• Title/Summary/Keyword: V.A.S

Search Result 11,800, Processing Time 0.041 seconds

A summary of KEPCO's 765kV substation design (한전 765kV 변전소의 기본설계 개요)

  • Kim, M.D.;Jung, S.H.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2139-2142
    • /
    • 1999
  • 765kV substations which will be the core installation of the bulk power transmission system in Korea for the upcoming $21^{st}$ century, were designed of outdoor full GIS type to minimize required area. As principal equipment, main transformers of 2,000 MVA per bank and 50kA 8,000A gas insulated switchgears of up-to-date technology were adopted in designing substations to transmit bulk power of 10GW. Dual digital protective relay systems and distributed indication and control systems with fiber optic LAN were used.

  • PDF

Experimental Investigation of Physical Mechanism for Asymmetrical Degradation in Amorphous InGaZnO Thin-film Transistors under Simultaneous Gate and Drain Bias Stresses

  • Jeong, Chan-Yong;Kim, Hee-Joong;Lee, Jeong-Hwan;Kwon, Hyuck-In
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.2
    • /
    • pp.239-244
    • /
    • 2017
  • We experimentally investigate the physical mechanism for asymmetrical degradation in amorphous indium-gallium-zinc oxide (a-IGZO) thin-film transistors (TFTs) under simultaneous gate and drain bias stresses. The transfer curves exhibit an asymmetrical negative shift after the application of gate-to-source ($V_{GS}$) and drain-to-source ($V_{DS}$) bias stresses of ($V_{GS}=24V$, $V_{DS}=15.9V$) and ($V_{GS}=22V$, $V_{DS}=20V$), but the asymmetrical degradation is more significant after the bias stress ($V_{GS}$, $V_{DS}$) of (22 V, 20 V) nevertheless the vertical electric field at the source is higher under the bias stress ($V_{GS}$, $V_{DS}$) of (24 V, 15.9 V) than (22 V, 20 V). By using the modified external load resistance method, we extract the source contact resistance ($R_S$) and the voltage drop at $R_S$ ($V_{S,\;drop}$) in the fabricated a-IGZO TFT under both bias stresses. A significantly higher RS and $V_{S,\;drop}$ are extracted under the bias stress ($V_{GS}$, $V_{DS}$) of (22 V, 20V) than (24 V, 15.9 V), which implies that the high horizontal electric field across the source contact due to the large voltage drop at the reverse biased Schottky junction is the dominant physical mechanism causing the asymmetrical degradation of a-IGZO TFTs under simultaneous gate and drain bias stresses.

A NOTE ON WITT RINGS OF 2-FOLD FULL RINGS

  • Cho, In-Ho;Kim, Jae-Gyeom
    • Bulletin of the Korean Mathematical Society
    • /
    • v.22 no.2
    • /
    • pp.121-126
    • /
    • 1985
  • D.K. Harrison [5] has shown that if R and S are fields of characteristic different from 2, then two Witt rings W(R) and W(S) are isomorphic if and only if W(R)/I(R)$^{3}$ and W(S)/I(S)$^{3}$ are isomorphic where I(R) and I(S) denote the fundamental ideals of W(R) and W(S) respectively. In [1], J.K. Arason and A. Pfister proved a corresponding result when the characteristics of R and S are 2, and, in [9], K.I. Mandelberg proved the result when R and S are commutative semi-local rings having 2 a unit. In this paper, we prove the result when R and S are 2-fold full rings. Throughout this paper, unless otherwise specified, we assume that R is a commutative ring having 2 a unit. A quadratic space (V, B, .phi.) over R is a finitely generated projective R-module V with a symmetric bilinear mapping B: V*V.rarw.R which is nondegenerate (i.e., the natural mapping V.rarw.Ho $m_{R}$ (V, R) induced by B is an isomorphism), and with a quadratic mapping .phi.:V.rarw.R such that B(x,y)=(.phi.(x+y)-.phi.(x)-.phi.(y))/2 and .phi.(rx)= $r^{2}$.phi.(x) for all x, y in V and r in R. We denote the group of multiplicative units of R by U(R). If (V, B, .phi.) is a free rank n quadratic space over R with an orthogonal basis { $x_{1}$, .., $x_{n}$}, we will write < $a_{1}$,.., $a_{n}$> for (V, B, .phi.) where the $a_{i}$=.phi.( $x_{i}$) are in U(R), and denote the space by the table [ $a_{ij}$ ] where $a_{ij}$ =B( $x_{i}$, $x_{j}$). In the case n=2 and B( $x_{1}$, $x_{2}$)=1/2, we reserve the notation [ $a_{11}$, $a_{22}$] for the space.the space.e.e.e.

  • PDF

765kV Substations Earthquake Monitoring System and Preliminary Data Analysis (765kV 변전소 지진계측시스템 구축과 관측자료 예비분석)

  • Park, Dong-Hee;Yun, Kwan-Hee;Seo, Yong-Pyo;Kim, Byung-Chel
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.56-63
    • /
    • 2006
  • Facilities of 76skV Substation(S/S) play an important role in electric power supply grids. Various power facilities of 765kV S/S might be damaged enormously if a strong earthquake occurs. In an effort to mitigate possible earthquake disasters, KEPRI (Korea Electric Power Research Institute) set forth plans to verify seismic safety of the facilities of 765kV S/S. To accomplish the task, an earthquake monitoring systems is constructed at four 765kV S/S sites(Shin-AnSung, Shin-TaeBaek, Shin-SeoSan and Shin-GaPyung). Data from these earthquake monitoring stations are being transmitted via satellite communication. Currently, KEPRI is operating an earthquake monitoring system in freefield of Shin-SeoSan S/S (NSS) tentatively, Also, the data from NSS is preliminarily analyzed using the horizontal to vertical (H/V) spectrum ratio method. The method of H/V spectrum ratio has been used to infer site amplification without previous knowledge of near surface geology. The results of data analysis shorts good S/N ratio and amplification of 20-25 Hz by site effect. In the near future, the accumulated data is expected to provide a basis for assessing and predicting any damages to integrity of 765kV S/S facilities by earthquakes.

  • PDF

SIMPLICIAL WEDGE COMPLEXES AND PROJECTIVE TORIC VARIETIES

  • Kim, Jin Hong
    • Bulletin of the Korean Mathematical Society
    • /
    • v.54 no.1
    • /
    • pp.265-276
    • /
    • 2017
  • Let K be a fan-like simplicial sphere of dimension n-1 such that its associated complete fan is strongly polytopal, and let v be a vertex of K. Let K(v) be the simplicial wedge complex obtained by applying the simplicial wedge operation to K at v, and let $v_0$ and $v_1$ denote two newly created vertices of K(v). In this paper, we show that there are infinitely many strongly polytopal fans ${\Sigma}$ over such K(v)'s, different from the canonical extensions, whose projected fans ${Proj_v}_i{\Sigma}$ (i = 0, 1) are also strongly polytopal. As a consequence, it can be also shown that there are infinitely many projective toric varieties over such K(v)'s such that toric varieties over the underlying projected complexes $K_{{Proj_v}_i{\Sigma}}$ (i = 0, 1) are also projective.

The clinical Observation on 2 cases of patients with Post-herpetic Neuralgia treated by Sa-am-acupuncture and Arctii Fructus water extrac (대상포진을 동반한 삼차신경통 환자 2례에 대한 증례 보고)

  • Nam, Sea hyun;Lee, Hyun
    • Journal of Haehwa Medicine
    • /
    • v.13 no.2
    • /
    • pp.259-265
    • /
    • 2004
  • Objective; This study was designed to investigate the effect of Sa-am acupuncture and Arctii Fructus water extract on Post-herpetic Neuralgia. Method: We have treated them with acupuncture treatment of Sa-am acupuncture and Arctii Fructus water extract and evaluated the effect by Pain Rating Score(P.R.S.) and Visual Analogue Scale(V.A.S.) scale. Result: Before theraphy, the grades of Song's scale were P.R.S. 80 and V.A.S. 100, Kim's sclae's P.R.S. 77 and V.A.S. 100. After theraphy, the grades of song's scale were P.R.S. 5 and V.A.S. 10, Kim's scales's P.R.S. 10 and V.A.S. 10 Conclusion: The treatment of Sa-am-acupuncture and Arctii Fructus water extract on Post-herpetic Neuralgia was effective and will be attempted to the patients with it.

  • PDF

SECURE DOMINATION PARAMETERS OF HALIN GRAPH WITH PERFECT K-ARY TREE

  • R. ARASU;N. PARVATHI
    • Journal of applied mathematics & informatics
    • /
    • v.41 no.4
    • /
    • pp.839-848
    • /
    • 2023
  • Let G be a simple undirected graph. A planar graph known as a Halin graph(HG) is characterised by having three connected and pendent vertices of a tree that are connected by an outer cycle. A subset S of V is said to be a dominating set of the graph G if each vertex u that is part of V is dominated by at least one element v that is a part of S. The domination number of a graph is denoted by the γ(G), and it corresponds to the minimum size of a dominating set. A dominating set S is called a secure dominating set if for each v ∈ V\S there exists u ∈ S such that v is adjacent to u and S1 = (S\{v}) ∪ {u} is a dominating set. The minimum cardinality of a secure dominating set of G is equal to the secure domination number γs(G). In this article we found the secure domination number of Halin graph(HG) with perfet k-ary tree and also we determined secure domination of rooted product of special trees.

A study on SFCL application for the interconnection operation of 154kV power systems under 345kV S/S in Korean power system

  • Lee Seung Ryul;Kim Jong Yul;Yoon Jae Young
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.2
    • /
    • pp.47-51
    • /
    • 2005
  • This paper is for studying the feasibility of SFCL application for the interconnection operation of 154kV power systems under 345kV S/S in Korean power system. All Korean 154kV power systems are constructed as loop systems in downtown. However, the present 154kV systems are operated with separated systems around 345kV S/S because of fault current and overload problems. In this study, we investigate the structure and operation of 154kV power system in Seoul and study the feasibility of interconnection operation of 154kV systems under 345kV systmes by applying SFCLs to 154kV bus-tie.

Teleseismic Travel Time Tomography for the Mantle Velocity Structure Beneath the Melanesian Region (원거리 지진 주시 토모그래피를 이용한 멜라네시아 지역의 맨틀 속도 구조 연구)

  • Jae-Hyung Lee;Sung-Joon Chang
    • Economic and Environmental Geology
    • /
    • v.57 no.1
    • /
    • pp.1-15
    • /
    • 2024
  • The Melanesian region in the western Pacific is dominated by complex plate tectonics, with the largest oceanic plateau, the OntongJava plateau, and a hotspot, the Caroline Islands. To better understand the complex geodynamics of the region, we estimate P- and S-velocity models and 𝛿 (VP/VS) model by using relative teleseismic travel times measured at seismometers on land and the seafloor. Our results show high-velocity anomalies in the subduction zones of the Melanesian region to a depth of about 400 km, which is thought to be subducting Solomon Sea, Bismarck, and Australian plates along plate boundaries. Along subduction zones, positive 𝛿 (VP/VS) anomalies are found, which may be caused by partial melting due to dehydration. A broad high-velocity anomaly is observed at 600 km depth below the Ontong-Java plateau, with a negative 𝛿 (VP/VS) anomaly. This is thought to be a viscous and dry remnant of the Pacific plate that subducted at 45-25 Ma, with a low volume of fluids due to dehydration for a long period in the mantle transition zone. Beneath the Caroline Islands, a strong low-velocity anomaly is obseved to a depth of 800 km and appears to be connected to the underside of the remnant Pacific plate in the mantle transition zone. This suggests that the mantle plume originating in the lower mantle has been redirected due to the interaction with the remnant Pacific plate and has reached its current location. The mantle plume also has a positive 𝛿 (VP/VS) anomaly, which is thought to be due to the influence of embedded fluids or partial melting. A high-velocity anomaly, interpreted as an effect of the thick lithosphere beneath the Ontong-Java plateau, is observed down to 300 km depth with a negative 𝛿 (VP/VS) anomaly, which likely indicate that little fluid remains in the melt residue accumulated in the lithosphere.

Memory Characteristic Measurement of Electroluminescent Device using V-Q Lissajous' Figure (V-Q lissajous 도형을 이용한 전계발광 소자의 메모리 특성 측정)

  • Jeong, D.Y.;Lim, M.S.;Yun, S.H.;Shin, Y.S.;Kwon, S.S.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1783-1785
    • /
    • 1999
  • In this paper, we apply V-Q Lissajoucs' figure for observation of a V-Q (Voltage-Charge) hysteresis loop at interface between phosphor and insulation layer in P-ELDz which are a simple structure and the back lighting of LCDs (Liquid Crystal Display). In V-Q Lissajous' figure, we measured a change of hysteresis loop according to the thickness of Insulation and phosphor layer. From experiment result, we will be obtained a optimum thickness of insulation with comparing the correlation of a V-L (Voltage-Luminance) and V-Q hysteresis loop.

  • PDF