• Title/Summary/Keyword: Up sampling

Search Result 831, Processing Time 0.035 seconds

Sampling Study on Environmental Observations: Precipitation, Soil Moisture and Land Cover Information

  • 유철상
    • Journal of Environmental Science International
    • /
    • v.5 no.2
    • /
    • pp.103-112
    • /
    • 1996
  • Observational date is integral in our understanding of present climate, its natural variability and any cnange roue to anturopogenic effects. This study incorporates a brief overview of sampling requirements using data from the first ISLSCP Field Experiment (FIFE) in 1987, which was a multi-disciplinary field experiment over a 15km grid in Konza Prairie, USA. Sampling strategies were designed for precipitation and soil moisture measurements and also detecting land cover type. It was concludes that up to 8 raingages would be needed for valuable precipitation measurements covering the whole FIFE catchment, but only one soil moisture station. Results show that as new gages or station are added to the catchment then the sampling error is reduced, but the Improvement in error performance is less as the number of gages or stations increases. Sampling from remoteiy sensed instruments shows different results. It can be seen that the sampling error at 1arger resolution sizes are small due to competing error contribution from both commission and omission error.

  • PDF

A Case study of an optimal design with structured sampling and simulation

  • Park, Hongjoon;Youngcook Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.46.4-46
    • /
    • 2002
  • This study was motivated how it might be possible to validate structured sampling with orthogonal array for optimal design of a pin. The Taguchi method by orthogonal array, one of the structured sampling methods, has much advantage that is row cost and time saving for experiments. But this method has been applied in limited areas especially for mechanical problems. In this study, we experimented whether the structured sampling is useful for applying optimal design of mechanical elements. For the experiment, we first set up a mechanical problem which was related to determining optimal parameters associated a pin's crack occurred inside a hole. We, then, calculated combination of...

  • PDF

Design of Audio Sampling Rate Conversion Block (Audio Sampling Rate Conversion Block의 설계)

  • 정혜진;심윤정;이승준
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.827-830
    • /
    • 2003
  • This paper proposes an area-efficient FIR filter architecture for sampling rate conversion of hi-fi audio data. Sampling rate conversion(SRC) block converts audio data sampled at 96KHz down to 48KHz sampled data and vice versa. 63-tap FIR filter coefficients have been synthesized that gives 100dB stop band attenuation and 5.2KHz transition bandwidth. Time-shared filter architecture requires only one multiplier and accumulator for 63-tap filter operation. This results in huge hardware saving of up to 10~19 times smaller compared with traditional FIR structure.

  • PDF

A Study on the Disturbance Effects with Sampling Methods of Soft Clay (연약 점성토의 시료채취방법에 따른 시료교란도의 영향에 관한 연구)

  • 박춘식;장정욱;김종환
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.577-584
    • /
    • 2002
  • We have employed two methods to remove slime at the end of the sampler in clay layers. The first method is a sampling process that harnesses low pressure to clean up the ground around the sampler tip. The second method, in consideration of a disturbed layer, involves a technique of inserting the sampler 50 cm deep into the ground before cleaning up the verge of the sampler by using high pressure. Physical and mechanical properties of these two methods have been compared and analyzed to investigate how different sampling methods affect degree of disturbance. The first method shows little disturbance since the unconfined compression test results in quite greater E$\_$50//q$\_$u/ in the first method than in the second method. On the other hand, the consolidation test results in a slightly greater compression index in the second method than in the first method, when their indexes are compared in the same depth. This suggests that the second method demonstrates less disturbance than the first method does. It is assumed that the second method may reduce disturbance slightly, However, we suspect that choosing any of the two methods would not obtain a considerable difference in sampling.

  • PDF

Sub-sampling Technique to Improve the Measurement Speed of White Light Scanning Interferometry (백색광 주사 간섭계의 측정 속도 개선을 위한 서브 샘플링 기법 연구)

  • Chyun, In-Bum;Joo, Ki-Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.11
    • /
    • pp.999-1006
    • /
    • 2014
  • In this investigation, we explain the sub-sampling technique of white light scanning interferometry (WLSI) to improve the measurement speed. In addition to the previous work using Fourier domain analysis, several methods to extract the height from the correlogram of WLSI are described with the sub-sampling technique. Especially, Fourier-inverse Fourier transformation method adopting sub-sampling technique is proposed and the phase compensation technique is verified with simulation and experiments. The main advantage of sub-sampling is to speed up the measurements of WLSI but the precision such as repeatability is slightly poor. In case of measuring the sample which has high height step or difference, the proposed technique can be widely used to reduce the measurement time.

Chorionic villus sampling

  • Shim, Soon-Sup
    • Journal of Genetic Medicine
    • /
    • v.11 no.2
    • /
    • pp.43-48
    • /
    • 2014
  • Chorionic villus sampling has gained importance as a tool for early cytogenetic diagnosis with a shift toward first trimester screening. First trimester screening using nuchal translucency and biomarkers is effective for screening. Chorionic villus sampling generally is performed at 10-12 weeks by either the transcervical or transabdominal approach. There are two methods of analysis; the direct method and the culture method. While the direct method may prevent maternal cell contamination, the culture method may be more representative of the true fetal karyotype. There is a concern for mosaicism which occurs in approximately 1% of cases, and mosaic results require genetic counseling and follow-up amniocentesis or fetal blood sampling. In terms of complications, procedure-related pregnancy loss rates may be the same as those for amniocentesis when undertaken in experienced centers. When the procedure is performed after 9 weeks gestation, the risk of limb reduction is not greater than the risk in the general population. At present, chorionic villus sampling is the gold standard method for early fetal karyotyping; however, we anticipate that improvements in noninvasive prenatal testing methods, such as cell free fetal DNA testing, will reduce the need for invasive procedures in the near future.

Randomized Response Model with Discrete Quantitative Attribute by Three-Stage Cluster Sampling

  • Lee, Gi-Sung;Hong, Ki-Hak
    • Journal of the Korean Data and Information Science Society
    • /
    • v.14 no.4
    • /
    • pp.1067-1082
    • /
    • 2003
  • In this paper, we propose a randomized response model with discrete quantitative attribute by three-stage cluster sampling for obtaining discrete quantitative data by using the Liu & Chow model(1976), when the population was made up of sensitive discrete quantitative clusters. We obtain the minimum variance by calculating the optimum number of fsu, ssu, tsu under the some given constant cost. And we obtain the minimum cost under the some given accuracy.

  • PDF

Aerosol Filtration/Sampling Device Based on Irrigated Rotating Wires

  • M. J. Shaw;M. R. Kuhlman;;J. A. Gieseke
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.265-267
    • /
    • 2000
  • The objective of this study is to analyze, design and evaluate a new gas cleanup or sampling system that will remove erosive, corrosive, and fouling contaminants present in an effluent stream as either solid or liquid particles providing a clean gas stream. The gas clean-up or sampling system considered in this study is an irrigated, rotating element device. The device consists of a central disk-like hub from which emanate radially wires or cylindrical elements. (omitted)

  • PDF

Digital Feedback Linerization of the Nonlinear System (비선형 시스템의 디지털 Feedback 선형화 기법)

  • 이홍기;전홍태;김찬호
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.6
    • /
    • pp.33-42
    • /
    • 1994
  • The sampling is inevitable in controlling the nonlinear continuous time system. This paper deals with digital feedback linearization problem which eliminates or reduces the effect of the sampling. Necessary and sufficient condition for reducing the sampling error up to O$(h^5)$ are obtained. Also, the effectiveness of our control scheme in accuracy and robustness is shown by comuter simulations.

  • PDF

Depth Map Enhancement and Up-sampling Techniques of 3D Images for the Smart Media (스마트미디어를 위한 입체 영상의 깊이맵 화질 향상 및 업샘플링 기술)

  • Jung, Jae-Il;Ho, Yo-Sung
    • Smart Media Journal
    • /
    • v.1 no.3
    • /
    • pp.22-28
    • /
    • 2012
  • As the smart media becomes more popular, the demand for high-quality 3D images and depth maps is increasing. However, performance of the current technologies to acquire depth maps is not sufficient. The depth maps from stereo matching methods have low accuracy in homogeneous regions. The depth maps from depth cameras are noisy and have low-resolution due to technical limitations. In this paper, we introduce the state-of-the-art algorithms for depth map enhancement and up-sampling from conventional methods using only depth maps to the latest algorithms referring to both depth maps and their corresponding color images. We also present depth map enhancement algorithms for hybrid camera systems in detail.

  • PDF