• Title/Summary/Keyword: Value Measurement

Search Result 4,755, Processing Time 0.041 seconds

A Comparative Study of a Variable Overlap-area Type and Conventional Types in the Inductive Precision Position Measurement System (자속경로 단면적 및 공극변화를 이용한 인던턴스형 초정밀 변위측정 시스템)

  • Choe, Dong-Jun;Choe, In-Muk;Kim, Su-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.2
    • /
    • pp.254-259
    • /
    • 2002
  • A variable air-gap type system is widely used for inductive precision position measurement systems. This type transducer has high sensitivity but lacks a linear measurement range due to structural nonlinearity. Furthermore, as measurement range increases, linearity error is also increased. The alternative is a variable overlap-area type system. The sensitivity of this type is determined by the initial air-gap dimension, keeps the original value and does not deteriorate linearity in spite of the variations of the measuring range.

The shape measurement of three-dimensional object by using color-coded information (색정보를 이용한 3차원 형상 측정)

  • Kim J.S.;Song C.K.;Joo B.K.;HONG J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1446-1449
    • /
    • 2005
  • The purpose of this study is the real-time shape measurement of three-dimensional object by using color coded information. The paper relates to non-contact optical measurements of surface profiles or displacements, because of optical measurement systems are advantageous over using mechanical sensing, their relatively high speed and non-destructive capabilities. Therefore is particularly useful for three dimensional sensing which requires high horizontal and vertical resolution of measurements over a wide range thereof. Each a red, blue, green by using a inherence colors of hue value are good point.

  • PDF

Design of On-line Process Control with Variable Measurement Interval

  • Park, Changsoon
    • Journal of the Korean Statistical Society
    • /
    • v.29 no.3
    • /
    • pp.319-336
    • /
    • 2000
  • A mixed model with a white noise process and an IMA(0,1,1) process is considered as a process model. It is assumed that the process is a white noise in the absence of a special cause and the process changes to an IMA(0,1,1) due to a special cause. One useful scheme in measuring the process level is to use the variable measurement interval (VMI) between measurement times according to the value of the previous chart statistic. The advantage of the VMI scheme is to measure the process level infrequently when in control to save the measurement cost and to measure frequently when out of control to save the off-target cost. This paper considers the VMI scheme in order to detect changes in the process model from a white noise to an IMA(0,1,1). The VMI scheme is shown to be effective compared to the standard fixed measurement interval (FMI) scheme in both statistical and economic contexts.

  • PDF

Measurement Uncertainty Analysis of Positioning Accuracy for High Precision Feed Mechanism (고정밀 이송기구의 위치결정정밀도에 대한 측정불확도 요소 분석)

  • Lee, Jung-Hoon;Yoon, Sang-Hwan;Park, Min-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.5
    • /
    • pp.494-499
    • /
    • 2012
  • Reliable results can't be derived without the notion of measurement uncertainty. The reason is that the measured value includes a lot of uncertain factors. Finding the factor that affect the measurement of parameter is important for estimation of measurement uncertainty. In this paper, the evaluation of uncertainty analysis about positioning accuracy measurements of high precision feed mechanism is presented to evaluate the important factors of uncertainty.

A Development of Recoil & Counter Recoil Motion Measurement System Using LVDT

  • Park, Ju-Ho;Hong, Sung-Soo;Joon Lyou
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.2 no.3
    • /
    • pp.214-219
    • /
    • 2000
  • This paper presents a recoil and counter recoil motion measurement system using linear variable differential transformers (LVDT). The output of the LVDT is obtained from the differential voltage of the secondary transformers. Since a transducer core is attached to the motion body, the output is directly proportional to the movement length of the core. Displacement, velocity and acceleration are measured from the LVDT. With a comparison between the measurement result and the reference value obtained by the highly accurate Vernier calipers, it is proved that the measurement system with the LVDT is applicable to the test of the moving part of the mechanism with better accuracy.

  • PDF

Reappraisal of Compressibility Properties of Nakdong River Estuarine Clays from field Measurement (계측사례를 통한 낙동강 하구 점토의 압축특성 재평가)

  • Lee, Kang-Woon;Ryu, Il-Hyoung;Park, Taek-Gyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1013-1022
    • /
    • 2005
  • Because depth of deposit is deeper as well as compressibility is very larger than the other regions in Korea, behaviour of settlement at Nak-Dong river estuarine causes hot issue at ground improvement. Defined properties for design differ from measurement. Therefore it affects cost of construction. This study presents design standard to engineers as it defined properties of compressibility at Jangyu Area of Nak-Dong river estuarine. To search value of representation for region, back analysis was performed using the measurement. To verify that, the measurement of recently designed site was confirmed, and the cost of construction with properties of consolidation was calculated.

  • PDF

A New Method for Sampling Inspection by Variables under Undesired Measurement Conditions (불확실한 계측 조건하에 변수에 의한 샘플링 검사를 위한 새로운 방법)

  • 김일수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.187-193
    • /
    • 1996
  • This paper presents a new approach to modify the traditional method for sampling inspectionby variables to suit undesired measurement conditions. On the basis of a systematic analysis of the effects of measurement errors on different types of acceptance schemes this paper gives two modified equations for revising the sampling size η and the acceptability constant $textsc{k}$ to form a new acceptance scheme (η'$textsc{k}$) under undesired measurement conditions. It has proved that the new method is suitable to different types of sampling inspection by variables including that for mean value and that for percent defective. The new acceptance scheme based on the proposed technique provides an engineering feasibility to replace the traditional scheme to suit undesired measurement conditions.

  • PDF

A Study on Machined Surfaces Characteristics of Aluminum Alloy by AFM Measurement (AFM 측정법에 의한 알루미늄 합금의 초정밀 가공면 평가 연구)

  • Lee Gab-Jo;Kim Jong-Kwan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.2
    • /
    • pp.81-86
    • /
    • 2006
  • The machining parts must be produced within the specification of drawing and those will be able to meet function and efficiency. At that time, it is very important not only precision machine and machining technique but also the measurement technique. So, the improvement of measurement technique is to be joined together at once with improvement of machining technique. Finally, the quality and value of the parts are decided by precision measurement. This paper aims to study on the machined surfaces characteristics of aluminum alloy by AFM(Atomic force microscope) measurement. The objective is contribution to ultra-precision machining by exhibit foundation data of surface roughness and tool wear when parts are cutting with diamond tool at the factory.

QoS Measurement Method of RTP/RTCP for Multimedia Service in BcN (BcN에서 멀티미디어 서비스를 위한 RTP/RTCP의 QoS 측정방법)

  • Lim Jae-Young;Kim Jeong-Ho
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2005.11a
    • /
    • pp.611-615
    • /
    • 2005
  • Having been multimedia services in BcN network, QoS is best important factor. This paper classify existing services and newly to be offered services, analyze quality criterion and measurement method for QoS guarantee in BcN, This paper investigate end-to-end quality criterion, classify measurement method existing and newly to be offered services, search quality criterion, introduce measurement method such as call success rate, packet loss rate, one-way delay, jitter and R-value for end-to-end quality measurement.

  • PDF

A Study on the Measurement Method and Uncertainty Factors for Precision Inspection to Feed Unit of High Precision Machine Tool (고정밀 공작기계 이송장치의 정밀도 측정방법 및 불확도 요인에 관한 연구)

  • Kim, Sang-Hwa;Kim, Byung-Ha;Choi, Woo-Gak
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.55-61
    • /
    • 2012
  • Very important content in performance evaluation of machine tool is positioning accuracy and repeatability precision measurements of feed mechanism. A study analyses the measurement method and uncertainty factors by ISO-based test method. Reliable results can't be derived without the notion of measurement uncertainty. The reason is that the measured value includes a lot of uncertain factors. Finding the factor that affects the measurement of parameter is important for estimation of measurement precision. In this paper, the evaluation of uncertainty analysis about positioning accuracy and repeatability precision measurements of high precision feed mechanism is presented to evaluate the important factors of uncertainty.