• Title/Summary/Keyword: VS method

Search Result 1,653, Processing Time 0.035 seconds

Quantitative Sensory Test: Normal Range in Korean Adults and Application to Diabetic Polyneuropathy (정량적 감각 검사: 한국인에서의 연령별 정상 범위 및 당뇨병성 다발신경병증에서의 유용성 평가)

  • Kim, Su-Hyun;Kim, Sung-Min;Ahn, Suk-Won;Hong, Yoon-Ho;Park, Kyung-Seok;Sung, Jung-Joon;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.12 no.1
    • /
    • pp.21-26
    • /
    • 2010
  • Background: Although quantitative sensory test (QST) is being used with increasing frequency for measuring sensory thresholds in clinical practice and epidemiologic studies, there has been no age-matched normative data in Korean adults. The objective of this study is to evaluate the value of QST in diabetic polyneuropathy with normal range in Korean adults. Methods: The Computer Aided Sensory Examination IV 4,2 (WR Medical Electronics Co., Stillwater, Minnesota, U.S.A.), with 4,2,1 stepping algorithm was used to determine vibration and cold perception threshold in 70 normal controls and 19 patients with diabetic polyneuropathy aged from 21 to 79 years. The data were used to define age-matched upper and lower normal limits and normal range of side to side difference. We also evaluated the duration of diabetes, serum HbA1C level, and findings of nerve conduction study (NCS) and QST in patients with diabetic polyneuropathy. Results: In normal adults, sensory thresholds slightly increased with age, and a slight side-to-side difference was observed. The diagnostic sensitivity of QST was not higher than NCS in patients with diabetic polyneuropathy (36.8% vs. 42.1%, p=0.716), especially among elderly patients. Conclusions: QST might be used as a complementary test for NCS in the diagnosis of diabetic polyneuropathy. Although the QST is a simple method for the evaluation of peripheral nerve function, there are some limitations. Most of all, because the QST measuring is dependent on the subjective response of patients, the degree of concentration and cooperation of the patients can significantly affect the result. And thus, attention should be paid during the interpretation of QST results in patients with peripheral neuropathy.

Preliminary three-dimensional analysis of tooth movement and arch dimension change of the maxillary dentition in Class II division 1 malocclusion treated with first premolar extraction: conventional anchorage vs. mini-implant anchorage

  • Park, Heon-Mook;Kim, Byoung-Ho;Yang, Il-Hyung;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.42 no.6
    • /
    • pp.280-290
    • /
    • 2012
  • Objective: This study aimed to compare the effects of conventional and orthodontic mini-implant (OMI) anchorage on tooth movement and arch-dimension changes in the maxillary dentition in Class II division 1 (CII div.1) patients. Methods: CII div.1 patients treated with extraction of the maxillary first and mandibular second premolars and sliding mechanics were allotted to conventional anchorage group (CA, n = 12) or OMI anchorage group (OA, n = 12). Pre- and post-treatment three-dimensional virtual maxillary models were superimposed using the best-fit method. Linear, angular, and arch-dimension variables were measured with software program. Mann-Whitney U-test and Wilcoxon signed-rank test were performed for statistical analysis. Results: Compared to the CA group, the OMI group showed more backward movement of the maxillary central and lateral incisors and canine (MXCI, MXLI, MXC, respectively; 1.6 mm, p < 0.001; 0.9 mm, p < 0.05; 1.2 mm, p < 0.001); more intrusion of the MXCI and MXC (1.3 mm, 0.5 mm, all p < 0.01); less forward movement of the maxillary second premolar, first, and second molars (MXP2, MXM1, MXM2, respectively; all 1.0 mm, all p < 0.05); less contraction of the MXP2 and MXM1 (0.7 mm, p < 0.05; 0.9 mm, p < 0.001); less mesial-in rotation of the MXM1 and MXM2 ($2.6^{\circ}$, $2.5^{\circ}$, all p < 0.05); and less decrease of the inter-MXP2, MXM1, and MXM2 widths (1.8 mm, 1.5 mm, 2.0 mm, all p < 0.05). Conclusions: In treatment of CII div.1 malocclusion, OA provided better anchorage and less arch-dimension change in the maxillary posterior teeth than CA during en-masse retraction of the maxillary anterior teeth.

Pressure Effects on the Aquation of $cis-[Co(en)(NH_3)_2Cl_2]Cl$ in Acetone-Water Mixtures (아세톤-물 혼합용매에서 $cis-[Co(en)(NH_3)_2Cl_2]Cl$의 수화반응에 미치는 압력의 영향)

  • Jong-Jae Chung;Byung-Hwan Lee
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.5
    • /
    • pp.472-477
    • /
    • 1985
  • The rates for the aquation of $cis-[Co(en)(NH_3)_2Cl_2]Cl in acetone-water mixtures have been measured at various pressures and temperatures by the electric conductivity method. The rate constant measured at 25$^{\circ}$C in pure water solvent is 3.47 ${\times}10^{-4}$/sec. Rate constants are increased with increasing temperature, and decreased with increasing pressure and mole fraction of acetone. Activation volumes and other activation parameters are calculated from these rate constants. The activation volumes are all positive and lie in the limited range +2.82~+$8.2cm^3$/mole. The rate constants in aqueous acetone solution are analyzed with the solvent compositions. Plots of log $k_{obs}$ vs. Grunwald-Winstein Y values show that log $k_{obs}$ varies linearly and the gradients are about 0.25. The applications of a free energy cycle relating the process initial state ${\to}$ transition state in water to that in acetone-water mixture show that the changes in solvation of the transition state have a dominant effect on the rate. From these results the aquation of this complex would be discussed in terms of dissociative mechanism ($I_d$).

  • PDF

Electrochemical Characteristic Change of Cr-doped Li4Ti5O12 due to Different Water Solubility of Dopant Precursors (도판트 프리커서의 용해도 차이에 의한 Cr-doped Li4Ti5O12의 전기화학적 특성 변화)

  • Yun, Su-Won;Song, Hannah;Kim, Yong-Tae
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.1
    • /
    • pp.17-23
    • /
    • 2015
  • $Li_4Ti_5O_{12}$ (LTO) have attracted much attention of researchers in the field of energy storage, because of their excellent stability for electric vehicle application. A main drawback of LTO is however their insulating nature due to the wide bandgap, which should be addressed to enhance the battery performance. In this study, we investigated the effect of water solubility of dopant precursor on the electrochemical characteristics of conducting LTO prepared by doping with $Cr^{3+}$ ions with the well-known wet-mixing method. The solubility of dopant precursor directly affected the morphology and the phase of doped LTO, and therefore their battery performance. In the case of employing the most soluble dopant precursor, $Cr(NO_3)_2$, the doped LTO demonstrated a markedly enhanced discharge capacity at high C-rate (130mAh/g @ 10C), which is about 2 times higher value than that of bare LTO.

Characterization of the a-Se Film for Phosphor based X-ray light Modulator (형광체 기반 X선 광 변조기를 위한 비정질 셀레늄 필름 특성)

  • Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Ho;Cha, Byung-Youl;Shin, Jung-Wook;Lee, Kun-Hwan;Mun, Chi-Woong;Nam, Sang-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.306-309
    • /
    • 2007
  • PXLM(Phosphor based x-ray light modulator) has a combined structure by phosphor, photoconductor, and liquid crystal and it can realize x-ray image of high resolution in clinical diagnosis area. In this study, we fabricated a photoconductor and investigated electrical and optical properties to confirm application possibility of radiator detector of PXLM structure. As photoconductor, amorphous selenium(a-Se), which is used most in DR(Digital radiography) of direct conversion method, was used and for formation of thin film, it was formed as $20{\mu}m-thick$ by using thermal vacuum evaporation system. For a produced a-Se film, through XRD(X-ray diffraction) and SEM(Scanning electron microscope), we investigated that amorphous structure was uniformly established and through optical measurement, for visible light of 40 $0\sim630nm$, it had absorption efficiency of 95 % and more. After fabricated a-Se film on the top of ITP substrate, hybrid structure was manufactured through forming $Gd_2O_3:Eu$ phosphor of $270{\mu}m-thick$ on the bottom of the substrate. As the result to confirm electrical property of the manufactured hybrid structure, in the case of appling $10V/{\mu}m$, leakage current of $2.5nA/cm^2$ and x-ray sensitivity of $7.31nC/cm^2/mR$ were investigated. Finally, we manufactured PXLM structure combined with hybrid structure and liquid crystal cell of TN(Twisted nematic) mode and then, investigated T-V(Transmission vs. voltage) curve of external light source for induced x-ray energy. PXLM structure showed a similar optical response with T-V curve that common TN mode liquid crystal cell showed according to electric field increase and in appling $50\sim100V$, it showed linear transmission efficiency of $12\sim18%$. This result suggested an application possibility of PXLM structure as radiation detector.

Pylorus-preserving Proximal Gastrectomy vs. Total Gastrectomy with Jejunal Interposition for Proximal Gastric Adenocarcinomas (상부 위암에서 유문보존 근위부 위아전절제술과 공장간치술을 시행한 위전절제술의 비교)

  • Noh Seung-Moo;Jeong Hyun-Yong;Lee Byong-Seok;Cho June-Sik;Shin Kyung-Sook;Song Kyu-Sang;Lee Tae-yong
    • Journal of Gastric Cancer
    • /
    • v.2 no.3
    • /
    • pp.145-150
    • /
    • 2002
  • Purpose: The aim of this study was to evaluate the shortterm outcome of a pylorus-preserving proximal gastrectomy by comparing it with a jejunal interposition after a total gastrectomy in proximal gastric adenocarcinoma. Materials and Methods: For 22 patients (12 men and 10 women) who underwent a pylorus-preserving proximal gastrectomy, several clinical parameters were obtained from the medical records retrospectively. In this study, the data were collected between September 1993 and December 1999 at Chungnam National University Hospital, and the results were compared with those of 25 patients (17 men and 8 women) who underwent an isoperistaltic simple jejunal interposition. Results: The average operative time in the pylorus-preserving proximal gastrectomy group (220 minutes) was shorter than that in the jejunal interposition group (243 minutes) (P<0.05). The hemoglobin and hematocrit levels were significantly higher in the pylorus-preserving proximal gastrectomy group at 2 years after the operation. The body weight ratio (postoperative body weight/preoparative body weight) in patients who had a pylorus-preserving proximal gastrectomy was significantly higher than that in patients with a jejunal interposition at 2 years after the operation. The jejunal interposition procedure had better outcomes in anastomotic site stricture, duration of hospital stay, and number of removed lymph nodes (P<0.05). Conclusions: We think that from the viewpoint of quality of life, a pylorus-preserving proximal gastrectomy, as well as a jejunal interposition, is a useful reconstruction method for early adenocarcinomas of the proximal stomach. However, stricture of the esophagogastrostomy site in the pyloruspreserving proximal gastrectomy is a common problem to be solved in the future.

  • PDF

Electrical Resistivity-Measurements for the Detection of Fracture Zones in the Woraksan Granitic-Bodies (월악산화강암체의 파쇄대규명을 위한 전기비저항탐사)

  • 김지수;권일룡
    • The Journal of Engineering Geology
    • /
    • v.7 no.2
    • /
    • pp.113-126
    • /
    • 1997
  • Electrical resistivity methods of dipole - dipole array profiling and Schiumberger array sounding were tested on a segment of the Woraksan granitic batholith for the research into the imaging of irregular attitudes of fracture zones in the crystaaline rock in terms of processing and interpretation schemes. By the dipole - dipole array method, inhomogeneities such as small scale of fracture zones were properly delineated down at some depth even within hard rock environment. Fracture zones were interpreted to be at the boundaries between the high amplitude zone and very low amplitude zone in the resistivity plot and they were also successfully outlined in two - dimensional layer and pseudo - three - dimensional volume constructed by the incorporation of vertical sounding data. The surface location of the fracture zones was correlated by the zero - crossing point in the VLF(very low frequency) electromagnetic data. Pseudo - three - dimensional attitudes of fracture zones were efficiently illuminated by optimum projection angle. The mean of bulk resistivity for the Woraksan granite and the near fracture zones is estimated to be approximately of 4,000 ohm - m which is much higher than the value of 700 ohm - m for the Rwachunri limesilicate environment. This difference is due to both the rock type, i.e., biotite granite vs limesilicate, and the occurrence of secondary openings of fold and fault associated with the intrusion of granite. In this study statistical analyses on the resistivity color plot were performed in terms of three representative statistical moments, i.e., standard deviation, skewness, and kurtosis. The fracture zones in the standard deviation plot were characterized by the higher value, compared to the value of homogeneous portion. The upper boundary of the high resistivity zone was also successfully delineated in the skewness and kurtosis plots.

  • PDF

Authentication of Sesame Oil with Addition of Perilla Oil Using Electronic Nose Based on Mass Spectrometry (전자코-Mass spectrometry를 이용한 들기름이 혼합된 참기름의 판별 분석)

  • Son, Hee-Jin;Kang, Jin-Hee;Hong, Eun-Jeung;Lim, Chae-Lan;Choi, Jin-Young;Noh, Bong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.6
    • /
    • pp.609-614
    • /
    • 2009
  • Sesame oil was sometimes replaced by mixed oil due to high price in Korean market. To find out authentic sesame oil, electronic nose (E-nose) based on mass spectrometer system was used. Sesame oil was blended with perilla oil at the ratio of 97:3, 94:6, 91:9, 88:12 and 85:15, respectively. Intensities of each fragment from sesame oil by E-nose based on MS were completely different from those of perilla oil. The obtained data was used for discriminant function analysis. For quantitative analysis, the partial least square algorithm was used. The added concentration of perilla oil to sesame oil was correlated with discriminant function first score (DF1) and second score (DF2). From this relationship it could be found out how much perilla oil added. DFA plot indicated a significant separation of pure sesame oil and pure perilla oil. The different geographical origin of sesame oil was used for blending with perilla oil were closed to that of sesame oil. Korean sesame oil mixture and Indian sesame oil one were well separated. And the correlation between mixing ratios and DF1 values was found at the ratio of 97:3, 91:9, and 85:15 (SE vs PE oil), respectively. But the added concentration of perilla oil to sesame oil was correlated with discriminant function first score (DF1). E-nose based on MS system could be used as an efficient method for purity of oil quality.

Predictors of smoking Cessation in Outpatients (외래환자에서 금연 성공의 결정요인)

  • Kang, Yune-Sik;Jang, Joung-Soon;Hwang, Young-Sil;Hong, Dae-Yong;Kim, Jang-Rak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.3
    • /
    • pp.248-254
    • /
    • 2003
  • Objective : This study was conducted in order to investigate predictors of smoking cessation in outpatients. Method : Subjects were 40f adult smoking patients who saw their doctors in the outpatient setting at a university hospital, regardless of their willingness of otherwise in smoking cessation. Physicians delivered a brief, stop smoking prompt to all patients who smoked one or more cigarettes a day. Then they referred to on-site counselors who provided a brief, nurse assisted intervention with a survey to a randomly assigned intervention group (200 smoking patients), whom the counselors telephoned later to prevent relapse or promote the motivation to quit, or gave only a survey to a control group (201 smoking patients). After at least 5 months, self-reported current smoking cessation was confirmed later using cut-off values of 7 ppm or less in expired alveolar air after breath holding portable CO analyzer. Results : After 5 months, subjects in the intervention group were 1.56 times (95% C.I. 0.89-2.73) more likely to quit smoking than those in the non-intervention group (14.0% vs. 9.0%). Willingness to quit smoking in a month, scheduled admission in a month, self efficacy score and FTND (Fagerstrom Test for Nicotine Dependence) score were all significantly related with smoking cessation. In stepwise multiple logistic regression, previous attempts to quit smoking were significant instead of self efficacy score. In the intervention group who had willingness to quit smoking in a month (132 smoking patients), FTND score, whether quit date was today, and whether quit promise paper was submitting were all significantly related with smoking cessation. In stepwise multiple logistic regression, scheduled admission in a month and whether quit date was today were significant predictor variables, Smoking cessation treatment should be tailored to individual smoking patients considering these predictors.

The Clinical Efficiency of Clomiphene Citrate vs Clomiphene Citrate/GnRH Antagonist on Infertile Women with Normal Ovulatory Cycles (정상 배란주기의 불임 여성에서 Clomiphene Citrate 단독 사용과 GnRH Antagonist 병합 요법의 임상적 효용성에 관한 연구)

  • Lee, Woo Seok;Sang, Jae Hong;Kim, Jae Joon;Kim, Gwang June;Kim, Dong Ho;Lee, Sang Hun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.33 no.3
    • /
    • pp.149-157
    • /
    • 2006
  • Objective: This study was to investigate the clinical efficiency of clomiphene citrate/GnRH antagonist protocol comparing with the clomiphene citrate only protocol in infertile women with normal ovulatory cycles. Method: Among 116 patients, 43 were received assisted reproductive technologies using natural ovulatory cycle, 38 and 35 were received clomiphene citrate only protocol and clomiphene citrate/GnRH antagonist combined protocol, respectively, and the clinical results were compared and analyzed Results: In each group, basal levels of LH, FSH, $E_2$ and FSH, $E_2$ on hCG day injected were not different, but LH level and endometrial thickness on hCG injected day were decreased significantly and the pregnancy rate was increased significantly in clomiphene citrate/GnRH antagonist group. Conclusion: The pregnancy rate was increased significantly in clomiphene citrate/GnRH antagonist group compared with natural ovulatory cycle and clomiphene citrate only group.