• Title/Summary/Keyword: V2I

Search Result 5,336, Processing Time 0.038 seconds

Intravenous levetiracetam versus phenobarbital in children with status epilepticus or acute repetitive seizures

  • Lee, Yun-Jeong;Yum, Mi-Sun;Kim, Eun-Hee;Ko, Tae-Sung
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.1
    • /
    • pp.35-39
    • /
    • 2016
  • Purpose: This study compared the efficacy and tolerability of intravenous (i.v.) phenobarbital (PHB) and i.v. levetiracetam (LEV) in children with status epilepticus (SE) or acute repetitive seizure (ARS). Methods: The medical records of children (age range, 1 month to 15 years) treated with i.v. PHB or LEV for SE or ARS at our single tertiary center were retrospectively reviewed. Seizure termination was defined as seizure cessation within 30 minutes of infusion completion and no recurrence within 24 hours. Information on the demographic variables, electroencephalography and magnetic resonance imaging findings, previous antiepileptic medications, and adverse events after drug infusion was obtained. Results: The records of 88 patients with SE or ARS (median age, 18 months; 50 treated with PHB and 38 with LEV) were reviewed. The median initial dose of i.v. PHB was 20 mg/kg (range, 10-20 mg/kg) and that of i.v. LEV was 30 mg/kg (range, 20-30 mg/kg). Seizure termination occurred in 57.9% of patients treated with i.v. LEV (22 of 38) and 74.0% treated with i.v. PHB (37 of 50) (P=0.111). The factor associated with seizure termination was the type of event (SE vs. ARS) in each group. Adverse effects were reported in 13.2% of patients treated with i.v. LEV (5 of 38; n=4, aggressive behavior and n=1, vomiting), and 28.0% of patients treated with i.v. PHB (14 of 50). Conclusion: Intravenous LEV was efficacious and safe in children with ARS or SE. Further evaluation is needed to determine the most effective and best-tolerated loading dose of i.v. LEV.

A Study on the Effective Free Surface of Fluid Cargo (유동화물의 유효자유표면에 관한 연구)

  • Hur, I.;Wang, J.S.
    • Journal of the Korean Institute of Navigation
    • /
    • v.11 no.2
    • /
    • pp.73-88
    • /
    • 1987
  • It is well known that the height of tank metacenter above the centroid of fluid in a tank is given by i/v where I is the inertia moment of free surface and v is the fluid volume. It is supposed in this formula that the inclination of ship is small and that the free surface of fluid do not touch the top and the bottom of tank. It the inclination of ship is large, the height of tank metacenter may be possibly greater than that given by i/v. The height of tank metacenter is smaller than i/v when the free surface of fluid touch the top or the bottom of tank. The reasonable method to calculate the height of tank metacenter is presented in this paper and prepared in FORTRAN program by FUNCTION EFFRES. The approximate formula was also developed and given by $g_m=(1+\frac{2}{1}tan^2\theta)[1-EXP\{-12(\frac{\alpha(1-\alpha)k}{tan\theta})^{1.25}\}]\frac{i}{v}$ where $g_m$ is the distance from the centroid of fluid to the tank metacenter, $\theta$ is inclined angle of ship, $\alpha$ is the ratio of filled volume to tank capacity and k is the ratio of the depth to the width of tank. The values calculated by the approximate formula given in this paper were compared with the exact values from the computer program and proved out to be sufficiently precise for practical use.

  • PDF

Characterization of αX I-Domain Binding to Receptors for Advanced Glycation End Products (RAGE)

  • Buyannemekh, Dolgorsuren;Nham, Sang-Uk
    • Molecules and Cells
    • /
    • v.40 no.5
    • /
    • pp.355-362
    • /
    • 2017
  • The ${\beta}2$ integrins are cell surface transmembrane proteins regulating leukocyte functions, such as adhesion and migration. Two members of ${\beta}2$ integrin, ${\alpha}M{\beta}2$ and ${\alpha}X{\beta}2$, share the leukocyte distribution profile and integrin ${\alpha}X{\beta}2$ is involved in antigen presentation in dendritic cells and transendothelial migration of monocytes and macrophages to atherosclerotic lesions. ${\underline{R}}eceptor$ for ${\underline{a}}dvanced$ ${\underline{g}}lycation$ ${\underline{e}}nd$ ${\underline{p}}roducts$ (RAGE), a member of cell adhesion molecules, plays an important role in chronic inflammation and atherosclerosis. Although RAGE and ${\alpha}X{\beta}2$ play an important role in inflammatory response and the pathogenesis of atherosclerosis, the nature of their interaction and structure involved in the binding remain poorly defined. In this study, using I-domain as a ligand binding motif of ${\alpha}X{\beta}2$, we characterize the binding nature and the interacting moieties of ${\alpha}X$ I-domain and RAGE. Their binding requires divalent cations ($Mg^{2+}$ and $Mn^{2+}$) and shows an affinity on the sub-micro molar level: the dissociation constant of ${\alpha}X$ I-domains binding to RAGE being $0.49{\mu}M$. Furthermore, the ${\alpha}X$ I-domains recognize the V-domain, but not the C1 and C2-domains of RAGE. The acidic amino acid substitutions on the ligand binding site of ${\alpha}X$ I-domain significantly reduce the I-domain binding activity to soluble RAGE and the alanine substitutions of basic amino acids on the flat surface of the V-domain prevent the V-domain binding to ${\alpha}X$ I-domain. In conclusion, the main mechanism of ${\alpha}X$ I-domain binding to RAGE is a charge interaction, in which the acidic moieties of ${\alpha}X$ I-domains, including E244, and D249, recognize the basic residues on the RAGE V-domain encompassing K39, K43, K44, R104, and K107.

AN ANALYTICAL DC MODEL FOR HEMTS (헴트 소자의 해석적 직류 모델)

  • Kim, Yeong-Min
    • ETRI Journal
    • /
    • v.11 no.2
    • /
    • pp.109-119
    • /
    • 1989
  • Based on the 2-dimensional charge-control simulation[4], a purely analytical model for MODFET's is proposed. In this model, proper treatment of the diffusion effect in the 2-DEG transport due to the gradual channel opening along the 2-DEG channel was made to explain the enhanced mobility and increased thershold voltage. The channel thickness and gate capacitance are experssed as functions of gate vlotage including subthreshold characteristics of the MODFET's analytically. By introducing the finite channel opening and an effective channel-length modulation, the slope of the saturation region of the I-V curves was modeled. The smooth transition of the I-V curves from linear-to-saturation region of the I-V curves was possible using the continuous Troffimenkoff-type of field-dependent mobility. Furthermore, a correction factor f was introduced to account for the finite transtition section forming between the GCA and the saturated section. This factor removes the large discrepanicies in the saturation region fo the I-V curves presicted by existing 1-dimensional models. The fitting parameters chosen in our model were found to be predictable and vary over relatively small range of values.

  • PDF

A V-I Converter Design for Wide Range PLL (넓은 주파수 영역 동작의 PLL을 위한 V-I 변환기 설계)

  • Hong, Dong-Hee;Lee, Hyun-Seok;Park, Jong-Wook;Sung, Man-Young;Lim, Shin-Il
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.3 s.357
    • /
    • pp.52-58
    • /
    • 2007
  • This paper describes the PLL of TCON(Timing Controller) chip for FPD(Flat Panel Display). The recent TCON requires wide range frequency operation of $8\sim135MHz$ in PLL. In order to be satisfied this requirement the new V-I converter.circuit. The V-I converter of new architecture increased the minimum/maximum current ratio which widens the operation frequency range of VCO's md also guaranteed linearity of VCO's. The proposed PLL circuits in FPD TCON show the measuring performance of loops RMS jitter in the range of $8\sim135MHz$. The designed circuit was fabricated in 1-ploy 3-metal 0.25um TSMC process technology and has a operation range or $8\sim135MHz$ with 2.5V power.

A V-I Converter Design for Power Variation Insensitivity PLL (전원 전압 변화에 둔감한 PLL을 위한 V-I 변환기 설계)

  • Lee, Hyun-Seok;Hong, Dong-Hee;Park, Jong-Wook;Lim, Shin-Il;Sung, Man-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.3 s.357
    • /
    • pp.59-64
    • /
    • 2007
  • This paper describes the PLL of TCON(Timing Controller) chip for FPD(Flat Panel Display). We propose a new V-I converter which is insensitive to the power supply variation when it is applied to the TCON. The new V-I converter compensated the output frequency of VCO by appling the current that is inversely proportional to the voltage variation. The proposed idea is implemented with a 1-ploy 3-metal 0.25m TSMC CMOS technology and has the output frequency range from 192MHz to 360MHz at the supply voltage of 2.5V. Measurement result shows the RMS jitter of 100ps in the above output frequency range.

Pharmacokinetics of 11-Hydroxyaclacinomycin X (ID-6105), a Novel Anthracycline, after i.v. Bolus Multiple Administration in Rats

  • Yoo Bo-Im;Ahan Kwang Bok;Kang Min Hee;Kwon Oh-Seung;Hong Young-Soo;Lee Jung Joon;Lee Hong Sub;Ryu Jung Su;Kim Tae Yong;Moon Dong-Cheul;Song Sukgil;Chung Youn Bok
    • Archives of Pharmacal Research
    • /
    • v.28 no.4
    • /
    • pp.476-482
    • /
    • 2005
  • We investigated the pharmacokinetics of 11-hydroxyaclacinomycin X (ID-6105), a novel anthracycline, after intravenous (i.v.) bolus administration at a multiple dose every 24 h for 5 days in rats. To analyze ID-6105 levels in biological samples, we used an HPLC-based method which was validated in a pharmacokinetic study by suitable criteria. The concentrations of ID-6105 after the multiple administration for 5 days were not significantly different from the results after the single administration. The $t_{1/2\alpha}, t_{l/2\beta}, V_{dss}, and CL_{t}$ after the multiple administration were not significantly different from the values after the single administration. Moreover, the concentrations of ID-6105 1 min at day 1-5 after i.v. bolus multiple administration did not show the significant difference. Of the various tissues, ID-6105 mainly distributed to the kidney, lung, spleen, adrenal gland, and liver after i.v. bolus multiple administration. ID-6105 concentrations in the kidney or lung 2 h after i.v. bolus administration were comparable to the plasma concentration shortly after i.v. bolus administration. However, the ID-6105 concentrations in various tissues 48 h after i.v. bolus administration decreased to low levels. ID-6105 was excreted largely in the bile after i.v. bolus multiple administration at the dose of 3 mg/kg. The amounts of ID-6105 found in the bile by 12 h or in the urine by 48 h after the administration were calculated to be $14.1\% or 4.55\%$ of the initial dose, respectively, indicating that ID-6105 is mostly excreted in the bile. In conclusion, ID-6105 was rapidly cleared from the blood and transferred to tissues, suggesting that ID-6105 might not be accumulated in the blood following i.v. bolus multiple dosages of 3 mg/kg every 24 h for 5 days. By 48 h after i.v. bolus administration, ID-6105 concentrations in various tissues had decreased to very low levels. The majority of ID-6105 appears to be excreted in the bile.

A Study on Motive and Type of V.I.P. Assassination (주요요인 암살의 동기 및 대책에 관한 연구)

  • Lee, Jin-Moon
    • Korean Security Journal
    • /
    • no.2
    • /
    • pp.193-210
    • /
    • 1999
  • Through the case study, this thesis suggests several methods to prevent the assassination attempt on V.I.P. by examining what makes assassin assassinate V.I.P. and analyzing various kinds of motive and type. The paper, aiming to prevent assassination on V.I.P. consists of four chapters. Chapter I, the introductory chapter of this thesis, describes regarding the V.I.P. protection environment surrounding our nation. Chapter II concerns various kinds of motive and type of assassination. Under the title 'Point and Provision of Assassination' , chapter III shows several example case studies on assassinations occurred in our nation and foreign countries and suggests it's points and the lesson these case studies give us. The fourth chapter concludes with a bibliography. The conclusion of this study can be summarized in a word as following proverb; 'Providing is Preventing'.

  • PDF

Studies on electrocardiogram of the normal Korean native cattle I. Standard limb leads (정상적(正常的)인 한우(韓牛)의 심전도(心電圖)에 관(關)한 연구(硏究) I. 표준지유도(標準肢誘導))

  • Choi, In-hyuk;Jung, In-sung;Kim, Nam-soo;Suh, Doo-seok
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.4
    • /
    • pp.719-734
    • /
    • 1993
  • The electrocardiographic(ECG) parameters on the standard limb leads in the normal Korean native cattle have been measured with a 3 channel Electrocardiograph built in a computed analysis. The study was conducted on the animals 98 heads of mean age of 17.7 months. Conduction parameters, waves, intervals and segments have been recorded. The recordings were analyzed as to shape and amplitude of the P and T waves and the components of the QRS complex. Heart rate was recorded by the Electrocardiogram which were a mean of $80.4{\pm}11.6beats/min$. And the younger had a higher heart rate than the older one. Average conduction times in the RP, the QRS complex and the QTc interval recorded $166.7{\pm}23.1msec.$, $79.7{\pm}8.8msec.$ and $395.5{\pm}30.4msec.$, in the P and T wave duration recorded $70.1{\pm}13.5msec.$ and $97.6{\pm}16.9msec.$, and in the PR and ST segment duration recorded $97.9{\pm}23.5msec.$ and $173.9{\pm}40.3msec.$, respectively. The wave forms in each lead observed various types. The amplitudes of wave type showed the highest frequency in each lead that were analyzed as follow : 1. In P wave, amplitudes of the positive type showed the frequency of 65.3%, 82.7% and 52.0% in leads I, II and III that were $103.1{\pm}47.8{\mu}V$, $115.2{\pm}37.3{\mu}V$ and $67.4{\pm}26.9{\mu}V$, and it showed the frequency of 54.1% and 85.7% in the leads aVL and aVF that were $63.7{\pm}23.0{\mu}V$, $88.0{\pm}83.6{\mu}V$, respectively. Average amplitude of the negative type showed the frequency of 78.6% in lead aVR which was $99.3{\pm}38.0{\mu}V$. 2. Average amplitude of the QRS complex were from $362.8{\pm}177.7{\mu}V$ to $532.8{\pm}253.9{\mu}V$(mean of $449.1{\pm}57.2{\mu}V$) that in all leads except lead I were manifested the Low-Voltage QRS complex(below 0.5mV). Average amplitudes of each wave type in the QRS complex aere $-50.2.4{\pm}258.2{\mu}V$ and $-428.6{\pm}195.1{\mu}V$ in the QS groups type that showed a frequency of 66.3%, 70.4% in the leads I and aVL, were $451.1{\pm}20.4.0{\mu}V$, $387.6{\pm}175.8{\mu}V$ and $299.3{\pm}146.5{\mu}V$ in the R groups type that showed a frequency of 48.0%, 53.1% and 34.7% in the leads III, aVR and aVF, and were $-307.5{\pm}180.3{\mu}V$, $201.4{\pm}77.2{\mu}V$ in the QR wave type which showed a frequency of 39.8% in lead II, respectively. 3. In T wave, amplitude of the positive type showed the frequency of 50.0%, 82.7%, 51.0% and 57.1% in leads II, III aVR and aVF which were $214.9{\pm}115.6{\mu}V$, $188.5{\pm}119.3{\mu}V$, $191.0{\pm}93.7{\mu}V$ and $165.7{\pm}91.9{\mu}V$, and the negative type showed a frequecny of 66.3% and 72.5% in leads I and aVL. that were $221.3{\pm}112.5{\mu}V$, $-173.6{\pm}86.7{\mu}V$, respectively. 4. Amplitude of ST segment in leads I, II and III were a mean of $-12.2{\pm}37.2{\mu}V$, $17.5{\pm}42.6{\mu}V$ and $28.3{\pm}40.4{\mu}V$, in leads aVR, aVL and aVF were $-3.9{\pm}32.5{\mu}V$, $-15.9{\pm}35.6{\mu}V$ and $26.2{\pm}37.5{\mu}V$, respectively.

  • PDF

The novel NPLVTSCR ESD ProtectionCircuit without Latch-up Phenomenon for High-Speed I/O Interface (Latch-up을 방지한 고속 입출력 인터페이스용 새로운 구조의 NPLVTSCR ESD 보호회로)

  • Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.11 no.1 s.20
    • /
    • pp.54-60
    • /
    • 2007
  • In this study novel ESD protection device, namely, N/P-type Low Voltage Triggered SCR, has been proposed, for high speed I/O interface. Proposed device could lower high trigger voltage($\sim$20V) of conventional SCR and reduce latch-up phenomenon of protection device during the normal condition. In this Study, the proposed NPLVTSCR has been simulated using TMA MEDICI device simulator for electrical characteristic. Also the proposed device's test pattern was fabricated using 90nm TSMC's CMOS process and was measured electrical characteristic and robustness. In the result, NPLVTSCR has 3.2V $\sim$ 7.5V trigger voltage and 2.3V $\sim$ 3.2V holding voltage by changing PMOS gate length and it has about 2kV, 7.5A HBM ESD robustness(IEC61000-4-2).

  • PDF