• Title/Summary/Keyword: V flame

Search Result 168, Processing Time 0.024 seconds

A Combustion Analysis of Surface Fuel Burning Experiment According to Density Variation (밀도에 따른 지표 연료의 연소실험 분석)

  • Kim, Eung-Sik;Kim, Jang-Hwan;Kim, Dong-Hyun;Park, Hyung-Ju;Kim, Jeong-Hun
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • This paper shows combustion characteristics of fallen leaves of Quercus variabilis and Pinus densiflora according to variation of mass densities. Combustion temperature, mass loss rate, flame height, duration of combustion and velocity of hot gas are measured and analyzed. For the experiment 10cm heighted baskets with varying diameters of 20, 30, 40 and 50cm are used for the combustion and the pilot ignition is carried on the top of the fuel. In case of Pinus densiflora mass loss rate, duration of flame, flame height and combustion time become larger as the mass density and diameter of basket increase, on the other hand Quercus variabilis shows saturation characteristics in mass loss rate and flame height. Velocity of hot gas is proportional to flame height.

Development of flame retardant materials utilizing recycled polypropylene and inorganic waste (재활용(再活用) 폴리프로필렌과 무기계(無機界) 폐기물(廢棄物)을 이용(利用)한 난연성(難燃性) 소재(素材) 개발(開發))

  • Chun, Byoung-Chul;Cho, Tae-Keun;Park, Hyun-Gue;Choi, Hyung-Joon;Chung, Yong-Chan;Jeon, Ho-Seok
    • Resources Recycling
    • /
    • v.16 no.4
    • /
    • pp.17-26
    • /
    • 2007
  • Inorganic shell powder waste was added to recycled polypropylene(COPP), and its effect on the mechanical properties and flammability was investigated. Compatibilizer(Polytail H) was added to improve mechanical properties of COPP/shell composites. Also three different flame retardants($Al_2O_3$, DBDPO, $Sb_2O_3$) were added to improve flammability. Experimental results indicated that addition of compatibilizer resulted in an improved mechanical properties, and especially impact strength approached that of 100 wt% COPP. Addition of flame retardant did not result in decreased mechanical properties. UL-94 flammability test indicated that COPP/shell composite did not show good flame retardancy, however, in the case of COPP/shell composites containing flame retardant showed good flammability. flammability was found $Sb_2O_3>Al_2O_3>DBDPO$ in this order. Finally, UL-94 V-0 grade was found in COPP/shell composite with $Al_2O_3$, compatibilizer, and 40 wt% shell, and COPP/shell composites with $Sb_2O_3$.

Preparation and physical properties of flame retardant high density polyethylene utilizing inorganic waste shell powder (재활용(再活用) 굴 껍질 분말(粉末)을 이용(利用)한 고밀도 폴리에틸렌계 난연 소재(素材)의 제조(製造)와 물성(物性))

  • Choi, Jae-Won;Cho, Tae-Keun;Ahn, Jun-Hyung;Lee, Sung-Ho;Chung, Yong-Chan;Jeon, Ho-Seok;Chun, Byoung-Chul
    • Resources Recycling
    • /
    • v.17 no.4
    • /
    • pp.21-29
    • /
    • 2008
  • Waste shell powder was added to the high density polyethylene(HDPE), and resultant mechanical properties and flame retardancy were analyzed in terms of shell content. Compatibilizer(PE-g-MA) was used to enhance the mechanical properties of the prepared HDPE/shell composites, and several flame retardant agents($Al_2O_3$, $Sb_2O_3$) were utilized to improve flame retardancy. Addition of the compatibilizer resulted in an improved mechanical properties due to the increased interfacial bonding between HDPE matrix and shell powder. In the case of impact strength, it even reached to the impact strength of pure HDPE. Also the addition of the flame retardant agents did not exhibit mechanical property decrease. UL-94 flammability test on the prepared HDPE/shell composites indicated that at 40wt% of shell only inclusion, time to ignite the flame and the total time of flame duration increased. When flame retardant agents mixed with shell powder were added to the HDPE matrix, improved flame retardancy was observed. Generally, flame retardancy effect of $Al_2O_3$ was better than $Sb_2O_3$. UL-94 V-0 classification was observed for the specimens with $Al_2O_3$ and compatibilizer at more than 40wt% shell, and also for specimens with $Sb_2O_3$ and compatibilizer at all shell content.

Numerical Study of Methane-hydrogen Flameless Combustion with Variation of Recirculation Rate and Hydrogen Content using 1D Opposed-flow Diffusion Flame Model of Chemkin (Chemkin 기반의 1차원 대향류 확산 화염 모델을 활용한 재순환율 및 수소 함량에 따른 메탄-수소 무화염 연소 특성 해석 연구)

  • Yu, Jiho;Park, Jinje;Lee, Yongwoon;Hong, Jongsup;Lee, Youngjae
    • Clean Technology
    • /
    • v.28 no.3
    • /
    • pp.238-248
    • /
    • 2022
  • The world is striving to transition to a carbon-neutral society. It is expected that using hydrogen instead of hydrocarbon fuel will contribute to this carbon neutrality. However, there is a need for combustion technology that controls the increased NOx emissions caused by hydrogen co-firing. Flameless combustion is one of the alternative technologies that resolves this problem. In this study, a numerical analysis was performed using the 1D opposed-flow diffusion flame model of Chemkin to analyze the characteristics of flameless combustion and the chemical reaction of methane-hydrogen fuel according to its hydrogen content and flue gas recirculation rate. In methane combustion, as the recirculation rate (Kv) increased, the temperature and heat release rate decreased due to an increase in inert gases. Also, increasing Kv from 2 to 3 achieved flameless combustion in which there was no endothermic region of heat release and the region of maximum heat release rate merged into one. In H2 100% at Kv 3, flameless combustion was achieved in terms of heat release, but it was difficult to determine whether flameless combustion was achieved in terms of flame structure. However, since the NOx formation of hydrogen flameless combustion was predicted to be similar to that of methane flameless combustion, complex considerations of flame structure, heat release, and NOx formation are needed to define hydrogen flameless combustion.

The Analysis of Voltage Waveform and Oxidation Growth of Conductor with Series Arc (직렬 아크에 따른 도체의 산화물 증식 및 전압 파형 분석)

  • Choi, Chung-Seog;Kim, Hyang-Kon;Kim, Dong-Ook;Kim, Dong-Woo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.3
    • /
    • pp.146-152
    • /
    • 2006
  • In order to analyze the characteristics of series arcs that could happen in poor connections of electrical facilities, we made an apparatus which is similar to actual situation. series arcs are generated between copper and copper, copper and bronze, copper and brass, bronze and bronze, and then oxidation growth and voltage waveform were measured. A very small vibration with constant movement is needed to grow oxidation initially, whereas oxidation growth proceeded without a vibration after a certain amount of time. At first, blue white flame was generated initially between copper and copper, and then yellow flame was generated. In case of contact between copper and copper, the length of oxidation growth was about 7.1[mm] in 90[min]. In case of contact between copper and brass, the length of oxidation growth was about 4.3[mm] in 90[min], When bronze is contacted with copper, the lengths of oxidation growth were about 1.4[mm] in 20[min] and 2.7[mm] in 40[min] respectively, and no more oxidation growth was shown after that. In case of contact between brass and brass, the length of oxidation growth was about 1.2[mm] in 90[min], so it was the smallest compared to other cases. When copper is contacted with copper, the current through the load was about 1.6[A] and the power dissipation increased from 19[W] to 31[W]. In case of oxidation growth between copper and brass, the voltage changed from 8.4[V] to 11[V]. However, the voltage drop and the power dissipation between copper and brass were small compared to oxidation growth between copper and copper. When series arcs were generated between bronze and copper, a peak was shown at the beginning of voltage increase, and 40[min] later, oxidation material was not grown any longer. When oxidation growth occurred, voltage waveform showed irregular waveforms with tiny ripples.

Evaluation of Combustion Characteristics of Outdoor Advertisement Materials (옥외 광고물 소재의 연소특성 평가)

  • Eom, Sang-Yong;Kim, Kyoung-Jin;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.79-84
    • /
    • 2012
  • Combustion characteristics of outdoor advertisement materials were evaluated for fire risk assessment about fire expanding. At this study, the flame retardancy and the limiting oxygen index (LOI) was measured by UL 94 and ASTM D 2863 respectively. At the result of flame retardancy, foamex was V-0 grade and those of others were out of grade. LOI measurement showed that the LOI of foamex was highest in the samples. The cone calorimeter test was done by ISO 5660-1 to find the combustion characteristics. The cone calorimeter test showed that the outdoor advertisement materials were not good to prevent of fire expanding. The time to ignition (TTI) of flex was the fastest and the peak heat release rate (PHRR) as well as the total heat release (THR) of acrylic panel was higher than those of others.

Flame Retardant and Heat Radiating Composite Consisting of Polyurethane and Modified Boron Nitride (폴리우레탄과 개질된 질화붕소로 이루어진 난연성 방열 복합체)

  • Kim, Min-gyu;Lee, Chang-rock;Jo, Nam-Ju
    • Applied Chemistry for Engineering
    • /
    • v.31 no.5
    • /
    • pp.487-494
    • /
    • 2020
  • Polyurethane/modified boron nitride (PU/m-BN) composite was synthesized from the poly(tetra methylene glycol) (PTMG), 4,4'-methylenebis(phenyl isocyanate) (MDI), and modified boron nitride (m-BN). The modification of boron nitride and synthesis of PU/m-BN composite were confirmed by Fourier transform infrared (FT-IR) spectroscopic analyses. The mechanical properties of the PU/m-BN composites were measured using the universal testing machine (UTM) and the thermal properties of the composites were investigated ser flash analysis (LFA) and UL94 measurements. As a result, the thermal conductivity of the polyurethane composite increased to 1.19 W/m·K, and the flame retardancy of the easy to burn polyurethane, which was not self-extinguishing was improved to UL94 V-1 grade.

Effect of Surface Treatments with Flame Plasma and Silane on Mechanical Properties of Silica Reinforced Elastomeric Composites (화염 플라즈마 및 실란 표면처리가 실리카 강화 고무복합재료의 기계적 특성에 미치는 영향)

  • Lee, Jun-Man;Ryu, Sang-Ryeoul;Lee, Dong-Joo
    • Composites Research
    • /
    • v.24 no.6
    • /
    • pp.18-24
    • /
    • 2011
  • The effect of surface treatments with the atmospheric pressure flame plasma (APFP) and epoxy silane (ES) is experimentally investigated to yield the best mechanical properties of silica ($V_f=40%$) reinforced elastomeric composites. The tensile strength of the composites is increased significantly with decrease the mean diameter. When the diameter is $2.2{\mu}m$, that of the composite is increased about 1.4 times compared to the matrix (2.52 MPa). Also, the tensile strength of silica reinforced composites with APFP and ES treated is increased 8.8~13.3%, 9.9~12.5%, respectively. When the diameter is $26.6{\mu}m$, the tensile modulus of the composite is increased about 2 times compared to the matrix (0.88MPa), and the tensile modulus of silica reinforced composites with APFP and ES treated is increased 15.6~22.8%, 21.1~5.8%, respectively. Conventional silane coupling agent treatment have a few disadvantages because of using organic solvents. However APFP treatment is a fast, economic and eco-friendly method to improve the mechanical properties.

A Study on the Short-Circuit Characteristics of Vinyl Cords Damaged by External Flame (외부화염에 의해 소손된 비닐 코드의 단락 특성에 관한 연구)

  • Choi Chung-Seog;Kim Hyang-Kon;Shong Kil-Mok
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.72-77
    • /
    • 2004
  • In this paper, we studied on the short-circuit process, surface structure, and component variation of vinyl cords. In the results of high speed imaging system (HSIS) analysis, as soon as wire covering was damaged by heat, the conductor of wire came in contact with the other conduct of wire, and the short-circuit occurred. Stereomicroscope and SEM analysis indicated that the source part of wire showed V-type form. The molten beads of load part were bigger than those of source part. In the results of EDX analysis, Cu and O were detected in the source part, whereas covering material (Cl, Ca), Cu and O were detected in the load part. The results will help us to find out the cause of electrical fire.