• 제목/요약/키워드: Vertical Crack

검색결과 230건 처리시간 0.025초

압전 세라믹을 이용한 평판유리의 절단 거동에 관한 연구 (A Study on Cutting Behavior of Plate Glass Using a Piezoelectric Ceramics Actuator)

  • 이강원;제태진;최성대;정선환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.249-250
    • /
    • 2006
  • Recently FPD(Flat Panel Display) is used in various field to display enormous information. So cutting technique of flat panel display is needed for producing variety display merchandises. In present, cutting methods of flat panel glass includes breaking process. But this process occurs many glass particles. This glass particles are directly related badness of merchandise and falling productivity. In this paper, to cut front substrate glass of LCD and to get optimized cutting condition are tried fur eliminating breaking process with developed glass cutting machine using a Piezoelectric ceramics actuator. It is known that the vibration of Piezoelectric Ceramic have effect in crack proceeding through the analysis of fracture section.

  • PDF

(보물(寶物) 제2호(濟2號)) 보신각종(普信閣鐘)의 전파(傳播)크랙 및 응력(應力)레벨에 관(關)한 연구(硏究) (Study on Propagated Crack and Stress Level of Boshinkak Bell(No.2 Trensure))

  • 염영하
    • 비파괴검사학회지
    • /
    • 제5권1호
    • /
    • pp.9-23
    • /
    • 1985
  • Boshin-Kak Bell, which is one of the largest bells, is located at Chong-Ro Square in the center of Seoul. The bell has been struct early morning and late evening for time-report since the 14th century in Lee Era. Therefore Boshin-Kak Bell has been an intimate old friend of Seoul citizen more than 500 years. Unfortunately, motal large cracks were found inside this bell in the horizontal and vertical directions in 1979. The present paper has investigated the propagated bell-crack by ultrasonic flaw detecting method, and the stress level, bell vibration and weight measurement by electric wire resistance strain gauge method. The results indicate that they are useful for further study of Korean bell by nondestructive test.

  • PDF

반복하중을 받는 수직분할된 철근콘크리트 전단벽의 강성저감효과 (Stiffness Reduction Effect of Vertically Divided Reinforced Concrete Shear Walls Under Cyclic Loading)

  • 황보동선;손동희;배백일;최창식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권3호
    • /
    • pp.103-110
    • /
    • 2022
  • 본 연구의 목표는 수직분할된 철근콘크리트 전단벽의 철근상세에 따른 강성 및 강도 저감에 대해 실험적으로 평가하는 것이다. 본 연구에서는 수직분할에 따른 강도 및 강성 저감효과를 확인하기 위해 실 스케일 실험체 4개를 제작하여 반복 횡가력 실험을 수행하였다. 실험결과, 수직분할에 따라 강도 및 강성이 감소되는 것을 확인하였다. 특히 강도 저하율보다 강성 저하율이 큼에 따라 수직분할에 따른 하중 재분배 시 극한강도에 대한 안전성을 확보할 수 있을 것으로 기대된다. 균열양상을 확인한 결과, 분할된 벽체 중 압축지배를 받는 벽체에서 사인장 균열이 발생하였기 때문에 강도 평가 시 휨 강도 뿐만 아니라 전단저항 메커니즘을 같이 고려해야 한다. 벽체 단면 수직철근의 변형률 분포 분석 결과, 분할 후 두 개의 중립축이 발생하며 상부에서는 반전된 변형률 분포가 나타나 이중 곡률을 갖는 벽체의 양상을 보였다. 추후 연구에서는 벽체의 유효높이를 고려한 강성 저감률 평가가 필요하며 추가로 벽체 형상비 등 추가 변수에 대한 평가 및 유한요소해석을 이용한 다양한 벽체에 대한 해석적 연구가 필요하다.

마샬 안정도시험기를 이용한 아스팔트 혼합물의 파괴에너지 측정시스템 개발 (Development of Fracture Energy Measurement System of Asphalt Mixture Using Marshall Tester)

  • 김부일;이문섭
    • 한국도로학회논문집
    • /
    • 제11권1호
    • /
    • pp.135-144
    • /
    • 2009
  • 본 연구는 마샬 시험기를 이용하여 아스팔트 혼합물의 균열저항성을 평가할 수 있는 보다 간편하고 합리적인 측정시스템을 개발하는데 목적이 있다. 균열저항성 평가를 위한 파라메타로서 파괴에너지를 이용하였다. 마샬 시험기는 기본적으로 공시체 외부에 거치한 LVDT를 이용하여 수직변형률을 측정하는 시스템이며, 이 같은 외부 수직변형률 측정방식은 하중 스트랩 부분에서 발생하는 국부적인 변형으로 인해 측정오차를 야기할 가능성이 있다. 따라서 추가적인 계측 시스템을 설치하지 않고 기본적인 마샬 시험기를 이용하여 혼합물의 파괴에너지를 측정하기 위해서는 공시체 외부에 거치한 LVDT를 이용한 수직변형률 측정값이 파괴에너지 산정에 적용가능한지 여부를 검증하여야 한다. 이를 위해 본 연구에서는 공시체 중앙부분에서의 수평변형률과 외부에 거치한 LVDT를 이용한 수직변형률을 측정하는 두 가지 방식의 간접인장강도실험을 수행하여 그 차이를 비교 분석하였다. 실험결과, 외부 수직변형률 측정의 문제점으로 지적되었던 하중 스트랩 부분에서 발생하는 국부적인 변형은 파괴시점 이전에는 극히 적은 것으로 나타나 파괴에너지 계산에 오차를 유발하지 않음을 보여주었다. 또한 외부 수직변형률 측정의 실험변동성을 확인한 결과, 변동계수가 15% 이하로 마샬시험기를 이용한 균열저항성 평가시스템에 이용 가능함을 알 수 있었다.

  • PDF

강합성 콘크리트 박스구조물(트랜스퍼 거더)의 건조수축 균열에 대한 연구 (A Study on Shrinkage Crack of Steel Composite Concrete Box Structure (Transfer Girder))

  • 최정열;김대일
    • 문화기술의 융합
    • /
    • 제8권6호
    • /
    • pp.685-691
    • /
    • 2022
  • 본 연구의 대상구조물은 지하철 본선 직상부에 시공된 초고층 빌딩 하중을 지지하기 위해 설치한 전이구조체인 강합성 콘크리트 박스구조물(트랜스퍼 거더)로서 연구의 목적은 대상구조물에 발생된 균열의 원인을 분석하는 것이다. 본 연구에서는 강합성 콘크리트 구조물에 발생된 균열조사결과와 수치해석결과를 비교, 분석하여 강합성 콘크리트 구조물에 발생된 균열의 원인이 건조수축균열임을 해석적으로 입증하였다. 연구결과, 콘크리트 내부에 매립된 철골의 형상 및 수직보강재의 위치와 폐합 단면의 면적에 따라 외기온도에 따른 콘크리트와 강재간의 내부 온도차가 발생하는 것으로 나타났다. 수직보강재의 간격이 좁은 경우 넓은 단면에 비해 상대적으로 내부 온도의 집중도가 상승하여 외기와의 온도차가 크게 발생되는 것으로 나타났다. 또한 온도 및 온도에 따른 변형율이 크게 발생되는 위치와 현장균열조사 결과와 일치하는 것으로 분석되었다. 따라서 구조물 중앙부의 점검통로와 철골에 형성된 수직보강재 유무 및 간격에 따라 내부 온도 집중부가 형성되고 해당위치에서 강재에 의한 콘크리트의 온도신축거동이 구속되어 건조수축균열이 발생될 수 있는 것으로 분석되었다. 본 연구결과를 바탕으로 향후 강합성 콘크리트 구조물에 대한 유지관리 및 점검 시 건조수축에 의한 비구조적인 균열과 구조적인 균열을 구분하여 관리하는 것이 중요할 것으로 판단된다.

집중하중을 받는 철근콘크리트 깊은 보의 전단거동에 대한 실험적 연구 (An Experimental Study on the Shear Behavior of Reinforced Concrete Deep Beams Subject to Concentrated Loads)

  • 송우석;이진섭;양창현;김상식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.273-278
    • /
    • 1994
  • The shear behavior of simply supported reinforced concrete deep beams subject to concentrated loads has been scrutinized experimentally to verify the influence of the structural parameters such as shear span ratio, and the horizontal and vertical web reinforcements. A total of 27 specimens has been tested at the laboratory. In the tests all specimens have failed in shear causing inclined cracks from the load application points to the supports. The load bearing capacities have changed significantly depending on the shear span ratio. The effects of the vertical and horizontal reinforcements on the shear strength and crack initiation and propagation have been carefully checked and analyzed.

  • PDF

초고층 벽식 건축물의 수직부재 축소량 계측 및 보정 (A Study on The Compensation Method of Vertical Members of Tall Building)

  • 김우재;송화철;박효선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.404-407
    • /
    • 2004
  • The construction of high-rise buildings is increased. The Vertical Member of tall buildings is inherently shortened and it causes several seriously problems such as tilting of slab, crack within partition wall, deformation of curtain wall. This also affects structural stability by inducing unexpected stress to the structural members such as outrigger. In this study, the column shortening according to revised field information and to compare the analysis results the actual field measurement. Pusan The $\#$, a 51-story apartment building which is currently under construction was chosen for the case study.

  • PDF

심리스 튜브 제조공정 시 피어싱 플러그의 파손거동 (Failure Behavior of Piercing Plug during Seamless Tube Manufacturing Process)

  • 임영빈;윤정모
    • 열처리공학회지
    • /
    • 제30권5호
    • /
    • pp.207-214
    • /
    • 2017
  • In this study, failure behavior of piercing plug for seamless tube manufacturing process was studied. Three different kinds of passed piercing plugs (10, 90, 215 times) were prepared. The shape deformation of the passed piercing plugs was observed by 3D coordinate measuring machine, and the oxidized layer on the surface of piercing plug was observed by optical microscopy. The length reduction of piercing plug presented at 215 times passed plug. It was found that the oxidized layer consisted of outer scale, inner scale and internal oxidation layers, and the inner scale layer had vertical cracks, and interfaces had horizontal cracks. We proposed the failure mechanism of piercing plug during seamless tube manufacturing process based on the formation of vertical and horizontal crack.

Nonlinear shear strength of pre-stressed concrete beams

  • Rahai, Alireza;Shokoohfar, A.
    • Structural Engineering and Mechanics
    • /
    • 제41권4호
    • /
    • pp.441-458
    • /
    • 2012
  • The shear strength is an important factor in the design of prestressed concrete beams. Therefore, researchers have utilized various methods to determine the shear strength of these elements for the design purposes. To evaluate some of the proposed theoretical methods, numerous models of post-tensioned beams with or without vertical prestressing are selected and analyzed using the finite element method and assuming nonlinear behavior for the materials. In this regard the validity of modeling is evaluated based on some tests results. In the second part of the study two beam specimens are built and tested and their load-deformation curve and cracking pattern are studied. The analytical results consist of compressive strut slope and mid span load deflection are compared with some experimental results, and the results of some codes' formulas. Finally comparing the results of nonlinear analysis with the experimental values, a new formula is proposed for determining strut slopes in prestressed concrete beams.

철근콘크리트 프레임면내 조적벽체의 내진성능 평가 및 개선 (Evaluation and Improvement for Seismic Resistant Capacity of Reinforced Concrete Infilled Masonry Frame)

  • 신종학;하기주;최민권;전하석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.411-414
    • /
    • 1999
  • Five reinforced concrete rigid frame and masonry infilled wall and cut off type masonry infilled wall were constructed and tesed during vertical and cycle loads simultaneously. Experimental programs were accomplished to evaluate the structural performance of test spcimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. Test variables are hoop reinforcement ratio and masonry infilled wall with on without. All the specimens were modelling in one-third scale size.

  • PDF