• Title/Summary/Keyword: Via Hole

Search Result 299, Processing Time 0.028 seconds

Enhanced Efficiency of Organic Electroluminescence Diode Using 2-TNATA:C60 Hole Injection Layer (2-TNATA:C60 정공 주입층을 이용한 유기발광다이오드의 성능 향상 연구)

  • Park, So-Hyun;Kang, Do-Soon;Park, Dae-Won;Choe, Young-Son
    • Polymer(Korea)
    • /
    • v.32 no.4
    • /
    • pp.372-376
    • /
    • 2008
  • Vacuum deposited 4,4',4"-tris(N-(2-naphthyl)-N-phenylamino)-triphenylamine (2-TNATA), used as a hole injection (HIL) material in OLEDs, is placed as a thin interlayer between indium tin oxide (ITO) electrode and a hole transporting layer (HTL) in the devices. C60-doped 2-TNATA:C60 (20 wt%) film was formed via co-evaporation process and molecular ordering and topology of 2-TNATA:C60 films were investigated using XRD and AFM. The J-V, L-V and current efficiency of multi-layered devices were characterized as well. Vacuum-deposited C60 film was molecularly oriented, but neither was 2-TNATA:C60 film due to the uniform dispersion of C60 molecules in the film. By using C60-doped 2-TNATA:C60 film as a HIL, the current density and luminance of a multi-layered ITO/2-TNATA:C60/NPD/$Alq_3$/LiF/Al device were significantly increased and the current efficiency of the device was increased from 4.7 to 6.7 cd/A in the present study.

Microsurgical Decompression for Lumbar Stenosis via Unilateral Laminotomy (요추 협착증에 대한 일측성 추궁절개술을 통한 미세 수술적 감압술)

  • Shim, Yong-Jin;Ha, Ho-Gyun;Lee, Jong-Sun;Kim, Yong-Seog;Park, Moon-Sun;Kim, Joo-Seung
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.11
    • /
    • pp.1505-1513
    • /
    • 2000
  • Objectives : Many surgical procedures have been introduced to a symptomatic lumbar stenosis. Most of these procedures still have been regarded as an extensive surgical intervention with respect to normal aging process of the lumbar spine. We adopted a microsurgical decompression procedure via unilateral exposure as a minimally invasive intervention for symptomatic lumbar stenosis without instability. Materials and Methods : Fifty-seven patients with symptomatic lumbar stenosis underwent microsurgical decompression via unilateral laminotomy between March 1998 and December 1999. The conceptual modification and technical refinements were added to the previously reported microsurgical decompression procedure. Bilateral decompression through a unilateral laminotomy hole was performed in 11 patients. These patients profile also included 9 cases of degenerative spondylolisthesis(Grade I) without instability. Results : Preoperative neurogenic intermittent claudication(NIC) was more notably improved than low back pain, 60% to 82% during the follow-up period. Overall clinical results were excellent in 20(35%), good in 29(51%), fair in 6(11%) and poor in 2(3%). Conclusions : Microsurgical decompression for lumbar stenosis with stable spine provided a satisfactory symptomatic improvement without extensive destruction of the weight-bearing structures and functional mobile segments, even bilateral symptoms existed.

  • PDF

Transmission Line using Microstrip-Slotline Transition Technology and Its Application to Power Divider (마이크로스트립과 슬롯라인 천이기술을 이용한 전송선로 구현과 전력 분배기에 응용)

  • Kim, Young;Sim, Seok-Hyun;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.687-692
    • /
    • 2013
  • This paper presents a compact power divider using microstrip-slotline transition technology. By using the microstrip-slotline transition, the ${\lambda}/4$ transmission lines of the divider can be changed to two ${\lambda}/8$ transmission lines in the multilayer structure. In the microstrip-slotline transition, we have used via holes to make a short circuit at the microstrip line and embedded spiral configuration stubs to reduce the electrical length of an open circuit at the slotline end point. For validating the microstrip-slotline technique, we have simulated and implemented the power divider with embedded spiral and via hole configuration circuits at a frequency of 2 GHz. Good agreement between the simulation and the measurement results is obtained at the operating frequency.

Seismic Research Network in KIGAM (한국자원연구소 지진 네트워크)

  • 이희일
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.49-56
    • /
    • 2000
  • Instrumental observation of earth quakes in KIGAM was first attempted in the earty 1980`s by using 6 portable seismographs in the vicinity of Yang-San Faults. Now twenty-four permanent stations, which are equipped with short-period or broad-band seismometer, are included in seismic research network in KIGAM, including KSRS array station in Wonju which is consisted of 26 bore-hole stations. The seismic network of KIGAM is also linked to that of KEPRI(Korea Electric Power Research Institute)which is consisted of eight stations installed within and around the nuclear power plants. Owing to real-time data acquisition by telemetry, it became feasible to automatically locate hypocenters of the local events within fifteen minutes by computer data processing system, named KEMS(Korea Earthquake Monitoring System). Results of the hypocenter determination, together with observational data, are compiled and stored in the data base system. And they are published via web site whose URL is http://quake.kigam.re.kr KIGAM is also running t재 permanent geomagnetic stations installed in Daejun and Kyungju. The observed geomagnetic data are transmitted to Earthquake Research Centre in KIGAM by seismic network and compiled for the purpose of earthquake prediction research and other basic geophysical research.

  • PDF

Effective Arthroscopic Treatment of Huge and Anteriorly Extended Spinoglenoid Cysts

  • Park, Jung-Ho;Lee, Yong-Seuk;Lee, Jun-Yong;Kim, Jae-Gyun
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2008.03a
    • /
    • pp.5-5
    • /
    • 2008
  • Spinoglenoid cyst of the shoulder is a rare clinical entity and several treatment modalities have been reported. Recently, arthroscopy is effectively used via communication hole or posterior capsulotomy through the glenohumeral joint. With this method, the complete cystectomy is impossible if the cyst is a large size or extended anteriorly and there are few reports about such cases. We present extra-articular complete cystectomy through bursal space in 3 cases of huge and anteriorly extended spinoglenoid cysts. All patients were able to return to work with no restrictions and 2 patients who performed the follow up MRI demonstrated complete resolution of the cyst and some recovery of the mass of infraspinatus muscle.

  • PDF

A Study on the Optimized Copper Electrochemical Plating in Dual Damascene Process

  • Yoo, Hae-Young;Chang, Eui-Goo;Kim, Nam-Hoon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.5
    • /
    • pp.225-228
    • /
    • 2005
  • In this work, we studied the optimized copper thickness in Cu ECP (Electrochemical Plating). In order to select an optimized Cu ECP thickness, we examined Cu ECP bulge (bump, hump or over-plating amount), Cu CMP dishing and electrical properties of via hole and line trench over dual damascene patterned wafers split into different ECP Cu thickness. In the aspect of bump and dishing, the bulge increased according as target plating thickness decreased. Dishing of edge was larger than center of wafer. Also in case of electrical property, metal line resistance distribution became broad gradually according as Cu ECP thickness decreased. In conclusion, at least $20\%$ reduced Cu ECP thickness from current baseline; $0.8\;{\mu}m$ and $1.0\;{\mu}m$ are suitable to be adopted as newly optimized Cu ECP thickness for local and intermediate layer.

AGN BROAD LINE REGIONS SCALE WITH BOLOMETRIC LUMINOSITY

  • TRIPPE, SASCHA
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.3
    • /
    • pp.203-206
    • /
    • 2015
  • The masses of supermassive black holes in active galactic nuclei (AGN) can be derived spectroscopically via virial mass estimators based on selected broad optical/ultraviolet emission lines. These estimates commonly use the line width as a proxy for the gas speed and the monochromatic continuum luminosity, λLλ, as a proxy for the radius of the broad line region. However, if the size of the broad line region scales with the bolometric AGN luminosity rather than λLλ, mass estimates based on different emission lines will show a systematic discrepancy which is a function of the color of the AGN continuum. This has actually been observed in mass estimates based on Hα/Hβ and CIV lines, indicating that AGN broad line regions indeed scale with bolometric luminosity. Given that this effect seems to have been overlooked as yet, currently used single-epoch mass estimates are likely to be biased.

The Study on Testability of high Speed and High Integrated Multichip Module (고속, 고집적 Multichip Module의 시험성 확보에 관한 고찰)

  • 김승곤
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.5 no.2
    • /
    • pp.21-26
    • /
    • 1998
  • 대용량, 고속데이터 처리가 요구되는 System 개발은 이들의 복잡하고 고기능의 회 로 구현이 가능하냐에 달려 있고 또한 이들고기능 요구를 가장 잘 만족할수 있는 패키지는 MCM 이라 할 수있다. 시스템의 고속화, 소형화는 회로의 복잡성을 요구하는 있는 이를 패 키지로 구현하는 MCM은 시험성 확보에 심각한 문제점으로 나타나고 있다. 본 논문에서는 고밀도 구조의 MCM 기판에 대한 Interconnetion Line 시험검증을 위한 Flying Prober의 적 용 및 모듈 패키징 공정에 대한 조립성 검증을 위한 BST에 대해 설명한다. 연구에 사용된 MCM 모듈은 MCM-D 공정으로 제작되었으며 31um 신호선폭, 50um Via Hole Dia. 5신호 선층 5절연층 및 455 Net의 기판으로절연층은 Dow chemical의 BCB-4024/4026을 적용하였 다. 조립은 3 ASIC, 24소자 실장 및 2000 Wire Bonding으로 이루어지며 패키지는 방열특성 을 고려한 BGA(491 I /O,50mil pitch)를 개발하여 사용하였다. MCM 기판의미세패턴으로 구성된 Interconnection Line에 대해 Fine Ptich Probing이 가능한 Flying Prober를 사용하 여 평가하였으며 BST를 이용하여 실장소자의 KGD평가 및 능동, 수동소자가 실장된 MCM Package의 조립시험성을 확보할수 있었다.

Characteristic Analysis of $Al_2$O$_3$Thin Films Grown by Atomic Layer Deposition (ALD법으로 성장시킨 $Al_2$O$_3$ 박막의 특성분석)

  • 성석재;김동진;배영호;이정희
    • Proceedings of the IEEK Conference
    • /
    • 2001.06b
    • /
    • pp.185-188
    • /
    • 2001
  • In this study, $Al_2$O$_3$films have been deposited with Atomic Layer Deposition(ALD) for gate insulator for MPTMA and $H_2O$ at low temperature below 40$0^{\circ}C$ . Conventional methods of $Al_2$O$_3$thin film deposition have suffered from the poor step coverage due to reduction of device dimension and increasing contact/via hole aspect ratio. ALD is a self-limiting growth process with controlled surface reaction where the growth rate is only dependent on the number of growth cycle and the lattice parameter of materials. ALD growth process has many advantages including accurate thickness control, large area and large batch capability, good uniformity, and pinholes freeness.

  • PDF

Visual Quality Optimization for Privacy Protection Bar-based Secure Image Display Technique

  • Park, Sanghyun;Kang, Sang-ug
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.7
    • /
    • pp.3664-3677
    • /
    • 2017
  • Abrupt scene changes generally incur the afterimage effect. So, the unblocked image portion is still viewed by human eyes just after it is blocked by some pattern. Yovo's secure display method utilized this phenomenon and it is systematically analyzed using computational afterimage modeling by replacing the complex afterimage effect via simple low-pass filtering. With this approach, realistic images perceived by the human eye can be computationally generated at every single moment, especially reflecting the afterimage effect. The generated images are compared with the original images to determine the factors that affect the image quality of the secure display method. The simulation results demonstrate that the ratio of the unblocked portion to the blocked portion of an image and the playback rate are two primary factors related to the recognized image quality. We also found that the two factors are still effective for generalized secure display techniques.