• Title/Summary/Keyword: Vibration generators

Search Result 82, Processing Time 0.031 seconds

The Effect of TiN and CrN Coatings on the Fretting Wear of Tubes against Supports in a Nuclear Steam Generators

  • Park, Dong-Shin;Park, Jung-Min;Kim, Jin-Seon;Lee, Young-Ze
    • KSTLE International Journal
    • /
    • v.10 no.1_2
    • /
    • pp.33-36
    • /
    • 2009
  • The nuclear steam generator is composed of a bundle of tubes. The length of these tubes is very long, but their diameter is small. Fluid exists inside of the steam generator and its flow causes vibration, therefore these tubes are supported by anti-vibration bars. The wear damage due to the vibration is known as fretting wear, which should be minimized to ensure the safety of the plants. Research needs to be done about decreasing the amount of fretting wear. Hard coatings have proven to be very effective in reducing the amount of wear. The commercial coatings of TiN and CrN have excellent wear resistance and are used to protect the Inconel tube from fretting wear. The tube-on-flat type tester was used for conducting the fretting wear tests. It was found that the wear amounts of the coated tubes decreased depending on the coating thickness. CrN was found to be very effective in reducing the wear, while the wear amounts were dependent on the coating thickness in the case of TiN and a thick coating of TiN was very effective on wear resistance.

The Application Analysis of Power System Stabilizer in Hydraulic power plant (전력계통안정화장치(PSS) 수력발전소 적용분석)

  • Ok, Yeon-Ho;Lim, Jae-Il;Park, Ji-Kun;Kwak, Won-Ku;Lee, Kwang-Yeon
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.63-65
    • /
    • 2007
  • Recently with increase consumption of electric power, the scale of the electric system becomes bigger and complex. Then, it is increasing the hardship in the operation of electric system and the continuance of stability. Especially, as the differences between demand and supply in electric power keeping low frequency oscillating attenuation from electric power have been very important in the continuance part of stability. The more control time of electricity system is getting faster with digitalization the more stability of electricity system is getting worse. As solutions of these problems, by establishing Power System Stabilizing Controller putting PSS output signal and putting damping to vibration of the rotor at generators's AVR in area where is oscillated, We are willing to contribute the electricity system by holding in generator output vibration.

  • PDF

Development of high performance intake silencer using swirling flow for household oxygen generators (가정용 산소발생기를 위한 스월링 유동을 이용한 고성능 흡기 소음기 개발)

  • Kim, Seong-hun;Lee, Gwang-se;Choi, Yong-bok;Cheong, Cheolung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.581-587
    • /
    • 2014
  • Intake silencers of high performance and with less pressure drop are developed for a household oxygen generator. First, the acoustic power of the target oxygen generator are experimentally evaluated according to ISO code. Then, the transmission loss of and the flow characteristics inside the existing intake silencer are predicted and analyzed. On a basis of these results, two intake silencers are proposed, which are designed to induce the swirling flow inside the intake silencer and thus to reduce the flow loss. The predicted TL and the pressure drop for these two new silencers are compared to the existing one, which shows that the proposed ones have higher TLs as well as less pressure drop. The reason for these improvements are explained by investigating the flow characteristics of the new silencers in detail.

  • PDF

A SIMPLIFIED METHOD TO PREDICT FRETTING-WEAR DAMAGE IN DOUBLE $90^{\circ}$ U-BEND TUBES

  • Choi, Seog-Nam;Yoon, Ki-Seok;Choi, Taek-Sang
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.616-621
    • /
    • 2003
  • Fluid-elastic instability is believed to be a cause of the large-amplitude vibration and resulting rapid wear of heat exchanger tubes when the flow velocity exceeds a critical value. For sub-critical flow velocities, the random turbulence excitation is the main mechanism to be considered in predicting the long-term wear of steam generator tubes. Since flow-induced interactions of the tubes with tube supports in the sub-critical flow velocity can cause a localized tube wear, tube movement in the clearance between the tube and tube support as well as the normal contact force on the tubes by fluid should be maintained as low as possible. A simplified method is used for predicting fretting-wear damage of the double $90^{\circ}$U-bend tubes. The approach employed is based on the straight single-span tube analytical model proposed by Connors, the linear structural dynamic theory of Appendix N-1300 to ASME Section III and the Archard's equation for adhesive wear. Results from the presented method show a similar trend compared with the field data. This method can be utilized to predict the fretting-wear of the double $90^{\circ}$U-bend tubes in steam generators.

  • PDF

Fabrication of AlN piezoelectric micro power generator suitable with CMOS process and its characteristics (CMOS 공정에 적합한 AlN 압전 마이크로 발전기의 제작 및 특성)

  • Chung, Gwiy-Sang;Lee, Byung-Chul
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.209-213
    • /
    • 2010
  • This paper describes the fabrication and characteristics of AlN piezoelectric MPG(micro power generator). The micro energy harvester was fabricated to convert ambient vibration energy to electrical power as a AlN piezoelectric cantilever with Si proof-mass. To be compatible with CMOS process, AlN thin film was grown at low temperature by RF magnetron sputtering and micro power generators were fabricated by MEMS technologies. X-ray diffraction pattern proved that the grown AlN film had highly(002) orientation with low value of FWHM(full width at the half maximum, $\theta=0.276^{\circ}$) in the rocking curve around(002) reflections. The implemented harvester showed the $198.5\;{\mu}m$ highest membrane displacement and generated 6.4 nW of electrical power to $80\;k{\Omega}$ resistive load with $22.6\;mV_{rms}$ voltage from 1.0 G acceleration at its resonant frequency of 389 Hz. From these results, the AlN piezoelectric MPG will be possible to suitable with the batch process and confirm the possibility for power supply in portable, mobile and wearable microsystems.

Development of High Performance Intake Silencer Using Swirling Flow for Household Oxygen Generators (가정용 산소발생기를 위한 스월링 유동을 이용한 고성능 흡기 소음기 개발)

  • Kim, Seong-Hun;Lee, Gwang-Se;Choi, Yong-Bok;Cheong, Cheolung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.11
    • /
    • pp.846-853
    • /
    • 2014
  • High performance intake silencer with low pressure drop are developed for a household oxygen generator. First, the acoustic power of the target oxygen generator are experimentally evaluated according to ISO code. Then, the transmission loss of and the flow characteristics inside the existing intake silencer are predicted and analyzed. On a basis of these results, two intake silencers are proposed, which are designed to induce the swirling flow inside the intake silencer and thus to reduce the flow loss. The predicted TL and the pressure drop for these two new silencers are compared to the existing one, which shows that the proposed ones have higher TL as well as low pressure drop. The reason for these improvements are explained by investigating the flow characteristics of the new silencers in detail.

Field Test and Evaluation of Noise from Wind Turbine Generators at Yongdang and Hangwon in Jeju Island (제주도 용당/행원 풍력발전기 현장 소음 실증)

  • Cheong, Cheol-Ung;Jeong, Sung-Su;Cheung, Wan-Sup;Shin, Su-Hyun;Jeon, Se-Jong;Lee, Saeng-Hui
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.818-821
    • /
    • 2005
  • The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang and 660 kW WTG at Hangwon in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure levels (ECSPL) of 660 kW WTG at Hangwon vary more widely with wind speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

Identifications and Reduction Methods of Aerodynamic Noise Sources in High Speed Rotating Optical Disk Drive (고속으로 회전하는 광디스크 드라이브의 공력 소음원 규명 및 소음저감방법)

  • Kim, Yong-Seok;Lee, Duck-Joo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.6 s.123
    • /
    • pp.477-483
    • /
    • 2007
  • Major noise source in high speed rotating optical disk drives (CD and DVD-ROM) arises due to the high-speed airflow produced from the upper and lower surfaces on the rotating disk. The present paper deals with the experimental approach how to identify the noise source based on the fundamental principles of aeroacoustics and to propose a reduction method of the noise source. The CD-ROM device is composed of disk, window tray, motors at the bottom place and electronic circuit plate also located below the window plate. The window is cut in the tray to read the disk information using the optical device located below the tray and moving linearly from the center of the disk through the end of the disk. All components are possible noise generators. Experimental studies were carried out in the anechoic room with various design modifications, such as tray geometry, window size and hole location on tray, to identify the major aerodynamic noise source and significant reductions of the aerodynamic noise were obtained.

Finite Element Analyses on the Dynamic Behavior of Piezoelectric ZnO Nanowires and Their Piezoelectric Device Application Potentials (압전 산화아연 나노와이어의 동적거동 및 압전소자 응용성)

  • Lee, Woong
    • Korean Journal of Materials Research
    • /
    • v.31 no.1
    • /
    • pp.43-53
    • /
    • 2021
  • Dynamic behavior of piezoelectric ZnO nanowires is investigated using finite element analyses (FEA) on FE models constructed based on previous experimental observations in which nanowires having aspect ratios of 1:2. 1:31, and 1:57 are obtained during a hydrothermal process. Modal analyses predict that nanowires will vibrate in lateral bending, uniaxial elongation/contraction, and twisting (torsion), respectively, for the three ratios. The natural frequency for each vibration mode varies depending on the aspect ratio, while the frequencies are in a range of 7.233 MHz to 3.393 GHz. Subsequent transient response analysis predicts that the nanowires will behave quasi-statically within the load frequency range below 10 MHz, implying that the ZnO nanowires have application potentials as structural members of electromechanical systems including nano piezoelectric generators and piezoelectric dynamic strain sensors. When an electric pulse signal is simulated, it is predicted that the nanowires will deform in accordance with the electric signal. Once the electric signal is removed, the nanowires exhibit a specific resonance-like vibration, with the frequency synchronized to the signal frequency. These predictions indicate that the nanowires have additional application potential as piezoelectric actuators and resonators.

A Study on Flow Rate Properties and Optimal Selection of Nitrogen Membrane Module of Hollow Fiber Type (중공사형 질소 분리막 모듈의 최적 선정과 유량특성에 관한 연구)

  • Kim, Jong-Do;Lee, Sangu-Su;Kim, Jeon-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.915-922
    • /
    • 2008
  • The gas separation technology using membrane is widely used to refine various gases in many industry fields and recently is being applying in $CO_2$ recovery technology. In the gas and chemical tanker. nitrogen generators for inerting, purging and padding are on board and most of them have membrane modules of hollow fiber type with long life and vibration resisting properties. Because a membrane module is a key component accounting for 50% of total manufacturing cost of nitrogen generator, adequate selection for it is an important problem. In this paper, the flow performance coefficient based on dimension and specification data of membrane module was relatively selected to compare nitrogen generating capacity of module and various performance tests about the selected PARKER ST6010 membrane module were conducted. As a result, the useful coefficient and basic data in selecting a membrane module were achieved.