• 제목/요약/키워드: VSI-PWM Inverter

검색결과 66건 처리시간 0.025초

An On-Line Harmonic Elimination Pulse Width Modulation Scheme for Voltage Source Inverter

  • Salam, Zainal
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.43-50
    • /
    • 2010
  • This paper proposes a new harmonic elimination PWM (HEPWM) scheme for voltage source inverters (VSI) based on the curve fittings of certain polynomials functions. The resulting equations to calculate the switching angle of the HEPWM require only the addition and multiplication processes; therefore any number of harmonics to be eliminated and the fundamental amplitude of the pole switching waveform (NP1) can be controlled on-line. An extensive angle error analysis is carried out to determine the accuracy of the algorithm in comparison to the exact solution. To verify the workability of the technique, an experimental single phase VSI is constructed. The algorithm is implemented on a VSI using a 16-bit microprocessor. The results obtained from the test rig are compared to the theoretical prediction and the results of the MATLAB simulations.

인버터 폴트 (B4) 환경 하에 토크리플 절감을 위한 개선된 변조방식 (Improved PWM for reducing torque ripple in PMSM with B4 inverter)

  • 박진식;정신명;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.292-294
    • /
    • 2006
  • This paper presents a study on the use of improved space-vector modulation of VSI employing only four switches, four body diodes. Different switching sequence strategy for vector control for inverter fault mode are described. The influence of different switching patterns at same modulation index and improved PWM method is proposed. The proposed PWM is compared with conventional PWM. Simulation and experimental results are presented.

  • PDF

영구자석 동기전동기 구동을 위한 전압원 인버터의 적응제어기법을 이용한 전압 왜곡 관측 및 보상 (Observation and Compensation of Voltage Distortion of PWM VSI for PMSM using Adaptive Control Method)

  • 김학원;윤명중;김현수;조관열
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.406-410
    • /
    • 2004
  • Generally, a voltage difference exists between the reference and the output voltagesin a pulse width modulated (PWM) voltage source inverter (VSI). In this paper, the nonlinearity in a PWM VSI is analyzed and a new on-line estimation method in consideration of parameter variations for a permanent magnet synchronous motor (PMSM) is proposed to compensate the time varying voltage distortion.

  • PDF

정지좌표계를 이용한 3상 UPS용 PWM-VSI 제어 (PWM-VSI controller of Three-phase UPS Using Stationary Reference Frame)

  • 김민규;김재식;방상석;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.965-968
    • /
    • 2003
  • This paper describes the PWM-VSI controller of three-phase UPS system using stationary reference frame. This controller meets the specification the UPS inverter output voltage even under the unbalanced or nonlinear load. This controller is also constructed with duble control loop of the outer voltage control loop and the inner current control loop. For the fast response of the output voltage control, yhr inner current control loop of the capacitor current os used. To get the good property against overshoot, the If controller us used. The outer voltage controller is designed with P controller and the high gain transfer function is used for the zero steady state error. All control gains of both controller is designed base on the CDM method.

  • PDF

Compensation PWM Technique for Extended Output Voltage Range in Three-Phase VSI Using Three Shunt Resistors

  • Shin, Seung-Min;Park, Rae-Kwan;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1324-1331
    • /
    • 2014
  • This paper proposes a compensation PWM technique for the extension of output voltage ranges in three-phase VSI applications using three shunt resistors. The proposed technique aims to solve the dead zone, which occurs in high modulation indexes. In the dead zone, two phase currents cannot be sampled correctly, so that the three-phase VSI cannot be operated up to the maximum output voltage. The dead zone is analyzed in detail, and the compensation PWM algorithm is developed. The proposed algorithm is verified by numerical analysis and experimental results.

Optimum Hybrid SVPWM Technique for Three-level Inverter on the Basis of Minimum RMS Flux Ripple

  • Nair, Meenu D.;Biswas, Jayanta;Vivek, G.;Barai, Mukti
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.413-430
    • /
    • 2019
  • This paper presents an optimum hybrid SVPWM technique for three-level voltage source inverters (VSIs). The proposed hybrid SVPWM technique aims to minimize total harmonic distortion (THD). A new parameter is introduced to incorporate the heterogeneous nature of switching sequences of SVPWM technique. The proposed hybrid SVPWM technique is implemented on a low-cost PIC microcontroller (PIC18F452) and verified experimentally with a 2 KVA three-phase three-level insulated gate bipolar transistor-based VSI. Optimum switching sequence results in the three-level inverter configuration are demonstrated. The proposed hybrid SVPWM technique improves the THD performance by 17.3% compared with the best available three-level SVPWM technique.

비용절감형 컨버터 구조를 갖는 3상-3상 PWM 정류기/인버터 시스템 (Novel Converter Topology for a Three Phase to Three Phase PWM Rectifier/Inverter System)

  • 김기택;박태열;이해춘
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.323-328
    • /
    • 1998
  • A current controlled VSI-PWM rectifier and inverter with capacitor dc link is regarded as one of the most promising structures for three-phase to three-phase to three-phase power conversion. This type of converter normally requires twelve switches for a rectifier and inverter composed of self turn-off switch such as a bi-polar transistor or IGBT with an anti-parallel diode. In this paper, a new three-phase to three-phase converter for ac motor drives is proposed. The proposed converter employs only eight switches and has the capability of delivering sinusoidal input currents with unity power factor and bidirectional power flow. This paper describes the feasibility and the operational limitations of the proposed structure. A mathematical model of the system is derived using generalized modulation theory and experimental results for steady state and dynamic behavior are presented to verify the developed model.

  • PDF

반송파와 신호파의 기본 데이터를 이용한 3상 전압형 인버터의 THD 저감 제어 (Control of Three Phase VSI using Fundamental Data of the Carrier and Signal for Reducing the THO)

  • 김영민;황종선;김종만;박현철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 기술교육위원회 창립총회 및 학술대회 의료기기전시회
    • /
    • pp.34-37
    • /
    • 2001
  • This research suggested the new algorithm controlled by micro processor which is already stored by various PWM form of output voltage by using fundamental data of the carrier and signal. The determined PWM pattern is not concerned with the signal wave form and the new algorithm can obtain the desired pulse width by synchronous of carrier. The PWM wave can be controlled with real time by using extra hardware and digital software and to speed up program processing, the control signals to switch the power semi-conductor of three phase PWM inverter, simultaneously use the output signal by microprocessor and extra hardware, and control signal by software. In the end, this method was proved by applying to Three phase voltage source inverter.

  • PDF

벡터 제어 유도 전동기의 데드 타임 효과 해석 및 보상 (The Analysis and Compensation of Dead Time Effects in a Vector-Controlled Induction Machine)

  • 김성환;류영재;장영학
    • 전기전자학회논문지
    • /
    • 제4권2호
    • /
    • pp.225-232
    • /
    • 2000
  • 전압원 인버터의 PWM 신호에 삽입되는 데드 타임은 인버터 출력 파형을 왜곡시키고, 토크 리플을 발생시켜 유도 전동기의 제어 성능을 떨어뜨린다. 본 논문에서 벡터 제어 유도 전동기의 데드 타임 보상 방법이 제안된다. 제안된 방법은 2상 정지 좌표계에서 인버터 출력 기준전압에 보상 전압을 더하는 전향 보상에 근거한다. 제안된 방법은 부가적인 하드웨어 없이 소프트웨어적으로 실현 가능하다. 실험 결과를 통하여 제안된 방법의 타당성과 유용성을 확인한다.

  • PDF

Performance Evaluation of Various Bus Clamped Space Vector Pulse Width Modulation Techniques

  • Nair, Meenu D.;Biswas, Jayanta;Vivek, G.;Barai, Mukti
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1244-1255
    • /
    • 2017
  • The space vector pulse width modulation (SVPWM) technique is a popular PWM method for medium voltage drive applications. Conventional SVPWM (CSVPWM) and bus clamped SVPWM (BCSVPWM) are the most common SVPWM techniques. This paper evaluates the performance of various advanced BCSVPWM strategies in terms of their harmonic distortion and switching loss based on a uniform frame work. A uniform frame work, pulse number captures the performance parameter variations of different SVPWM strategies for various number of samples with heterogeneous pulse numbers. This work compares different advanced BCSVPWM techniques based on the modulation index and location of the clamping position (zero vector changing angle ) of a phase in a line cycle. The frame work provides a fixed fundamental frequency of 50Hz. The different BCSVPWM switching strategies are implemented and compared experimentally on a 415V, 2.2kW, 50Hz, 3-phase induction motor drive which is fed from an IGBT based 2 KVA voltage source inverter (VSI) with a DC bus voltage of 400 V. A low cost PIC microcontroller (PIC18F452) is used as the controller platform.