• Title/Summary/Keyword: Via stub

Search Result 17, Processing Time 0.02 seconds

Empirical Model of Via-Hole Structures in High-Count Multi-Layered Printed Circuit Board (HCML 배선기판에서 비아홀 구조에 대한 경험적 모델)

  • Kim, Young-Woo;Lim, Yeong-Seog
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.12
    • /
    • pp.55-67
    • /
    • 2010
  • The electrical properties of a back drilled via-hole (BDH) without the open-stub and the plated through via-hole (PTH) with the open-stub, which is called the conventional structure, in a high-count multi~layered (HCML) printed circuit board (PCB) were investigated for a high-speed digital system, and a selected inner layer to transmit a high-speed signal was farthest away from the side to mount the component. Within 10 GHz of the broadband frequency, a design of experiment (DOE) methodology was carried out with three cause factors of each via-hole structure, which were the distance between the via-holes, the dimensions of drilling pad and the anti-pad in the ground plane, and then the relation between cause and result factors which were the maximum return loss, the half-power frequency, and the minimum insertion loss was analyzed. Subsequently, the empirical formulae resulting in a macro model were extracted and compared with the experiment results. Even, out of the cause range, the calculated results obtained from the macro model can be also matched with the measured results within 5 % of the error.

Performance Analysis of High-Speed Transmission Line for Terabit Per Second Switch Fabric Interface (테라급 스위치 패브릭 인터페이스를 위한 고속 신호 전송로의 성능 분석)

  • Choi, Chang-Ho;Kim, Whan-Woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.46-55
    • /
    • 2014
  • PCB design technology for high-speed transmission line has been developed continuously. Adapting to the high capacity of the communication system, switch fabric interface used for backplane is being standardized to accommodate more than 10Gbps serial interface. In this paper, various computer simulations are performed to compare the performance of each transmission line per length according to PCB material, and also to analyze the effect from via stub length and crosstalk, for the purpose of applying 11.5Gbps serial interface as a switch fabric interface in tera-bit switching system. As a result of the simulation, important design issues, such as PCB material of each board supporting 8dB improvement in transmission loss using low loss PCB, maximum available stub length on transmission line via, whether or not to apply the backdrill process to the via, and the clearance of the differential pair between transmission lines, are determined. The most efficient system architecture which could be applied 11.5Gbps serial interface in all switch fabric interfaces is defined from the simulation results.

A Study on the EMC Characteristics of Bare PCB for Reliability of High-Multilayer PCB (고다층 보드 신뢰성 확보를 위한 베어보드 EMC 특성 연구)

  • Jin Sung Park;Kihyun Kim;Kyoung Min Kim;Sung Yong Kim
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.94-98
    • /
    • 2023
  • In the case of high-speed data transmission on high multilayer boards, signal coherence is a problem, especially due to the via hole, and a solution to improve return loss or insertion loss by applying a back drill to the via hole is being proposed. In this paper, Near-Field Electromagnetic measurements were made on a high multilayer board to determine how the presence or absence of back drill affects signal consistency. For this purpose, we used a signal generator, spectrum analyzer, and EMC scanner on a test board to determine if it is possible to distinguish between areas with and without back drill in the via holes of the stubs on the board. Also, we analyzed the measured value of S11, S21 and EMC etc. for how much it improves the signal attenuation of the stub with back drill. Through this, we knew that less electromagnetic waves are generated the stub via with back drill. At future research, we will analyze how much it improves the signal loss and electromagnetic waves due to the depth of back drill.

  • PDF

Axial compressive behaviour of stub concrete-filled columns with elliptical stainless steel hollow sections

  • Dai, X.;Lam, D.
    • Steel and Composite Structures
    • /
    • v.10 no.6
    • /
    • pp.517-539
    • /
    • 2010
  • This paper presents the axial compressive behaviour of stub concrete-filled columns with elliptical stainless steel and carbon steel hollow sections. The finite element method developed via ABAQUS/Standard solver was used to carry out the simulations. The accuracy of the FE modelling and the proposed confined concrete stress-strain model were verified against experimental results. A parametric study on stub concrete-filled columns with various elliptical hollow sections made with stainless steel and carbon steel was conducted. The comparisons and analyses presented in this paper outline the effect of hollow sectional configurations to the axial compressive behaviour of elliptical concrete-filled steel tubular columns, especially the merits of using stainless steel hollow sections is highlighted.

Closely Spaced Two-Element Folded-Dipole-Driven Quasi-Yagi Array

  • Ta, Son Xuat;Kang, Sang-Gu;Park, Ikmo
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.4
    • /
    • pp.254-259
    • /
    • 2012
  • This paper presents a closely spaced two-element folded-dipole-driven quasi-Yagi array with low mutual coupling between adjacent elements. The antenna utilizes a T-junction power divider as the feeding network, with an input impedance of $50{\Omega}$. A microstrip-stub is added to the ground plane in the middle of the two elements to improve the mutual coupling characteristics. The folded dipole driver is connected to a $50{\Omega}$ microstrip line via a broadband microstrip-to-coplanar stripline transition with a quarter radial stub. A mutual coupling of less than -22 dB is measured between two folded-dipole-driven quasi-Yagi antennas with a center-to-center spacing of 30 mm ($0.55{\lambda}_0$ at 5.5 GHz). The proposed quasi-Yagi array yields a measured bandwidth of 4.75~6.43 GHz for the -10 dB reflection coefficient and a gain of 6.14~7.12 dBi within the bandwidth range.

Improvement of the Radiation Efficiency for a CPW(Co-Planar Waveguide)-Fed ZOR(Zeroth-Order Resonant) Antenna (Co-Planar Waveguide(CPW) 급전 영차 공진 안테나의 방사효율 개선)

  • Cho, Tae-Joon;Lee, Hong-Min
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • In this paper, a co-planar waveguide(CPW)-fed zeroth-order resonant(ZOR) antenna with an improved radiation efficiency was built and tested. The unit cell of the proposed antenna consists of a series metal-insulator-metal(MIM) capacitor and a shorted shunt stub inductor. In order to reduce the antenna size and to achieve the high radiation efficiency two shorted shunt stub arms bent by 90 degree were connected to the ground plane through the via. The proposed antenna consisting of two unit cells has an open ended composite right/left-handed(CRLH) transmission line structure. As a result the dominantly radiating parts of the antenna comes from shunt stub arms and vertical vias. The total size of the fabricated zeroth-order resonant antenna is $0.22\;{\lambda}_0{\times}0.22\;{\lambda}_0$. The measured gain and efficiency of the fabricated antenna have been enhanced by 3.07 dBi and 75 %, respectively, at the zeroth-order resonant frequency of 2.97 GHz.

Design of Meander Chip Antenna with Gap Stub for Dual-Band(GPS/K-PCS) Operation (갭 스터브가 삽입된 이중 대역(GPS, K-PCS) 미엔더 칩 안테나 설계)

  • Kim Young-Do;Sin Kyung-Sup;Won Chung-ho;Lee Hong-Min
    • Proceedings of the IEEK Conference
    • /
    • 2004.06a
    • /
    • pp.217-220
    • /
    • 2004
  • This paper presents design simulation, implementation, and measurement of a miniaturized GPS/K-PCS dual-band LTCC chip antenna for mobile communication handsets. The dimension of LTCC chip antenna is $9mm{\times}15mm{\times}1.2mm$. The lower meander type antenna is to be tuned to the lower frequency (GPS) band and the upper meander antenna with via hole connection is to contribute the higher frequency (K-PCS) band. In order to lowering the resonant frequency for GPS band, two printed modified meander antenna with gap stub is used to integrate with PCS band operation. The measured resonant frequency at GPS band shifts to lower frequency about 100MHz. The measured impedance bandwidth(VSWR $\leq$ 2) are 55MHz and 120MHz at the resonant frequency. respectively.

  • PDF

Design of a Dual Band-pass Filter Using Fork-type Open Stubs and SIR Structure (포크 형태의 개방형 스터브 및 SIR 구조를 이용한 이중대역 대역통과 여파기의 설계)

  • Tae-Hyeon Lee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.1
    • /
    • pp.252-264
    • /
    • 2023
  • This paper proposes a design of a dual-band band-pass filter that integrates a λg/2 open SIR structure, a transmission line, and a fork-type structure with symmetric and asymmetric open stubs. To obtain the dual-band effect, the proposed filter uses the SIR structure and adjusts the impedance ratio of the SIR structure. Therefore, the position of the harmonics of the filter is shifted through the adjustment of the impedance ratio, and this can obtain a double-band effect. In order to obtain the dual-band characteristics, the dual-band effect is obtained by inserting a open stub between the SIR structures with the SIR structure divided in half. In addition, the second frequency response is obtained by adjusting the length of the open symmetrical stub in the fork-shaped structure. The asymmetrical open stub in the fork form achieves optimum bandwidth by adjusting the length. Therefore, the first center frequency of the proposed band-pass filter is 5.896 GHz and the bandwidth is 13.6 %. At this time, the measurement results are 0.13 dB and 33.6 dB. The second center frequency is 5.906 GHz and the bandwidth is 13.6 %. At this time, the measurement results are 0.15 dB and 19.8 dB. The reason is that when the impedance ratio (Δ) is higher than 1, the position of the harmonic is shifted to a lower frequency band. However, if the impedance ratio (Δ) is lowered by one step, the position of harmonics will move to a higher frequency band. The function of the filter designed using these characteristics can be obtained from the measurement result. The proposed band-pass filter has no coupling loss and no via energy concentration loss because there is no coupling structure of input/output and no via hole. Therefore, system integration is possible due to its excellent performance, and it is expected that dedicated short-range communication (DSRC) system applications used in traffic communication systems will be possible.

Experimental behavior of VHSC encased composite stub column under compression and end moment

  • Huang, Zhenyu;Huang, Xinxiong;Li, Weiwen;Mei, Liu;Liew, J.Y. Richard
    • Steel and Composite Structures
    • /
    • v.31 no.1
    • /
    • pp.69-83
    • /
    • 2019
  • This paper investigates the structural behavior of very high strength concrete encased steel composite columns via combined experimental and analytical study. The experimental programme examines stub composite columns under pure compression and eccentric compression. The experimental results show that the high strength encased concrete composite column exhibits brittle post peak behavior and low ductility but has acceptable compressive resistance. The high strength concrete encased composite column subjected to early spalling and initial flexural cracking due to its brittle nature that may degrade the stiffness and ultimate resistance. The analytical study compares the current code methods (ACI 318, Eurocode 4, AISC 360 and Chinese JGJ 138) in predicting the compressive resistance of the high strength concrete encased composite columns to verify the accuracy. The plastic design resistance may not be fully achieved. A database including the concrete encased composite column under concentered and eccentric compression is established to verify the predictions using the proposed elastic, elastoplastic and plastic methods. Image-oriented intelligent recognition tool-based fiber element method is programmed to predict the load resistances. It is found that the plastic method can give an accurate prediction of the load resistance for the encased composite column using normal strength concrete (20-60 MPa) while the elastoplastic method provides reasonably conservative predictions for the encased composite column using high strength concrete (60-120 MPa).

Design of Broadband Quasi-Yagi Antenna Using a Folded Dipole Driver

  • Ta, Son Xuat;Kim, Byoung-Chul;Choo, Ho-Sung;Park, Ik-Mo
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.3
    • /
    • pp.227-233
    • /
    • 2011
  • This paper describes the development of a broadband quasi-Yagi antenna using a folded dipole driver. The antenna is designed on a low-permittivity substrate to reduce the surface wave effect, and hence the gain can be enhanced easily by adding directors. The folded dipole driver is connected to a 50-${\Omega}$ microstripline via a simple broadband microstrip-to-coplanar stripline transition with a quarter radial stub. The key motivation for the use of a folded dipole is to increase the input impedance at the driver, allowing a smaller mismatch loss between the antenna driver and the coplanar stripline feed. The proposed antenna has a measured bandwidth of 4.67~6.26 GHz for the -10 dB reflection coefficient, and a flat gain of 4.86~5.15 dB within the bandwidth.