• Title/Summary/Keyword: V.A.K.

Search Result 24,951, Processing Time 0.055 seconds

Water Treatment Characteristics by Const ucted Wetland with Different Vegetation - Open Water Arrangements (식생습지와 개방수역의 배열에 따른 인공습지의 수처리 특성)

  • Jang, Jeong-Ryeol;Choi, Sun-Hwa;Kwun, Soon-Kuk
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.122-130
    • /
    • 2007
  • This study was conducted to evaluate water treatment characteristics according to vegetated wetland(V) and open water(O) arrangements in free water surface constructed wetland. Three pilot-scale wetlands, V-V, O-V and V-O, were built and operated. $BOD_5$ was a slightly reduced at all the arrangements because the influent concentration was so low as background concentration of constructed wetlands. While T-N and T-P removal efficiency showed higher than 50% for all cases. The O-V arrangement showed the highest removal efficiency: 20% for $BOD_5$, 56% for SS, 59% for T-N and 72% for T-P. Effluent concentration of the O-V were significantly low compared with those from the V-O. O-V arrangement would be beneficial in the light of pollutant removal efficiency as well as construction cost.

Isolation and Indentification of Yeast Strains Producing High Concentration of Ethanol with High Viabi-lity. (에탄올 생성능과 생존능이 우수한 효모균주의 분리와 동정)

  • Kang, Tae-Young;Oh, Gui-Hwan;Kim, Keun
    • Microbiology and Biotechnology Letters
    • /
    • v.28 no.6
    • /
    • pp.309-315
    • /
    • 2000
  • To isolate yeast strains producing high concentration of ethanol, 125 strains were subjected to screening. Initially 14 strains able to grow in a medium containing 15%(v/v) ethanol, 7 strains capable of growing in a medium containing 50%(v/v) glucose, 23 strains having relatively fast fermentation rates, 13 strains able to grow at $42^{\circ}C$ were selected. After secondary screening, 11 strains having relatively high ini-tial fermentation rate and producing high concentration of ethanol were selected. After tertiary screening 5 strains producing high concentration of ethanol were selected. These 5 strains were again for their ethanol produc-tion, residual sugar, and viability using fermentation medium containing 25% glucose. The strain producing the highest concentration of ethanol was 20-1 strain which produced 10.56%(v/v) ethanol in 4 days, and the highest viable strain was 11-1 which produced 10.35%(v/v) ethanol(13.1%. v/v) with the viability of 30.44% after 5 days of fermentation. Both of the 20-1 and 11-1 strains were identified as Saccharomyces cerevisiae.

  • PDF

Triclosan Resistance in a Bacterial Fish Pathogen, Aeromonas salmonicida subsp. salmonicida, is Mediated by an Enoyl Reductase, FabV

  • Khan, Raees;Lee, Myung Hwan;Joo, Haejin;Jung, Yong-Hoon;Ahmad, Shabir;Choi, Jinhee;Lee, Seon-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.4
    • /
    • pp.511-520
    • /
    • 2015
  • Triclosan, the widely used biocide, specifically targets enoyl-acyl carrier protein reductase (ENR) in the bacterial fatty acid synthesis system. Although the fish pathogen Aeromonas salmonicida subsp. salmonicida exhibits triclosan resistance, the nature of this resistance has not been elucidated. Here, we aimed to characterize the triclosan resistance of A. salmonicida subsp. salmonicida causing furunculosis. The fosmid library of triclosan-resistant A. salmonicida subsp. salmonicida was constructed to select a fosmid clone showing triclosan resistance. With the fosmid clone showing triclosan resistance, a subsequent secondary library search resulted in the selection of subclone pTSR-1. DNA sequence analysis of pTSR-1 revealed the presence of a chromosomal-borne fabV-encoding ENR homolog. The ENR of A. salmonicida (FabVas) exhibited significant homology with previously known FabV, including the catalytic domain YX(8)K. fabVas introduction into E. coli dramatically increased its resistance to triclosan. Heterologous expression of FabVas might functionally replace the triclosan-sensitive FabI in vivo to confer E. coli with triclosan resistance. A genome-wide search for fabVas homologs revealed the presence of an additional fabV gene (fabVas2) paralog in A. salmonicida strains and the fabVas orthologs from other gram-negative fish pathogens. Both of the potential FabV ENRs expressed similarly with or without triclosan supplement. This is the first report about the presence of two potential FabV ENRs in a single pathogenic bacterium. Our result suggests that triclosan-resistant ENRs are widely distributed in various bacteria in nature, and the wide use of this biocide can spread these triclosan-tolerant ENRs among fish pathogens and other pathogenic bacteria.

BLOW UP OF SOLUTIONS TO A SEMILINEAR PARABOLIC SYSTEM WITH NONLOCAL SOURCE AND NONLOCAL BOUNDARY

  • Peng, Congming;Yang, Zuodong
    • Journal of applied mathematics & informatics
    • /
    • v.27 no.5_6
    • /
    • pp.1435-1446
    • /
    • 2009
  • In this paper we investigate the blow up properties of the positive solutions to a semi linear parabolic system with coupled nonlocal sources $u_t={\Delta}u+k_1{\int}_{\Omega}u^{\alpha}(y,t)v^p(y,t)dy,\;v_t={\Delta}_v+k_2{\int}_{\Omega}u^q(y,t)v^{\beta}(y,t)dy$ with non local Dirichlet boundary conditions. We establish the conditions for global and non-global solutions respectively and obtain its blow up set.

  • PDF

A Design of Current-mode Buck-Boost Converter using Multiple Switch with ESD Protection Devices (ESD 보호 소자를 탑재한 다중 스위치 전류모드 Buck-Boost Converter)

  • Kim, Kyung-Hwan;Lee, Byung-Suk;Kim, Dong-Su;Park, Won-Suk;Jung, Jun-Mo
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.330-338
    • /
    • 2011
  • In this paper, a current-mode buck-boost converter using Multiple switching devices is presented. The efficiency of the proposed converter is higher than that of conventional buck-boost converter. In order to improve the power efficiency at the high current level, the proposed converter is controlled with PWM(pulse width modulation) method. The converter has maximum output current 300mA, input voltage 3.3V, output voltage from 700mV to 12V, 1.5MHz oscillation frequency, and maximum efficiency 90%. Moreover, this paper proposes watchdog circuits in order to ensure the reliability and to improve the performance of dc-dc converters. An electrostatic discharge(ESD) protection circuit for deep submicron CMOS technology is presented. The proposed circuit has low triggering voltage using gate-substrate biasing techniques. Simulated result shows that the proposed ESD protection circuit has lower triggering voltage(4.1V) than that of conventional ggNMOS(8.2V).

ON A FUNCTIONAL EQUATION ARISING FROM PROTH IDENTITY

  • Chung, Jaeyoung;Sahoo, Prasanna K.
    • Communications of the Korean Mathematical Society
    • /
    • v.31 no.1
    • /
    • pp.131-138
    • /
    • 2016
  • We determine the general solutions $f:\mathbb{R}^2{\rightarrow}\mathbb{R}$ of the functional equation f(ux-vy, uy+v(x+y)) = f(x, y)f(u, v) for all x, y, u, $v{\in}\mathbb{R}$. We also investigate both bounded and unbounded solutions of the functional inequality ${\mid}f(ux-vy,uy+v(x+y))-f(x,y)f(u,v){\mid}{\leq}{\phi}(u,v)$ for all x, y, u, $v{\in}\mathbb{R}$, where ${\ph}:\mathbb{R}^2{\rightarrow}\mathbb{R}_+$ is a given function.

The Study on the Upper-bound of Labeling Number for Chordal and Permutation Graphs (코달 및 순열 그래프의 레이블링 번호 상한에 대한 연구)

  • Jeong, Tae-Ui;Han, Geun-Hui
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.8
    • /
    • pp.2124-2132
    • /
    • 1999
  • Given a graph G=(V,E), Ld(2,1)-labeling of G is a function f : V(G)$\longrightarrow$[0,$\infty$) such that, if v1,v2$\in$V are adjacent, $\mid$ f(x)-f(y) $\mid$$\geq$2d, and, if the distance between and is two, $\mid$ f(x)-f(y) $\mid$$\geq$d, where dG(,v2) is shortest distance between v1 and in G. The L(2,1)-labeling number (G) is the smallest number m such that G has an L(2,1)-labeling f with maximum m of f(v) for v$\in$V. This problem has been studied by Griggs, Yeh and Sakai for the various classes of graphs. In this paper, we discuss the upper-bound of ${\lambda}$ (G) for a chordal graph G and that of ${\lambda}$(G') for a permutation graph G'.

  • PDF

TOPOLOGICAL CONJUGACY OF DISJOINT FLOWS ON THE CIRCLE

  • Cieplinski, Krzysztof
    • Bulletin of the Korean Mathematical Society
    • /
    • v.39 no.2
    • /
    • pp.333-346
    • /
    • 2002
  • Let $F={F^v:S^1->S^1,v\in\; V$ and $g={G^v:S^1->S^1,v\in\; V$ be disjoint flows defined on the unit circle $S^1$, that is such flows that each their element either is the identity mapping or has no fixed point ((V, +) is a 2-divisible nontrivial abelian group). The aim of this paper is to give a necessary and sufficient codition for topological conjugacy of disjoint flows i.e., the existence of a homeomorphism $\Gamma:S^1->S^1$ satisfying $$\Gamma\circ\ F^v=G^v\circ\Gamma,\; v\in\; V$$ Moreover, under some further restrictions, we determine all such homeomorphisms.

V2X Technology Trends for Next-Generation Mobility

  • Kim, Young-Hak
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.1
    • /
    • pp.7-13
    • /
    • 2020
  • We describes V2X technology, a connectivity-based recognition technology that is attracting attention as a key technology for implementing autonomous driving technology, and autonomous communication modules that implement ADAS technology, a sensor-based recognition technology. It also explains the trends in V2X technology standardization centered on IEEE 802.11p, which is a WAVE technology standard based on Wi-Fi/DSRC. Finally, we will discuss the market growth trend of V2X communication modules in the United States, the leading V2X technology module, and the development of technology development trends of major domestic and international companies that are leading the global technology market related to V2X communication modules. V2X and ADAS technologies will be the biggest influence on automotive purchasing decisions. In recent years, V2I mandates have been promoted beyond V2V, mainly in developed countries such as the United States. The related industry needs to focus on the development of information transmission network technology that can support high frequency high efficiency(transmission rate) and sophisticated positioning accuracy beyond conventional vehicle communication.

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).