A Study on the Vertical Flue Duct for Application of Small Wind Power System in High-Rise Apartments  

Kim, Seong-Yong (School of Architecture & Urban Environmental Engineering, Kyungpook National University)
Lee, Yong-Ho (School of Architecture & Urban Environmental Engineering, Kyungpook National University)
Park, Jin-Chul (School of Architecture & Building Science, Chung-Ang University)
Hwang, Jung-Ha (School of Architecture & Urban Environmental Engineering, Kyungpook National University)
Publication Information
Journal of the Korean Solar Energy Society / v.31, no.3, 2011 , pp. 116-125 More about this Journal
Abstract
This study examined vertical shafts in high-rise apartments of the old high-rise buildings, reviewed the possibility of using flue ducts, and analyzed airflow patterns according to pressure differences between in and out side of flue ducts through computational fluid dynamics(CFD). The resulting conclusions are as follows: 1) The analysis results of airflow according to the stack effect of flue ducts show that smaller-diameter flue ducts(${\phi}1.2m$) would be morefavorable in increasing downward wind velocity than bigger-diameter ones(${\phi}1.6m$) and that the introduction ducts for outside air should be more than 50% of flue duct diameter to obtain a downward wind velocity higher than $3.0^m/s$ that is the minimum blade wind velocity of a small domestic wind generator. 2) The optimal installation location of a bypass introduction duct is the neutral plane of a flue duct or lower. When the diameter of the upper duct is bigger than that of the lower duct, it will generate more effects on the increase of downward wind velocity in flue ducts.
Keywords
High-Rise Apartments; Vertical Shaft; Flue Duct; Stack Effect; CFD: Computational Fluid Dynamics; Small Wind Power System;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Jung-han Park, A Study on Thermal Phenomena and Stack Effect of Nude Elevator Shaft of High Rise Building that used CFD, SAREK, Summer Annual Conference, 2008, pp1059-1064.
2 박동식, 정광섭, 김영일, 김철호, 권지혜, 초고층 건물 내에서 수직 공기유로 비율에 관한 연구, 대한설비공학회 2010년도 하계학술발표대회, 2010.06, pp390-394
3 황진택, 유장열, 유기표, 김영문, 초고층 건물의 최상층에 풍력발전시스템을 구축하기 위한 다양한 유입구 형상에 대한 연구, 대한건축학회 학술발표대회논문집 구조계 제30권 제1호(통권제54집), 2010.10, pp.87-88
4 송종의, 임현우, 이준호, 이중훈, 송두삼,초고층건물의 연돌효과 특성의 검토, 대한건축학회 학술발표대회 논문집 계획계 제29권 제1호(통권 제53집), 2009.10.23, pp837-840
5 Jo J, H, Yeo, M, S, Yang, I, H and Kim K, W, A Study on thestack effect in high-rise building, Proceedings of the AIK '00 Annual Conference, Vol. 30, 2000, pp 769-772.
6 전현도, 박진철, 이언구, 초고층 건물의 풍력발전시스템 적용방안에 관한 연구,대한건축학회논문집 계획편 제26권 제8호(통권262호), 2010.08, pp273-280
7 정광섭, 김철호, 수직 공간 내에서 고도변화에 따른 기압차로 인한 기류현상 예측에 관한 연구, 설비공학논문집 제21권 제7호 2009 pp 409-416.
8 ASHERAE(2005), ASHERAE Handbook - Fundamentals(SI), American Society of Heating, Refrigeration, and Air-conditioning Engineers, Inc., Chapter 16
9 Walton, G.N., 2000, CONTAMW-User Manual, NISTIR 6476, National Institute of Standards and Technology.