• Title/Summary/Keyword: Verification of equipment

Search Result 508, Processing Time 0.031 seconds

Development and verification of a novel system for computed tomography scanner model construction in Monte Carlo simulations

  • Ying Liu;Ting Meng ;Haowei Zhang ;Qi Su;Hao Yan ;Heqing Lu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4244-4252
    • /
    • 2022
  • The accuracy of Monte Carlo (MC) simulations in estimating the computed tomography radiation dose is highly dependent on the accuracy of CT scanner model. A system was developed to observe the 3D model intuitively and to calculate the X-ray energy spectrum and the bowtie (BT) filter model more accurately in Monte Carlo N-particle (MCNP). Labview's built-in Open Graphics Library (OpenGL) was used to display basic surfaces, and constructive solid geometry (CSG) method was used to realize Boolean operations. The energy spectrum was calculated by simulating the process of electronic shooting and the BT filter model was accurately modeled based on the calculated shape curve. Physical data from a study was used as an example to illustrate the accuracy of the constructed model. RMSE between the simulation and the measurement results were 0.97% and 0.74% for two filters of different shapes. It can be seen from the comparison results that to obtain an accurate CT scanner model, physical measurements should be taken as the standard. The energy spectrum library should be established based on Monte Carlo simulations with modifiable input files. It is necessary to use the three-segment splicing modeling method to construct the bowtie filter model.

A Study on the Development of PD Simulation Pulse Generator for Evaluation of GIS Diagnosis System (GIS 진단시스템의 평가를 위한 PD 모의 펄스발생기 개발에 관한 연구)

  • Kim, Sungju;Chang, Sughun;Cho, Kook-hee
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.21-27
    • /
    • 2018
  • The expansion and stable operation of electric power facilities are important factors with development of industrial facilities in modern society. In high-voltage equipment such as GIS, the insulation characteristics may be deterioated by environment-friendly gas adaption and miniaturization. There is also the possibility of accidents due to insulation breakdown due to the deterioration of power facilities. Therefore, it is necessary to extend the diagnosis system to continuously monitor the danger signals of these power equipment and to prevent accidents. Most of the internal defects in the GIS system are conductive particles, floating electrode defects, protrusion defects, and the like. In this case, a partial discharge phenomenon is accompanied. These partial discharge signals occur irregularly and various noise signals are included in the field, so it is difficult to evaluate the reliability in the development of the diagnostic system. In this paper, a study was made on equipment capable of generating a partial discharge simulated signal that can be adjusted in size and frequency to be applied to a diagnostic device by electromagnetic wave detection method. The PD simulated pulse generator consists of a user interface module, a high-voltage charging module, a pulse forming circuit, a voltage sensor and an embedded controller. In order to simulate the partial discharge phenomenon similar to the actual GIS, a discharge cell was designed and fabricated. The application of the prototype pulse generator to the commercialized PD diagnosis module confirmed that it can be used to evaluate the performance of the diagnostic device. It can be used for the development of GIS diagnosis system and performance verification for reliability evaluation.

Effects of Ground Faults on the Safety of Persons and Low-voltage Installations in 22.9 kV-Y Distribution Systems (22.9 kV-Y 계통에서 지락고장이 인체 및 저압설비의 안전에 미치는 영향)

  • Kim, Han-Soo;Chung, Jae-Hee;Kang, Kae-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.141-148
    • /
    • 2008
  • This paper presents experimental results on the safety of persons and protection of low-voltage equipments of the sub-station due to a single-phase ground fault in 22.9 kV-Y distribution system. In order to evaluate the hazard voltages and the stress voltage of the low-voltage(LV) equipment due to faults between high-voltage systems and earth based on the newly prescribed KS C IEC 60364 standard series, the verification tests in a 22.9[kV] neutral multiple grounding system were carried out. From the experimental results, we introduce serious problems causing some discomfort when applying KS C IEC 60364 standard series to the existing domestic distribution system and the effective protective measures against temporary overvoltages due to a ground fault in the common grounding which is combined the 22.9 kV-Y grounding and the customer's installation grounding are proposed. As a consequence, it was found that the equipotential bonding is an important prerequisite for the effectiveness of the protective measures for the safety of persons and LV equipment in the combined 22.9 kV-Y and low-voltage grounding system.

Scenario Based Operating Satellite Payload Data Analysis Method to Secure Highly Reliable EGSE Early (고신뢰성 지상시험지원장비 조기 확보를 위한 시나리오 기반 위성 탑재체 패킷 분석방법)

  • Lee, Jong-Tae;Lee, Ki-Jun
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_1
    • /
    • pp.521-535
    • /
    • 2017
  • Since satellites, including payloads, are limited in how they can respond to problems after launch, the functionality of the satellite should be verified sufficiently by EGSE (Electrical Ground Support Equipment). In addition, considering the trend that the development period of the satellite is shortening and the development of the EGSE must precede the development of the engineering model of electronic equipment, early securing of EGSE is necessary to comply with the development schedule of the entire satellite. In this paper, we propose a method for early securing highly reliable EGSE by devising a scenario based operating payload packet analyzer, which is a part of the EGSE, through functional modularization and external parameterization, and show the result of applying the implemented payload packet analyzer to real satellite program.

Experimental verification and improvement of heat transfer tube local wall temperature measurement method

  • Jiabao Liu;Xiaxin Cao;Peixun Yang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4317-4328
    • /
    • 2023
  • To ensure the measuring accuracy of the wall temperature, the outer wall temperature measurement values by using three kinds of thermocouple welding methods were analyzed and evaluated in the paper, including single-point flush-mounted in the wall groove method, single-point insert-mounted in the wall groove, and outer surface direct welding method, based on the application of a tube-in-tube condensing heat exchanger. And the impacts of silver, tin, and thermal resistance adhesive as filling materials on wall temperature measurement were also investigated, and the results were compared to that obtained without filling materials. The results showed that the wall temperatures measured by the three welding methods were lower than the theoretically calculated value. And the wall temperature measured by the outer surface direct welding method was lowest under the same experimental conditions. The wall temperatures measured by single-point flush-mounted and insert-mounted in the wall groove methods were also affected by different welding filling materials. It was found that the greater the thermal resistance of filling materials, the smaller the heat loss. By analyzing the reasons for the low measured value of wall temperature, a new wall temperature measurement method was developed to improve the accuracy of the current measurement method. Meanwhile, the outer wall temperature measurement experiments of vertical and horizontal heat transfer tubes were carried out to validate and calibrate the improved outer wall temperature measurement method. The results showed that the average outer wall temperature deviation measured by the improved wall temperature measurement method ranged from - 0.82% to +2.29% for vertical tubes and - 4.75% to - 1.44% for horizontal tubes, and the improved measurement method had good measurement accuracy.

Experimental Verification of Heat Sink for FPGA Thermal Control (FPGA 열제어용 히트싱크 효과의 실험적 검증)

  • Park, Jin-Han;Kim, Hyeon-Soo;Ko, Hyun-Suk;Jin, Bong-Cheol;Seo, Hak-Keum
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.9
    • /
    • pp.789-794
    • /
    • 2014
  • The FPGA is used to the high speed digital satellite communication on the Digital Signal Process Unit of the next generation GEO communication satellite. The high capacity FPGA has the high power dissipation and it is difficult to satisfy the derating requirement of temperature. This matter is the major factor to degrade the equipment life and reliability. The thermal control at the equipment level has been worked through thermal conduction in the space environment. The FPGA of CCGA or BGA package type was mounted on printed circuit board, but the PCB has low efficient to the thermal control. For the FPGA heat dissipation, the heat sink was applied between part lid and housing of equipment and the performance of heat sink was confirmed via thermal vacuum test under the condition of space qualification level. The FPGA of high power dissipation has been difficult to apply for space application, but FPGA with heat sink could be used to space application with the derating temperature margin.

An Application of the Genetic Algorithm for the Input Shaper on the High Order System (입력 성형기의 고차 시스템 적용을 위한 GA활용)

  • Jeong, Hwang Hun;Yun, So Nam;Lee, Sang Hun
    • Journal of Drive and Control
    • /
    • v.17 no.2
    • /
    • pp.1-8
    • /
    • 2020
  • Recently, industrial systems are becoming quicker and lighter to enable the reduction of energy consumption and increase productivity. So the latest systems are more flexible and rapid than the previous systems. But, with this improvement, another problem has emerged, such as the increase in residual vibration when a system is started or stopped. The input shaper is a command generation method that can remove residual vibration. It can provide a solution to the problem of residual vibration in industrial systems. However, it is difficult to generate the input shaper in high order systems, such as a typical industrial system because the input shaper is induced from the system's vibration characteristics. This study focused on the extra insensitivity shaper that can compensate for the system's modeling error such as input dynamics, and the high order's system affection. A genetic algorithm was deployed to adjust a vibration limitation for the extra insensitivity of the input shaper. A plant is a low damping system that includes one zero and a pole. The fitness functions are an error signal of the system's response with normalized frequency variations. Verification of the suggested system is satisfied by comparison between the zero vibration derivative input shaper's response and the suggested one.

Development of Test Equipment for KSLV-I Upper Stage (KSLV-I 상단부 시험장비(UTE) 설계 및 개발)

  • Kim, Kwang-Soo;Lee, Soo-Jin;Chung, Eui-Seung;Park, Jeong-Joo
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.171-179
    • /
    • 2007
  • The Test Equipment for the upper stage of KSLV-I has following functions via umbilical cable interface; external power supply, command output such as discrete and analog, data acquisition, CS-I interface simulation for first stage of KSLV-I and RS-422 serial communication for PDU. The main purpose of UTE is the experiment or function verification of system-level upper stage. To realize this system, we used PXI control system. The UTE is consisted of the PXI control system, power supply, terminal block, internal harness, connector panel and so on. The software functions of UTE are classified by four blocks. These are Discrete/Analog I/O control, PDU RS-422 serial communication control, power supply GPIB control and UTE remote control. In this paper, we will describe the design on the hardware and software of UTE.

  • PDF

A Study on the Analysis of Mission Reliability in the Combat System through SysML (SysML설계기법을 통한 전투체계 임무신뢰도 분석연구)

  • Lee, Jeong-Wan;Jang, Joong Soon
    • Journal of the Korea Society for Simulation
    • /
    • v.29 no.1
    • /
    • pp.31-38
    • /
    • 2020
  • Mission reliability is defined by the probability of accomplishing the requirements task that were targeted in product development, and in the case of combat systems, mission reliability is an important factor that will determine victory or defeat, unlike commercial equipment. The mission reliability of the existing domestic combat system was calculated by considering only the physical connections of the equipment involved in the mission performance, but as the equipment becomes increasingly sophisticated and complex, it is impossible to determine the mission relevance solely by physical connection. Thus, in this paper, improved mission reliability was calculated using SysML, the system design modeling language, by taking into account the functional connection as well as physical connection. Based on this research, we look forward that the mission reliability of the combat system that will be developed in the future will be used as a verification material.

Design of Test Configuration and Analysis of Electrical Integration Result between GEO Satellite Solar Array and Bus (정지궤도위성용 태양전지판 전기적 접속시험 형상 설계 및 시험 결과 분석)

  • Kim, Young-Yun;Kwon, Jae-Wook;Youn, Young-Su;Choi, Jong-Yeoun
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.22-30
    • /
    • 2010
  • KARI had integrated and tested GEO satellite in cooperation with Astrium Inc., France. In the middle of integration and test, It was necessary to check GEO satellite SA(solar array) status and require electrical interface verification with bus. SA of GEO satellite have different mechanical characteristics in comparison with those of LEO satellite which was tested in KARI. LEO SA has been deployed by simple mechanical hinge system but GEO SA has been done by more complicated method. so in this paper, we designed the test configuration and analyzed the test result of solar array electrical integration of GEO satellite.