• 제목/요약/키워드: Vibration velocity

검색결과 1,406건 처리시간 0.025초

근접장 발파진동에서 진동속도와 진동레벨의 비교 (The Vibration Velocity and Vibration Level of Near-field Blasting Vibration in an Urban Blasting Site)

  • 이연수;장서일
    • 한국소음진동공학회논문집
    • /
    • 제15권8호
    • /
    • pp.918-923
    • /
    • 2005
  • The vibration level (dB(V)) and vibration velocity (cm/sec) on the ground and buildings due to the differences of the measuring sites from the blasting source was investigated. To compare with vibration level and vibration velocity theirs magnitude was not surely directly proportional and vibration velocity 0.1 cm/sec was $45\~50$ dB(V). The difference between the measured vibration level and the calculated vibration level by Ejima's equation using vibration velocity PVS(peak vector sum) showed $21.0\~30.9$ dB(V) on the ground, $15.3\~23.6$ dB(V) on the apartment, respectively. And the correlation of vibration velocity and nitration level at the measuring sites of lower altitude showed higher than that of higher altitude.

발파진동 예측방법에 관한 연구 (A Study on the Prediction Method of Blasting Vibration)

  • 이연수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.361-365
    • /
    • 2006
  • In order to predict method of blasting vibration in ground and it's resident located around blasting field in urban area, blasting vibration characteristics were measured the vibration velocity(cm/sec), vibration acceleration($cm/sec^2$), vibration acceleration level(dB) and vibration level(dB(V)). The charged powder were used to 1.25kg and measuring sites were 25 points front 4m to 90m at the ground. The correlation of vibration velocity, vibration acceleration, vibration acceleration level and vibration level by square root scaled distance and cube root scaled distance were investigated. The correlation of PPV(peak particle velocity) velocity by SRSD(square root scaled distance) and CRSD(cube root scaled distance) was 0.85 and 0.86 and the correlation of PVS(peak vector sum) velocity by SRSD and CRSD was 0.82. Also vibration acceleration, vibration acceleration level and vibration level by SRSD and CRSD was 0.61, 0.62 and 0.82, respectively. As results, the vibration velocity and vibration level(dB(V)) was showed good correlation, but the vibration acceleration and vibration acceleration level was not showed good correlation.

  • PDF

근접장 발파진동에서 진동속도와 진동레벨 (The Vibration Velocity and Vibration Level of Near-field Blasting Vibration in an Urban Blasting Site)

  • 이연수;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.766-771
    • /
    • 2005
  • To compare blasting vibration at blasting construction field in urban area, the vibration level (dB(V)) and vibration velocity (cm/sec) on the ground and the structure of buildings due to the differences of the measuring sites from the blasting source is investigated and the difference between the measured vertical vibration level and the calculated vibration level by using vibration velocity PVS and the correlation between vibration velocity and vibration level and is studied in the thesis.

  • PDF

도로 하부 통과 배관의 주행 하중 속도에 따른 진동 특성 (Dynamic Characteristics of Buried Pipeline under Vibration Velocity of Vehicle Loads)

  • 원종화;선진선;유한규;김문겸
    • 한국가스학회지
    • /
    • 제12권1호
    • /
    • pp.13-18
    • /
    • 2008
  • 지진 및 외부 진동에 의하여 구조물에 발생하게 되는 진동량은 진동 속도와 피해규모가 비례하는 관계에 있음을 고려하여 일반적으로 진동속도로 나타내어진다. 본 연구에서는 진동 속도 기반의 구조물 진동기준을 검토하고, 이를 고려하여 도로 하부 매설 가스 강관의 안정성 평가를 수행하였다. 가스공사 주사용 배관인 762 mm API 5L Gr. X65 강관을 해석 대상 배관으로 선정하였으며 도로설계기준에 의하여 지반 매설 조건 및 DB-24 하중을 다양한 속도에 대한 시간 함수로 고려하여 재하하였다. 진동속도는 차량 진행 속도 80 km/h까지 증가하다가 이후 감소하는 경향을 보였으며, 차량 진행 속도 80 km/h에서 0.034 cm/s의 진동 속도를 보임으로서 진동 기준 대비 매우 작은 값임을 확인하였다. 또한 감쇄법칙을 적용하여 진행파의 속도를 분석한 결과, 차량 진행 속도 80 km/h에서 가장 작은 속도를 나타내었다.

  • PDF

풍차형 초음파 전동기 고정자의 공전 및 전동 속도 특성 (Resonance & Vibration Velocity Characteristics of the Wind-mill type Stator of Ultrasonic Motor)

  • 박만주;김영균;김진수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.231-234
    • /
    • 1998
  • In this study, the wind-mill type ultrasonic motor was fabricated, and then resonant frequency and vibration velocity characteristics of the stator were measured. Brass metal was pressed with umbrella-type using metal mold, then slot of 4 kind was processed in each of thickness. Among sixteen's stators, resonant frequency on vibration velocity was decreased remarkably in stator of higher resonant point, but resonant frequency on vibration velocity wasn't almost changed at lower resonant point of stator. The thickener thickness of elastic body, vibration velocity was decreased. The more slot of elastic body, vibration velocity was increased Applied voltage was changed from 10$V_{max}$ to 100$V_{max}$. Maximum vibration velocity value was 2.0[m/s].

  • PDF

지중 매설 가스 배관의 열차 주행 속도에 따른 진동 속도 특성 (Vibration Velocity Response of Buried Gas Pipelines according to Train Speed)

  • 김미승;선진선;김건;김문겸
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.561-566
    • /
    • 2008
  • Recently, because of development of the high speed train technology, the vibration loads by train is significantly increased ever than before. This buried gas pipelines are exposed to both repeated impact loads, and, moreover, they have been influencing by vibration loads than pipeline which is not located under vehicle loads. The vibration characteristic of pipeline is examined by dynamic analysis, and variable is only train speed. Since an effect of magnitude of vibration loads is more critical than cover depth, as increasing the train speed, the vibration speed of buried pipelines is also increased. The slope of vibration velocity is changed by attenuation of wave, at train speed, 300 km/h. From the analysis results, the vibration velocity of pipelines is satisfied with the vibration velocity criteria which are established by Korea Gas Corporation. The results present operation condition of pipelines under rail loads has fully sound integrity based on KOGAS specification.

  • PDF

발파진동속도와 진동레벨과의 관계식 연구 (A Study on the Related Equation of the Blast Vibration Velocity and the Vibration Level)

  • 김일중;기경철;조영동
    • 화약ㆍ발파
    • /
    • 제27권1호
    • /
    • pp.79-87
    • /
    • 2009
  • 발파진동속도(PVS, PPV, $V_V$)와 진동레벨과의 관계식을 산출하기 위해서 동일한 위치에서 동시에 측정한 진동속도와 진동레벨의 자료를 회귀분석 하였다. 회귀분석결과 발파진동속도와 진동레벨과의 상관관계는 좋았다. 이 연구결과 진동레벨과 진동속도와의 관계식들은 환경진동의 평가 및 관리에 유용하게 적용할 수 있을 것으로 판단된다.

발전소 주변압기 운전중 진동 기준치 설정에 관한 연구

  • 이욱륜;이준신
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.587-592
    • /
    • 2005
  • Main transformer's integrity assessment in nuclear power plant is estimated by the electrical test of electrical core and wire and the chemical analysis of insulating oil. Mechanical test or analysis has not been so far. So this study makes it with the vibration velocity rating. The vibration velocity rating in main transformer which is based on the real data of vibration velocity measurement under operating and other machinery vibration code such as ISO code is renewed.

  • PDF

가스 파이프라인의 차량진동 응답 예측 (A Response Estimation for Vehicle Vibration of Gas Pipeline)

  • 박선준;박연수;강성후
    • 한국소음진동공학회논문집
    • /
    • 제14권1호
    • /
    • pp.40-49
    • /
    • 2004
  • In this paper, vibration response of aerial gas pipeline due to vehicle loads was quantitatively estimated through experiment and analysis in open cut construction site. The vehicle vibration of various construction machines causes serious effect to the aerial gas pipeline. The new vibration prediction equations presented in this study can estimate the vibration velocity response of the aerial gas pipeline. In the nitration prediction equations, the vehicle′s weight and traveling velocity, which are the sources of vibration, are combined into the term called, "scaled weight" Methods to reduce vibration were proposed in case the vibration velocity response of the gas pipeline exceeded the vibration criterion, using the vibration prediction equations presented in this study. One was to limit the vehicle′s traveling velocity and the other to install the isolation equipment. Both methods can be estimated quantitatively.

도심지 발파공사장의 발파진동 특성 (The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area)

  • 이연수;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.521-526
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, Z(perpendicularity) axis was the highest value in vibration level, but vertical axis was the highest value at 25m point and longitudinal axis was the highest value at 50m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, 2 axis was the highest value in vibration level, but in vibration velocity transverse axis was the highest value at ground, was vertical axis at 1st floor, was longitudinal axis at 3rd floor and was vertical and longitudinal axis at 5th floor. The vibration level and the vibration velocity of 50m point showed higher correlation value than 25m point at the ground, but those of 25m point showed higher correlation value than 50m point at the apartment.

  • PDF