• Title/Summary/Keyword: Urban Dust

Search Result 196, Processing Time 0.027 seconds

Comparison of Machine Learning Techniques in Urban Weather Prediction using Air Quality Sensor Data (실외공기측정기 자료를 이용한 도심 기상 예측 기계학습 모형 비교)

  • Jong-Chan Park;Heon Jin Park
    • The Journal of Bigdata
    • /
    • v.6 no.2
    • /
    • pp.39-49
    • /
    • 2021
  • Recently, large and diverse weather data are being collected by sensors from various sources. Efforts to predict the concentration of fine dust through machine learning are being made everywhere, and this study intends to compare PM10 and PM2.5 prediction models using data from 840 outdoor air meters installed throughout the city. Information can be provided in real time by predicting the concentration of fine dust after 5 minutes, and can be the basis for model development after 10 minutes, 30 minutes, and 1 hour. Data preprocessing was performed, such as noise removal and missing value replacement, and a derived variable that considers temporal and spatial variables was created. The parameters of the model were selected through the response surface method. XGBoost, Random Forest, and Deep Learning (Multilayer Perceptron) are used as predictive models to check the difference between fine dust concentration and predicted values, and to compare the performance between models.

Spatio-temporal Characteristics of the Frequency of Weather Types and Analysis of the Related Air Quality in Korean Urban Areas over a Recent Decade (2007-2016) (최근 10년간(2007~2016년) 한반도 대도시 일기유형 빈도의 시·공간 특성 및 유형별 대기질 변화 분석)

  • Park, Hyeong-Sik;Song, Sang-Keun;Han, Seung-Beom;Cho, Seongbin
    • Journal of Environmental Science International
    • /
    • v.27 no.11
    • /
    • pp.1129-1140
    • /
    • 2018
  • Temporal and spatial characteristics of the frequency of several weather types and the change in air pollutant concentrations according to these weather types were analyzed over a decade (2007-2016) in seven major cities and a remote area in Korea. This analysis was performed using hourly (or daily) observed data of weather types (e.g., mist, haze, fog, precipitation, dust, and thunder and lighting) and air pollutant criteria ($PM_{10}$, $PM_{2.5}$, $O_3$, $NO_2$, CO, and $SO_2$). Overall, the most frequent weather type across all areas during the study period was found to be mist (39%), followed by precipitation (35%), haze (17%), and the other types (${\leq}4%$). In terms of regional frequency distributions, the highest frequency of haze (26%) was in Seoul (especially during winter and May-June), possibly due to the high population and air pollutant emission sources, while that of precipitation (47%) was in Jeju (summer and winter), due to its geographic location with the sea on four sides and a very high mountain. $PM_{10}$ concentrations for dust and haze were significantly higher in three cities (up to $250{\mu}g/m^3$ for dust in Incheon), whereas those for the other four types were relatively lower. The concentrations of $PM_{2.5}$ and its major precursor gases ($NO_2$ and $SO_2$) were higher (up to $69{\mu}g/m^3$, 48 ppb, and 16 ppb, respectively, for haze in Incheon) for haze and/or dust than for the other weather types. On the other hand, there were no distinct differences in the concentrations of $O_3$ and CO for the weather types. The overall results of this study confirm that the frequency of weather types and the related air quality depend on the geographic and environmental characteristics of the target areas.

An Investigation for Air Pollutants Emitted from Small-Scale Incinerators in Highway Service Area (고속도로 휴게소의 소형소각로에서 배출되는 대기오염물질 조사)

  • Jang, Young-Kee;Choi, Sang-Jin;Kim, Kwan;Hong, Min-Sun;Choi, Join-In;Moon, Su-Ho;Kim, Soon-Tae;Kim, Seung-Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.539-546
    • /
    • 2002
  • The physicochemical properties of solid wastes generated from seven highway service areas, four branch offices, and one construction site were analyzed in concert with air pollutants including heavy metals emitted from near-by small-scale incinerators. The amount of solid wastes generated from highway areas has been increasing with recent increases in the number of highways and passengers. Twelve incinerators examined in this study generally had capacity smaller than 100 kg/hr, most of which were equipped with cyclone for dust removal. It was seen that the concentrations of the gas-phase air pollutants (e.g., SO$_2$, NO$_{x}$, HCl and H$_2$S) were above the acceptable emission standards except one or two sites. CO concentrations at all incinerators were also higher due to incomplete combustion. In addition, particulate matters showed concentration six times higher at their maximum. The results of heavy metal analysis showed that the concentrations of Cu, Cd, and Ni satisfied the emission standards. whereas Pb at one site and Zn at five sites exceeded the standards. Cr measurement results indicated that 9 of 12 incinerators had higher values than the standard; especially one branch office showed nine times higher than normal concentration. In order to satisfy more stringent emission standards in the near future, it is necessary to install air pollution control system and to develop an intensified management plan.n.

Removal Efficiency of PM10 & $CO_2$ in Subway Mock-up Cabin (지하철 목업차량내 객실 공기정화장치의 미세먼지(PM10) 및 $CO_2$ 저감성능평가)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;Cho, Goan-Hyun;Nam, Goong-Seok;Lee, Joo-Yeol;Kim, Tae-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.613-618
    • /
    • 2011
  • More than 7 million persons use Seoul Metropolitan Subways (SMS) everyday and the number has been in increasing trend. With the increasing trend of concerns on indoor air quality(IAQ), the management of IAQ has become an important issue, especially in case of subway operators, because most of subway lines are placed underground with poor ventilation condition. The ultimate object of study develop independent cleaning device that reduce efficient fine particle and $CO_2$. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. Two layered electrically pre-charged filters were used for removing particulate matters and gas absorbers are packed between two layer filters for removing gases pollutants such $CO_2$, VOCs and HCHO. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. SCAP prototype is producted as all in one method which decrease fine dust, $CO_2$ and noxious gas. and basic test carry out with quantity of wind, a gap of pressure, sampling efficiency.

  • PDF

Comparative Analysis of Elemental Components in Airborne Particulate Matter by k0-NAA Methods (대기분진의 원소분석에 대한 k0-NAA법의 비교)

  • Chung, Yong-Sam;Moon, Jong-Hwa;Cho, Hyun-Je;Kim, Young-Jin
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.51-58
    • /
    • 2005
  • A comparison of the analytical data obtained by three $k_0$-NAA software programs was carried out using both the airborne particulate matter collected from an urban site and the certified reference materials of the air filter and urban dust to evaluate the performance of the analysis. The individual $k_0$-NAA standardization methods of three countries, Korea, China and Vietnam which had been modified from the well established $k_0$-program were used for the comparative analysis. The measured concentrations of 30 elements from the two kinds of air samples based on this software were in agreement with each other within about 20% analytical error except for a few elements. By contrast, the results of China and Vietnam were moderately higher than that of Korea due to a systematic error associated with the detection efficiency, gamma peak analysis and geometric effect.

Concentration Variations of Persistent Organic Pollutants in Gosan, Jeju during the Polluted Period in November 2001 and the Yellow Sand Period in Spring 2002 (2001년 11월 오염시기와 2002년 봄 황사시기 제주도 고산에서의 잔류성 유기오염물질 농도 변화)

  • 김영성;김진영;김연제;문길주;문광주;한진석;김상우;윤순창;권성안
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.469-490
    • /
    • 2003
  • Atmospheric concentrations of persistent organic pollutants (POPs) were measured at Gosan, Jeju in November 2001 and spring 2002, each time for two weeks. Primary target pollutants were organochlorine pesticides, coplanar polychlorinated biphenyls (co- PCBs), and dioxin/furans listed in the Stockholm Convention adopted in May 2001. Polycyclic aromatic hydrocarbons (PAHs) were also measured in order to understand the overall characteristics of the POPs distribution as well as PM$_{2.5}$, a potent carrier of POPs. In the latter part of the measurement period of November 2001, almost every pollutant of combustion origin including dioxin/furans went high probably due to influence of emissions in the nearby area. The characteristics of atmospheric environment at Gosan in this period were rather close to urban areas far from those of a background area. A severe dust storm swept for three days at the end of the measurement period of spring 2002. However, changes in pollutant concentrations were relatively small except PM$_{10}$. Nevertheless, increases in particulate PAHs and OCDD (octachlorinated dibenzo-p-dioxins), mostly present in fine particles, were observed. Trends in organochlorine pesticide variations were mixed although possible volatilization of DDT residues from soil was inferred from the measurements of spring 2002.2.2.

Chemical Compositions in Rainwater at Hiroshima Prefecture, Japan

  • Kim, Do-Hoon;Takeda, Kazuhiko;Sakugawa, Hiroshi;Lee, Jin-Sik
    • Analytical Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.321-328
    • /
    • 2002
  • From May 1999 to July 2000, concentration of 17 metals (Al, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, Pb, Sr, V, Zn), 4 ions (${NH_4}^+$, $Cl^-$, ${NO_3}^-$, ${SO_4}^{2-}$) and pH in rainwater were investigated. The volume-weighted mean concentrations (VWM) of ${NO_3}^-$ and ${SO_4}^{2-}$ were 16.0 and $17.0{\mu}mol\;L^{-1}$. The average pH was 4.53, which ranged from 3.83 to 6.06. The characteristic variations of these species were investigated in terms of the source of these species by principal component analysis (PCA) and interelement correlation coefficients. The elements were classified into three categories: anthropogenic source (Cd, Cu, Fe, Ni, Pb, V, Zn, ${NH_4}^+$, ${NO_3}^-$, ${SO_4}^{2-}$ and $H^+$), soil and crust dust (Al, Ba, Ca, Fe, Mn) and sea salts (Mg, Na, $Cl^-$). In addition, we compared the concentrations in rainwater, which were taken on the same day in three sites (Higashi-Hiroshima, an urban-facing area and a mountain-facing area of Mt. Gokurakuji) in order to examine the regional effect against the concentrations in them. At the urban-facing area of Mt. Gokurakuji, the concentrations of chemical compositions were higher than other areas.

A Study on Architectural Form of Waste to Energy Plants in accordance with Law - Focus on Seoul and Tokyo - (법규에 따른 자원회수시설의 건축적 형태에 관한 연구 - 서울과 도쿄를 중심으로 -)

  • Jung, Seung-won;Lee, Kang-jun
    • Journal of Urban Science
    • /
    • v.11 no.1
    • /
    • pp.29-35
    • /
    • 2022
  • Waste to Energy Plant were recognized as hateful facilities, and there were many conflicts in the location due to social problems such as the NIMBY phenomenon due to problems such as damage to property in the surrounding area, odor, and image loss. Problems such as air pollution and odor are solved by the development of advanced prevention facilities such as electric dust collectors, wet cleaning systems, semi-dry reaction towers, bag filters, and catalyst towers (SCR: Selective Catalytic Reduction), and air recycling facilities in waste storage tanks. However, it is being avoided because of the perception that it is an incinerator. To resolve these conflicts, the government installs and operates resident convenience facilities to compensate residents near resource recovery facilities, provides green space and improves the environment, and supports heating expenses in accordance with the 「Waste Treatment Facility Support Act」. The purpose of this study is to derive implications through the analysis of domestic and overseas case studies for resident convenience facilities and environment improvement for the promotion of local communities in resource recovery facilities and use them as basic data for community promotion and environmental improvement when installing resource recovery facilities in the future.

Surface Ozone Episode Due to Stratosphere-Troposphere Exchange and Free Troposphere-Boundary Layer Exchange in Busan During Asian Dust Events

  • Moon, Y.S.;Kim, Y.K.;K. Strong;Kim, S.H.;Lim, Y.K.;Oh, I.B.;Song, S.K.
    • Journal of Environmental Science International
    • /
    • v.11 no.5
    • /
    • pp.419-436
    • /
    • 2002
  • The current paper reports on the enhancement of O$_3$, CO, NO$_2$, and aerosols during the Asian dust event that occurred over Korea on 1 May 1999. To confirm the origin and net flux of the O$_3$, CO, NO$_2$, and aerosols, the meteorological parameters of the weather conditions were investigated using Mesoscale Meteorological Model 5(MM5) and the TOMS total ozone and aerosol index, the back trajectory was identified using the Hybrid Single-Particle Lagrangian Integrated Trajectory Model(HYSPLIT), and the ozone and ozone precursor concentrations were determined using the Urban Ashed Model(UAM). In the presence of sufficiently large concentrations of NO$\sub$x/, the oxidation of CO led to O$_3$ formation with OH, HO$_2$, NO, and NO$_2$ acting as catalysts. The sudden enhancement of O$_3$, CO, NO$_2$ and aerosols was also found to be associated with a deepening cut-off low connected with a surface cyclone and surface anticyclone located to the south of Korea during the Asian dust event. The wave pattern of the upper trough/cut-off low and total ozone level remained stationary when they came into contact with a surface cyclone during the Asian dust event. A typical example of a stratosphere-troposphere exchange(STE) of ozone was demonstrated by tropopause folding due to the jet stream. As such, the secondary maxima of ozone above 80 ppbv that occurred at night in Busan, Korea on 1 May 2001 were considered to result from vertical mixing and advection from a free troposphere-boundary layer exchange in connection with an STE in the upper troposphere. Whereas the sudden enhancement of ozone above 100 ppbv during the day was explained by the catalytic reaction of ozone precursors and transport of ozone from a slow-moving anticyclone area that included a high level of ozone and its precursors coming from China to the south of Korea. The aerosols identified in the free troposphere over Busan, Korea on 1 May 1999 originated from the Taklamakan and Gobi deserts across the Yellow River. In particular, the 1000m profile indicated that the source of the air parcels was from an anticyclone located to the south of Korea. The net flux due to the first invasion of ozone between 0000 LST and 0600 LST on 1 May 1999 agreed with the observed ground-based background concentration of ozone. From 0600 LST to 1200 LST, the net flux of the second invasion of ozone was twice as much as the day before. In this case, a change in the horizontal wind direction may have been responsible for the ozone increase.

A Comparison between Wet-only and Bulk Deposition at Two Forest Sites in Japan

  • Imamura, Naohiro;Iwai, Noriko;Tanaka, Nobuaki;Ohte, Nobuhito
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.67-77
    • /
    • 2018
  • To investigate the effects of forest and the surrounding natural and anthropogenic sources on the bulk depositions on forested land, this study examined differences in ion concentrations between wet-only and bulk samples at two forested sites in Japan. The surrounding natural and anthropogenic sources at each site were different; Shirasaka is in a rural area and Tanashi is an urban environment. The volume weighted (vw) mean concentrations of $K^+$ and $Ca^{2+}$ in the bulk samples were significantly (p<0.05) higher than those in the wet-only samples at both sites. The forest canopy and a nearby incineration plant were hypothesized to be the main sources of $K^+$ contaminants at Shirasaka and Tanashi, respectively. The transport of sea salt and urban dust may explain the presence of enriched $Ca^{2+}$ concentrations in the bulk samples at Shirasaka and Tanashi, respectively. The $NH_4{^+}$ concentrations in the Shirasaka bulk samples were significantly (p<0.05) lower than those in the wet-only samples. The vw mean $SO{_4}^{2-}$ and $NO_3{^-}$ concentrations in both sample types were not significantly different at either site. This study demonstrated that the ion concentration differences between wet-only and bulk samples were affected by nearby natural and anthropogenic sources even at forest sites, similar to previous findings for non-forested locations. However, the $K^+$ concentration differences between wet-only and bulk samples may be higher owing to forest sources, even in the absence of anthropogenic sources.