• Title/Summary/Keyword: VIM

Search Result 99, Processing Time 0.029 seconds

Normal Glenohumeral and Scapulothoracic Movement at the Coronal Plane (정상인의 관상면에서의 관절와상완운동 및 견갑흉곽운동)

  • Rhee Yong-Girl;Vim Chang-Moo
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.1
    • /
    • pp.93-99
    • /
    • 1998
  • We measured the glenohumeral and scapulothoracic movements during abduction of the arm in the coronal plane with radiologic analysis in the 30 shoulders of normal male adults who were without pain, limitation of motion, and history of trauma. In the resting position, the glenoid cavity of the scapula faced somewhat superiorly in over 80 percents of the individuals, the mean superior tilting was 5.7 degrees. The mean total scapulothoracic movement was 65.8 degrees and the mean total glenohumeral movement was 106.8 degrees during abduction of arm in the coronal plane. The mean ratio of the glenohumeral movement to the scapulothoracic movement was 1.6 and this GH/ST ratio was decreased toward the extreme abduction. When the arm was abducted, external rotation of the humeral head occurred and this external rotation was increased smoothly during 0 degree through 90 degrees, but steeply above 90 degrees. The acromiohumeral interval was 10.9 mm at the resting positon, and this interval decreased during the arm abduction. The superior migration of the humeral head was 3.1 mm while abducting the arm. Our measurement of the relationships of glenohumeral and scapulothoracic movements at the coronal plane would be useful in the understandings of the biomechanics of shoulder, but further study would be required for the analysis of the three dimensional relationship because of the limitation of our two dimensional analysis.

  • PDF

Aggregation of Human Eyelid Adipose-derived Stem Cells by Human Body Fluids

  • Song, Yeonhwa;Yun, Sujin;Yang, Hye Jin;Yoon, A Young;Kim, Haekwon
    • Development and Reproduction
    • /
    • v.16 no.4
    • /
    • pp.339-351
    • /
    • 2012
  • Fetal bovine serum (FBS) is the most frequently used serum for the cultivation of mammalian cells. However, since animal-derived materials might not be appropriate due to safety issues, allogeneic human serum (HS) has been used to replace FBS, particularly for the culture of human cells. While there has been a debate about the advantages of HS, its precise effect on human adult stem cells have not been clarified. The present study aimed to investigate the effect of HS on the human eyelid adipose stem cells (HEACs) in vitro. When HEACs were cultivated in a medium containing 10% HS, many cells moved into several spots and aggregated there. The phenomenon was observed as early as 9 days following 10% HS treatment, and 12 days following 5% HS plus 5% FBS treatment. However, the aggregation was never observed when the same cells were cultivated with 10% FBS or bovine serum albumin. To examine whether cell density might affect the aggregation, cells were seeded with different densities on 12-well dish. Until the beginning of aggregation, cells seeded at low densities exhibited the longest culture period of 16 days whereas cells seeded at high densities showed the shortest period of 9 days to form aggregation. The number of cells was $15.1{\pm}0.2{\times}10^4$ as the least for the low density group, and $29.3{\pm}2.8{\times}10^4$ as the greatest for the high density group. When human cord blood serum or normal bovine serum was examined for the same effect on HEACs, interestingly, cord blood serum induced the aggregation of cells whereas bovine serum treatment has never induced. When cells were cultivated with 10% HS for 9 days, they were obtained and analyzed by RT-PCR. Compared to FBS-cultivated HEACs, HS-cultivated HEACs did not express VIM, and less expressed GATA4, PALLD. On the other hand, HS-cultivated HEACs expressed MAP2 more than FBS-cultivated HEACs. In conclusion, human adult stem cells could move and form aggregates by the treatment with human body fluids.

Remote field Eddy Current Technique Development for Gap Measurement of Neighboring Tubes of Nuclear Fuel Channel in Pressurized Heavy Water Reactor (중수로 핵연료채널과 인접관의 간격측정을 위한 원거리장 와전류검사 기술개발)

  • Jung, H.K.;Lee, D.H.;Lee, Y.S.;Huh, H;Cheong, Y.M.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.164-170
    • /
    • 2004
  • Liquid Injection Nozzle(LIN) tube and Calandria tube(CT) in pressurized Heavy Water Reactor (PHWR) are .ross-aligned horizontally. These neighboring tubes can contact each other due to the sag of the calandria tube resulting from the irradiation creep and thermal creep, and fuel load, etc. In order to judge the contact which might be the safety concern, the remote field eddy current (RFEC) technology is applied for the gap measurement in this paper. LIN can be detected by inserting the RFEC probe into pressure tube (PT) at the crossing point directly. To obtain the optimal conditions of the RFEC inspection, the sensitivity, penetration and noise signals are considered simultaneously. The optimal frequency and coil spacing are 1kHz and 200mm respectively. Possible noises during LIN signal acquisition are caused by lift-off, PT thickness variation, and gap variation between PT and CT. The simulated noise signals were investigated by the Volume Integral Method(VIM). Signal analysis on the voltage plane describes the amplitude and shape of LIN and possible defects at several frequencies. All the RFEC measurements in the laboratory were done in variance with the CT/LIN gap and showed the relationship between the LIN gap and the signal parameters by analyzing the voltage plane signals.

Design Strategy Analysis of the Germean Firm Braun (독일 브라운 사의 디자인 전략 분석)

  • 이병종
    • Archives of design research
    • /
    • no.18
    • /
    • pp.165-174
    • /
    • 1996
  • In the I950s the German firm Braun began to pursue a policy of uncompromising modem design for products aimed at the upper reaches of the market. Dr. Fritz Eichler as a head of design with Hans Gugelot and Otl Aicher in the Graduate School VIm developed the guide line of Braun Design strategy as the foundation of the corporate identity programme. In 1955 Dieter Rams joined the staff, and was largely responsible for establishing the formal characteristics of Braun Design and its further development. In the mid-1950s complete product programme of the firm Braun began to be re-designed, and these undoubtedly hit the market. New design line of the firm Braun, was an exclusive avantgarde movement at that time, which became to be the epitome of the idea of an objectifiable "Good Form". By the result in the 60s and 70s, when Braun product program was completely re-designed to the new line, Braun Design had a decisive influence on the design scene of the world. Braun Design is essentially functional and concrete, which depends on perfect fulfillment of purpose, precision, safety, durability, the quality of the product and, more recently, environmental compatibility is similarly balanced and unified approach, eliminating every unnecessary detail and concentrating on ordering essential elements. elements.

  • PDF

Manufactures of dental casting Co-Cr-Mo based alloys in addition to Sn, Cu and analysis of infrared thermal image for melting process of its alloys (Sn 및 Cu를 첨가한 치과 주조용 Co-Cr-Mo계 합금제조 및 용해과정 분석)

  • Kang, Hoo-Won;Park, Young-Sik;Hwang, In;Lee, Chang-Ho;Heo, Yong;Won, Yong-Gwan
    • Journal of Technologic Dentistry
    • /
    • v.36 no.3
    • /
    • pp.141-147
    • /
    • 2014
  • Purpose: Dental casting #Gr I (Co-25Cr-5Mo-3Sn-1Mn-1Si), #Gr II (Co-25Cr-5Mo-5Cu-1Mn -1Si) and #Gr III (Co-25Cr-5Mo-3Sn-5Cu-1Mn-1Si) master alloys of granule type were manufactured the same as manufacturing processes for dental casting Ni-Cr and Co-Cr-Mo based alloys of ingot type. These alloys were analyzed melting processes with heating time of high frequency induction centrifugal casting machine using infrared thermal image analyzer. Methods: These alloys were manufactured such as; alloy design, the first master alloy manufatured using vacuum arc casting machine, melting metal setting in crucible, melting in VIM, pouring in the mold of bar type, cutting the gate and runner bar and polishing. These alloys were put about 30g/charge in the ceramic crucible of high frequency induction centrifugal casting machine and heat, Infrared thermal image analyzer indicated alloys in the crucible were set and operated. Results: The melting temperatures of these alloys measuring infrared thermal image analyzer were decreased in comparison with remanium$^{(R)}$ GM 800+, vera PDI$^{TM}$, Biosil$^{(R)}$ f, WISIL$^{(R)}$ M type V, Ticonium 2000 alloys of ingot type and vera PDS$^{TM}$(Aabadent, USA), Regalloy alloys of shot type. Conclusion: Co-Cr-Mo based alloy in addition to Sn(#Gr I alloy) were decreased the melting temperature with heating time of high frequency induction centrifugal casting machine using infrared thermal image analyzer.

Protection of Specific-pathogen-free (Spf) Foals from Severe Equine Herpesvirus Type-1 (Ehv-1) Infection Following Immunization with Non-infectious L-particles

  • Mohd Lila Mohd-Azmi;John Gibson;Frazer Rixon;Lauchlan, John-Mc;Field, Hugh-John
    • Journal of Microbiology
    • /
    • v.40 no.3
    • /
    • pp.183-192
    • /
    • 2002
  • Cells infected With equine herpesvirus type-1 (EHV-1) Produced both infectious and non-infectious Virus-related particles. Compared to the whole virion, non-infectious particles termed L-particles were deter-mined to lack 150 kDa protein, commonly known as nucleocapsid protein. The potential of L-particles to induce immune responses was studied in mice and foals. Intranasal immunization with L-particles or whole virions induced poor IgG antibody responses in mice. Interestingly, despite the poor antibody response, the conferred immunity protected the host from challenge infections. This was indicated by a significant reduction in virus titers in line with recovery towards normal body weight. Subsequently, the test on the usefulness of L-particles as immunizing agents was extended to foals. Immunization of specific-pathogen-free (SPF) foals resulted in similar results. As determined by a complement-fixing-antibody test (CFT), foals seroconverted when they were immunized either with inactivated L-particles or whole virions via intramuscular (i.m.) injections. The presence of the antibody correlated with the degree of protection. Beyond day 1 post challenge infection (p.i.), there was no virus shedding in the nasal mucus of foals immunized with whole EHV-1 virions. Virus shedding was observed in foals Immunized with L-particles but limited to days 6 to 8 p.i. only. In contrast, extended vim shedding was observed in non-immunized foals and it was well beyond day 14 p.i. Viremia was not detected for more than four days except in non-immunized foals. Immunization in mice via intranasal (i.n.) conferred good protection. However, compared to the i.n. route, a greater degree of protection was obtained in foals following immunization via i.m. route. Despite variation in the degree of protection due to different routes of immunization in the two animal species, our results have established significant evidence that immunization with L-particles confers protection in the natural host. It is suggested that non-infectious L-particles should be used as immunizing agents for vaccination of horses against EHV-1 infection.

Analysis and Usefulness of Microelectrode Recording during Deep Brain Stimulation Surgery in Movement Disorders (이상운동질환에 대한 뇌심부자극 수술 중에 미세전극 기록의 분석과 유용성)

  • Baek, Jae-Seung;Park, Sang-Ku;Kim, Dong-Jun;Park, Chan-Woo;Lim, Sung-Hyuk;Hyun, Soon-Chul
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.4
    • /
    • pp.468-474
    • /
    • 2019
  • Deep brain stimulation (DBS) is an effective surgical procedure for treating drug refractory movement disorders, and DBS involves delivering high frequency electrical stimulation to deep brain nuclei. Microelectrode recording (MER) is a complementary test that can precisely identify the location of deep brain nuclei, along with MRI correlation, during DBS surgery to improve the surgical outcome and minimize side effects. The purpose of this paper is to analyze the neuro-physiological waveforms and identify the usefulness of MER by analyzing the MER performed during DBS surgery for treating movement disorders. We retrospectively reviewed 28 patients who underwent MER during DBS surgery for movement disorders from January to December 2018. Of the 28 patients, 38 MERs for the subthalamic nucleus (STN), 10 MERs for the globuspallidusinternus (Gpi), and 4 MERs for the ventral intermediate thalamic nucleus (VIM) were performed. In all the cases, the target sites were found and micro-stimulations were used to check for side effects and to readjust the target sites. The clinical symptoms of all 28 patients improved after surgery. In conclusion, MER is a useful test that employs neuro-physiological waveforms to accurately identify the deep brain nuclei, along with MRI correlation, to improve the DBS surgical outcomes for movement disorders and to minimize side effects.

Investigation on Resistance to Hydrogen Embrittlement of High Nitrogen Austenitic Steels for Hydrogen Pipe by the Disc Pressure Test and the Tensile Test on Hydrogen Pre-charged Specimens (디스크 시험 및 수소처리 인장시험에 의한 수소배관용 고질소 스테인리스강의 내수소취성 평가 연구)

  • Dong-won, Shin;Min-kyung, Lee;Jeong Hwan, Kim;Ho-seong, Seo;Jae-hun, Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.16-23
    • /
    • 2022
  • In this study, characteristics of effect on hydrogen gas was investigated to hydrogen embrittlement by disk and tensile tests. The developed and commercial alloy was fabricated to a plate material made from an alloy ingot. The prepared materials were processed in the form of a disk to measure rupture pressure by hydrogen and helium gas at a rate of 0.1 to 1,000 bar/min. In the hydrogen pre-charged tensile test, a specimen was hydrogenated using an anode charging method, and the yield strength, ultimate tensile strength, elongation, and reduction in area rate were carried by a strain rate test. Also, the microstructure was observed to the fracture surface of the tensile test specimen. As a result, the developed materials satisfied endurable hydrogen embrittlement, and the fractured surface showed a brittleness fracture surface with a depth of several ㎛, but dimple due to ductile fracture could be observed.

Development of an anisotropic spatial interpolation method for velocity in meandering river channel (비등방성을 고려한 사행하천의 유속 공간보간기법 개발)

  • You, Hojun;Kim, Dongsu
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.7
    • /
    • pp.455-465
    • /
    • 2017
  • Understanding of the two-dimensional velocity field is crucial in terms of analyzing various hydrodynamic and fluvial processes in the riverine environments. Until recently, many numerical models have played major roles of providing such velocity field instead of in-situ flow measurements, because there were limitations in instruments and methodologies suitable for efficiently measuring in the broad range of river reaches. In the last decades, however, the advent of modernized instrumentations started to revolutionize the flow measurements. Among others, acoustic Doppler current profilers (ADCPs) became very promising especially for accurately assessing streamflow discharge, and they are also able to provide the detailed velocity field very efficiently. Thus it became possible to capture the velocity field only with field observations. Since most of ADCPs measurements have been mostly conducted in the cross-sectional lines despite their capabilities, it is still required to apply appropriate interpolation methods to obtain dense velocity field as likely as results from numerical simulations. However, anisotropic nature of the meandering river channel could have brought in the difficulties for applying simple spatial interpolation methods for handling dynamic flow velocity vector, since the flow direction continuously changes over the curvature of the channel shape. Without considering anisotropic characteristics in terms of the meandering, therefore, conventional interpolation methods such as IDW and Kriging possibly lead to erroneous results, when they dealt with velocity vectors in the meandering channel. Based on the consecutive ADCP cross-sectional measurements in the meandering river channel. For this purpose, the geographic coordinate with the measured ADCP velocity was converted from the conventional Cartesian coordinate (x, y) to a curvilinear coordinate (s, n). The results from application of A-VIM showed significant improvement in accuracy as much as 41.5% in RMSE.