공기청정기와 가습기의 소음특성 (Noise Characteristics of Air Cleaners and Humidifiers)

  • 김용희;박지훈
    • 한국소음진동공학회논문집
    • /
    • 제26권1호
    • /
    • pp.20-26
    • /
    • 2016
  • This study investigated noise characteristics of air cleaners and humidifiers in terms of frequency domains and measurement directions. Noise levels of 31 air cleaners and 36 humidifiers were measured in an anechoic chamber according to the related group standards. As for air cleaners, 5 receiving points of 1 m off from front, rear, left, right and top surfaces of the product were considered. In case of humidifiers, 4 receiving points without the rear position were considered in the same manner as air cleaners. In each case, A-weighted equivalent continuous sound level was measured three times for 1 min. As a results, most of the measured air cleaners and humidifiers showed the highest noise levels at top directions due to the air ventilating location. In case of air cleaners, averaged noise levels of top and rear positions were 49.9 and 48.2 dB(A), respectively, whereas averaged noise level of other positions was all 45.2 dB(A). In case of humidifiers, averaged noise level of top position was 44.1 dB(A) whereas averaged noise levels of other positions were 38.7 to 39.1 dB(A). In addition, high frequency content of 1 kHz and 3.15 kHz to 4 kHz for air cleaners and middle frequency content of 500 Hz to 1.6 kHz for humidifiers showed significant contribution to determination of overall noise levels with correlation coefficient of 0.9 and above.

LCC 기법을 이용한 신기술 냉 $\cdot$ 난방 공조설비 시스템의 경제성 분석에 관한 사례연구 (A Case Study on the Economic Analysis for an Advanced Technology-Based HYAC System Using LCC Technique)

  • 김용수;황성수
    • 한국건설관리학회논문집
    • /
    • 제6권2호
    • /
    • pp.129-138
    • /
    • 2005
  • 본 연구는 LCC 기법을 이용한 냉 $\cdot$ 난방 공조설비 시스템에 대하여 사업 실행전 LCC와 사업 실행후 LCC를 예측, 성과측정 및 경제성 평가를 목적으로 진행되었다. 이를 위해 신기술 냉 $\cdot$난방 공조설비 시스템의 Life Cycle동안의 비용자료를 실적자료와 견적자료, 인터뷰등의 방법으로 조사 $\cdot$ 분석하였다. 또한 분석기간 15년 동안의 사업 실행전 $\cdot$ 후의 LCC를 예측하여 성과측정 및 경제성 평가를 실시하였다. 이와 같은 과정을 통해 수행된 본 연구의 결과는 다음과 같다: 1)일체형 개별냉 $\cdot$난방공조설비의 설치로 인해 할인비용시 $21.6\%$의 경제성이 있는 것으로 분석되었다. 3)성과측정은 투자대비 회수배율로서 할인비용시 회수배율은 신축의 경우 4.8배, 리모델링의 경우 14.4배의 경제성이 있는 것으로 분석되었다.

가스폭발 사고와 관련된 국가배상 사례의 분석 (Analysis of A Gas Explosion-Related State Compensation Case)

  • 이의평
    • 한국재난정보학회 논문집
    • /
    • 제16권1호
    • /
    • pp.44-59
    • /
    • 2020
  • 이 논문에서는 2층 건물 지하층의 다방에서 가스냄새가 난다고 119신고가 되어 소방대원들이 출동하여 옥상에 있는 LPG 가스통들의 밸브를 직접 잠그고 지하층 다방의 중간밸브의 잠금 상태를 확인하고 현장에 도착한 가스공급 및 설치 업자에게 안전조치를 취하도록 요구하고 철수한 후 7분 만에 가스폭발사고가 발생하여 2명이 사망하고 21명이 부상을 입은 사례를 분석하고 있다. 법원은 가스폭발사고의 원인이 규명되지 아니하였으므로 가스공급 및 설치 업자와 한국가스안전공사에 배상 책임을 물을 수 없고 안전조치를 하지 않고 철수한 소방기관에게만 배상책임이 있다고 판결하였다. 그러므로 가스가 누설된다고 119신고가 되는 경우에 출동한 소방대는 가스 밸브를 잠그고 사람들을 대피시키거나 접근하지 못하게 하고 환기를 시키는 등 안전조치를 하고 화재나 폭발가능성이 없음을 확인한 후 철수해야 한다.

겨울철 냉기를 이용한 벼의 저온저장(I) - 벼 냉각 후 저장특성 - (Low Temperature Storage of Rough Rice Using Cold-Air in Winter(I) - Storage Characteristics after Rough Rice Cooling -)

  • 이재석;한충수;함택모;연광석
    • Journal of Biosystems Engineering
    • /
    • 제30권3호
    • /
    • pp.155-160
    • /
    • 2005
  • The objective of this research was to establish a domestically available cooling storage technique by cold-air in winter, using winter cool air ventilation fur determining rough rice cooling method in the storage and dry bin. The rough rice storage characteristics of two test conditions, winter cool-air ventilation storage and ambient temperature storage, were evaluated from January to July 2001, using a storage and dry bin of 300-ton capacity. Results of this research are as follows: Grain temperature was from $-5.1\~-8.5^{\circ}C$ after winter cool-air ventilation, and grain initial temperature for ambient temperature bin storage was $0.3\~1.9^{\circ}C$. Moisture content of rough rice decreased from $0.28\;to\;0.93\%$ and from $1.53\;to\;1.92\%$ to compare with original moisture contents for winter cool-air ventilation, and for ambient temperature bin storage, respectively. Broken ratio of brown rice from winter cool-air ventilation bin increased from $0.16\;to\; 0.92\%$, and brown rice broken ratio was from $2.24\;to\;2.86\%$ for ambient temperature bin storage to compare with initial broken ratio. Hardness of stored rice increased along storage period increase in alt storage methods, and cooling bin storage increased rice hardness of 0.271kgf: this increasing was lower then the other methods from 0.059 to 2.239kgf. Germination rates were decreased approximately 9.03, 3.14 and $3.20\%$ for upper, middle, and bottom of ventilating winter air bin, respectively, and germination rates of 2.70, 3.47 and $4.14\%$ were approximately decreased for upper, middle, and bottom parts of ambient temperature bin storage, respectively.

원심력 필터 재생기능을 갖춘 오일 미스트 여과 집진장치 개발 (Development of an Oil Mist Collector Equipped with Centrifugal De-oiling System)

  • 김태형;서정윤;하현철;김종철;조진호
    • 한국산업보건학회지
    • /
    • 제15권3호
    • /
    • pp.166-175
    • /
    • 2005
  • Health effects associated with metal working fluid (MWF) exposures include dermatitis, respiratory disease, hypersensitive pneumonitis, and asthma. Frequently, occupational exposures to MWFs are controlled by ventilating an enclosure with an air cleaning unit that includes a fan preceded by various kinds of filtration. There are several kinds of air cleaning units used in machining centers. But the associated troubles have hindered from efficiently using these devices. The main problem is the relatively short period of filter replacement. The reason is that the air cleaning units usually do not have the de-oiling systems, thus leading the earlier clogging of filters and reducing the flow rate of hood. Thus, the first stage of study was conducted to overcome this problem by developing the new oil mist collector equipped with the easy de-oiling system. The principle of de-oiling is that the centrifugal force generated by spinning the drum covered by filter fabric separates oils from the filter fabric. It would be very similar to the spin-dry laundry. By adopting this de-oiling technique, the problems associated with the conventional oil mist collectors could be solved. Several tests/analyses were performed to make the lab-scale oil mist collector. The collection efficiencies and the de-oiling efficiencies of commercially available filter fabrics were tested. Subsequently, the endurance test were conducted by observing SEM photos of filter fabrics and measuring tensile strength/expansion coefficient after spinning the filter drum for 20 minutes at the different rotation speeds. By doing these experiments, the most appropriate filter fabric and rotation speed/duration were selected. Finally, the new oil mist collector was designed. In the near future, this device must be tested in the real machining center.

도우미의 유니폼 착용실태 조사 - 내레이터 모델을 중심으로 - (A Research on the Actual Condition of Narrator Models' Wearing Uniform)

  • 정혜영;이명희
    • 한국의류산업학회지
    • /
    • 제6권6호
    • /
    • pp.707-714
    • /
    • 2004
  • This study was carried out to research the actual condition of narrator models' wearing uniform, targeting on the narrator models who are being currently active and are from 19-year-old to 30-year-old. A poll was performed through visiting internet circles and spots, and the characteristic of objects, the form of uniform, attitude on uniform, dissatisfaction index on wearing uniform and preference index on wearing uniform were researched. It was carried out from August 18, 2003 to August 31, 2003. In order to perform this study, 161 questionnaires were used in all, and frequency analysis was implemented using SPSS 10.0. The objects of study were composed of female. Those who are from 21-year-old to 25-year-old accounted for 74.5%, and those who have career from 2 years to 3 years accounted for 75.5%. In respect to attitude on wearing uniform, affirmative answers, affirmative answers, such as a sense of belonging, a pride in activity and increase of efficiency, accounted for 68.8%. On the other hand, in respect to a harmonization between uniform and work, just the 39.8-percent showed affirmative reaction. Concerning the functionality of uniform, such as retaining warmth and ventilating, dissatisfaction index showed very high value; it is judged that it should be improved henceforth. Working postures were researched, following the order of standing posture and arm-using posture. In inconvenient actions, bending down and moving arms were orderly pointed out. With regard to the dissatisfaction of size, busts, the length of skirt and waist girth were orderly pointed out. Likewise, considering the parts of which room is required, bust, hip girth and waist girth were orderly pointed out. As to the points that should be bettered, design and functionality were orderly pointed out. In respect to materials of uniform, sweat-absorption material, light material and well-ventilated material were orderly suggested.

차륜형 대공포의 냉방기 최적화 설계 (Optimized Design of Air Controlling System in Air Defense Gun Systems of Wheeled Vehicle)

  • 전기현;이부환;이동희
    • 대한기계학회논문집B
    • /
    • 제37권11호
    • /
    • pp.1047-1051
    • /
    • 2013
  • 최신의 전투장갑차들은 통합형 공조장치를 선호하는 경향이 있음에도 불구하고 분리형 공조장치에 대한 필요성이 제기되고 있다. 본 연구에서는 특수목적용 장갑차량 및 군용규격이 요구되는 장갑차량의 냉방, 난방장치에 대한 연구로 상용 Fluent 를 이용한 유동해석을 통해 덕트 및 최적화 배치를 구현하였으며 실차을 통한 시험 수행으로 해석결과를 검증하고, 선정된 냉방 및 난방기의 유효성을 확인하였다. 기존 차량의 변경 모델이나 계열차량의 경우, 현재 선정된 모델의 부분 변경으로 가능하며, 차륜형 장갑차용으로 선정된 현재 모델의 유효성을 본 연구를 통해서 입증되었다.

버어리종 건조시 급건엽발생방지에 관한 연구 III. 환기조건이 급건엽발생에 미치는 영향 (Studies on the Prevention of Excessive Drying Leaves during Burley Tobacco Curing III. Effect of the Ventilating Conditions on the Occurrence of Excessive Curing Leaves)

  • 배성국
    • 한국작물학회지
    • /
    • 제32권2호
    • /
    • pp.130-136
    • /
    • 1987
  • 공시품종인 Burley 21을 수확한 후 건조하고 무더운 시기에 처리하여 건조하우스의 환기시기, 환기량 및 달줄간격 등의 건조실관리에 따른 급건조방지 방법을 밝히고자 시험한 결과 요약하면 다음과 같다. 1. 건기에는 건조시 시종환기구에서 온도가 낮았고 급건엽발생도 제일 적었다. 2. 급건엽발생시기는 황변말부터 갈변말까지로 이 시기에 탈수를 지연시키는 것이 가장 중요하다. 3. 급건엽발생이 적을수록 품질 및 물리성이 양호하였다. 4. 측면을 1.5m로 충분히 환기시킨 구에서 급건엽발생이 가장 적었다. 5. 달줄간격을 좁힐수록 온도에는 크게 영향을 미치지 않았으나 온도는 높게 유지하여 급건엽발생을 크게 감소시켰다. 6. 급건엽의 내용성분은 충분히 분해가 일어나지 않았다.

  • PDF

무창분만돈사의 온.습도 환경 분석 (Environmental Analysis of a Windowless Delivery Swine Building : Temperature and Relative Humidity)

  • 이성현;조한근;장유섭
    • 한국축산시설환경학회지
    • /
    • 제3권2호
    • /
    • pp.77-85
    • /
    • 1997
  • Recently, local swine producers are rapidly adopting the indoor production system which developed in foreign countries. However, this imported system is reported as not functioning properly because of different climate conditions. The objective of this project was to investigate the environment characteristics of a windowless delivery swine building. The parameters studied were the heating and cooling loads, the daily changes of indoor temperature and relative humidity, the horizontal and the vertical distributions of indoor temperature, and the effect of mist cooling on indoor temperature. From this study, the following are founded : 1. The maximum cooling and heating loads were - 317.0kcal/㎡$.$h and 336.5kal/㎡$.$h in summer and in winter. The large loads seems to be on account of inappropriate operations of ventilating fans. 2. The daily variations of relative humidity in indoor were smaller than those in outside. Those values both in summer and in winter as relative humidities in door was lower than optimum for growing pigs, the additional humidifier might be helpful to increase the relative humidity in indoor. 3. The horizontal distribution of the indoor temperature was found to be uniform in the variation range of 1$^{\circ}C$. 4. The vertical distribution of the indoor temperature was not found to be uniform; the temperature of upper part was higher than that of slot part. 5. Average values of indoor temperature became lower by 3$^{\circ}C$ by mist cooling. But the variation of temperature was found to be larger; The middle part of the room was cooled down, but the corner part of the room was not affected by misting due to uneven nozzle configuration.

건축물 실내 공기질 향상을 위한 광촉매 코팅 효과에 관한 연구 (A Study on the Effect of Photocatalyst Coating to Improve the Indoor Air Quality in Buildings)

  • 박현구;김종호;고성석
    • 한국안전학회지
    • /
    • 제21권2호
    • /
    • pp.150-157
    • /
    • 2006
  • 새건물증후군이란 새로 지은 건물에서 생활하는 사람들에게 눈이 따갑거나 목이나 코가 아프거나, 두통, 구토, 피부발진 등 증상이 나타나는 것을 일컫는 말이다. 새집증후군 원인물질의 주요 성분으로는 건축 자재나 벽지, 페인트, 가구 접착제 등에서 발생되는 포름알데이드(HCHO)와 톨루엔 등 휘발성 유기화합물(VOCs: Volatile Oragnic Compounds), 부유 박테리아, 곰팡이, 바이러스 등이다. 새집증후군을 저감하기 위한 방법으로는 환기에 의한 방법, 오염물질이 없는 친환경 재료의 사용 및 재료의 처리를 통해 오염물질을 저감하고자 제거하는 방법이 있다. 본 연구는 이들 방법 중 건축 재료 위에 표면코팅처리를 함으로써 실내 공기질을 향상시키기 위한 것으로, 건물 내 표면 코팅 전후의 공기질을 분석함으로써 실내 거주환경을 안전하게 조성하는 데 그 목적이 있다.