• 제목/요약/키워드: Vibration Velocity

검색결과 1,398건 처리시간 0.034초

다물체계의 자려진동 구현을 위한 마찰 모델링 (Friction Model to Realize Self-excited Vibration of Multi-body Systems)

  • 노현영;유홍희
    • 한국소음진동공학회논문집
    • /
    • 제17권6호
    • /
    • pp.524-530
    • /
    • 2007
  • This paper presents a friction model to realize self-excited vibration of multi-body systems. The friction coefficient is modeled with a spline function in most commercial codes. Even if such a function resolves the problem of discontinuity in friction force, it cannot realize self-excited vibration phenomena. Furthermore, as the relative velocity approaches zero, the friction coefficient approaches zero with the conventional model. So, slip occurs when small force is applied to the system. To avoid these problems a new friction model is proposed in this study. With the new friction model, the self-excited vibration can be realized since the friction coefficient changes with the relative velocity. Furthermore, the slip phenomena could be reduced significantly with the proposed model.

발파 현장에서 기폭 패턴 변화에 따른 진동 특성 분석 (Analysis of Vibration Characteristics Caused by the Change of Detonation Pattern in the Blasting Site)

  • 송정언
    • 화약ㆍ발파
    • /
    • 제42권1호
    • /
    • pp.12-22
    • /
    • 2024
  • 본 연구에서는 발파 현장에서 발파 구역을 구분하여 분할 발파를 실시할 때 구역 내 열간 기폭 패턴에 따른 진동 특성을 확인하기 위해 계측된 진동데이터를 통해 방향별 진동파형 및 진동속도, 주주파수를 비교 분석하였다. 결과적으로, 발파 구역 내 열간 기폭 패턴에 따라 방향별 진동파형의 변화를 나타냈으며, 진동속도 및 주주 파수대역 또한 다른 양상을 보이는 것으로 확인되었다.

슬롯드릴링공법의 유효제원에 관한 수치해석적 연구 (A Numerical Study on the Effective Dimension in Slot-drilling Method)

  • 윤지선;이지훈;손성훈
    • 화약ㆍ발파
    • /
    • 제28권2호
    • /
    • pp.50-58
    • /
    • 2010
  • 본 연구는 아직 국내에서 연구가 미비한 분야인 슬롯드릴링 공법에 대해 분석한 것이며 슬롯드릴링 공법을 공사현장에서 적용할 수 있는 이론적인 기반을 마련하고자 하였다. 본 연구는 슬롯드릴링 공법을 통해 진동저감의 가능성을 제안한다. 수치해석을 통해 슬롯드릴링의 유효제원 관해 크게 두 가지를 분석 하였다. 하나는 슬롯과 진원 사이의 거리에 따른 진동속도의 변화를 분석이며 다른 하나는 진동제어를 위한 적절한 크기의 슬롯너비와 슬롯높이를 찾고자 하였다. 결론적으로 진원과 슬롯사이의 거리가 멀어질수록 진동저감 효과가 감소함을 알 수 있었다. 그리고 슬롯제원의 변화에 따른 임의의 계측지점에서의 진동속도에 대한 영향도 확인할 수 있었다.

PZT actuator를 이용한 외팔보의 능동진동제어 (Active control of vibration of cantilever beams using PZT actuators)

  • 신창주;홍진숙;정의봉
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.247-252
    • /
    • 2008
  • This paper presents an active vibration control of cantilever beams under disturbances by a primary force. A direct velocity feedback control using a pair of PZT actuator and a velocity sensor is considered. Variation of the stability and performance with the locations of the sensor/actuator pair is investigated. It is found that the maximum gain varies with the locations of the sensor/actuator pair significantly. The maximum gain shows a symmetric distribution along the beam length with respect to the center point, although the boundary condition of the beam is unsymmetric. The control performance is affected by the location of the primary force as well as the location of the sensor/actuator pair. The active control system can more effectively reduce the vibration when the primary force is located close to the fixed boundary.

  • PDF

원전 정지냉각계통 배관 진동안전성 평가연구 (A Safety Evaluation Study by Vibration Analysis for Shutdown Cooling Piping System)

  • 이욱륜;이준신;손석만;김만희;송승용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.41-45
    • /
    • 2007
  • Palo Verde Unit 1 nuclear power station which is located in Arizona, USA had been operating at reduced power levels around 25% since December 25, 2005 due to vibration in one of its shutdown cooling lines. During an outage from March 18, 2006 to July 7, 2006 the necessary work and modifications to remedy the situation were performed. It cost approximately $46million to buy electricity to replace that lost as a result of this event. Therefore in this study, the vibration of shutdown cooling lines in the same nuclear power plant in Korea as Palo Verde Unit 1 should be measured by the operating condition of power plant. And it was evaluated using the expression for allowable velocity in ASME OM-S/G-2003. From the result of this study it is evaluated whether it is safe or not. If not the countermeasure should be considered in this study.

  • PDF

각속도 성분들이 머리진동 측정치에 미치는 영향 (Effects of Angular Velocity Components on Head Vibration Measurements)

  • Park Yong Hwa;Cheung Wan Sup
    • The Journal of the Acoustical Society of Korea
    • /
    • 제24권1E호
    • /
    • pp.7-15
    • /
    • 2005
  • This paper addresses issues encountered in measuring the general, 6-degree-of-freedom motion of a human head, A complete mathematical description for measuring the head motion using the six-accelerometer configured bite-bar is suggested, The description shows that the six-axis vibration cannot be completely obtained without the roll, pitch and yaw angular velocity components, A new method of estimating the three orthogonal (roll, pitch and yaw) angular velocities from the six acceleration measurements is introduced. The estimated angular velocities are shown to enable further quantitative error analysis in measuring the translational and angular accelerations at the head. To make this point clear, experimental results are also illustrated in this paper. They show that when the effects of angular velocities are neglected in the head vibration measurement the maximum percentage errors were observed to be more than $3 \%$ for the angular acceleration of the head and to be close to $5 \%$ for its translational acceleration, respectively. It means that the inclusion of all the angular velocity dependent acceleration components gives more accurate measurement of the head vibration.

터널굴착이 지상구조물에 미치는 영향평가 및 발파지침설계 (Ground Vibration in Tunnelling by Blasting and its Effect on Surface Structures)

  • 신희순;한공창;류창하;신중호;박연준;최영학
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.463-470
    • /
    • 2000
  • In tunnel excavation by blast beneath the surface structures in urban area, the characteristics of ground vibration induced by blast and its influence on surface structures are analyzed by the field test and the numerical analysis on dynamic behaviors of the structure. According to the field test on the propagating characteristics of blast vibration through the rock mass and the concrete foundation pile. the attenuation index of peak particle velocity with distance shows the range of 1.7∼2.0 for the rock mass and the range of 2.0∼2.3 for the concrete pile. This shows that the blast vibration reduces more rapidly in the concrete pile. It is known from the numerical analysis on dynamic behavior of the structure that the coefficient of response, velocity ratio of structure response to input wave, is different according to the story of the structure. It can be said from this research that the characteristics of the ground vibration and the dynamic behavior of the structure should be well evaluated and be considered as important factors for safe blasting design especially in underground excavation at shallow depth in urban area.

  • PDF

영구자석 스핀들 모터의 코깅토크가 회전디스크 굽힘 진동의 안정성에 미치는 영향 (Effects of Torque Fluctuation on the Stability of the Transverse Vibration of a Spinning Disk)

  • 이기녕;신응수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.942-947
    • /
    • 2001
  • This paper provides a stability analysis of the transverse vibration of a spinning disk under the torque fluctuation from a permanent magnetic motor. An analytical model has been formulated for a flexible annular disk with its spinning velocity varying harmonically with the same frequency as the cogging torque. A perturbation method based on multiple time scales is applied to perform the stability analysis. Based on expressions for the amplitude and frequency of the parametric excitation, stability boundaries are determined in terms of a nominal spindle velocity, the least common multiple of poles and slots, the magnitude of torque fluctuation and the modal characteristics of. the disk. The stability diagrams predicted by perturbation have been verified numerically using the Floquet theory, which is in good agreement. In conclusion, the fluctuation in spinning velocity is found to affect the stability of the transverse vibration of a rotating disks. The results of this work can be applied to high precision spindle systems such as computer storage systems.

  • PDF

신형경수로1400 증기발생기 전열관의 유체유발진동 해석 (Analysis of Fluid-Induced Vibration in the APR1400 Steam Generator Tube)

  • 이광한;정대율;변성철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.84-91
    • /
    • 2003
  • Flow-Induced Vibration of steam generator tubes may result in fretting wear damage at the tube-to-support locations. KSNP(Korean Standard Nuclear Power plant) steam generators experienced fretting wear in the upper part of U-bend above the central cavity region of steam generators. This region has conditions susceptible to the flow-induced vibration, such as high flow velocity, high void fraction, and longer unsupported span. To improve its performance, APR1400 steam generator is designed with additional supports in this region to reduce unsupported span and to reduce peak velocity in the central cavity region. In this paper, we examined its performance improvement using ATHOS code. The thermal-hydraulic condition in the region of secondary side of APR1400 steam generator is obtained using the ATHOS3 code. The effective mass for modal analysis is calculated using the void fraction, enthalpy, and operating pressure information from ATHOS3 code result. With the effective mass distribution along the tube, natural frequency and mode shape is obtained using ANSYS code. Finally, stability ratios and real mean squared displacements for selected tubes of the APR1400 steam generator are computed. From these results, the current design of the APR1400 steam generator are examined.

  • PDF

발파진동에 대한 구조물 안정성 평가 - 지하비축기지 건설 사례 (A Case Study on the Stability Assessment of Structures by Blast-induced Vibration)

  • 이정인;최용근;정용훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.479-484
    • /
    • 2005
  • The test blasts were carried out by detonating some single blastholes at two upper sites of the underground storage cavern the crude oil. One was performed at the entrance site of the construction tunnel and the other at the middle part of the underground storage cavern. Based on the blast-induced vibration measured by the test blasts, we suggested the propagation equations of blasting vibration that were capable of estimating the peak particle velocity. In addition, in order to assess the stability of the nearest ground storage tank, we did the frequency analysis and the response spectrum analysis with the particle velocity-time history and the particle acceleration-time history that were measured by the test blast carried out on the entrance site of the construction tunnel. In result, it was predicted that the displacement on the highest part of the tank shell was less than the allowable displacement.

  • PDF