• Title/Summary/Keyword: Vertical temperature difference

Search Result 261, Processing Time 0.025 seconds

Natural convection cooling of discrete heaters with same heat generation in a vertical open top cavity (상부가 개방된 수직 캐비티내에 장착된 불연속 균일 발열체의 자연대류 냉각)

  • Yu, Gap-Jong;Chu, Hong-Rok;Kim, Byeong-Ha;Choe, Byeong-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 1997
  • Natural convection cooling of discrete heaters located in a two-dimensional vertical open top cavity is investigated experimentally. The five discrete heaters with same heat generation are located on the wall of the cavity. The heaters are arranged in two configurations; flush-mounted on a vertical wall and protruding from the wall about 4.5 mm. The materials used for the vertical walls are copper and epoxy-resin, and air is used as the cooling fluid. The temperature and flow fields in the cavity were visualized by means of Mach-Zehnder interferometer and smoke-method. Also, local temperature measurements are made along the vertical wall. Results are obtained for cavity aspect ratios of 4.6, 7.5 and 9.5 and modified Rayleigh numbers ranging from 10$^{3}$ to 10$^{6}$ . Results indicate that the cooling efficiency for the copper wall is superior to that of the epoxy-resin. For the epoxy-resin wall, the protrusion of the heaters plays a role in decreasing the heat transfer performance. The location of maximum temperature is significantly influenced by the wall materials and heater configurations. Correlations relating the Nusselt number to the modified Rayleigh number are proposed.

NUMERICAL SOLUTIONS OF AN IMPACT OF NATURAL CONVECTION ON MHD FLOW PAST A VERTICAL PLATE WITH SUCTION OR INJECTION

  • Ambethkar, V.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.12 no.4
    • /
    • pp.201-202
    • /
    • 2008
  • Because of the importance of suction or injection in the fields of aerodynamics, space science and many other industrial applications, our present study is motivated. The effect of natural convection on MHD flow past a vertical plate with suction or injection is studied. We have tried to solve the dimensionless governing equations by using finite difference scheme. To ensure the validity of our numerical solutions, we have compared our numerical solutions for temperature and velocity for the case of suction and injection for unit Prandtl number with the available exact solutions in the literature. The corresponding codes were written in Mathematica 5.0 for calculating numerical solutions for temperature and velocity and the comparison between the exact and numerical solutions. For the purpose of discussing the results some numerical calculations are carried out for non-dimensional temperature T, velocity u, skin friction ${\tau}$ and the Nusselt number $N_u$, by making use of it, the rate of heat transfer is studied.

  • PDF

A Phytogeographical Study on the Distribution of Bamboos in the Korean Peninsula (韓半島의 대나무類 分布와 그 環境要因에 관한 植物地理學的 硏究)

  • Kong, Woo Seok
    • The Korean Journal of Ecology
    • /
    • v.8 no.2
    • /
    • pp.89-98
    • /
    • 1985
  • Correlations between horizontal distributions of bamboos (Bambusaceae) in the Korean peninsula and environmental factors were studied using taxanomic and geographical literatures, both old and current. The vertical distributions of bamboos on Mt. Chiri were also studied, and environmental factors limiting horizontal and vertical distributions were compared. There are 18 species of bamboos (belonging to 5 genera) distributed in the Korean peninsula. The distributional range of each genus were distinct, although overlapped. Northern limit of bamboos of any species was marked by the line connecting Paikryung Island (124。40'E, 38。00'N), Mt. Changsoo, Mt. Myungji, Mt. Myohyung and Myungchum (129。40'E, 41。10'N). The optimum range of bamboos was concluded to be restricted to several southern province, with annual precipitation over 1,200 mm. The limiting factors on the distribution were inferred to be low temperature and duration of it. Mean daily minimum temperature of January and the number of days with daily mean temperatures below zero during January showed close associations with the distributional range, and an environmental factors favouring the distributrion of bamboos appeared to be vicinity of warm sea current, deep and extended snow acculation and southern exposure. The vertical distribution of bamboos on Mt. Chiri was limited by low temperature, unfavorable topographic and edaphic conditions caused by steep slope. Difference in the vertical limits between SE and NW slopes are caused by the differences in temperature and precipitation between the slopes. Bamboos were more abundant in valleys than on the ridge, apparently because the deeper snow in the valleys protected the plants from low temperature, heavy winter winds and desiccation.

  • PDF

Study on The Free Convection in a Heated Vertical Open Tube (수직관내에서의 자연대류에 관한 연구)

  • ;;Kim, Hee Dong
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.1 no.3
    • /
    • pp.146-155
    • /
    • 1977
  • The free convection in a vertical tube open at both ends and heated at the heated at the wall is studied by analytical approach and checked by experiment. The flow is assumed to be both stable and laminar. The incompressible boundary layer equations fot the system were solved by a finite difference method for conditions of constant wall temperature and conctant wall heat flux. Temperature profiles of the flow in the tube were measured by thermocouples and are compared with the calculated profiles. Agreement of the analytical and experimental results was good.

A Study on the Airflow near the Cold Heat Source Using CFD in Merchandising Store (CFD를 이용한 대형매장 냉열원 주변의 공기유동에 관한 연구)

  • Cho Sung Woo;Park Min Young;Im Young Bin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.629-634
    • /
    • 2005
  • This paper performed to predict vertical temperature distribution and air flow near cold heat source in the mass merchandising store. At the height of 150 cm, the vertical air temperature difference between the results of CFD and of measurement field showed $10\%$ near the refrigeration zone and $8.8\%$ near the freezing zone. Therefore, it regarded as appropriate for the using CFD to investigate airflow near the heat sources. The 3 kinds of CFD model were divided by the disposition of diffuser/exhaust and diffuser air temperature. At the refrigeration and freezing zone in the Model 2 and 3, the temperature difference between the front and the back of human model were showed $6.8^{\circ}C\;and\;3.9^{\circ}C$ with diffuser air temperature $17^{\circ}C$ and were showed $6.8^{\circ}C$ and $4^{\circ}C$ with diffuser air temperature $19^{\circ}C$.

A Experimental Study for Developing of the Dry Double Floors Hydronic Ondol System (건식이중바닥온돌시스템 개발을 위한 실험적 연구)

  • Kim Nan-Haeng;Sohn Jang-Yeul
    • Journal of the Korean housing association
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2006
  • The aim of the research was to evaluate the characteristics of thermal environment and thermal comfort in the Dry Double floors Hydronic Ondol System. Physical indoor thermal environments (the floor surface temperature, the vertical temperature, etc.) and skin temperature have especially been measured. Physical features conditions, sensation, thermal comfort, humidity sensation, comfort of body were investigated for the survey. As a result, (1) During the operation of the boiler (12 hour), the average indoor temperature is appeared to be $21.6^{\circ}C$. The floor surface temperature showed peak value of $31.4{\sim}40.6^{\circ}C$ after 8hours 30minutes after the start-point of the heating. The vertical difference of temperature was turned out to be not uniform. (2) While the skin temperature showed a narrow distribution of temperature in the Dry Double floors Hydronic Ondol system. (3) The response to thermal comfort which people felt was satisfactory, and most of them felt dry during the test.

Indoors Thermal Environment by Vertical Temperature Differences in Atrium Space (아트리움형 공간 내 수직온도차에 따른 온열환경)

  • We, Seunghwan;Lee, Jongki;Kim, Sughwan;Kim, Sumin;Chang, Jae D.
    • Journal of the Korea Furniture Society
    • /
    • v.25 no.2
    • /
    • pp.122-128
    • /
    • 2014
  • Recently, many studies have conducted to satisfy a physical need of human between environment of light on space, so an atrium structure has been applied to cultural complex. However, this structure brings about many problems such as overheating in summer, excessive vertical temperature differences, condensation, diffusion of noise, effect of echo, and withering landscapes. Especially, in this research, thermal comfort by difference of vertical temperature in the space of atrium and the optical characteristics of glass skins of the atrium could be remarkably effected by solar flux entering indoors.

  • PDF

A Study of Heat Transfer during Freezing Process of Water in a Vertical Cylinder. (수직 원통형 축열조내 물의 응고 과정시 열전달에 관한 실험적 연구(작동 유체의 유동방향에 따른 열저장 성능 비교))

  • Heo, Gyeong;Kim, Young-Ki;Kim, Young-Jung;Kim, Jun-Geun;Lim, Jang-Sun
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.223-229
    • /
    • 1995
  • Heat transfer phenomena during freezing process of the water in a vertical cylinder were experimentally studied. Purified water was inserted into the vertical cylinder Experiment was performed with two conditions ; the inlet temperature of the working fluid was maintained to be -1$0^{\circ}C$ and the direction of the working fluid was to be upward or downward. Both the mean temperature of the liquid and temperature difference of cylinder tube wall in the upward were lower than those in the downward. In addition, shape of ice layer in the upward was more uniform than that in the downward. Finally, time-varying total heat energy stored in the water in the upward was higher than that in the downward.

  • PDF

Analysis of Solidification Process Around a Vertical Tube Considering Density Change and Natural Convection (수직원관 주위에서 밀도차와 자연대류를 고려한 응고과정 해석)

  • 김무근;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.142-155
    • /
    • 1992
  • Numerical analysis is performed for the unsteady axisymmetric two dimensional phase change problem of freezing of water around a vertical tube. Heat conduction in the tube wall and solid phase, natural convection in liquid phase and volume expansion caused by density difference between solid and liquid phases are included in the numerical analysis. Existing correlation is used for estimating density-temperature relation of water, and the effect of volume expansion is reflected as fluid velocity at the interface and the free surface. As pure water has maximum density at 4.deg. C, it is found that there exists an initial temperature at which the flow direction reverses near the interface and by this effect the slope of interface becomes reversed depending on the initial temperature of water. By considering natural convection and solid-liquid density difference in the calculation, their effects on phase change process are studied and the effects of various parameters are also studied quantitatively.

A Study on Thermal Stratification Phenomenon due to In-Leakage in the Safety Injection Piping of Nuclear Power Plant (원전 안전주입 배관에서의 In-Leakage 에 의한 열성층 현상에 관한 연구)

  • Kim, K.C.;Park, M.H.;Youm, H.K.;Kim, T.Y.;Lee, S.K.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1633-1638
    • /
    • 2003
  • In case that in-leakage through the valve disk occurs, a numerical study is performed to estimate on thermal stratification phenomenon in the Safety Injection piping connected with the Reactor Coolant System piping of Nuclear Power Plant. As the leakage flow rate increases, the temperature difference between top and bottom of horizontal piping has the inflection point. In the connection point of valve and piping, the maximum temperature difference between top and bottom was 185K and occurred in the condition of 10 times of standard leakage flow rate. In the connection point of elbow and horizontal piping, the maximum temperature difference was 145K and occurred in the condition of 15 times of standard leakage flow rate. In the vertical piping of Safety Injection piping, the near of connection point between elbow and vertical piping showed the outstanding thermal stratification phenomenon in comparison with another region because of turbulent penetration from Reactor Coolant System piping. In order to prevent damage of piping due to the thermal stratification when in-leakage through the valve disk occurs, the connection points between valve and piping, and the connection points between elbow and piping need to be inspected continually.

  • PDF