR contents. An experimental testing of game playing with VR headset was conducted on the effects of two conditions: first-person and third-person views in the point-of-view condition, and yaw - pitch rotations in the head movement condition. The results showed that cyber sickness worsened in the first-person point-of-view and in the yaw rotation movement. Point-of-view and movement had main effects on the cyber sickness, but an interaction effect between point-of-view and movement was not found. Based on the findings, along with reducing VR sickness, we proposed practical implications for VR contents planning for building balanced VR user experience. Positive VR experience can be reinforced through visual design, multi-modal interface design, and experience marketing for the optimal level of contents immersion. A future research was suggested on the roll rotation for diverse content genre development.

An Empirical Study on Future New Technology in Defense Unmanned Robot (국방 무인로봇 분야 미래 신기술에 관한 실증연구)

  • Kim, DoeHun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.611-616
    • /
    • 2018
  • With the recent increase in awareness of the diversification of patterns of warfare and security, technological evolution is occurring in the field of autonomous defense robots. As defense science and technology develops with the development of the concept of military utilization focusing on human lives and economic operation, the importance of autonomous robots in the effect-oriented future battlefield is increasing. The major developed countries have developed core technologies, investment strategies, priorities, data securing strategies and infrastructure development related to the field of autonomous defense robots, and research activities such as technology planning and policy strategy for autonomous defense robots in Korea have already begun. In addition, the field of autonomous defense robots encompasses technologies that represent the fourth industrial revolution, such as artificial intelligence, big data, and virtual reality, and so the expectations for this future area of technology are very high. It is difficult to predict the path of technological development due to the increase in the demand for new rather than existing technology. Moreover, the selection and concentration of strategic R&D is required due to resource constraints. It is thought that a preemptive response is needed. This study attempts to derive 6 new technologies that will shape the future of autonomous defense robots and to obtain meaningful results through an empirical study.

Evaluation of the Standardized Curriculum Module and Integrated Program for Social-Environmental Education (사회환경 교육과정의 표준화 모형 및 통합 프로그램의 평가)

  • Lee, Sook-Im;Kang, Myoung-Hee;Nam, Sang-Jun;Park, Suk-Soon;Sung, Hyo-Hyun;Choi, Don-Hyung;Hur, Myung
    • Hwankyungkyoyuk
    • /
    • v.14 no.2
    • /
    • pp.76-94
    • /
    • 2001
  • Promoting positive values, attitudes, participation and personal actions on the basis of the acquisition of one's knowledge and skills is emphasized on teaching environmental education. To complete this purpose of environmental education, it is necessary not only to use various and practical educational resources, but also to develop information system, with multimedia and internet, which are effective for learning. This research attempts to assess the consistency of planning, organization and operation of integrated program for social environmental education which was developed for the necessities mentioned above. We surveyed about the accuracy of contents, usefulness, convenience and easiness of Integrated program for social environmental education. Also, we used a questionnaire to clarify the values and attitudes of respondents after they took environmental education. Then, technically, descriptive statistical method has been used to analyze the results of these surveys. Finally, we conduct an examination of the distribution of chi-square to verify the relationship between the learner's experience of using computer and one's concern about environmental issues. The results of this program, developed by research team, can be assessed by following five basic elements: usefulness, practicality, appropriation, efficiency and effectiveness. More than 90% of respondents said that this program is convenient and easy to loam. Also, more than 85% of whole respondents identified that after teaming this program they recognized more clearly what the main contents of environmental education are. In addition, we got positive response from 93% of respondents that they could understand environmental problems. On the other hand, values and attitudes of respondents have not improved a lot after the environmental education compared with the remarkable change in their recognition and understanding of environmental issues; only 34% of respondents responded that they changed their life style for making better environment after teaming this program. But it is clear that they understand much better about the environmental policy after they are educated. Developed by using information system, this integrated program for social environmental education may get different results according to a respondent's experience of using computer. Therefore, the more a respondent got a chance to use computer for a long period of time, the more he/she gave positive evaluation on the convenience and easiness of this program. However, there was no certain relationship between the frequence of using computer and one's understanding of environmental issues. Futhermore, a person who has constant concerns about environmental problems showed more positive attitudes against the understanding of environmental education. This integrated program for social environmental education, characterized by integrated, specialized and efficient educational system, can also be used as a curriculum or teaching materials for environmental education for adults; especially, it would be appropriate for teaching learners at all levels, who have different personal characteristics, to let them acquire virtual education by using information system.

  • PDF