미국 중소도시의 형태기반코드 구성요소에 관한 연구 - 건축계획요소를 포함한 조닝코드 사례를 중심으로 - (A Study of Components in Form-Based Codes of Small to Mid Cities in US - Focused on Zoning Codes Including Architectural Design Elements -)

  • 박성용;안동준
    • 대한건축학회논문집:계획계
    • /
    • 제34권4호
    • /
    • pp.77-85
    • /
    • 2018
  • Rapid urbanization has fostered development of modern cities. Although Conventional zoning played its role to control urban development, it also segregated land uses and created homogeneous development pattern. Mega cities with satellite bed towns has not shown their unique identity and characters. In order to develop comprehensive approach which may bring social and physical enhancement can be difficult to achieve by considering city as a two dimensions. On contrary, extensive analysis and proposals require an approach which can perceive city with three dimensions. Form-Based Codes (FBCs) are appeared as an alternative to conventional zoning with different design process and principles. FBCs approach urban place with three dimension and giving priority to form rather than land use. The purpose of this study was to analyze the necessity of FBCs and its concept, components and how this would change urban characteristics in the aspects of architectural design through analysis on 4 case studies for zoning codes of US cities. Through comparison of components in Form-Based Codes of 4 different cases, this study can show the reasons for differences in application of Form-Based Codes and how detailed components would play a role to establish better urban environments.

도시공원의 유형 및 입지적 특성이 공동주택가격에 미치는 영향 (Effects of Types and Locational Characteristics of Urban Parks on the Apartment Price)

  • 이고은;최열
    • 대한토목학회논문집
    • /
    • 제36권5호
    • /
    • pp.927-936
    • /
    • 2016
  • 본 연구는 도시공원의 유형 및 입지적 특성이 공동주택 가격에 미치는 영향을 분석하기 위한 논문으로 부산광역시 전체를 연구대상지로 설정하였다. 공원은 환경재로서 주변으로의 영향력이 크게 작용함에도 불구하고 기존 논문들의 경우 공원 자체만을 대상으로 가치를 평가한 연구가 대부분이다. 이에 본 연구에서는 공원과 인근 공동주택과의 관계를 분석함으로서 그 경제적 가치를 판단하고자 한다. 특히 공원과 공동주택 그 자체의 물리적 객관적 특성을 반영하였다는 점에서 의의를 가진다. 또한 공원의 유형을 세부적으로 나누어 분석함으로서 유형별 특징을 분석함에 주안점을 두었다. 분석결과 공동주택의 층수, 해당 단지의 총 세대수, 건설사 도급순위, 공원지정 경과년수, 부도심 입지여부 등이 주택가격에 양(+)의 영향을 미치는 것으로 나타났다. 반대로 공동주택의 면적, 건축연한, 공원 조성계획 수립여부, 공원과 공동주택과의 거리, 도심입지여부, 지역생활권 입지여부 등은 음(-)의 관계로 분석되었다. 특히 공원별 유형에서 근린공원, 소공원, 체육공원은 공동주택 가격에 양(+)의 관계를 보였으나 어린이 공원의 경우 음(-)의 관계로 나타났다. 공원과 공동주택의 거리가 가까울수록 공동주택의 가격이 오르는 것은 공원이 주는 다양한 이점을 많은 사람들이 선호하게 되는 것을 의미한다. 이에 공원의 가치를 높이고 조성으로 인한 효과를 최대화하기 위하여 좀 더 다양한 방안으로의 노력이 필요할 것으로 사료된다.

DEM의 정확도 분석에 의한 도시 소유역의 유출해석 (Runoff of an Small Urban Area Using DEM Accuracy Analysis)

  • 박진형;이관수;이삼노
    • 한국지리정보학회지
    • /
    • 제7권1호
    • /
    • pp.28-38
    • /
    • 2004
  • 본 연구는 수치지형자료의 해상도와 보간법의 변화에 따른 정확도 분석을 실시하여 도시소유역의 유출현상을 해석하고자 하였다. 수치자료는 격자크기별로 TIN 보간법을 이용하여 DEM 자료를 생성하고, 정확도 분석은 수치지도의 등고선을 이용하여 결정계수($R^2$)와 회귀식을 도출하였다. 검증된 DEM 자료를 사용하여 소유역구분, 면적, 유역폭, 지면경사도 등의 지형인자를 추출하여 도시유출모형에 적용시켜 여서-문수지구의 도시 소유역에 가장 적합한 유출모형을 알아보고자 한다. 모형의 적용 결과 SWMM의 유출수문곡선이 ILLUDAS의 유출수문곡선보다 실측값에 더 근사하게 나타났고, SWMM의 경우 실측값과 최대 19%, 최소 5%, 평균 13%의 오차를 나타냈다. 본 연구대상지역과 같은 도시소유역은 강우지속시간이 첨두도달시간에 미치는 영향은 미미하게 나타났다. 본 연구의 결과로 SWMM 모형이 여서-문수지역의 도시유출모형으로 적합하며 적용면에서도 더 다양한 기능과 정확성을 나타낸다고 판단된다.

  • PDF

GIS 기반의 SWMM 모형을 이용한 하수도시스템 선정에 따른 도시하천 수질개선효과의 정량적 분석 (Analysis of the Effects of Sewer System on Urban Stream using SWMM based on GIS)

  • 장주형;박해식;박청길
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.982-990
    • /
    • 2006
  • Generally CSOs (Combined Sewer Overflows) are regarded as one of the most serious nonpoint pollution source in the urban watershed, Particularly, the water quality of the Oncheon stream is seriously affected by CSOs because the capacity of interception sewer system connected to the Suyoung wastewater treatment plant is too small to intercept most storm water discharges. The objective of this study is to evaluate the effect of nonpoint source on an urban stream with regards to combined sewer system and separate sewer system using GIS (Geographic Information System) and SWMM (Storm Water Management Model), and to provide an insight for the management of urban stream water quality. In order to consider the effect of CSOs on the receiving water quality, the flow divider element in SWMM was applied. The model calibration and verification were performed by the measured data of quantity and quality on the Oncheon stream. The quantity data acquired from the Suyoung wastewater treatment plant were also used for this procedure. In case of separate sewer system, the modeling results showed the increased tendency in streamflow compared with the combined system in dry weather, In addition, the water quality is remarkably improved in rainfall events at the separate condition. The results imply that the construction of separate sewer system should be taken into first consideration to restore the quality and quantity of water in urban streams.

일제강점기 조선시가지계획령에 고시된 부산 소재 도시공원의 변천 (Transitions of Urban Parks in Busan noticed by the Chosun Planning Ordinance in the Japanese Colonial Period)

  • 김영하;윤국빈;강영조
    • 한국조경학회지
    • /
    • 제45권1호
    • /
    • pp.1-15
    • /
    • 2017
  • 본 연구는 일제강점기에 계획된 부산 도시공원 32개소를 대상으로 도시의 성장과 발전에 따른 공원의 변화과정을 고찰했다. 특히, 도시공원의 변화과정을 도시계획적 관점에서 검토하기 위해 부산시에서 편찬된 도시계획사 관련 서적, 부산시보 고시공고, 도시공원 유원지 녹지현황 내부 자료, 결재문서 등을 조사 분석했다. 그 결과, 일제강점기 일본 거류지역 일본인에 의해 조성된 대정공원, 고관공원, 용두산공원은 시가지 공원계획 이전부터 공원으로 이용되었으며, 이러한 공원을 포함한 1944년 법적으로 명시한 32개소의 공원은 방재기능을 고려하여 계획되었다. 해방이후, 한국전쟁의 혼란한 시기와 도시계획 재정비로 인해 공원부지는 무허가 건축물 난립, 주택건설, 상업지, 공공청사 및 학교 건립 등으로 이용되었으며, 그에 반해 도심지에 위치한 도로공원과 대부분의 소공원은 폐지되었다. 하지만, 그린부산 정책과 더불어 일제강점기 당시 도심 외곽에 계획된 미집행 공원은 도시 성장으로 도심지에 위치한 주요 공원으로 자리 잡아, 쾌적한 도시형성을 위한 공원사업으로 연지공원, 양정공원, 당곡공원이 조성되고 있다. 이렇게 일제강점기에 계획된 32개소의 공원은 부산 도시형성 과정의 시대상을 반영하여 폐지 또는 조성되었다. 폐지된 공원은 개발압력에 토지매입 효율성이 낮다고 판단된 공원이며, 조성되고 있는 공원은 개발이 용이하지 못했던 위치에 입지한 공원이다. 따라서, 공원이 사회공통자본으로 인정받기 위해서는 공원 부지의 토지매입 여건에 대한 충분한 검토가 필요한 것으로 밝혀졌다.

대구지역의 환경친화적 도시계획을 위한 도시환경기후지도 작성에 관한 연구 (A Study on Urban Environmental Climate Mapping Method for Sustainable Urban Planning in Daegu)

  • 박명희;정우식;김해동
    • 한국환경과학회지
    • /
    • 제20권4호
    • /
    • pp.465-482
    • /
    • 2011
  • To preserve atmospheric environment of urban areas, it needs to create urban space considering air pollution sources and natural and geographical properties such as wind circulation. According to this study could examine climate and environmental characteristics of Daegu and accordingly suggest a climate map in urban environment and an "advice map" in urban planning. The urban area(area paved with asphalt and concrete) of Daegu has increased by more than five times since 1960. In addition, the analysis of thermal environment through satellite data shows that the surface temperature between a place paved with artificial structures and a farmland shows $10{\sim}20^{\circ}C$ difference during the daytime in the summer. Regarding the parks inhibiting the heat island of a city have the small area of trees, and the road paved with concrete is wide so that they hardly serve as the source of heat absorption. As Apsan is located to the south of Daegu and Palgonsan to the north and Daegu has east high west low type, mountain wind from mountains in the south and north passes a city and delivers heat and air pollutions at night. In the west of Daegue, there is the poorest environment and industrial facilities and environmental basic facilities are mostly located, so large residential complexes that are being built around the industrial facilities as if they set up a folding screen and therefore the poor environment is increasingly worse.

유휴지를 활용한 최적의 도시 녹지 공간 탐색 - 녹지연결성과 열 환경 개선을 목적으로 - (Exploration of Optimal urban green space using unused land - To improve green connectivity and thermal environment -)

  • 김은섭;이동근;윤은주;박채연
    • 한국환경복원기술학회지
    • /
    • 제22권5호
    • /
    • pp.45-56
    • /
    • 2019
  • Urban green areas are generally composed of relatively small and fragmented patches, but it is a critical factor for the quality of an urban environment. They have positive effects such as increasing green connectivity, reducing runoff, and mitigating urban heat. But, there is a lack of urban greening plans that consider the comprehensive effects of green space in real urban areas. To fill this gap in this literature, this study identifies a planning model that determines the optimal locations for maximizing green areas' multiple effects(e.g., heat mitigation and enhancement of connectivity) by using unused lots. This model also considers minimizing costs using meta-heuristic optimization algorithms. As a results, we finds 50 optimal plans that considers two effects within the limited cost in Nowon-gu. The optimal plans show the trade-off effect between connectivity, heat mitigation and cost. They also show the critical unused land lots for urban greening that are commonly selected in various plans. These optimal plans can effectively inform quantitative effectiveness of green space and their trade-off. We expect that our model will contribute to the improvement of green planning processes in reality.

초고층 공동주택의 소형풍력발전시스템 적용을 위한 수직연도 활용에 관한 연구 (A Study on the Vertical Flue Duct for Application of Small Wind Power System in High-Rise Apartments)

  • 김성용;이용호;박진철;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.116-125
    • /
    • 2011
  • This study examined vertical shafts in high-rise apartments of the old high-rise buildings, reviewed the possibility of using flue ducts, and analyzed airflow patterns according to pressure differences between in and out side of flue ducts through computational fluid dynamics(CFD). The resulting conclusions are as follows: 1) The analysis results of airflow according to the stack effect of flue ducts show that smaller-diameter flue ducts(${\phi}1.2m$) would be morefavorable in increasing downward wind velocity than bigger-diameter ones(${\phi}1.6m$) and that the introduction ducts for outside air should be more than 50% of flue duct diameter to obtain a downward wind velocity higher than $3.0^m/s$ that is the minimum blade wind velocity of a small domestic wind generator. 2) The optimal installation location of a bypass introduction duct is the neutral plane of a flue duct or lower. When the diameter of the upper duct is bigger than that of the lower duct, it will generate more effects on the increase of downward wind velocity in flue ducts.

공동주택에서의 소형풍력발전시스템 적용에 관한 연구 (A Study on the Application of Small Wind Power System in Apartment Housing)

  • 박진철;경남호
    • 한국태양에너지학회 논문집
    • /
    • 제23권2호
    • /
    • pp.21-34
    • /
    • 2003
  • This study aims to present the applicability of wind turbine generator system to urban buildings for the utilization of clean renewable energy. The results are as follows; According to the wind resource analysis, it has been found that small sized wind power system can be viable for buildings application due to the amplification of wind velocity around buildings or building clusters, in spite of low mean velocity of 2-3m/s in Seoul and Kyunggi urban areas. But planners must perform micrositing analysis around building so that wind turbine can be located at high velocity zones. The system must be designed to avoid obstacles preventing prevailing wind in buildings. It should be recognized that wind speeds are changing depending on the height and length from buildings. The wind power system can be used as a symbol of landmark which shows a sustainable architecture from the scenary Itself A case study for apartment building in urban showed that wind power systems can be applicable in two kinds of place, rooftops and ground levels. Especially, the wind power systems must be carefully positioned so that wind resources do not decrease when it is installed at ground levels. and according to life cycle cost analysis, adaption of new small win4 power systems to buildings were proved to produce a profit if it is considered the expense of environment improvement and the wind speed increasing according to rise of building height. This research will ultimately achieve green architecture that preserves nature and at the same time provides pleasant environment to humans, and will play a great role in establishing the environment-preserving sustainable architecture of the 21th century.

여름철 도시근린공원의 기온저감 효과 - 경기도 수원시 효원공원 - (Air Temperature Modification of an Urban Neighborhood Park in Summer - Hyowon Park, Suwon-si, Gyeonggi-do-)

  • 박수국;조상만;현철지;공학양;김승현;신영규
    • 한국환경과학회지
    • /
    • 제26권9호
    • /
    • pp.1057-1072
    • /
    • 2017
  • In order to investigate the effect of air temperature reduction on an urban neighborhood park, air temperature data from five inside locations (forest, pine tree, lawn, brick and pergola) depending on surface types and three outside locations (Suwon, Maetan and Kwonsun) depending on urban forms were collected during the summer 2016 and compared. The forest location had the lowest mean air temperature amongst all locations sampled, though the mean difference between this and the other four locations in the park was relatively small ($0.2-0.5^{\circ}C$). In the daytime, the greatest mean difference between the forest location and the two locations exposed to direct beam solar radiation (brick and lawn) was $0.5-0.8^{\circ}C$ (Max. $1.6-2.1^{\circ}C$). In the nighttime, the mean difference between the forest location and the other four locations in the park was small, though differences between the forest location and locations with grass cover (pine tree and lawn) reached a maximum of $0.9-1.7^{\circ}C$. Comparing air temperature between sunny and shaded locations, the shaded locations showed a maximum of $1.5^{\circ}C$ lower temperature in the daytime and $0.7^{\circ}C$ higher in the nighttime. Comparing the air temperature of the forest location with those of the residential (Kwonsun) and apartment (Maetan) locations, the mean air temperature difference was $0.8-1.0^{\circ}C$, higher than those measured between the forest location and the other park locations. The temperatures measured in the forest location were mean $0.9-1.3^{\circ}C$ (Max. $2.0-3.9^{\circ}C$) lower in the daytime than for the residential and apartment locations and mean $0.4-1.0^{\circ}C$ (Max. $1.3-3.1^{\circ}C$) lower in the nighttime. During the hottest period of each month, the difference was greater than the mean monthly differences, with temperatures in the residential and apartment locations mean $1.0-1.6^{\circ}C$ higher than those measured in the forest location. The effect of air temperature reduction on sampling locations within the park and a relatively high thermal environment on the urban sampling locations was clearly evident in the daytime, and the shading effect of trees in the forest location must be most effective. In the nighttime, areas with a high sky view factor and surface types with high evapotranspiration potential (e.g. grass) showed the maximum air temperature reduction. In the urban areas outside the park, the low-rise building area, with a high sky view factor, showed high air temperature due to the effect of solar (shortwave) radiation during the daytime, while in the nighttime the area with high-rise buildings, and hence a low sky view factor, showed high air temperature due to the effect of terrestrial (longwave) radiation emitted by surrounding high-rise building surfaces. The effect of air temperature reduction on the park with a high thermal environment in the city was clearly evident in the daytime, and the shading effect of trees in the forest location must be most effective. In the nighttime, areas with high sky view factor and surface types (e.g., grass) with evapotranspiration effect showed maximum air temperature reduction. In the urban areas outside the park, the high sky view factor area (low-rise building area) showed high air temperature due to the effect of solar (shortwave) radiation during the daytime, but in the nighttime the low sky view factor area (high-rise building area) showed high air temperature due to the effect of terrestrial (longwave) radiation emitted surrounding high-rise building surfaces.