• 제목/요약/키워드: V-factor

검색결과 2,456건 처리시간 0.029초

BINDING NUMBER AND HAMILTONIAN (g, f)-FACTORS IN GRAPHS

  • Cai, Jiansheng;Liu, Guizhen
    • Journal of applied mathematics & informatics
    • /
    • 제25권1_2호
    • /
    • pp.383-388
    • /
    • 2007
  • A (g, f)-factor F of a graph G is Called a Hamiltonian (g, f)-factor if F contains a Hamiltonian cycle. The binding number of G is defined by $bind(G)\;=\;{min}\;\{\;{\frac{{\mid}N_GX{\mid}}{{\mid}X{\mid}}}\;{\mid}\;{\emptyset}\;{\neq}\;X\;{\subset}\;V(G)},\;{N_G(X)\;{\neq}\;V(G)}\;\}$. Let G be a connected graph, and let a and b be integers such that $4\;{\leq}\;a\;<\;b$. Let g, f be positive integer-valued functions defined on V(G) such that $a\;{\leq}\;g(x)\;<\;f(x)\;{\leq}\;b$ for every $x\;{\in}\;V(G)$. In this paper, it is proved that if $bind(G)\;{\geq}\;{\frac{(a+b-5)(n-1)}{(a-2)n-3(a+b-5)},}\;{\nu}(G)\;{\geq}\;{\frac{(a+b-5)^2}{a-2}}$ and for any nonempty independent subset X of V(G), ${\mid}\;N_{G}(X)\;{\mid}\;{\geq}\;{\frac{(b-3)n+(2a+2b-9){\mid}X{\mid}}{a+b-5}}$, then G has a Hamiltonian (g, f)-factor.

몬테칼로 계산을 이용한 평판형 전리함의 고에너지 전자선에 대한 선질보정인자 결정 (Determination of Quality Correction Factors for a Plane-Parallel Chamber in High Energy Electron Beams using Monte Carlo Calculation)

  • 정동혁;이정옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권1호
    • /
    • pp.89-95
    • /
    • 2008
  • 국제원자력기구의 TRS-398 측정 프로토콜을 임상에 적용하기 위해서는 사용하는 빔과 전리함에 대한 선질 보정인자가 필요하다. 본 연구에서는 몬테칼로 계산코드(DOSRZnrc/EGSnrc)를 사용하여 상용의 평판형전리함에 대한 고에너지 전자선($4{\sim}20\;MeV$)에서의 선질보정인자를 계산하였다. 계산결과를 프로토콜에서 제시하는 값과 비교한 결과 $5{\sim}20\;MeV$에서 약 1% 이내로 일치하였으며 4 MeV의 경우에는 약 1.9% 차이를 보였다. 본 연구 방법은 선질보정인자를 독립적으로 결정하는 방법의 하나로서 프로토콜에서 주어진 값들의 확인이 필요하거나 또는 새로운 모델의 전리함을 사용하는 경우에 응용될 수 있다.

  • PDF

SHARP ORE-TYPE CONDITIONS FOR THE EXISTENCE OF AN EVEN [4, b]-FACTOR IN A GRAPH

  • Cho, Eun-Kyung;Kwon, Su-Ah;O, Suil
    • 대한수학회지
    • /
    • 제59권4호
    • /
    • pp.757-774
    • /
    • 2022
  • Let a and b be positive even integers. An even [a, b]-factor of a graph G is a spanning subgraph H such that for every vertex v ∈ V (G), dH(v) is even and a ≤ dH(v) ≤ b. Let κ(G) be the minimum size of a vertex set S such that G - S is disconnected or one vertex, and let σ2(G) = minuv∉E(G) (d(u)+d(v)). In 2005, Matsuda proved an Ore-type condition for an n-vertex graph satisfying certain properties to guarantee the existence of an even [2, b]-factor. In this paper, we prove that for an even positive integer b with b ≥ 6, if G is an n-vertex graph such that n ≥ b + 5, κ(G) ≥ 4, and σ2(G) ≥ ${\frac{8n}{b+4}}$, then G contains an even [4, b]-factor; each condition on n, κ(G), and σ2(G) is sharp.

NEIGHBORHOOD CONDITION AND FRACTIONAL f-FACTORS IN GRAPHS

  • Liu, Hongxia;Liu, Guizhen
    • Journal of applied mathematics & informatics
    • /
    • 제27권5_6호
    • /
    • pp.1157-1163
    • /
    • 2009
  • Let G be a graph with vertex set V(G) and let f be a nonnegative integer-valued function defined on V(G). A spanning subgraph F of G is called a fractional f-factor if $d^h_G$(x)=f(x) for all x $\in$ for all x $\in$ V (G), where $d^h_G$ (x) = ${\Sigma}_{e{\in}E_x}$ h(e) is the fractional degree of x $\in$ V(F) with $E_x$ = {e : e = xy $\in$ E|G|}. In this paper it is proved that if ${\delta}(G){\geq}{\frac{b^2(k-1)}{a}},\;n>\frac{(a+b)(k(a+b)-2)}{a}$ and $|N_G(x_1){\cup}N_G(x_2){\cup}{\cdots}{\cup}N_G(x_k)|{\geq}\frac{bn}{a+b}$ for any independent subset ${x_1,x_2,...,x_k}$ of V(G), then G has a fractional f-factor. Where k $\geq$ 2 be a positive integer not larger than the independence number of G, a and b are integers such that 1 $\leq$ a $\leq$ f(x) $\leq$ b for every x $\in$ V(G). Furthermore, we show that the result is best possible in some sense.

  • PDF

Genotype Distribution of the Mutations in the Coagulation Factor V Gene in the Korean Population: Absence of Its Association with Coronary Artery Disease

  • Hong, Seung-Ho
    • Animal cells and systems
    • /
    • 제7권3호
    • /
    • pp.255-259
    • /
    • 2003
  • Mutations in the factor Ⅴ gene are major risk markers for venous thrombosis. Several factors for blood coagulation have been related with cardiovascular disease. Ⅰ investigated genotype distribution for three mutations (G1691 A, A2379G and G2391 A) of the factor Ⅴ gene in the Korean population. Genotype frequencies were examined by polymerase chain reaction in 135 patients with coronary artery disease (CAD) and 116 healthy subjects. For the G1691A mutation (factor Ⅴ

90-265$V_{rms}$ 입력범위를 갖는 단일전력단 역률개선 컨버터 (A Single-Stage Power Factor Correction Converter for 90-265$V_{rms}$ Line Applications)

  • 구관본
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.145-149
    • /
    • 2000
  • A single-stage power factor correction AC/DC converter with a simple link voltage suppressing circuit (LVSC) for the universal line application is proposed. Using this simple circuit a low link voltage can be realized without deadbands at line zero-crossings. The proposed converter is analyzed and a prototype converter with 5C, 12V output is implemented to verify the performance. The experimental results show that the link voltage stress and efficiency are about 447V and 81%, respectively.

  • PDF

Factor Rank and Its Preservers of Integer Matrices

  • Song, Seok-Zun;Kang, Kyung-Tae
    • Kyungpook Mathematical Journal
    • /
    • 제46권4호
    • /
    • pp.581-589
    • /
    • 2006
  • We characterize the linear operators which preserve the factor rank of integer matrices. That is, if $\mathcal{M}$ is the set of all $m{\times}n$ matrices with entries in the integers and min($m,n$) > 1, then a linear operator T on $\mathcal{M}$ preserves the factor rank of all matrices in $\mathcal{M}$ if and only if T has the form either T(X) = UXV for all $X{\in}\mathcal{M}$, or $m=n$ and T(X)=$UX^tV$ for all $X{\in}\mathcal{M}$, where U and V are suitable nonsingular integer matrices. Other characterizations of factor rank-preservers of integer matrices are also given.

  • PDF

중성자 조사된 SiC Schottky Diode의 온도 의존 특성 (Temperature Dependence of Neutron Irradiated SiC Schottky Diode)

  • 김성수;구상모
    • 한국전기전자재료학회논문지
    • /
    • 제27권10호
    • /
    • pp.618-622
    • /
    • 2014
  • The temperature dependent characteristics on the properties of SiC Schottky Diode has been investigated. In this study, the temperature dependent current-voltage characteristics of the SiC Schottky diode were measured in the range of 300 ~ 500 K. Divided into pre- and post- irradiated device was measured. The barrier height after irradiation device at 500 K increased 0.15 eV compared to 300 K, the barrier height of pre- neutron irradiated Schottky diode increased 0.07 eV. The effective barrier height after irradiation increased from 0.89 eV to 1.05 eV. And ideality factor of neutron irradiated Schottky diode at 500 K decreased 0.428 compared to 300 K, the ideality factor of pre- neutron irradiated Schottky diode decreased 0.354. Also, a slight positive shift in threshold voltage from 0.53 to 0.68 V. we analyzed the effective barrier height and ideality factor of SiC Schottky diode as function of temperature.

몬테카를로방법을 이용한 V2B(Vehicle to Building) 운용 제로에너지빌딩의 액티브 요소 예측 연구 (Forecast study for active factor of V2B(Vehicle to Building) operation zero energy building using monte carlo method)

  • 김영일;김인수
    • 에너지공학
    • /
    • 제26권4호
    • /
    • pp.29-34
    • /
    • 2017
  • 제로에너지빌딩의 요소는 크게 액티브 요소와 패시브 요소 두 가지로 나뉘며, 패시브 요소의 경우 단열, 창호, 차양, 외부분 등 건물의 단열, 열교 성능 등을 나타내는 요소들을 지칭하며, 액티브 요소의 경우는 에너지생산량 및 효율 계수 등을 나타내는 요소이다. 액티브 요소의 에너지생산량은 일반적으로 신재생에너지 발전을 통해 이루어진다. 본 연구에서는 신재생에너지 발전이 아닌 V2B(Vehicle to Building)라는 전기차의 양방향 충방전 기술이 제로에너지빌딩에 액티브 요소로 적용될 경우 어느 정도의 영향을 미칠지에 대해 예측하였다. 신재생발전의 경우 지리, 기후환경에 따라 발전량이 예측될 수 있지만 V2B의 경우 전기차 이용자의 방전의사, 가용 충전기의 대수 등 여러 가지 입력변수를 고려하여 예측하여야 한다. 예측한 결과에 따라 V2B가 제로에너지빌딩의 액티브 요소에 얼마나 기여할 수 있는지 확인 할 수 있으며, 해당 예측은 통계자료가 부족한 실정이기에 확률적 방법을 이용하여 예측해야한다. 본 연구에서는 해당 확률적 방법 중 몬테카를로 방법을 이용하여 DR(Demand Response)발령 시간대를 기준으로 충방전 패턴의 변화를 예측하였다.

전조등 조도변동에 대한 운전자의 인식연구 : 3. 운전자의 심리적 특성 (A Study on Driver's Perception over the Change of the Headlamp's Illuminance : 3. Driver's psychological property)

  • 김현지;김현진;김기훈;김훈;안옥희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.120-124
    • /
    • 2006
  • In this study, psychological assessment was carried out to investigate the driver's psychological characteristics by the change of the headlight. The participants were 20 men and 20 women in their 20s and thirty-two different conditions in combinations of waveform of light, voltage, and alteration time were used. The questionnaire for the assessment was evaluated by 8 subjective items and 5-point SD criteria of 19 pair's adjective. The results were as follows. 1. The assessment results from SD method indicated 3 factors by factor analysis, and it was shown that A waveform had significances in a sense of security and impetus and B waveform had a significance in a sense of security The levels of the limitations for the voltage change were 12V in the factor of a sense of security and 11V in the factor of a sense of impetus for A waveform, 12.6V in the factor of a sense of security for B waveform. 2. The results of the subjective assessment showed that the limitation of A waveform's brightness change was 12V. Moreover, the limitations of voltage changes were 12.6V for B waveform brightness change, 12V for discomfort, 12.6V for darkness. And the limitation of C waveform's brightness change was 12V.

  • PDF