• Title/Summary/Keyword: VP9

Search Result 214, Processing Time 0.027 seconds

Micromirrors Driven by Detached Piezoelectric Microactuators For Low-voltage and Wide-angle Rotation (저전압 대회전을 위한 분리된 압전 구동기에 의한 미소거울)

  • Kim, Sung-Jin;Jin, Young-Hyun;Lee, Won-Chul;Nam, Hyo-Jin;Bu, Jong-Uk;Cho, Young-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.3
    • /
    • pp.149-155
    • /
    • 2006
  • This paper presents a torsional micromirror detached from PZT actuators (TMD), whose rotational motion is achieved by push bars in the PZT actuators detached from the micromirror. The push bar mechanism is intended to reduce the bending, tensile and torsional constraints generated by the conventional bending bar mechanism, where the torsional micromirror is attached to the PZT actuators (TMA). We have designed, fabricated and tested prototypes of TMDs for single-axis and dual-axis rotation, respectively. The single-axis TMD generates the static rotational angle of $6.1^{\circ}$ at 16 VDC, which is 6 times larger than that of single-axis TMA, $0.9^{\circ}$. However, the rotational response curve of TMD shows hysteresis due to the static friction between the cover and the push bar in the PZT actuator. We have shown that 63.2% of the hysteresis is due to the static friction caused by the initial contact force of the PZT actuaor. Without the initial contact force, the rotational response curve of TMD shows linear voltage-angle characteristics. The dual-axis TMD generates the static rotational angles of $5.5^{\circ}$ and $4.7^{\circ}$ in x-axis and y-axis, respectively at 16 VDC. The measured resonant frequencies of dual-axis TMD are $2.1\pm0.1$ kHz in x-axis and $1.7\pm0.1$ kHz in y-axis. The dual-axis TMD shows stable operation without severe wear for 21.6 million cycles driven by 16 Vp-p sinusoidal wave signal at room temperature.

Regional variation in vertebral bone density and structure due to osteoporosis (골다공증에 따른 부위별 골 밀도와 구조의 변화)

  • Park, J.H.;Lee, S.J.;Chang, H.;Choi, W.S.;Kang, C.;Tack, G.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.169-170
    • /
    • 1998
  • In this study, regional variation in vertebral bone density due to osteoporosis were investigated using a method that employs images from QCT. QCT images(1mm thick slices) of the first lumbar vertebra from a normal person (23/M, BMD=139.8mg/ml) and from an osteoporotic patient (54/F, BMD=82.0mg/ml) were obtained. Uniform settings (140kVp, 204mA) were used and images of 300 Hounsfield Unit or greater were selectied to filler out soft tissue interference. To assess the regional variation of the area fraction the vertebral body was divided into 3 layers and each layer contained 9 regions. Area faction was calculated based on image analysis data. Our results showed that the area fraction at the middle of the vertebra was quite lower than the endplate and peripheral regions, but the area fraction values from the osteoporotic patient were uniform throughout the entire height of the vertebral body, which indicates the significant drop of BMD had occurred near both end-plates due to the osteoporosis, especially at the peripheral regions. Our results suggest the susceptability of the vertebrae to compression fracture types in osteoporotic spine.

  • PDF

Diagnostic reference levels in intraoral dental radiography in Korea

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Jung, Yun-Hoa;Yoon, Suk-Ja;Lee, Jae-Seo
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.237-242
    • /
    • 2012
  • Purpose: The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. Materials and Methods: One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. Results: The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 $mGycm^2$ (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 $mGycm^2$ (DAP). Doses at university dental hospitals were lower than those at dental clinics (p<0.05). Doses of digital radiography (DR) type were lower than those of film-based type (p<0.05). Conclusion: We recommend 3.1 mGy (PED), 87.4 $mGycm^2$ (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

A Study on the RSVP_Proxy for Micro Mobility (마이크로 이동성 위한 RSVP_Proxy에 관한 연구)

  • 박승균;오영환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.9B
    • /
    • pp.774-782
    • /
    • 2003
  • Generally, in the Mobile IP technologies, the use of RSVP(Resource ReSerVation Protocol) is recommended in order to provide a mobile node real-time service. However, the handoff of a mobile node increases the registration delay, RSVP reservation delay and signalling overhead in the Mobile IP and RSVP interworking. Specially, the resource reservation on the path between a mobile node and a correspondent node is the duplicated reservation and then causes unnecessary creation of the signalling overhead and waste of the resource, since the majority of the path before handoff and after handoff is same. If the radius of a cell providing a wireless interface to a mobile node is small, the number of handoff will increase and also signalling overhead and duplicated resource reservation will increase. In this paper, we proposed the integration model of Cellular IP and RSVP with RSVP proxy scheme. Here, Cellular IP protocol minimizes registration delay, transfer delay, and loss by handoff in micro cell network, the RS VP proxy that minimizes the duplication of resource reservation prevents the path for RSVP session from change using the address for reservation of a mobile node. Proposed scheme was evaluated in comparison with the existing Mobile IP and RSVP interworking scheme using the probability of resource reservation fail to the radius of a cell and the handoff rate.

Studies on the Viability of Frozen-thawed In Vitro Produced Blastocysts and Pregnancy Rate by Direct Transfer in Hanwoo Cattle (한우 체외 동결 수정란의 융해후 생존성과 직접이식후 수태률에 관한 연구)

  • 양보석;오성존;박원종
    • Journal of Embryo Transfer
    • /
    • v.12 no.1
    • /
    • pp.67-74
    • /
    • 1997
  • This study was carried out to increase the viability of bovine frozen4hawed in vitro produced (IVP) embryos and pregnancy rate by direct transfer method. Cumulus-oocyte complexes were aspirated from excised Hanwoo ovaries and matured in TGM 199 for 20~22 hours at 38.5$^{\circ}C$ in 2% $CO_2$ in air. Matured oocytes were fertilized with capacitated sperm for 6 hours and then co-cultured with cumulus cells for 9 days. 63% of the oocytes cultured was deaved and 29% out of them developed into blastocysts. Good or excellent grade of blastocysts on D 7 or 8 were frozen with 1.8M ethylene glycol as a cryoprotectant for direct transfer. Frozen embryos were thawed at 2$0^{\circ}C$ water for 10 sec following 4~5 second in air. For the survival assay of frozen4hawed lVP blastocysts, they were cultured in TCM 199 supplemented with 100$\mu$M $\beta$-mercaptoethanol and 20% FCS for 72 hours. The percentage of embryos developed to re-expanded or hatched after 72 hours culture was 95. 5 and 77.3%, respectively. When frozen-thawed Ivp embryos were transferred to 43 synchronized recipients by direct transfer method, eighteen recipients (41.8%) was pregnant. The highest pregnant was in naturafly synchronized recipients (71.4%), but induced estrus by using PRID(29.2%) and PGF$_2$$\alpha$(20.0%) was showed lower pregnancy rate. The pregnancy rate was higher in day 7 blastocysts(56.0%) than day 8 blastocysts(22.2%). (Key words: in vitro produced, blastocyst, frozen-thawed, direct transfer)

  • PDF

Development of a Small Animal CT using a Linear Detector Array and Small-Scale Slip Rings

  • An Ung Hwan;Chun In Kon;Lee Sang Chul;Cho Min Hyoung;Lee Soo Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.1
    • /
    • pp.43-47
    • /
    • 2005
  • We have developed a small bore x-ray CT for small animal imaging with a linear x-ray detector array and small-scale slip rings. The linear x-ray detector array consists of 1024 elements of 400□m×400□m with a gadolinium oxysulfide (GOS) scintillator on top of them. To avoid use of expensive large diameter slip rings for projection data transmission from the X­ray detector to the image reconstruction system, we used the wireless LAN technology. The projection data are temporally stored in the data acquisition system residing on the rotating gantry during the scan and they are transmitted to the image reconstruction system after the scan. With the wireless LAN technology, we only needed to use small-scale slip rings to deliver the AC electric power to the X-ray generator and the power supply on the rotating gantry. The performances of the small animal CT system, such as SNR, contrast, and spatial resolution, have been evaluated through experiments using various phantoms. It has been experimentally found that the SNR is almost linearly proportional to the tube current and tube voltage, and the minimum resolvable contrast is less than 30 CT numbers at 40kVp/3.0㎃. The spatial resolution of the small animal CT system has been found to be about 0.9Ip/㎜. Postmortem images of a piglet is also presented.

Energy Spectrum Analysis between Single and Dual Energy Source X-ray Imaging for PCB Non-destructive Test (PCB 비파괴 검사에 있어서 단일 에너지 소스와 이중 에너지 소스의 영상비교를 위한 엑스선 스펙트럼 분석)

  • Kim, Myungsoo;Kim, Giyoon;Lee, Minju;Kang, Dong-uk;Lee, Daehee;Park, Kyeongjin;Kim, Yewon;Kim, Chankyu;Kim, Hyoungtaek;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.153-159
    • /
    • 2015
  • Reliability of printed circuit board (PCB), which is based on high integrated circuit technology, is having been important because of development of electric and self-driving car. In order to answer these demand, automated X-ray inspection (AXI) is best solution for PCB non-destructive test. PCB is consist of plastic, copper, and, lead, which have low to high Z-number materials. By using dual energy X-ray imaging, these materials can be inspected accurately and efficiently. Dual energy X-ray imaging, that have the advantage of separating materials, however, need some solution such as energy separation method and enhancing efficiency because PCB has materials that has wide range of Z-number. In this work, we found out several things by analysis of X-ray energy spectrum. Separating between lead and combination of plastic and copper is only possible with energy range not dose. On the other hand, separating between plastic and copper is only with dose not energy range. Moreover the copper filter of high energy part of dual X-ray imaging and 50 kVp of low energy part of dual X-ray imaging is best for efficiency.

Prevalence of GII.4 Sydney 2012 and Recombinant GII.3P[12] Noroviruses Associated with Acute Gastroenteritis in Hospitalized Children in Thailand, 2015-2017

  • Manowong, Areerat;Chanta, Chulapong;Chan-it, Wisoot
    • Microbiology and Biotechnology Letters
    • /
    • v.50 no.1
    • /
    • pp.126-134
    • /
    • 2022
  • Norovirus (NoV) is an important pathogen causing acute gastroenteritis worldwide. The purpose of the present study was the molecular characterization of NoV. A total of 408 stool specimens collected from hospitalized children associated with acute gastroenteritis in Chiang Rai, Thailand, 2015-2017 were investigated for the presence of NoVs by RT-PCR. NoV GII was detected in 32 samples (7.8%). Five distinct genotypes were identified, including GII.4 (13/32, 40.6%), GII.3 (11/32, 34.3%), GII.17 (4/32, 12.5%), GII.2 (2/32, 6.3%), and GII.14 (2/32, 6.3%). NoV infection occurred mostly in young children under 3 years of age (31/32, 96.9%) and showed the main peak in summer months from March to April (18/32, 56.3%). Phylogenetic analysis revealed that all 13 GII.4 strains clustered with GII.4 Sydney 2012 variant. Representative GII.3 strains were analyzed as a recombinant GII.3P[12] strain. Several amino acid differences were found in the antigenic epitopes and antibody binding sites of the VP1 capsid of the GII.3P[12]. Homology modeling of the P domain of the GII.3P[12] strain demonstrated that 10/13 amino acid differences were predicted to be located on the surface-exposed area of the capsid structure. These amino acid changes might affect the infectivity and the antigenicity of the recombinant GII.3P[12]. The prevalence of GII.4 Sydney 2012 and recombinant GII.3P[12] strains indicates the genetic diversity of circulating NoVs in Thailand, emphazing the importance of continuous surveillance to mornitor newly emerging NoV strains in the future.

Prevalence of Senecavirus A in pigs from 2014 to 2020: a global systematic review and meta-analysis

  • Xuhua Ran;Zhenru Hu;Jun Wang ;Zhiyuan Yang ;Zhongle Li ;Xiaobo Wen
    • Journal of Veterinary Science
    • /
    • v.24 no.3
    • /
    • pp.48.1-48.13
    • /
    • 2023
  • Background: Senecavirus A (SVA), a member of the family Picornaviridae, is newly discovered, which causes vesicular lesions, lameness in swine, and even death in neonatal piglets. SVA has rapidly spread worldwide in recent years, especially in Asia. Objectives: We conducted a global meta-analysis and systematic review to determine the status of SVA infection in pigs. Methods: Through PubMed, VIP Chinese Journals Database, China National Knowledge Infrastructure, and Wanfang Data search data from 2014 to July 26, 2020, a total of 34 articles were included in this analysis based on our inclusion criteria. We estimated the pooled prevalence of SVA in pigs by the random effects model. A risk of bias assessment of the studies and subgroup analysis to explain heterogeneity was undertaken. Results: We estimated the SVA prevalence to be 15.90% (1,564/9,839; 95% confidence interval [CI], 44.75-65.89) globally. The prevalence decreased to 11.06% (945/8,542; 95% CI, 28.25-50.64) after 2016. The highest SVA prevalence with the VP1-based RT-PCR and immunohistochemistry assay was 58.52% (594/1,015; 95% CI, 59.90-83.96) and 85.54% (71/83; 95% CI, 76.68-100.00), respectively. Besides, the SVA prevalence in piglet herds was the highest at 71.69% (119/166; 95% CI, 68.61-98.43) (p < 0.05). Moreover, our analysis confirmed that the subgroups, including country, sampling year, sampling position, detected gene, detection method, season, age, and climate, could be the heterogeneous factors associated with SVA prevalence. Conclusions: The results indicated that SVA widely exists in various countries currently. Therefore, more prevention and control policies should be proposed to enhance the management of pig farms and improve breeding conditions and the environment to reduce the spread of SVA.

Vertical root fracture diagnosis in teeth with metallic posts: Impact of metal artifact reduction and sharpening filters

  • Debora Costa Ruiz;Lucas P. Lopes Rosado;Rocharles Cavalcante Fontenele;Amanda Farias-Gomes;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.139-145
    • /
    • 2024
  • Purpose: This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth. CBCT scans were then acquired under the following parameters: 8 mA, a 5×5 cm field of view, a voxel size of 0.085 mm, 90 kVp, and with MAR either enabled or disabled. Five oral and maxillofacial radiologists independently evaluated the CBCT exams under each MAR mode and across 3 sharpening filter conditions: no filter, Sharpen 1×, and Sharpen 2×. The diagnostic performance was quantified by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. These metrics were compared using 2-way analysis of variance with a significance level of α=5%. Intra- and inter-examiner agreement were assessed using the weighted kappa test. Results: Neither MAR nor the application of sharpening filters significantly impacted AUC or specificity (P>0.05). However, sensitivity increased when MAR was combined with Sharpen 1× and Sharpen 2× (P=0.015). The intra-examiner agreement ranged from fair to substantial (0.34-0.66), while the inter-examiner agreement ranged from fair to moderate (0.27-0.41). Conclusion: MAR in conjunction with sharpening filters improved VRF detection; therefore, their combined use is recommended in cases of suspected VRF.